| 1 | Schedule \"A\" Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of Small Compressor Test Facility Building in D/S including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lump sum price worked out by the Contractor for “ADDITION / ALTERATION TO SMALL COMPRESSOR TEST FACILITY” as listed in Schedule ‘A’ Part - II representing____________ % __________________ percent Above /Below the lump sum price of ₹14,99,527.16 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing__________ % ____________ percent Above /Below the lump sum price of `9,69,639.00 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “EXCAVATION, EARTHWORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - IV representing__________ % ____________ percent Above /Below the lump sum price of `1,67,520.20 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “REFRIGERATION AND AIR CONDITIONING” as listed in Schedule ‘A’ Part - V representing_____________ % ___________________ percent Above / Below the lump sum price of ₹53,048.00 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part - VI representing___________ % ___________________ percent Above /Below the lump sum price of ₹96,497.60 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing____________ % ____________________________ percent Above/ Below the lump sum price of `87,719.20 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing__________ % __________________ percent Above / Below the lump sum price of ₹19,824.00 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Schedule \"A\" Part - IXThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 10.00 to 61.00. |
| 11 | INTERNAL ELECTRIFICATIONTaking down carefully unserviceable aluminium / copper point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, removing all material for reuse / issued under Schedule of Credit and making good the distrubed surface as the existing one complete all as specified and directed. |
| 12 | Taking down exiting copper / aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 13 | S&F, exhaust fan, steel body AC single phase 230V of size 450mm sweep 900RPM with blades and frame and louvers including cutting the wall of stone / brick masonry as per the size of exhaust fan including grouting the bolts, nuts etc., for fixing necessary connection with three core flexible wire from and making good the distrubed surface as the existing one, exhaust fan to ceiling rose complete all as specified and directed. |
| 14 | S&F, LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 1 x 20 watts fixing on wall / ceiling with rod complete all as specified and directed. |
| 15 | S&F LED luminaires square type 2\" x 2\" 36 W with environmental friendly new generation aesthetical designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstong / gypsum or similar ceiling mounting system including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed.Note: i) All necessary fixing / connecting arrangements to be provided by the contractor without any extra payment from department.ii) Quoted rate is to be deemed inclusive. |
| 16 | S&F, LED highbay light fittings 150W, IP66 very high efficiency round highbay in PDC housing suitable for industrial application. The luminare has efficacy upto 150Lm/W to reduce quantity / wattage thereby reducing operational cost complete all as specified and directed.Note: i) All necessary fixing / connecting arrangements of nuts, bolt, MS rod to be provided by the contractor without any extra payment from department.ii) Quoted rate is to be deemed inclusive. |
| 17 | S&F, LED building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including 1.5 mtr length GI tubing medium grade 25mm dia bent to shape with necessary CI clamps, bolts etc., for fixing and connecting from ceiling rose to filling with 3 core 1.5 Sqmm insulated copper cable complete all as specified and directed. |
| 18 | Note: i) All necessary fixing / connecting arrangements of nuts, bolt, MS rod to be provided by the contractor without any extra payment from department.ii) Quoted rate is to be deemed inclusive. |
| 19 | S&F, LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 1 x 10 watts fixing on wall / celing with rod complete all as specified and directed. |
| 20 | S&F, MCCB enclosure suitable for FP, 415V as required complete all as specified and directed. |
| 21 | S&F, entire drum assembly, consisting of round pipe, brackets, flange assembly, roller chains etc., automated with suitable motor and starter for lifting of capacity 1500 kgs Jielong rolling shutter complete kit complete all as specified and directed. |
| 22 | ADDITION / ALTERATION TO SMALL COMPRESSOR TEST FACILITY BLDG (P-56)Demolishing cement concrete padding in roof (unreinfoeced) including removal of existing roof treatment of any description and in any position roof not otherwise specially provided for and including removing debries to a distance exceeding 5 KM but not exceeding 15 KM outside MD land complete all as specified and directed. |
| 23 | Providing and laying cement concrete 1:2:4 type B0 (12.5 mm graded aggregate) in padding concrete over roof slab 25 mm average thickness complete all as specified and directed. |
| 24 | M&L for 15 mm thick rendering on fair faces of brick work or roof concrete surfaces in CM 1:3 and finishing the surface even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed.Note: WPC shall be measured and paid separately. |
| 25 | Supply only Water proofing liquidcomplete all as specified and directed. |
| 26 | M&L for mechanical cleaning of surface to make it free from any bituminous residue / dirt, oil and greeze etc., all as specified and directed by GE / Engineer-in-Charge.Cracks treatment by cutting open cracks and cleaning it from dirt / loose materials etc., and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge. |
| 27 | Applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in three coats including one coat of primer of same materials after dilution of water at 50% or specific primer matching same materials as per manufacturer specification and as directed by GE / Engineer-in-Charge.A layer of Geo textile grid of minimum 40 GSM sandwich in between two PU layers as per manufacturer\"s specification to be provided.Note: Work is to done by the authorised applicator of the manufacturer only as approved by GE. |
| 28 | Providing, supplying & applying of 4 component Inorganic-Organic IPN based self-smoothing 4 mm thick trowel applied flooring system, having Compressive strength between 38-40MPa as per ASTM D 579; tensile strength not more than 10MPa as per ASTM D 638; elongation not less than 3% as per ASTM D 638; abrasion resistance should not be more than 16mg loss by CS 17 wheel 1000 cycles, according to ASTM D 4060, flexural strength should not be less than 20 MPa as per ASTM D 790; shore D hardness minimum 75 as per ASTM D 2240; impact resistance between 9-10 N-m as per ASTM D 2794, scratch resistance value should be 8 Mohs scale as per ISO 13630. |
| 29 | All concrete must be crack free surface of M20 or above grade with moisture barrier placed under the RCC surface. All construction joints need to be cut within 24 hours of concrete placements. All expansion joints need to be sealed with PU sealant or equivalent, as recommended by manufacturer. All the fixation in the surface must be made prior to the application and treated. All the above process has to be undertaken by a manufacturer approved applicator. The surface must be clean, dry and sound concrete must be surface prepared using scarification & grinding. Apply base coat of 1 mm using Cipoxy 18 & DF 150 & allow it to cure for 6 to 8 hours. |
| 30 | Over the cured base coat apply 1 mm mid coat of IPN using trowel & allow it to cure. Over the cured mid coat apply 2 mm thick IPN top coat as per recommended shade so as to provide overall thickness of 4 mm. Including surface preparation by mechanical grinding / scarification or any suitable system as per base floor conditions to remove any loose material, contamination and cement laitance to provide a sound base and good adhesion surface, vacuum and manual cleaning of floor of all loose / dust particles, work shall executed by trained applicator of manufacturer associated with company more than 05 years and procedure should be followed as per manufacturers recommendations. |
| 31 | Providing and fixing false ceiling at all heights with 16 mm thick beveled regular mineral fibre false ceiling regular edged ceiling tiles 595 x 595 mm tile (NRC 0.55 to 0.60) of approved texture, design and patterns having NRC (Noise Reduction Coefficient) of 0.50 (minimum) as per IS 8225:1987, light reflectance of 85% (minimum). Non combustible as per BS:476 (Part-4), fire performance as per BS:476 (Part 6&7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary |
| 32 | Contd...stiched double webbed white with 6mm reveal profile (white / black), comprising of main-T runners of size 15 x 42 mm of length 3000 mm, cross - T of size 15 x 42 mm of length 1200 mm and secondary intermediate cross - T of size 15 x 42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm. Galvanised iron perimeter wall angle of size 22 x 19 x 0.40 mm of length 3000 mm to be |
| 33 | Contd…fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 34 | M&L for 25mm thick PCC 1:2:4 type B0 using 20mm graded aggregate as in bedding, finished fair and even complete all as specified and directed |
| 35 | Removing dry or oil bound distemper / exterior paint / cement base paint, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches and finishing walls with ready mixed premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance on old work (two coats) applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm dirt resistance exterior paint of required shade with silicon additives complete all as specified and directed. |
| 36 | S&F, aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kgs and fixed complete all as specified and directed. |
| 37 | S&F, 2 Levers aluminium Mortice lock, vertical type, size 100 mm fixed to aluminum door shutter complete all as specified and directed. |
| 38 | S&F, 100mm Butt hinges, medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 39 | S&F, 200 mm length, aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 40 | S&F, 150 mm aluminium handles, cast type, anodised complete all as specified and directed. |
| 41 | S&F, stainless steel material 202 grade soap dispenser, 800 ML capacity with wall-mounted plate, make sure it mounted tightly complete all as specified and directed. |
| 42 | S&F hand shower (health faucet) with 8 mm dia 1 mtr long flexible tube and wall hook chromium plated complete all as specified and directed. |
| 43 | M&L for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 44 | S&F, 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 45 | S&F, 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 46 | S&F, 75 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 47 | S&F, 75 mm dia PVC (SWR) couplers any radius complete all as specified and directed. |
| 48 | S&F, 110 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 49 | S&F, 110 mm dia PVC (SWR) junction single, (single T) equal or unequal complete all as specified and directed. |
| 50 | S&F, 110 mm dia PVC (SWR) couplers complete all as specified and directed. |
| 51 | S&F, 75mm PVC (SWR) vent cowl complete all as specified and directed. |
| 52 | REFRIGERATION AND AIR CONDITIONINGSupply, install, testing & commisioning of five star rated hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with latest invertor technology with hot & cold having ECO friendly refrigerent gas, copper condenser coil of capacity of 2 TR inculding all fixing arrangement (as requirment at site) complete all as specified and directed. |
| 53 | S&F, voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of + 2.5% of capacity 5 KVA complete all as spcified and directed. |
| 54 | Supply & laying of extra copper pipe of size 3/4\" with nitrile rubber tubular insulation and copper cable using necessary supports and fastners complete all as specified and directed. |
| 55 | Supply & laying of extra copper pipe of size 1/2\" with nitrile rubber tubular insulation and copper cable using necessary supports and fastners complete all as specified and directed. |
| 56 | M&L for MS stand duly painted suitable for fixing 2 TRAC outdoor unit and fixed complete all as specified and directed. |
| 57 | M&L for HDPE pipe 20 mm dia fixed to wall on roof complete all as specified and directed. |
| 58 | Making opening / drilling of size 65 mm dia using heavy duty stone driller / cutter machine in the stone machinery wall for installing spilt type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc., and making good the disturbed surface complete all as specified and directed. |
| 59 | Supply, install, testing & commisioning of three phase controlling unit to control the switching operation of air conditioners / exhaust fan in an alternative manner with PLC module. Rated current (In) of system is 63A at rated operational Voltage (Ue) of 415V AC with rated insulation voltage upto 500V AC voltage. Control unit shall have incomer with R, Y, B indications & all outgoing ckt shall have SCPD device in series with control devices. |
| 60 | Control unit enclosure shall be fabricated from CRCA sheet with sheet thickness of 1.6 mm, finished with impact-resistant grey epoxy powder coating shade RAL7032 with IP54 degree of protection & suitable for wall mounted installations. Enclosure of control unit shall have earthing bolts for safety purpose & shall have detachable gland plates with for entry of cables with pad type locking facility also. Control unit shall be manufactured in India at OEM plant & shall have QMS & EMS certifications like ISO-9001, ISO-14001 & ISO-45001 to ensure good quality product complete all as specified and directed. |
| 61 | LIGHTNING PROTECTIONM&L for aluminium strip 25 x 3.15 mm with saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and directed. |
| 62 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 03 Nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed. |
| 63 | EXTERNAL ELECTRIFICATIONSupply, install, testing & commissioning of HT 800 Amps, 11 KV, 18.4 KA, 3 Phase, 50 Hz 3 wire totally enclosed metal clad, extensible type indoor floor mounted horizontal draw, horizontal isolation type Vacuum Circuit Breaker 800 Amps motor operated spring charged having rupturing capacity 350 MVA and VCB comprising of: - (i) Assembly of 3 vaccum interrupters complete with epoxy support insulator and self-aligning finger type isolating contacts. |
| 64 | (ii) Hand and motor (220 volt AC) charged independent spring closing / tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical breaker closed / open, spring charged / discharged indication. (iii) Electrical release coil 24V DC- 01 No.(iv) Mechanical operation counter. (v) Breaker operated auxiliary switch - 03 Nos. (vi) Bus bar chamber including a set of 3 phase 8000 Amps copper bus bar - 01 No.(vii) 230 volts AC single phase 80 W rated strip type heater - 02 Nos with indicator complete. |
| 65 | (viii) Voltage transformer (VT) incorporating 3 phase 3 limb with drawable type VT having ratio 11KV/110V and output of 100 VA per phase with accuracy class I as per IS-3155 complete with HT & LT HRC fused in primary and secondary sides respectively (confirming related IS specification) - 02 set.(ix) Current transformer (CT) chamber incorporating 3 single phase resin cast, dual ratio CTS of ratio 400/5-5A class 1.0/5P10, burden 15VA-15VA with suitable VA burden and accuracy class. (x) Ammeter dual range with selector switch size 144 sq.mm 0-20/10A. |
| 66 | (xi) Triple pole non-directional IDMT relays having minimum 02 element for over current setting 50% - 200% and one element for earth fault protection setting 20% - 80% with instruments high set element - 01.(xii) On / Off / Trip indication - 01.(xiii) 3 Phase RYB indications with lamp & holder - 01 set with cable glands of suitable size.(xiv) Trip circuit healthy indication lamp with push button - 01 (xv) Power factor meter digital type - 01.(xvi) Frequency meter - 01.(xvii) Shunt trip 24 volts DC including maintenance free battery bank, battery charger including in quoted rate. |
| 67 | (xviii) In built integral earthing.(xix) Electronic, digital KWH meter CT type suitable for metering CT - 01 No.(xx) TNC Switch - 01.(xxi) Voltmeter with selector switch.(xxii) Potentioal transformer (PT) of 11kv, single phase, in door resin cast PT of ratio 11KV/rt3/110V/rt3/110V /rt3, class 0.5-3, burden 50VA-50VA.(xxiii) Rear cable termination provision for terminating 3 core 120 sq.mm XLPE cable. |
| 68 | M&L for sand cushioning to under ground cable providing with a layer 8 cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and directed.Note: Punned thickness only will be measured for the purpose of payment. |
| 69 | M&L for un-reinforced precast concrete covers class HV type 300 mm x 180 mm x 40 mm size factory made ISIS marked for cable protection complete all as specified and directed. |
| 70 | S&F, cable jointing kit 11 KV cable for indoor termination heat shrink type joint complete joint material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 Sqmm complete all as specified and directed. |
| 71 | Supply & laying synthetic insulating mat of size 2.00 mtr x 1.00 mtr x 2.5 mm thick suitable for upto 33KV grade complete all as specified and directed. |
| 72 | S&F, cable route indicator comprises and made out of PCC pole (0.3 x 0.3 x 1.5 mtr) on HT cable 1 mtr in depth grouted in the ground with suitable PCC 1:3:6 concrete base with writing HT cable / joint complete all as specified and directed. |
| 73 | Supply, laying & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade of size 3 core 120 Sqmm complete all as specified and directed. |