| 1 | Disconnecting, dismantling and taking out old U/S ACSR conductor of size 3 of 6/1 x 3.99 mm (Beaver) & 1 of 6/1 x 3.00mm (Ferret) out lived broken unserviceable includingremoving binding wire from insulators/jumpers complete all as specified and directed. |
| 2 | Dismantling & taking out old existing unserviceable steel and iron items from poles such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nut & bolts, washers of any description and in any position from HT over head line poles complete all as specified and directed. |
| 3 | Dismantling and taking out of old existing insulator any type and size from poles complete all as specified and direc ted. |
| 4 | Excavation in trenches in soft & loose soil not exceeding 1.5 meter deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers min 150 mtr away from site complete all as specified and directed. Note: Excavation shall be done carefully in order to avoid damages to existing cables and protection covers. |
| 5 | Returning, filling in,including spreading, leveling, watering and well ramming in layers of25 cm thick after the cables are laid, jointed & tested complete all as specified and directed. |
| 6 | M & L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying & stretching, jointing and testing the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured for payment purpose. |
| 7 | Taking down old HT cable of any size and any discription and keepingin the safe custody for reuse complete all as specified and as directed. |
| 8 | Supplying and laying precast concrete cable cover of size 300 mm x 180 mm x 40 mm, class HVP, Type-1 with peak complete all as specified and as direcetd. |
| 9 | Laying onlyprecast concrete cable cover any size and typecomplete all as specified and as direcetd. Note :- 690 Nos of Cable cover will be issued under Sch-\"B\" free for fixing and remainingwill be used from the usable cable cover obtained from Srl Item No. 2above. |
| 10 | Removal of surplus excavatedmaterial exc 250 m but not exceeding 500 m distance and depositing where directed complete all as specified and directed. |
| 11 | Laying, testing and commissioning XLPE cable of size 240 sqmm 3 core , insulated screened PVCbedded,galvanized steel strip or wire armored, electric power cables (heavy duty ) with stranded aluminum conductor, 11000 volts grade,including supply and fixingcable path indicators at distance of every 50 m duly marked with “MES HT Cable” all as specified and direcetd.Note :- Cable will be issued under schedule -B free for fixing. |
| 12 | Laying, testing and commissioning XLPE cable of size 150 sqmm 3 core,insulated screened PVCbedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 11000 volts grade, o including supply and fixing cable path indicators at distance of every 50 m duly marked with “MES HT Cable”all as specified and dirceted. Note :- Cable will be issued under schedule -B free for fixing. |
| 13 | Laying, testing and commissioningXLPE cable of size 120 sqmm 3 core, insulated screened PVCbedded, galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 11000 volts grade, including supply and fixing cable path indicators at distance of every 50 m duly marked with “MES HT Cable” all as specified and direcetd. Note :- Cable will be issued under schedule -B free for fixing. |
| 14 | Laying, testing and commissioningXLPE cable of size 95 sqmm 3 core , insulated screened PVCbedded,galvanized steel strip or wire armored, electric power cables (heavy duty ) with stranded aluminum conductor, 11000 volts grade,including supply and fixing cable path indicators at distance of every 50 m duly marked with “MES HT Cable” all as specified and direcetd. Note :- Cable will be issued under schedule -B free for fixing. |
| 15 | RelayingHT under ground cable of size 120 Sqmm 3 core complete all asspecified and direcetd. Note :- Cable obtained from Srl Item No. 7 above will be used for relaying. |
| 16 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable Straight through cold shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 240-400 sq mm complete all as specified and direcetd. |
| 17 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable Straight through cold shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 120-185 sq mm complete all as specified and direcetd. |
| 18 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable Straight through cold shrink outdoor type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 50-95 sq mm complete all as specified and direcetd. |
| 19 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable end joint cold shrink outdoortype joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 50-95 sq mm complete all as specified and direcetd. |
| 20 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable end joint cold shrink outdoor type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 120-185 sq mm complete all as specified and direcetd. |
| 21 | S&F cable Jointing kit Suitable for HT 11 KV grade (earthed) cable end joint cold shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured AI conductor cable of size 240 to 300 sq mm complete all as specified and direcetd. |
| 22 | M&L for Boring Horizontal holes of 150 mm dia of required length across the PCC/Bituminous road, hard standing etcby trenchless technology (without disturbing top surface) using ultra sounding technique by deploying required machinery including provision of HDPE pipe of 150 mm bore suitable for 0.4 MPa working pressure complete all as specified and directed.Note :- Cost of 150 mm dia HDPE Pipe shall be deemed to be included in quoted rate by the bidder. |
| 23 | Supply, installation, testing and commissioning of modular one side extendible 11 KV, 630 amp, 3 phase,50 Hz, outdoor type, SF 6 insulatedRing Main Unit / HT panel 4 way comprising of 02 number 630 ampLoad break switch (LBS) & 02 Nos Vacuum Circuit Breaker, with all required interlockings for functional and safety considerations as per site requirment incl provn of padlocking, suitable forambient temp -5OC to 500C mounted on MS angle platform of size not less than 75x75x6 mm, EC grade tinned copper bus bars mountedover epoxy / DMS insulators, copperflat earth bus bar (for earthingmetal clad, CB,LBS , MS angle), Air insulated metering module.All live parts of the switchboard likebus bars, LBSetc should be enclosed in robotically laser welded single stainless steel tank min 2.0 mm thick having IP 67 degree of protection with SF6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up ofgas,housed in min 2 mm CRCA outer enclosure, grit/shot blastedIP 54 confirming to IEC-62271-1(2017), IS 12729 : 1988 incl all latest amendments, painted inpolyurethane based powder paint overthermal spary of Zn alloy,Siemens grey shade RAL 7032 confirming to all relevant IS & IEC standards including the following items: |
| 24 | (a) LBS :Load Break Switch (LBS), HT 11 KV, with integral earth switch & fuse trip confirming to IEC 60129, IS 9920 and IS 9921 Indoor type 2.0mm thick CRCA MS Sheet enclosure, interlocked earth switch with following specification :- (aa) Rated system voltage 12 KV(ab) Rated current rating 630 amps(ac) Nominal System Voltage- 11 KV, 50 Hz, 3 pole(ad) One minute power frequency voltage withstand level-28 KV RMS (min)(ae) impulse voltage withstand level-75 KV peak (min)(af) Type of Insulation- SF6 (ag) Rated short time withstand current 21 KA/3sec (min) (ah) Rated short circuit making capacity-62.5 KA. (aj) Type of operating mechanism-Quick make, Quick break,manual spring assisted toggle.(ak) Interlocking : to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth / Main position (b)Vacuum Circuit Breaker:11 KV, 630 A, 3 Phase, 50 HZ, , 50 Hz, 3 phase indoor type,totally enclosed / metal clad switch gear , overload, earth fault and shortcircuit protection,Voltmeter range (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned inIS/IEC 62271 -100 & 200 /IS 13118 : 1991 incl latest amendments / additions.(ba) Push buttons for breaker ON/OFF. (bb) SCADA comaptible Self Powered Microprocessor based IDMT Relay (3 O/C + 1 E/F) with rechargeable battery with adjustable O/C and E/Felement current setting including 1 No voltage monitoring relay for under voltage / over voltage protection(bc) One minute power frequency voltage withstand level-28 KV RMS (min).(bd) impulse voltage withstand level-75 KV peak (min).(be) Rated Breaking Current : 21 KA (min) for 3 s(bf) Rated Making Current : 62.5 KA(bg) Mechanical and LED Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged |
| 25 | (bh) Dual core dual ratio Current Transformer (CT) chamber comprising of 3 Nos, single phase resin cast / ring core CTs of 300-150/5+5 Amps (incoming) and CTs of 200-100/5+5 Amps (outgoing), burden not more than 15 VA and accuracy class 0.5, for metering, having class 5P10 for protection as per IS:2705(bj) Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, Burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses /MCBfor primary and secondarycomplete all as specified and as directed as per IS: 3156 - 01 Set(bk) Earthing switch rated for full making capacity with provision for safe & reliable position indicator(c) Misc Provisions: Voltage Indication lamps for all 3 phases for each function of RMU (ca) LED bulb for illumination (cb) Space Heater with thermostat.(cc) One set of mechanical indicator for ON / OFF indication for all LBS / circuit breaker/Earth Switch, liveline indicator(cd) Go-No Go indication based on SF6 gas pressure(ce) Multifunction meter in all Circuit Breakers, Voltmeter in balance Note: 1.The tank shall be sealed and no handling of gas is required throughout the 20 years of service life. 2.RMU should be complete with all accessories such as dual core Ring CTs, potential transformers,manometer,voltage indications, mechanical indications for different position of LBS . 3 RMU shall bear guarantee for min 5 Years by OEM. 4.Foundation of RMU shall be provided all as per OEM instructions and cost of the same shall be deemed to be included in quoted rate. |
| 26 | Complete all as per Serial Item No 23, 23.01 & 23.02here-in-above butfor Ring Main Unit 5 way comprising of03 number 630 amp Load break switch (LBS) & 02 Nos Vacuum Circuit Breaker complete all as specified and directed. |
| 27 | Installation, Commissioning and testing HV Junction box panel board of KIOSK having bus bar size 50x6 mm AC, 50 Hz supply, outdoor cubical type, dust and vermin proof, pedestal mounting suitable shapeand size as approved by GE for 3 phase 11000 Volts , AC , 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitablesize to accomodate 01 incoming and 03 outgoing cables ( max 240 sq mm 3 core ) with spacing as per IE rulecanopy on top, made out of 3.15 mm thick MS sheet with using 25mm x 25mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete including locking arrangement andincluding PCC work for fixing panel all as per PS clause including bus bar of aluminium conductor suitable shape and sizefor 3 phase rating of 600 ampsIP-54 Protection. Note :- Item will be issued under Sch-B free for fixing. |
| 28 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing completeall as specified & directed by Engineer-in-Charge. NOTE: (i) The cost of earth lead and its protection pipe upto and including 7.5 mtrfrom the top of earth electrode are deemed to be included in quoted rate by the bidder.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 29 | Supplying , laying & jointing GI tubing of size 80 mm bore, light grade as in sleeving etc laid in treches/ducts/horizontal bore hole complete all as specified and direcetd. |
| 30 | Laying & jointing GI tubing of size 80 mm bore, light grade as in sleeving etc laid in treches/ducts/horizontal bore hole complete all as specified and direcetd.Note :-GI pipe for laying will be issued under schedule-B free for fixing. |
| 31 | Supplying , laying & jointing GI tubing of 100 mm bore light grade as in sleeving etc laid in treches/ducts/horizontal bore hole complete all as specified and direcetd. |
| 32 | Laying & jointing GI tubing, 100 mm bore light grade as in sleeving etc laid in treches/ducts/horizontal bore hole complete all as specified and direcetd. Note :-GI pipe for laying will be issued under schedule-B free for fixing. |
| 33 | Material and labour for point wiring for 15 Amps point using 2.5 sqmm FRLSH(nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and excluding concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.0 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with ISI marked phenol bondedlaminatedsheet coverof min 3 mm thick for housing of switches, sockets, regulators etc including all accessories andusing 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete including cutting chases in walls /floors for concealed conduit and making good the distrubed surface by cement mortor (1:3) and to match with the existing surface /colour by using existing oil bound distemper /white wash complete all as specified and directed.NOTE:(i)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid separately under appropriate item of Schedule `A\".(ii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers complete.(iii)The conduit pipe of size 20 mm dia will be issued under schedule- B free for fixing. |
| 34 | Supply & Fixing 4 Module gang box including Modular socket outlet 16 Amps for AC ,240 volts flush type white finish with on off push button ,flush mounted and LED indicator (RED) incl concealed point wiring on wallwith necessary arrangments with 4.0 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed standred copper conductor with and including PVC concealed conduit of medium grad with all fittings and Modular white cover plate with frame 4 module to accomodate all the accessories complete with internal connections ,fixed with chromium plate screws and washers for switches and sockets, including 4.0 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor as earth continuity conductor connected to common earth dollyincluding cutting chases in walls /floors for concealed conduit and making good the distrubed surface by cement mortor (1:3) and to match with the existing surface /colour by using existing oil bound distemper /white wash complete all as specified and directed |
| 35 | S&F switchsocket combination multi purpose, 6A/16A,5 in 1 flush type with fuse and neon indicator complete all as specified & directed |
| 36 | Supply and fixingsheet metal enclosure Double door for DB’s 4 way,240 volts with min 100 A rated bus bar for single phase and neutral supply complete fixed properly in concealed position and incl connecting theirincoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed. |
| 37 | S&F MCB single pole 32 Amps, \"B\" curve 10 KA ,240 Volts complete all as specified & directed. |
| 38 | S&F MCB Single pole and neutral 25 Amps, \"C\" curve 240 Volts complete all as specified & directed. |
| 39 | M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FRLSH of size 4 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 20 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLSH of size 4.0 Sqmm as earth continuity conductor all as specified and directed.NOTE:(i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.(iii)The conduit pipe 20 mm dia will be issued under schedule B free for fixing. |
| 40 | Excavating in post holes (or similar holes) each not exc 0.5 cum & getting out, returning, filling in and ramming earth around, in layers not exc 25 cm, in any type of soil complete all as specified and directed. |
| 41 | Material and Labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded stoneaggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 42 | M&Lfor posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing iron mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 43 | Supply only Chain link MS galvanised fencing of any size or type complete all as specified and directed. |
| 44 | Fixing only Chain link fencing including line wires of any mesh size and type and of any type of standards, rails, straining bolts, etc including provision of binding wires complete all as specified and directed. |
| 45 | S&F Mild Steel screw bolts (machine made) with hexagonal or square heads at one end and screwed at the other, to be fitted with washers and one hexagonal or square nut not exc 5 cm long & dia of neck 5 to 10 mm complete all as specified and directed. |
| 46 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 47 | M&L for steel gate of MS angle iron or bars including fixing to gate pillars with 02 Nos pintail hinges each side including locking arrangement conforming to Fe-410W complete all as specified and directed. |
| 48 | M & L for danger notice plate of size 25 cm x 20 cm made up of 1.6mm thick mild steel sheet, painted one side with vitreous enamelled white colour, with letters, figures and conventional skull and bones in signal red colour and fixed on HT Junction box with MS clamps, bolts and nuts of appropriate size complete all as specified and directed. |
| 49 | S&F CI cable route indicator at an interval 50 meter for already laid various sizes HT cable complete all as specified and directed. |
| 50 | M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) for making good to the road cutting carried out by the contractor complete all as specified and directed. |
| 51 | Testing and commisioning of HT cable of size 3 core 240 Sqmm already laid at site complete all as specifed and directed. |
| 52 | Testing and commisioning of HT cable of size 3 core 150 Sqmm already laid at site complete all as specifed and directed. |
| 53 | Testing and commisioning of HT cable of size 3 core 95 Sqmm already laid at site complete all as specifed and directed. |
| 54 | Taking out carefully HT cable of size 150 sqmm 3 core already laid in the ground and relaying the same after dressing of trench incl removal of excess deposited mud/debris complete all as specifed and directed. Note : - Sand and PCC cover will be paid separately under respective items. |
| 55 | Material and labour for checking and finding out pin point location of fault in existingHT XLPE 11 KV underground cable of size upto 240 Sqmm laid in trencheswith the help of fault locating High Tech mobile machine complete all as directed. Note : Charges for rent and transportation of the fault locating high tech mobile machine including DG Set, necessary earth work for repair HT cable, testing of cable after repair, charges for operator, engineer, electricians etc deemed to be included in the quoted rate. |
| 56 | Boring of holes under road/pavement/hard standing by mannual borring andincludinglaying/ insertion of GI pipe of 80 mm/100 mm dia completeall as specified and directed. Note : GI pipe will be measured and paid seperately under respective item. |
| 57 | Commissioning and testing of already installed HV Junction box panel board of KIOSK having bus bar size 50x6 mm AC, 50 Hz supply, outdoor cubical type, dust and vermin proof, pedestal mounting suitable shapeand size as approved by GE for 3 phase 11000 Volts , AC , 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitablesize to accomodate 01 incoming and 03 outgoing cables ( max 240 sq mm 3 core ) with spacing as per IE rulecanopy on top, made out of 3.15 mm thick MS sheet with using 25mm x 25mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete including locking arrangement andincluding PCC work for fixing panel all as per PS clause including bus bar of aluminium conductor of suitable shape and sizefor 3 phase rating of 600 ampsIP-54 Protection complete all as specified and directed.Note : Cost of Painting, locking arrangement and PCC work for fixing panel shall be deemed to be included in quoted rate by the bidder. |