| 1 | SCH \"A\" PART-I To XIIINote: This schedule ispre-priced by MES and the rate indicated under Col 5 signifies this fact only |
| 2 | Total amount of Sch \"A\" Part-I (Building and Structures) |
| 3 | Total amount of Sch \"A\" Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch \"A\" Part-III (Internal Water Supply) |
| 5 | Total amount of Sch \"A\" Part-IV (Internal Electric Supply) |
| 6 | Total amount of Sch \"A\" Part-V (Road, Paths & Culverts ) |
| 7 | Total amount of Sch \"A\" Part-VI (Sewage Disposal) |
| 8 | Total amount of Sch \"A\" Part-VII (Area Drainage) |
| 9 | Total amount of Sch \"A\" Part-VIII (Compound wall, Fencing and Gate) |
| 10 | Total amount of Sch \"A\" Part-IX (Retaining Wall) |
| 11 | Total amount of Sch \"A\" Part-X (External Water Supply) |
| 12 | Total amount of Sch \"A\" Part-XI (External Electric Supply) |
| 13 | Total amount of Sch \"A\" Part-XII (Hot Water Supply) |
| 14 | Total amount of Sch \"A\" Part-XIII (Rain Water Harvesting) |
| 15 | Total amount of Sch \"A\" Part-XIV (Demolition of Building) |
| 16 | SCHEDULE \"A\" PART-XV (MISCELLANEOUS B/R AND E/M WORKS) |
| 17 | S&F Double door Sheet metal enclosures factory made Vertical DBs 8 way TPN, 415 volts Concealed in Wall, protection class IP-43, suitable for fixing incoming MCCB and outgoing MCB DP/TPN etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCCBS/ MCBs DP/TPN will be measured and paid separately. |
| 18 | S&F Double door Sheet metal enclosures factory made Vertical DBs 6 way TPN, 415 volts Concealed in Wall, protection class IP-43, suitable for fixing incoming TPN and outgoing MCB DP/TPN etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCCBS/ MCBs DP/TPN will be measured and paid separately.MCCBS/ MCBs DP/TPN will be measured and paid separately. |
| 19 | S&F MCCB, 4P, AC, 415 Volts of 160 Amp capacity 16 KA, thermal and magnetic adjustable Ics=100% Icu, and making connections with suitable size of copper lugs etc complete all as specified and directed. |
| 20 | S&F MCCB, 4P, AC, 415 Volts of 100 Amp capacity 16 KA, thermal and magnetic adjustable Ics=100% Icu, and making connections with suitable size of copper lugs etc complete all as specified and directed. |
| 21 | S&F MCCB, 4P, AC, 415 Volts of 63 Amp capacity 16 KA, thermal and magnetic adjustable Ics=100% Icu, and making connections with suitable size of copper lugs etc complete all as specified and directed. |
| 22 | S&F LED Tubelight fitting 20 W extruded aluminium housing battens are equipped with high specification CISPR 15 compliant Electronic driver and milky white, special polycarbonate diffuser, for glare free efficient light distribution with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed. |
| 23 | S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitting 10 Watt with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed. |
| 24 | S&F energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V, 50 HZ etc complete all as specified and directed. |
| 25 | S&F Exhaust fan, PVC body AC single Phase. 230V of size 200 mm sweep with blades, and frame and louvers complete all as specified and directed. |
| 26 | M&L Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in CM 1:6, (d)15 mm internal and external plaster in CM 1:4, (e)3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments complete all as specified and as directed.(a) Internal Dimension 1200 mm x 1200 mm x 1000 mm |
| 27 | Cutting and tapping cast iron/ductile iron water mains, in position, for branch connections of the internal dia 80 mm complete all as specified and directed. |
| 28 | Supply & laying of DWC HDPE pipe ISI mark of outer dia 50 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed |
| 29 | Supply & laying of DWC HDPE pipe ISI mark of outer dia 120 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed. |
| 30 | Supply, Installation, Testing and Commissioning of step down transformer, outdoor type, and conforming to IS 1180:2014, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN - 11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus (-) 7.5% to plus (+) 7.5% in steps of 2.5%, continuous rating of capacity 160 KVA Level 3 including Cable entry box on HT Side, Cable entry box on LT side. The Transformer shall be completed with all standard fittings and accessories and first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :-Note - Transformer shall be mounted on platform/plinth.(a) One cable entry box on primary HV side having cable glands suitable for HT XLPE Cable (consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers).(b) One cable entry box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Thermometer pocket on tank cover. |
| 31 | (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.(g) Rating plate with terminal markings.(h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip.(j) Oil Level gauge.(k) Oil drain and filter valves.(l) Oil filler hole with cap/plug with connections complete.(m) Lifting lugs.(n) Air relief valve plug.(o) Four plan solid cast steel detachable rollers.(p) First fill of fresh oil conforming to relvant IS and tested upto 50 KV dielectric strength upto top of core.(q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral.(s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-1:2014. |
| 32 | Supply, Installing, Commissioning and Testing in replacement LT panel board, factory made, out door, cubical type, cubical type, vermin proof, dust proof, water proof, painted as per 7 tank processess & suitable for IP-56 protections, made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated aluminium busbar 500 amps capacity, 3 phase, 4 wire system, both sides openable (front and back), locking arrangement with CPRI approved, including cable trench duly painted with power coated with RAL 7032 internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories all as directed. (Main Panel)a) MCCB 315 Amp four pole with Breaking Cap 25 KA-01 No (Incoming)(b) MCCB, 200 Amps, with breaking cap 25 KA -01 Nos (For Living Accn)(c) MCCB, 63 Amps, with breaking cap 16 KA -01 Nos (For Cook house & Dining Hall)(d) MCB 32 Amps, with breaking cap 16 KA-01 (For Street Light)(e) MCB 32 Amps, with breaking cap 16 KA-01 (For Spare)(f) Multifunction meter digital type)-01 No(g) Phase indication lamps LED type with holder-01 Set(Set of Three) |
| 33 | (h) Timer Switch with connected accessories for on/off for Street Light(Notes: The rates quoted shall include for earth work and excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil and PCC 1.4:8 TYPE D2 filling in foundation. The ground clearance of panel board shall be 0.40 m from GL to the bottom of panel board) |
| 34 | S&F Vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements, suitable for 11000 volts, 200 Amps current rating complete including dismantling existing one all as specified and as directed. |
| 35 | S&F new street light fitting (LED) of capacity 60 W, 6000-6500 Lumen- 6000 Lm, 10 KV in build surg protection IP-66, die cast aluminium housing and 4 Sqmm service wire for necessary connection etc complete all as specified and directed. |
| 36 | S&F PVC Junction box of size 200x175x100mm, IP 66 with hinged door including locking arrangement and MCB SP 6 Amp with necessary nut, bolt etc and including TPN aluminium bus bar mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB compete all as specified and directed. |
| 37 | Supplying, Installing, Connecting, Testing and Commissioning Storage Water Cooler 80 litre capacity and cooling capacity 40 litres per hour, based on eco friendly gas R-134a refrigerant including extending the drain out pipe to the nearest drain system complete all as specified and directed. |
| 38 | S&F Desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size). Plastic/PVC body complete all as specified and directed. |
| 39 | Supplying, Installing, Connecting, Testing and CommissioningRefrigerator electric driven (Single Phase) of capacity 300 litres, 220 volts, 50 Hz, BEE 5 Star rated based on eco friendly gas complete all as specified and directed. |
| 40 | Supply, Installation, Commissioning of Metal Top Deep Freezer 400 litre capacity having double door, single phase 240 volt, 50 Hz complete all as specified and directed. |
| 41 | Supplying, Installing, Connecting, Testing and Commissioning Digital copper wound automatic Voltage Stabilizer for automatic operations, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with out put voltage stabilized at 230 volts with accuracy of (±) 2.5% and capacity 1 KVA complete all as specified and directed. |
| 42 | Supplying, Installing, Connecting, Testing and Commissioning Digital copper wound automatic Voltage Stabilizer for automatic operations, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with out put voltage stabilized at 230 volts with accuracy of (±) 2.5% and capacity 2 KVA complete all as specified and directed. |