| 1 | Dismantling timber scantling 40Sqcm and over in section as in unframed workin any position complete all as specified and as directed. |
| 2 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 4 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cmthick ( Below or above ground)complete all as specified and directed. |
| 5 | M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed. |
| 6 | M&L for 100mm thick cement concrete (1:2:4) type, B1 (using 20mm graded crushed stone aggregates) as in floor surfaces even and smooth without using extra cement, complete all as specified and as directed. |
| 7 | M&L for forming 12mm thick Expansion joints forthickness of concrete slab 100mm,filled with pre-formed bituminousfiller and top 30mm primed and sealed with sealing compound, Grade ‘A, complete all as specified and directed. |
| 8 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A, joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed. |
| 9 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 10 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 11 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A,Plates(plain or chequered) channels,square cut or notched (ordinary and counter sunk) with riveted, bolted or welded attachment, complete all as specified and directed. |
| 12 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed. |
| 13 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and directed. |
| 14 | M &L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valleycomplete all as specified and as directed. |
| 15 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 16 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 17 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFR-LSH cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 18 | All as per item serial No 17 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. |
| 19 | S & Fswitch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 20 | S & Fswitch socket combination, multipurpose, 2 in 1, 3 pin, 15 & 16 Amp flush type complete all as specified and as directed. |
| 21 | S & Fceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 22 | S & F in repairLED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube lightand connecting up withthree core flexible copper conductor cable of suitable size from ceiling rose, complete all as directed. |
| 23 | S & F in repairs LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completionand including suitable size of bracket with accessories, complete all as specified and as directed. |
| 24 | S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 25 | S&F MCBs, SPN/DP 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 26 | S&F MCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 27 | M&L for house service GI bracket(Hook type) made out of 40 mm bore medium grade GI Pipe of length 3m andone No 90 degree bendfixing withclamps, nuts and bolts, MS hooks,stay etc,including dismantling old onecomplete all as specified and as directed. |
| 28 | S&F 1100 volts grade heavy duty flat cable ofsize 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 29 | M&L for Sub main wiring with 2 runs of 1.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note :For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as \"1RM\". |
| 30 | M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I and including taking down of old ones, complete all as specified and directed. |