| 1 | Dismantling timber scantling 40Sqcm and over in section as in unframed workin any position complete all as specified and as directed. |
| 2 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 4 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cmthick ( Below or above ground)complete all as specified and directed. |
| 5 | M&L for 25mm thick cement concrete (1:2:4) type, B0 (using 12.5 mm graded crushed stone aggregates) as in sub base receiving floor finishes, complete all as specified and as directed. |
| 6 | M & L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layers in 15mm thick screed bed in cement motar 1:4, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed. |
| 7 | M & L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and includingscreed bed or bedding layers in 10mm thick screed bed in cement motar 1:3, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed. |
| 8 | Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed. |
| 9 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed. |
| 10 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 11 | S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in & including a grid of GI system duly suspended with 4mmdia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm gridcomplete all as specified and as directed. |
| 12 | S&F solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 13 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 14 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work complete all as specified and as directed. |
| 15 | M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 16 | M&L for preparation of old wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamelcomplete all as specified and as directed. |
| 17 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 18 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture\"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as \"Supply only\". |
| 19 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 20 | Supply only integral water proofing compound complete all as specified and as directed. |
| 21 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat ofprimer complete all as specified and as directed. |
| 22 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 23 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A, joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed. |
| 24 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 25 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and irected. |
| 26 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A,Plates(plain or chequered) channels,square cut or notched (ordinary and counter sunk) with riveted, bolted or welded attachment, complete all as specified and directed. |
| 27 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 28 | M&L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed. |
| 29 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed. |
| 30 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and directed. |
| 31 | M &L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valleycomplete all as specified and as directed. |
| 32 | M &L 0.63mm thick plain, galvanised, mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut)complete all as specified and as directed. |
| 33 | Taking down shutters of any description n exc 1 sq. m each complete all as specified and as directed. |
| 34 | Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m eachcomplete all as specified and as directed. |
| 35 | S&F Powder Coated (minimum thickness of powder coating 50 micron) of aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and asdirected |
| 36 | S&F three track Powder Coated (minimum thickness of powder coating 50 micron) aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per standard engineering practices including all other accessories complete like 5mm thick glass panes, rubber beading etc complete all as specified and as directed. Aluminium section A series are as under:-(i) Shutter bottom& top :-37.5x15x1.3mm thick(ii) Shutter interlock :- 37.5x23x1.3mm thick(iii) Shutter side(Handle):- 37.5x23x1.3mm Thick(iv) Frame bottom 75x26x1mm thick(v) frame top and sides:175x26x1mm thick. |
| 37 | S & F Powder Coated (minimum thickness of powder coating 50 micron) aluminium door shutters,aluminium section weighing 0.55 kg/m including necssary joining cleats,glazing clips,ruber neoprene packing, handle 2 Nos in Each door, hinges, anodised aluminium snap bidding, screw etc. complete all as specified and directed. |
| 38 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around theopening, all complete as per requirement and direction of Engineerin-charge. |
| 39 | S & F 5.5mm thick sheet glass, ordinary quality andsquare n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 40 | S & F 5.5mm thick sheet glass, ordinary quality andsquare exc 0.5 sqm in each pane complete all as specified and as directed. |
| 41 | Demolition of Concrete of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. |
| 42 | M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed. |
| 43 | S&F in repair harrison rails of 19/20mm dia, mild steel cromimum platedwith fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 44 | S & F prelaminated particle board 18/19mm, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in pelmet boxcomplete all as specified and as directed. |
| 45 | M&L 2nd class hardwood, weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixedincluding taking out old ones of any description complete all as specified and as directed. |
| 46 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 47 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFR-LSH cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 48 | Allas peritem serial No 47 here-in-before but for One 3 pin 5 Ampsocket combination on independent board with other switches. |
| 49 | All as per item serial No 47 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. |
| 50 | S & Fswitch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 51 | S & F switch socket combination outlet 3 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed. |
| 52 | S & Fswitch socket combination, multipurpose, 2 in 1, 3 pin, 15 & 16 Amp flush type complete all as specified and as directed. |
| 53 | S & Fceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 54 | S & F in repairLED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube lightand connecting up withthree core flexible copper conductor cable of suitable size from ceiling rose, complete all as directed. |
| 55 | S&F in repairs LED luminaire of size 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roo ceiling including connecting up with driver three core flexible copper conductor of suitable size, complete all as specified and as directed. |
| 56 | S & F in repairs LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completionand including suitable size of bracket with accessories, complete all as specified and as directed. |
| 57 | S & F in repairsLED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 58 | S & F in repairs track mounted LED light with modern design, compact size with high power COB LED to provide focussed light, including mounting accessories with connection etc, complete all as specified and as directed. Make:Havells, Cat No.UNECOTRACKLIGHTTS10WLED830S15WHT/BAJAJ/JAQUAR/PHILIPS/ORIENT/SURYA |
| 59 | S & Fexhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. |
| 60 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 61 | S&F MCBs, SPN/DP 40 to 63 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 62 | S&F MCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 63 | M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. |
| 64 | M&L for Sub main wiring with 2 runs of 10.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note for Item No 63&64:For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as \"1RM\". |
| 65 | M&L for house service GI bracket(Hook type) made out of 40 mm bore medium grade GI Pipe of length 3m andone No 90 degree bendfixing withclamps, nuts and bolts, MS hooks,stay etc,including dismantling old onecomplete all as specified and as directed. |
| 66 | S&F 1100 volts grade heavy duty flat cable ofsize 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 67 | M&L for plate earthing completewith copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and connected to 20x3mm copper strip as earthing lead by means of clamps, bolts, nuts and washer made of galvanised iron or steel and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work and including taking down of old ones, complete all as specified and directed. |
| 68 | M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I and including taking down of old ones, complete all as specified and directed. |