| Sl. No. | Item Description |
| 1 | Notes :Please refer schedule \"A\" notesbefore quoting the tender.INTERNAL ELECTRIC WORKS |
| 2 | Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits includingcomplete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets,electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed. |
| 3 | M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including casing caping of 25 mm wide double locking type, ISI marked including all accessories as approved with PVC 1.5 sqmmmulti stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out ofsuitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be concleadin wall, duly painted including 3mm hylum /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer for one light, fan point, one way complete all as specified and directed. Note : Wiring to be done as per arroved colour code. |
| 4 | All as per BoQ Serial Item No.1.02 above but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts |
| 5 | All as per BoQ Serial Item No.1.02 above butt one 5 amp socket point on same board |
| 6 | All as per BoQ Serial Item No.1.02 above but one 5 amp multi socketindepenedent |
| 7 | All as per BoQ Serial Item No.1.02 above but using 2.5 sqmm (nominal area) multistranded FRLSH copper conductor cable/wire& 2.5 sqmm size PVC insulated unsheathed FRLSH copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Ampswitch, SP one way, 240 Volts & Socket, complete all as specified and directed. |
| 8 | All as per BoQ Serial Item No.1.02 above but using 4 sqmm (nominal area) multistranded FRLSH copper conductor cable/wire for one 5/15 Amp socketpoint controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed. |
| 9 | S&F switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed. |
| 10 | S&F Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed. |
| 11 | S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed. Note : This item shall also be used as in repairs of existing 6 Amp socket outlet. |
| 12 | S&F Switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked)complete all as specified and directed. |
| 13 | S&F Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed. |
| 14 | M&L for Submain wiring in repairs with two runs ofsingle core, 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earthand connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 15 | M&L for Submain wiring in repairs with two runs ofsingle core 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts gradeusing color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and ,connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 16 | M&L for Submain wiring in repairs with two runs ofsingle core 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly complete all as specified and directed. |
| 17 | M&L Submain wiring repair/replacement with two runs ofsingle core 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly all specified and directed in charge. |
| 18 | M&L Submain wiring repair/replacementwith two runs ofsingle core 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including stove steel enameled conduit 20/25mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly all specified and directed in charge. |
| 19 | M&L for Submain wiring in repairs with two runs ofsingle core 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and includingin existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly all specified and directed in charge. |
| 20 | M&L for Submain wiring in repairs with two runs ofsingle core 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and includingstove steel enameled conduit 20/25 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly all specified and directed in charge. |
| 21 | M&L for Submain wiring in repairs with two runs ofsingle core 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts gradeusing color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly complete all as specified and directed. |
| 22 | M&L for Submain wiring in repairs with two runs of single core 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including stove steel enameled conduit 32 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 23 | M&L for Submain wiring in repairs with two runs ofsingle core 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts gradeusing color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 24 | M&L for Submain wiring in repairs with four runs ofsingle core 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 25 | M&L for Submain wiring in repairs with four runs ofsingle core10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor 1100 volts grade using color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etccomplete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed. |
| 26 | M&L for Sub main wiring in repairs with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduitof 25mm dia/casing capping/ suitable size , ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed. |
| 27 | M&L for Sub main wiring in repairs with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed. |
| 28 | M&L for Sub main wiring in repairs with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete complete all as specified and directed. |
| 29 | M&L for Sub main wiring in repairs with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduitof 20mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed. |
| 30 | M&L for Sub main wiring in repairs with two runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 1.5 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduitof 20mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 1.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed. |
| 31 | M&L for Sub main wiring in repairs with TWO runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed. |
| 32 | M&L for Sub main wiring in repairs with four runs ofsingle core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm(with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI markedincludingone run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed. |
| 33 | S&F in repairs flame proof LED well glass hanging type 60w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for fixing to any height complete. |
| 34 | S&F in repairs flame proof LED well glass hanging type 100w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for fixing to any height complete. |
| 35 | S&F in repairs HIGH BAY LED lights hanging/ceiling mountingtype 100w fitting with PC diffuser with surge protectionon existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for fixing to any height complete. |
| 36 | S&F in repairs LED recess/surface mounted 2\"x2\" luminarie, 36/40w fitting, 220V,AC, 50 Hz,suge protection, high power factor complete all as specified and directed. |
| 37 | S&F in repairs Low BAY LED lights hanging/ceiling mountingtype 40w fitting with PC diffuser with surge protectionon existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for fixing to any height complete. |
| 38 | S&F in repairs FLP plugin switch socket 16A, 3pin (2P+E), 220V, 50 Hz, AC and fixing arrangement complete all as specified and directed. |
| 39 | S&F in repairs FLP plugin switch socket 25A, 3pin (2P+E) , 220V, 50 Hz,AC and fixing arrangement complete all as specified and directed. |
| 40 | S&F in repairs FLP plugin switch socket 32A, 5pin (4P+E), 50 Hz, AC and fixing arrangement complete all as specified and directed. Make: Shyam switch Gear/SSPLRI/146 or Sudhir Cat Part No RI/A/146-3 or equivalent of Baliga as approved by GE. |
| 41 | S&F in repairs FLP LED Typetube light fitting 1 X 20 watt, four feet, 220V, 50 Hz, AC and fixing arrangement complete all as specified and directed. Make: Shyam switch Gear/SSPLRI/146 or Sudhir Cat Part No RI/A/146-3 or equivalent of Baliga as approved by GE. |
| 42 | S&F in repairs FLP LED Typetube light fitting 2 X 20 watt ,four feet, 220V, 50 Hz, AC and fixing arrangement icomplete all as specified and directedcomplete all as specified and directed by Engr-in-Charge. |
| 43 | S&F in repairs FLP TPN DB 4 way, 220V, 50 Hz, AC and fixing arrangement incomer MCB 4P 63amp/100 Amp and outgoing MCB SP, 12 nosbus bar 200 Amp complete all as specified and directed. |
| 44 | S&F in repairs FLP SPN DB 12 way, 220V, 50 Hz, AC and fixing arrangement incomer MCB 2P and outgoing MCB SP 10 NOsbus bar 100 Amp complete all as specified and directed. |
| 45 | S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 46 | S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA,415 Volts, 50 Hz, complete all as specified and directed. |
| 47 | S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA,415 Volts, 50 Hz, complete all as specified and directed. |
| 48 | S&F in repairs MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA,415 Volts, 50 Hz, complete all as specified and directed. |
| 49 | S&F in repairs 6 to 32 AMP MCB single pole 240 V 10 KA(C-Series) complete all as specified and directed. |
| 50 | S&F in repairs 32 AMP MCB SPN 240 V 10 KA(C-Series) complete all as specified and directed. |
| 51 | M&L for checking ceiling fan of size 1200/1400mm and changing defective parts cotter pin/ nut bolt etc including taking down and refixing complete all as specified and directed. |
| 52 | M&L for cutting of wall/ceiling/column for laying submain/ cable of any size including making good existing surface complete all as specified and directed. |
| 53 | S&F in repairs fan rodof size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm complete all as specified and directed. |
| 54 | S&F in repairs capacitor of 2.5 mfd complete all as specified and directed. |
| 55 | S&F in repairs capacitor of 4.0 mfd complete all as specified and directed. |
| 56 | M&L for copper Rewinding of ceiling fan 1200/1400mm as per existing complete all as specified and directed. |
| 57 | M&L for checking Exhaustfan of size 250/300/450mm and changing defective parts including taking down and refixing complete all as specified and directed. |
| 58 | M&L for copper Rewinding of Exhaust fan 250/300/450mm as per existing complete all as specified and directed. |
| 59 | M&L for checking wall mounting fan of size 300/450/600mm and changing defective parts including taking down and refixing complete all as specified and directed. |
| 60 | M&L for copper Rewinding of wall mounting fan of size 300/450/600mm as per existing complete all as specified and directed. |
| 61 | M&L for checking Pedastal fan of size 300/450/600mm and changing defective parts including taking down and refixing complete all as specified and directed. |
| 62 | M&L for copper Rewinding of Pedastal fan of size 300/450/600mmfan of size 300/450/600mm as per existing complete all as specified and directed. |
| 63 | S&F in repairs LED batten with 38/40W LED tube light, four feet box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, complete all as specified and directed. |
| 64 | S&F in repairs LED batten with 20/22W LED tube light (4\"), 220V, AC, 50Hz in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc, suge protection, high power factor, Surface and wall mounted LED batten,complete all as specified and directed. |
| 65 | S&F in repairs LED batten with 38/40W LED tube light six feet box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, complete all as specified and directed. |
| 66 | S&F in repairs round/square type, recessed /surface 12W/14W warm /white LED downlight dimmable with high lumen 230V, complete all as specified and directed. |
| 67 | S&F in repairs switch piano flush button single pole one way, 6 Amp (ISI marked)complete all as specified and directed. |
| 68 | S&F in repairs Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked)complete all as specified and directed. |
| 69 | S&F in repairs Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed. Note : This item shall also be used as in repairs of existing 6 Amp socket outlet. |
| 70 | S&F in repairs Switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed. |
| 71 | S&F in repairs Socket type EME fan 5 step regulator for ceiling fanof suitable size complete all as specified and directed. |
| 72 | S&F in repairs modular step type fan regulator, 120W, AC,50Hz complete all as specified and directed. |
| 73 | S&F in repairs modular switch 1 module 6 amp one way ISI marked complete all as specified and directed. |
| 74 | S&F in repairs modular switch 1 module 16 amp one way complete all as specified and directed. |
| 75 | S&F in repairs modular socket 2 moduleuniversal type 5/6 amp one way complete all as specified and directed. |
| 76 | S&F in repairs modular socket 2 moduleuniversal type 15/16 amp one way complete all as specified and directed. |
| 77 | S&F in repairs modular bell push 6A 1 module complete all as specified and directed. |
| 78 | S&F in repairs ceiling rose three terminal complete all as specified and directed. |
| 79 | S&F in repairs LED tube rod 20 watt, 220V, 50Hz, AC complete all as specified and directed. |
| 80 | S&F in repairs FLP junction box 4 way 100mm including all connected accessories complete all as specified and directed. |
| 81 | S&F in repairs double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way complete all as specified and directed. |
| 82 | S&F in repairs double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way complete all as specified and directed. |
| 83 | S&F in repairs double door MCB VTPN DB 8 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 waycomplete all as specified and directed. |
| 84 | S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door open able,complete all as specified and directed. |
| 85 | S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door open able complete all as specified and directed. |
| 86 | S&F in repairs PCB of BLDC fan of any size complete all as specified and directed. |
| 87 | S&F in repairs remote of BLDC fan of any type complete all as specified and directed. |
| 88 | S&F in repairs sunken/terminal box of size 10x10cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed. |
| 89 | S&F in repairs sunken/terminal box of size 15x7.5cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed. |
| 90 | S&F in repairs sunken/terminal box of size 20x15cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed. |
| 91 | S&F in repairs sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed. |
| 92 | S&F in repairs modular cover plates with frame up 1 /2 module to 3 module as per site requirements (apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in) complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs |
| 93 | S&F in repairs modular cover plates with frameup 4 to 12 module as per site requirements (apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in) complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs |
| 94 | S&F in repairs modular metal flush box as per site requirements 1/2 modules to 3 module complete all as specified and directed. NOTE- Metal flush boxesconsidered in this item only for the maintanance of switches of existing modular fitting qtrs |
| 95 | S&F in repairs modular metal flush box as per site requirements 4 modules to 12 modulecomplete all as specified and directed. NOTE- Metal flush boxesconsidered in this item only for the maintanance of switches of existing modular fitting qtrs |
| 96 | M&L for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1, using (20 mm graded stone aggregates) mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mmthick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion complete all as specified and directed. |
| 97 | S&F in repairs FLP FLEXIBLE metalic pipefor 19/20 mm dia complete all as specified and directed. |
| 98 | Supply & fixing, jointing, connecting & testing intrenches XLPE/PVC insulated PVC sheathedcable heavy duty1100 volts grade, 10 sqmm, 2 core aluminum conductor in trenches / ducts/ including taking out cable cover & cable complete all as specified and directed. |
| 99 | S&F in repairsFLP FLEXIBLE metalic hose conduit 1000 mm long for 19/20 mm dia fcomplete all as specified and directed. |
| 100 | S&F in repairs FLP rotary switch single pole 10/16 Amps and fixing arrangement complete all as specified and directed. |
| 101 | S&F in repairs LED flame proof bulk head fitting 45w complete all as specified and directed. |
| 102 | S&F in repairs flame proof LED flood light 100w fitting of Sudhir switchgears or equivalent in shyam/balinga, fitted on wall surface complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items. |
| 103 | SS&F in repairs LEDbuilding security light 45 watt with hanging arrangement in wall/surface/ceilingconnecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, complete all as specified and directed. |
| 104 | M&L for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults complete all as specified and directed |
| 105 | S&F in repairs GI pipe light grade with all fittings complete laidin trenches complete all as specified and directed. |
| 106 | S&F in repairs flexible wire 1 sqmm X 2 core complete all as specified and directed. |
| 107 | S&F in repairs modular type AC boxwith three pin socket and plug top and 20 amp single pole MCB complete all as specified and directed . |
| 108 | S&F in repairs two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB complete all as specified and directed . |
| 109 | BR WORKS |
| 110 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specifedand directed |
| 111 | Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (posts embedded in in concrete, brick work, masonry work, etc.) complete all as specified and directed. |
| 112 | Dismantling fencing wire mesh any type complete all as specified and as directed |
| 113 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 114 | S&F steel work as in tubular trusses including special shaped washer etc completeusing ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all specified and directed. |
| 115 | S&F for rolled sections of FE 410W (Gde-E-250)as in main and cross beams, hip and jack rafters; purlins where connectedto common rafters and running rails and guides for sliding doors; fixedwithangle cleats, Steel Door frame and shutter or other connecting plates complete all specified and directed. |
| 116 | S&F framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls complete all as specified and directed. |
| 117 | S&F MS plate Fe 410-W (Gde E-250 quality A)(Plane/Chequered)5 mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed. |
| 118 | Excavating in post holes (or similar holes) in any type of soil, each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 119 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire mesh, etc.; flat iron fillets( for securing wire mesh etc.) including all necessary drilling, bolting or riviting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 120 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but, length of boltexc 5cm but n exc 10cmlong.(Diameter of neck in 11 to 15 mm) complete all as specified and directed |
| 121 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismanlting of old Sheet as specified etc complete all as specified and directed. |
| 122 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedetc complete all as specified and directed. |
| 123 | Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and M&L for applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome complete all as specified and as directed. |
| 124 | S&F mild steel security chain link fencing 60mmx60mm with PVC coated mesh made out of 3.0 mm dia MS wire and 1.00mm thick PVC complete all as specified and directed. |
| 125 | Taking down and refixing of chain link fencing in same position after replacing of damaged fencing post complete all as specified and directed. |
| 126 | Taking down existing angle iron from wall embadded in PCC and refixing in the same opening/position complete all as specified and directed. |
| 127 | M&L for cement concrete C-2 1:3:6 using 40mm graded stone aggregates as in foundation, filling and mass concrete, in fencing pole complete all as specified and directed. |
| 128 | Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and M&L for applying two coats of synthetic enamel paintover & including a coat of red oxide zinc chrome complete all as specified and as directed. |
| 129 | M&L for cement concrete type D-2 1:4:8 using 40mm graded stone aggregates asin foundation, filling and mass concrete etc complete all as specified and directed. |
| 130 | M&L for chequered cement concrete tile 30cm X 30cm X 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pigments over & including 20mm thick screed bed or bedding layer of CM (1:4)includingdismentling of old tiles complete all as specified and as directed. |
| 131 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade includingdismentling of old tiles complete allas specified & directed . |
| 132 | M&L forMachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade includingdismentling of old tiles complete allas specified & directed. Note:- Sand Cushion will be paid seperately. |
| 133 | Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand caushion for maintaing camber and slope complete all as specified and directed. Note:- Sand Cushion will be paid seperately. |
| 134 | M&L for sand cushioning for laying interlocking paver block complete all as specified and directed. |
| 135 | S&F green marble 18-20 mm thick machine cut, jointing and pointing with white cement slurry with & including 20mm thick screed bed or bedding layer of mortar in CM 1:6includingdismentling of old stone slab / tiles complete all as specified and directed. |
| 136 | M&L for 75 mm thick cement concrete type C-1 (1:3:6) using 20mm graded stone aggregate as in plinth protection finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed |
| 137 | M&L for 100mm thick cement concrete type B-2 (1:2:4) using 40mm graded stone aggregate as in path/floor finished fair even and smooth without using extra cement, laid in alternate panels of size not exc 4 sqm each including bitumen filling in joints complete all as specified and directed. |
| 138 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 139 | M&L for pre-cast cement concreteblock masonry with solid blocks, exc. 10 cm in width in type B1 (1:2:4)(20mm graged stone aggregate )and setting in mortar (1:6)including demolition of old PCC Block complete all as specified and as directed |
| 140 | M&L brickwork with sub class \"B\" bricks, straight or curved on planexc 6m mean raidus built in cement mortar 1:6 including demolition of old brick work complete all as specified and directed |
| 141 | M&L for rendering 15 mm thick in CM 1:4on fair faces of brick/concrete surfaces in two coats ( i.e 10 mm thick backing coat and 5mm thick finishing coat) finished even and smooth complete all as specified and directed.(Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.) |
| 142 | M&L for rendering 10 mm thick in CM 1:6 on fair facesof brick work or concrete surfaces finished even and smooth complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.) |
| 143 | M&L for PCC (1:2:4) type B0 (using 12.5mm graded stone aggregates) as in coping bed black etc including nessesary form work complete all as specified and directed. |
| 144 | S&F Steel rolling shutters, with out ball bearing, thickness of laths 1.00mmas specified including top cover, anchoring rod, hasp and staple and erected in position as indicated,complete: push pull or manual type including taking down of old Shutter complete all as specified and directed. |
| 145 | Preparing new or previously untreatedsteel surface of any decription over 10cm in width or girth and M&L for applying 2 coats of aluminium paint over & including one coat of red oxide primer complete all as specified and directed. |
| 146 | Preparing old painted steelsurface of any decription over 10cm in width or girth and M&L for applying one coat of aluminium paint complete all as specified and directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail