| 1 | ( M & L ) Rendering 15 mm thick on fair faces of brick work or concrete surface with cement plaster 1 : 4, finishing even and smooth without using extra cement, all as directed byEIC/SIC, Note- Water proofing compound will paid and measured separately. It may be applied till 1st floor outer/inner wall (Hight 10 Meter), including Scaffolding all as directed by SIC & EIC. |
| 2 | S&F Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm complete, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete and M&L 4 mm thick Gypsum board self imbosed texture Sqm boards, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling all as specified by EIC & SIC. |
| 3 | S/F Solid PVC /UV marble Wall Lining sheet consisting of 5mm thick wood grain single side prelam PVC sheet used instead of plain sheet and fixing at site as per requirement with provision of decorative laminate type 1 of surface finish 0.9 mm thick, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instruction |
| 4 | S & FProviding and fixing factory made uPVC white color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware anddrainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thickgalvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.] (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. |
| 5 | Demolition of Cement concrete in any position (unreinforced) of any description and |
| 6 | M&L for Virified Ceramic tiles (Double Charged/ultracharged)10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as directed by EIC & SIC |
| 7 | ( M & L ) 3mm thick cement base wallcare putty on wall and as directed by EIC/SIC. |
| 8 | (M&L) 2 coats Plastic Emulsion paint Surfaces of any description over 10cm girth or width, not otherwise described with prepration for exterior surface. |
| 9 | M/L Partition work with block boards, grade 1 quality,25 mm wih decorative laminate 0.9 mmthick type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as,; fixed with screws to timber frame work including all assessary/hardware. |
| 10 | M/L Granite (of any type) 20mm thick , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete |
| 11 | Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces |
| 12 | Removing excavated material (rubish/rocks) beyond 500 m and upt total distance of 1.5 Km and depositing where directed including loading, unloading and stacking at the destination. |
| 13 | i) Preparation of the surfaces of the roof by cleaning with wire brush, removing old treatment, if any.ii) Brooming with Broom and finally sweeping with gunny bag.iii) Cutting the joints in ‘V’ shape and filling them with 1:3 cement sand mortar and allowing them for curing for 03 days.iv) Filling the thin grooves with hot bitumen and allowing them to dry.v) Applying a coat of hot bitumen of grade 85/25 @ 1.20 Kg/Sq.m. over the area even and smooth.vi) Unrolling the roll ofPolymeric waterproofing membrane over the coated surface and press smoothly to bond completely with the surface and no air bubble should be left under the membrane. The lap should be not less than 10 cm both horizontaly and vertically. The lap will not be measured separately.vii) Lap should be sealed with flame and blown bitumen thereafter.viii) Applying the IInd layer of the hot bitumenof grade 85/25 @ 1.20 Kg/Sqm. even and smooth on the polymeric membrane. ix) Removing the debris off the campus.,x) Specification of the Polymeric membrane.a) The center core of the membrane should be 90 micron, withhigh molecular/high density Polythelene film provided both side with SBS/APP polymer modified bitumen with properties of high softening point., b) Top layer and bottom layer- Therofusible high molecular/high density polythelene film.c) Elongation- More than 300%, d) Weight-3.00Kg/Sqm., e) Thickness- 3mmf) Make- Texsa India Ltd./IWL India Ltd./STP Ltd.g) Softening point- More than 120 C,h) Should not break at -15 C, i) Should not drip at 100 Cj) Applying a coat bituminous base aluminium paint over water proofing membrane.k) The firm will ensure that no seepage occurs from the area on which water proofing has been done as per specification above.l) The firm will provide a guarantee for 7 years from the date of completion. |
| 14 | Repairing of existing aluminium window shutters, including rubber beading and fittings. Not more than 2.5 Sqm |
| 15 | S/F 15 mm Toughened glass doors, railings, partitions automatic doors and similar work including cutting to shape, drilling holes required. , heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge |
| 16 | Taking down carefully copper /aluminium point wiring (light,socket or power) complete, including fixture and fitting such as switches,ceiling rose,pendants ,regulators,socket,light ,fitting etc removing materials to store/em for keeping in safe custody for taking credit(credit of above items should be made as per conditions sepeatly) and making good disturbed surfaces of walls,floors etc. |
| 17 | (M&L)One light point or one fan point controlled by one switch with cable 1.5 sq mm size wiring with copper conductor cables FRLS pvc single core sheathed cable in PVC conduit. Wiring will be cancelled. |
| 18 | (M&L)One 3 pin socket outlet. 15 amps,independent,with cables 4 sq.mm size Wiring with copper conductor cables FRLS pvc single core sheathed cable in PVC In stove enamelled In PVC conduit |
| 19 | (M&L) Modular switch 1 way 6A, 1 module. Make : Indo Assian, L&T,Havells,Legrand |
| 20 | (M&L) Modular switch 1 way 16A, 1 module.Make : Indo Assian, L&T,Havells,Legrand |
| 21 | (S&F) Modular Socket 6A/16A - 2/3 pin combined, 2 module.Make : Indo Assian, L&T,Havells,Legrand |
| 22 | (M&L) Modular white cover plate with frame 3 Moduel (for 5/6+15/16 power point).Make : Indo Assian, L&T,Havells,Legrand |
| 23 | (M&L) Modular white cover plate wuth frame 6 Moduel (for lighting switch).Make : Indo Assian, L&T,Havells,Legrand |
| 24 | S&F Modular metal Flush box 3 module.Make : Indo Assian, L&T,Havells,Legrand. |
| 25 | Suppy & Fixing of 5 star ,28-35 watt ,400mm BLDC Wall mounted Fan with with remote & 3 blade. Make: Havells,Crompton,Orient, Atomberg,Khul |
| 26 | (S&F)Modular metal Flush box 6 module.Make : Indo Assian, L&T,Havells,Legrand. |
| 27 | ( Supply & Fixing )Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps ( modular type). Make: Legrand,Standard,Havell\"s,L&T,Hager. |
| 28 | (S&F)Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x6.0 sq. mm +1x4.0 sq. mm earth wire in PVC conduit conceled wiring.(for AC power) |
| 29 | ( Supply & Fixing ) Sheet metal enclosure for DB\"s when MCB to be used,triple pole & neutral,8way ,double door type for light circuit & power socket. Make:Legrands,Siemens,Havell\"s,Standard,Hager, L&T,Indo Assian.( fixing of MCB DB will be concealed on wall or as directed by SIS/EIC.(for Light,power scoket,AC) |
| 30 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SP 5 To 32 AMP Make: Legrands,Schnieder Electric,Standard,Hager,Indo Assian. |
| 31 | (Supply & Fixing)Isolator Four pole 100 amp for each MCB TPN DBs. Make : Indo Assian, Legrand,Hager,L&T,Standard. |
| 32 | (M&L) ceiling rose ,3 phase/PVC/Polycarbonate ,isolated body. Make: Indo Assian,Anchor,L&T,Cona. |
| 33 | (S&F)Wiring for circuit/submain wiring alongwith earth wire with the 2x2.5 sqmm+1x2.5 sqmm earth wireof FR PVC insulated copper conductor ,single core cable in surface/recesse as required inPVC conduit.concelled wiring.(for light point) |
| 34 | (S&F) Wiring for circuit/submain wiring alongwith earth wire with the 2x4 sqmm+1x2.5 sqmm earth wireof FR PVC insulated copper conductor ,single core cable in surface/recesse as required in PVC conduit. Concelled wiring.(for power point) |
| 35 | Cuting holes in brick walls built in cement mortar .exe one brick but not exe two brick. |
| 36 | (M&L) XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core for feeding supply to all MCB TPNDBs.Make: Finolex,KEI,Gloster,Polycab. |
| 37 | Cutting chases for PVC conduits wiring/cables and sinking\"s for boxes and making goog to wall ,floors etc in case of recessed or concealed conduit wiring of light & power circuit. |
| 38 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete..MAKE:PHILIPS / CROMPTON /HAVELLS / BAJAJ / SYSKA / WIPRO. |
| 39 | [M&L] Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chase or buried in groun or drawn in conduit/pipe or fixed to pole or nay other indicated sitiation for loof earthing etc as required4mm dia galvanised iron or steel wire. |
| 40 | Supply & installation,commissioiing, testing of LT panel indoor type floor mounted , water proof ,double door with lock and key arrangment& body earth arrangement consisitng of 14 SWG MS sheet, duly pianted with grey colour & consisitng with following acessories with wirirng / connection:- (i) suitable rating TPN aluminium bus bar having good conductivity , (ii) Digital ampermeter Qty=01 no with suitable CTs(1 set),(ii) KVAH,KWH,P.F,KVA indicated digital meter, =01 No,(iii) Frquency meter =01 no(iv) Digital Voltmeter ,Qty=1 Nos . (v) Three pahse R Y B indicating lamps =1 set (vi) 01 No .For main control.(i) 1 nos ,400 amps four pole MCCB ,415 volts,breaking capapcity 50kA,make :L&T,Hager,Indo assian,Legrand,Siemens,Schnieder Electric. For outgoing circuit(ii) 04 Nos 150/160 amp MCCB 4 pole for outgoing to TPN DBs make :L&T,Hager,Indo assian,Legrand,Siemens,Schnieder Electric (iii) 03 Nos 125 Amp 4 pole MCCB . make : L&T, Hager, Indo assian, Legrand, Siemens,Schnieder Electricfor outgoing to ist floor LT Panel. (iv) provision of incoming cable &outgoing cable entry and connection through suitable lug & glands. this LT panel will be installed in first floor or as per direction of SIE/EIC. |
| 41 | Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete |