| 1 | Dismantling existing plaster including disposal of refuse as directed by Engineer-In-Charge within a distance of 60 meters. (PWD SOR 2022-23 Chapter No- 17 Item No. 16). |
| 2 | Scrapping old white or colour wash including disposal of refuse as directed by Engineer-In-charge within a distance of 60 meters (200 feet) |
| 3 | 12mm Cement plaster with cement mortar in proportion of 1:3 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth.. (PWD SOR 2025-26, Chepter-7, Item No.1 Spec. No. 13.9) |
| 4 | Finishing Wall with Putty approved brand and manufacture and of required shade on undacoreted All complete. (PWD SOR 2025-26 Chapter No-08 Item No. 31 Spec. New). |
| 5 | Finishing walls with acrylic emulsion paint of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat. (PWD SOR 2025-26 Chapter No-08 Item No. 35 New). |
| 6 | 6 Finishing Walls With Exterior Emultion Paint (Apex) of approved brand and manufacture and requred shade on undercoated wall surface to give even shade over @ 1.25 Ltr/10sqm coat suring and cost of material, labour, T&P e.t.c. requred for proper completion of work for two coat. (PWD SOR 2025-26 Chapter No-08 Item No. 35 New). |
| 7 | Painting 1st coat over Priming coat (But Excluding cost of priming coat) on steel and other metal surface All complete. Same as in item 2 above but new wood surface. (PWD SOR 2025-26 Chapter No-08 Item No.02, Spec. New. 19.29+2(a) 19.73) |
| 8 | Excavation in foundation in ordinary soil or silt (loam, clay or sand) including lift upto 1.50m and lead up to 30m and including filling watering and ramming of excavated earth in to the trenches or in to the space between the building and the side of foundation trenches or in to the plinth and removal and disposal of surplus earth as directed by the Engineer in charge up to a distance of 30m from the foundation trenches. (PWD SOR 2025-26, Chepter-4, Item No.01 Spec-251) |
| 9 | Proving and laying cement concrete in 1:4:8 Providing and laying cement concrete in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form work in Foundation and floors. (PWD SOR 2025-26 Chapter No-05 Item No. 3 spec. No. 4.1) |
| 10 | Providing and laying \"brick coba\" 12mm thicklaid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreding cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cmX30cm and side wall parapet shall be mono tythic plaster wall upto 30cm higher and junction and comer shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including supply of all material, labour, T&P etc complete for proper completion of work. (PWD SOR 2025-26 Chapter No-11 Item No. 7) |
| 11 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1) cement: 3 fine sand) as per standard design : In 75x75 mm deep chase. (PWD SOR 2025 26 Chapter No-11 Item No. 19 spec. No. 12.21) |
| 12 | M.S or Iron work of small size and section such as holding down ..All Complete. Bolts |
| 13 | Mild Steel Work in heavy Size All complete. |
| 14 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (.63 mm thick with zinc coating not less than 275 gm/m²) (PWD SOR 2022-23 Chapter No-spec. No. 12.1 Please Enable Macros to View BoQ information |