| 1 | Excavation in foundation in ordinary Soil (Loam, Cley or sand) including, lift up to 1.50 M and lead up to 30 M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge up to a distance of 30 M form the foundation trenches. (SI No. 251) |
| 2 | Providing and laying cement concrete in 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form work in foundation and floors. |
| 3 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation and plinth including supply of all material, labor T&P etc. required for proper completion of work. (S.No. 6.1.1) |
| 4 | 12mm thick cement plaster in single coat of fair side of single of half brick wall for interior plastering up to floor two level including internal rounded angles chamfers and rounded angles not excluding 80mm in girth and finished even and smooth. No extra for mixing any additive. (c) 1 cement : 4 Coarse sand. (Chapter No. 13 S.I. No.-582(ii)) |
| 5 | Providing and laying cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete, including cost of form work in foundation and floors. |
| 6 | Renforced cement concrete work in walls (any thickness), including attachedplasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struls etc. including cost of centering, shuttering, and excluding Reinforceement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Mild Steel or iron in plain work such as reinforced concrete or reinforced brick work (When not included in and an overall rates) brought to required shape as necessary including bending for proper completion of the work and including supply of steel, its wastage bend hooks and authorized over lapping shall be measured up to floor two level. (10 mm to 12mm tor (TMT Bars). |
| 8 | Mild Steel or iron in Heavy Size such as reinforced concrete or reinforced brick work (When not included in and an overall rates) brought to required shape as necessary including bending for proper completion of the work and including supply of steel, its wastage bend hooks and authorized over lapping shall be measured up to floor two level. (10 mm to 12mm tor (TMT Bars). |
| 9 | Providlng and laying Polished Granite Black stone flooring in req0ired design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admi)ied with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge(Ch-14 SI No- 22) |
| 10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. supply of all labour material and T&P required for proper completion of work(Ch-15 SI No- 22) |
| 11 | Finishing walls with exterior emulsion paint (Apex) of approved brand and manufactured and of required shade and undecorated wall surface to give even shade over @ 1.25 Ltr/10sqm including one coat of primer applied @ 0.75Ltr./10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work for two coat. |
| 12 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 13 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, lS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without filt ngs and the base support for tank (Sintex or Equivalent) For 500 litres. |
| 14 | Installation of 1.50 H.P. ISI marked sumbercible pump etc…… all complete. (As per Attache Annalysis) |
| 15 | Supply and fixing of light fitting switch board. |
| 16 | Supply and fixing of light point. (NS) |
| 17 | S/L/J of 20mm dia PVC conduct pipe etc. all complete. |
| 18 | Supply and fixing of wiring Sub Main. |
| 19 | Supply and fixing of plug power point 15mm. |
| 20 | Lettering & painting of wall etc. all complete. |
| 21 | Supply and fixing of 27 watt. CFL etc. all complete. |
| 22 | Supply and fixing exacts fan etc. all complete. |
| 23 | Supply and fixing celling fan etc. all complete. |
| 24 | Supply & Fixing Granite Board 2.5\"x4\" Size Display Board including Painting, Lettering etc. all complete. (None Schedule) |
| 25 | Sub Total (A) |
| 26 | Add/Deduction Rs. For Estimate Figure Amount Match |
| 27 | Grand Total Please Enable Macros to View BoQ information |