| 1 | Supply of 3.5C x 150 Sq.mm size 1.1 KV grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. |
| 2 | Supply of 3.5C x 185 Sq.mm size 1.1 KV grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. |
| 3 | Supply of 4C x 10 Sqmm, 1.1 KV grade, Armoured, XLPE insulated, PVC sheated,Aluminium conductor cable confirming to IS: 7098 (Part -1) 1988 amended upto date. |
| 4 | Supply of 4C x 25 Sqmm, 1.1 KV grade, Armoured, XLPE insulated, PVC sheated, FRLS at outer sheath Aluminium conductor cable confirming to IS: 7098 (Part -1) 1988 amended upto date. |
| 5 | Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor/surface mounted, double door, outdoor LT feeder panel PTTA type made out of 2 mm thick CRCA sheet duly rust inhibited, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand of size 50X50X5, depth of leg 3 feet (minimum), CC all around of the panel upto 1 Meter, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 200A 4P MCCB(Ics=Icu=50 KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction VAF Meter, suitable for measure Volatge, Current, frequency withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band \"ON\".BUS COUPLER1 Nos. 200A 4P MCCB(Ics=Icu=25 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication \"ON\", and \"OFF\".BUS BAR1 Set of 250A TPN Busbars of aluminium alloy.OUTGOING01 Nos. 125 A TPN MCCB (Ics=Icu=30 KA) with thermal magnetic release.03 Nos. 32 A TPN MCCB (Ics=Icu=30 KA) with thermal magnetic release also with Timer and suitable contactor etc.4 Sets (1 Set for each outgoing) LED type \"ON\" Indication. |
| 6 | Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor/Surface mounted, double door, outdoor LT distribution panel PTTA type made out of 2 mm thick CRCA sheet duly rust inhibited, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand of size 50X50X5, depth of leg 3 feet (minimum), CC all around of the panel upto 1 Meter,control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 125A 4P MCCB(Ics=Icu=25 KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction VAF Meter, suitable for measure Volatge, Current,frequency withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band MCCB \"ON\".BUS COUPLER1 Nos. 125A 4P MCCB(Ics=Icu=25 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication \"ON\", and \"OFF\".BUS BAR1 Set of 150A TPN Busbars of aluminium alloy.OUTGOING03 Nos. 32 A TPN MCCB (Ics=Icu=30 KA) with thermal magnetic release also with Timer and suitable contactor etc.03 Sets (1 Set for each outgoing) LED type \"ON\". |
| 7 | Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor/surface mounted, double door, outdoor LT feeder panel PTTA type made out of 2 mm thick CRCA sheet duly rust inhibited, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand of size 50X50X5, depth of leg 3 feet (minimum), CC all around of the panel upto 1 Meter, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 250 A 4P MCCB(Ics=Icu=36KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction Meter, suitable for measure Volatge, Current, Energy, frequency, power factor etc.withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band MCCB \"ON\" lamps.BUS COUPLER1 Nos. 250 A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication \"ON\" indicaton lamp.BUS BAR1 Set of 400 A TPN Busbars of aluminium alloy.OUTGOING02 Nos. 160 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 63 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 32 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release also with Timer and suitable contactor etc.-01 No.06 Sets (1 Set for each outgoing) LED type \"ON\"Indication Lamps. |
| 8 | Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor/surface mounted, double door, outdoor LT feeder panel PTTA type made out of 2 mm thick CRCA sheet duly rust inhibited, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand of size 50X50X5, depth of leg 3 feet (minimum), CC all around of the panel upto 1 Meter,control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 200A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction Meter, suitable for measure Volatge, Current, Energy, frequency, power factor etc.withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band MCCB \"ON\", indicaton lamp .BUS COUPLER1 Nos. 200A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication \"ON\", lamp.BUS BAR1 Set of 250A TPN Busbars of aluminium alloy.OUTGOING02 Nos. 125 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 63 A TPN MCCB (Ics=Icu=25 KA) with thermal magnetic release also with Timer and suitable contactor etc.4 Sets (1 Set for each outgoing) LED type \"ON\"Indication Lamp. |
| 9 | Design, Fabrication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor/surface mounted, double door, outdoor LT distributionpanel PTTA type made out of 2 mm thick CRCA sheet duly, powder coated paint, complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand of size 50X50X5, depth of leg 3 feet (minimum), CC all around of the panel upto 1 Meter, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 200A 4P MCCB(Ics=Icu=50 KA) with terminal extension.Each Incomer shall have one set of Indication Lamps, LED type, R,Y,Band \"ON.BUS COUPLER1 Nos. 200A 4P MCCB(Ics=Icu=25 KA) with terminal extension.Bus coupler shall have indication \"ON\".BUS BAR1 Set of 250A TPN Busbars of aluminium alloy.OUTGOING01 Nos. 125 A TPN MCCB (Ics=Icu=30 KA) with thermal magnetic release.01 Set ofLED type \"ON\" Indication. |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm in the existing masonry open duct as required. |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade size of above 95 Sqmm and up to 185 Sqmm cable in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade ofUpto 35 sq. mm size in the existing RCC/ HUME/ METAL/DWC /HDPE pipe as required. |
| 13 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required. |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials forsize of 3.5 x 150 Sqmmof PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials forsize of 3.5 x 185 Sqmmof PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 16 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 C x 185 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 17 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 C x 150 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 18 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 C x 240 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 25 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 20 | Supplying and making end termination with aluminium lugs for 4C x 25 sq.mm size but without gland of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 10 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 22 | Supplying and making end termination withaluminium lugs for 4C x 10 sq.mm size but excluding gland of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 23 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 24 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 25 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 26 | Supply of110 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required. |
| 27 | Laying of HDPE pipe (PE- 80, PN-6) of size110 mm (OD) in suitable depth by trencheless horizontal directional drilling (HDD) method by deploying HDD machines with necessary arrangements complete as required as per the site requirements.(Excluding the cost of 110 mm HDPE Pipe) |
| 28 | Cutting of cement concrete (Nominal concrete 1:3:6 or richer mix) road/surfaceby mechanical means as per direction of Engineer - in -charge for laying of 50mmand 63mm dia GI/HDPE/DWC pipesincluding disposal of material within 50 metres lead etc complete as required. |
| 29 | Repairing of CC road/Surface by providing and laying in position specified grade ofcement concrete 1:2:4 including watering etc complete as required. |
| 30 | Providing, laying and fixing 50 mm dia G.I. pipe (medium class) in the existing CCsurface cutting, complete with G.I. fittingsetc. complete as required. |
| 31 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement etc. with charcoal/ coke and salt as required. |
| 32 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 33 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |