| 1 | Acousticwork |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws and all doorfittings. |
| 5 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 6 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channelsection of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 metre )roll and two coats of primer suitable for panelling as per manufacturer\"s specification as per direction of Engineer-in-Charge all complete. |
| 7 | Providing and fixing 15 mm thickfalse ceiling tilesat all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge. |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface /recessedmediumclassPVC conduit, with modular switch, modular plate, suitable GI box and earthingthepointwith 1.5sq.mm FRLSPVC insulated copper conductor single core cable etc. as required. |
| 9 | Group A |
| 10 | Group B |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole |
| 16 | Supplyingandfixingfollowingrating,doublepole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 17 | Speaker cable two pair, 2-core, 1.5 Sqmm |
| 18 | Earthing with copper earth plate 600mmX600 mm X3mm thick including accessories and providing masoanry inclosers with cover plate haing locking arrangement and watering pipe of 2.7 mtr long etc . With charcol/coke and salt as required. |
| 19 | Providing and fixing nylon six printed carpet of make approved by Engineer-in-charge including fixing to the floor with adhesive of approved make carpet conforming to following specification complete. |
| 20 | 1.Description :- 6 color mix nylon printedcarpet2.Structre:- Tufted cut pile3.composition 100% nylon and fire retardant4.Gauge:-1/85.No. of knots per sqm:-1,40,000.006.Secondary backing:- Action back latex.7. width:-4 metre8. Role langth:-25 metre9. Pile height:-10mm (+ -)5%10. Total thickness:-11 to 12mm11. Pile weight:-1000gm/SQM12. Total carpet weight 1900gm/Sqm (+ -)5%13.Use: commercial14. Fire classification: - FF-27015. Thermal Resistance:- PASS16. Light fastness :- <317. Sound insulation:- 25DB.18.Coloretion:- Chrome jet printingincluding cartage, fixing etc as per direction ofEngineer-in-charge |
| 21 | Providing and fixing under layer PU(Poly urethane) sheet 8mm thick and density of 18-20Kg/m3 to enhance the cushioning of carpet as directed by Engineer-in-charge. |
| 22 | Model: 22” Push-back high chairs Design Features: - Floor-grouted installation - Fabric wrapped upholstery - Color customizable as per direction of engineer in charge - Self Tip-Up Cushions - Armrest-to-armrest center distance: 22” - Cushion and backrest housing: FEP – Fiber Molded – FRP - Cushion bottom and back rear panels: Heavy duty materials - Sheet metal parts: HRC sheet metal as per IS:1079:1994 - All visible metal parts: Painted finish - Polyurethane foam density: 50 ±5 kg/m³ (JIS K 6401 standard) |