| 1 | Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system, Clear water pump set, & lift at community hall sector-7 adjacent to palam village Sector 7 Ramphal Chowk Dwarka as per the inventory & terms and condition attached. |
| 2 | Maintenance and operation of IEI, Compound Light, Firefighting Pump set, Fire alarm system Clear water pump set, & lift at community hall HAF pkt.IIISector-09, Sector 6 Staff Quarter Dwarka as per the inventory & terms and condition attached. |
| 3 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 4 | Supplying andreplacement of 1200 mm sweep size ceiling fan i/c connection, testing etc complete as reqd. |
| 5 | Supplying & replacement following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, testing etc. complete as required.i/c Rebate for dismantle materiala) 250 A,36KA,FPMCCB (Ics=Icu) |
| 6 | b) 125 A,30KA,FPMCCB (Ics=Icu) |
| 7 | Supplying and Replacement of 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i/c Rebate for dismantle materiala) SPMCB |
| 8 | b) DPMCB |
| 9 | LED Batten Light (System lumen efficancy >=105<=120 lm/WattSupplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)18- 22 watt |
| 10 | Supplying and Replacement following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch |
| 11 | b) 3 pin 5/6 A socket outlet |
| 12 | c) 15/16 A switch |
| 13 | d) 6 pin 15/16 A socket outlet |
| 14 | Supplying and Replacement two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 x 1.5 sq. mm |
| 16 | b) 2 x 4 sq. mm |
| 17 | Servicing of 62.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. (Servicing of D.G. set has to be got done through authorised dealer of OEM)i) Oil filter --- 1 No.ii) Diesel filter (pre-micro)--- 1 setiii) Air cleaner elements --- 1 No.iv) K-cool superplus- 50-50 premix ---- 10 ltr.v) K-oil premix --- 13ltr,vi) Labour charges for servicing, functioning and testing--- 1 jobvii) Radiator cleaning charges --- 1 job i/c removal & refixing |
| 18 | Supplying and Replacement of 300 mm sweep extra size metallic exhaust fan i/c connection, testing etc complete as reqd. |
| 19 | LED Streetlight fixture, powdercoatedpressurediecast aluminumbody(Systemlumen efficacy≥120 <135 lm/Watt) Supplying,installation,Testing&CommissioningofStreetlightLED fixturepowdercoatedpressurediecastaluminumbodywith driver asper the requirement with Driver efficiency >85%, Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade,internal surge protection of 5KVL,N,EasperIEC61000-4-5,Driver efficiency >85%,THD< 10%asperIEC61000-3-2,P. F.≥0.95,IP 66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMIEMCAsper CISPR 15 , lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electrical circuitry) ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <5, Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) 90 Watt |
| 20 | Supplying of following size of XLPE insulatedaluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd.a) 2C x 16 sq.mm |
| 21 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm |
| 22 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 63 mm dia (OD- 63 mm & ID-50 mm nominal) |
| 23 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 24 | Earthing with GI Earth Pipe 4.5 mtr long, 40 mm dia. including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 25 | Providing and fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required. |