| Sl. No. | Item Description |
| 1 | B/R PORTION : |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed. |
| 3 | Dismantling of Stone slab and tiles laid bedded and pointed in any mortar of any description or thickness in floors, apron etc complete all as specified and directed. |
| 4 | Demolition of un-reinforced cement concreteof any description and any in position not otherwise specifically provided for complete all as specified |
| 5 | Demolition of cement concrete(unreinforced)in ground floors and pavings not exceeding15 cm thickness (below or above ground level) complete all as specified. |
| 6 | Taking down plastering on brick or stone wallsincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified |
| 7 | Taking down chowkhats or frames with shutters(without taking off shutters from frames) not exceeding 1.50 sqm each complete all as specified. |
| 8 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each complete all as specified |
| 9 | Taking up or taking down steel/iron tube of 15 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 10 | All as per ser. Item No08 above but for 20mm bore |
| 11 | All as per ser. Item No08 above but for 25mm bore |
| 12 | Taking down PVC pipes / any pipe of any sizeor pattern incl all fittings, head shoes, bends swan necks etc including cleaning or re-fixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified |
| 13 | Dismantling plain or corrugated steel sheeting ofany guage, thickness including Nainital or similar pattern roofcovering complete all as specified. |
| 14 | Dismantling wrought iron or mild steel work of any description complete all as specified |
| 15 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling completeall as specified. |
| 16 | Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.complete including removal of debris to a distance exceeding1.5 km but not exceeding2 Km completeall as specified and as directed. |
| 17 | M&L for brickwork with modular fly ash bricks, straight or curved on plan exceeding6m mean radius, built in cement mortar 1:6complete all as specified |
| 18 | M&L for brick work with fly ash bricks stright or curved on plan to any radius, asin half brick thick wall built in cement mortar 1:4 complete all as specified and directed |
| 19 | M&L for rendering 15 mm thick on fair faces of brick or concrete on external surfaces in CM 1:4finished fair and even complete all as specified and directed. |
| 20 | M&L for rendering 10 mm thick on fair faces of brick or concrete on internalsurfaces in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for rendering10mm thick in cement mortar 1:3 on ceilingsurface ,finished even and smooth without using extra cementcomplete all as specified and directed. |
| 22 | M&L for preparation of new plastered or unplastered surfaces of wallsand applying two coat of exterior grade paint weather resistant over a coat of primer includingcleaning the floor/ joinery, surfaces glass pansafter painting complete all as specified and directed. |
| 23 | M&L for preparation of new plastered or unplastered surfaces of walls and applying applying two coats of oil emulsion distemper over a coat of alkali resistant primer including wall care puttycomplete all as specified and directed. |
| 24 | M&L for preparation of new plastered or unplastered surfaces and applying two coats ofoil bound distemper over a coat of primeron ceiling complete all as specified and directed. |
| 25 | M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall includingpreparation of surfaceof wallsand applying two coat of exterior grade paint weather resistant over a coat of primer including cleaning the floor/ joinery, surfaces glass pans after painting complete all as specified |
| 26 | M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall and preparation of plastered surface of walls and applying applying two coats of oil emulsion distemper over a coat of alkali resistant primer including wall care puttyfor smooth surface complete all as specified and as directed. |
| 27 | M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall and preparation of plastered surface of walls and applying two coats of oil bound distemper over primer on ceilingfor smooth surface complete all as specified and as directed. |
| 28 | M&L for non-skid ceramic coloured tiles7 to 8mmthick (square / rectangular) area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmin floors etc, set and jointed in neat cement slurry and pointed incoloured cement to match with colour of tile , grade B1 quality over and including 15mm thick cement screed 1:4 and applied with cement slurry at the rate of 3 kg per sqm complete all as specified |
| 29 | M&L for vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqmin floors etc, set and jointed in neat cement slurry and pointed incoloured cement to match with colour of tileoverand including 15mm thick cement screed 1:4 and applied with cement slurry at the rate of 3 kg per sqm complete all as specified |
| 30 | M&L for vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed incoloured cement to match with colour of tile including a backing coat 10mm thick in cement mortar 1:4 complete all as specified |
| 31 | M&L for non ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurryincluding 15mm thick bedding layer in cement mortar 1:6including necessary cutting and waste as per site requirement pointed incoloured cement to match with colour of tile complete all as specified and directed. |
| 32 | M&L for 25mm thickPCC 1:2:4 type B0 using 12.50 mm graded stone aggregate as in levelling coursecomplete all as specified |
| 33 | M&L for glazed ceramic tiles coloured of size 350mm x 250mm/ 450mm x 350mm / 300 x 450mmx7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed incoloured cement to match with colour of tile including a backing coat 10mm thick incement mortar 1:4.complete all as specified and as directed. |
| 34 | M&L for coloured glazedtiles of size 300x200x7mm thick, on walls / vertical surfaces such as dado,skirting etc set andjointed in neat cement slurry andpointed incoloured cement to match with colour of tileover and including 10mm thick backing coatin CM 1:4 complete all as specified |
| 35 | M&L for 60 mm thick machine pressed precastconcrete interlocking paver block factory manufactured (ISI Marked) any shape and size conforming to IS 15658-2006 of M-35 Grade,casted with grey cement and top layer with grey cement & without pigment floor,pavement,etc over and including 50 mm thick sand cushioning all as specified and directed. |
| 36 | M&L for coloured chequered cement concrete tiles machine pressed of size 25cmx 25cmx 22mm thick with grey cement and no pigment , setjointedin neat cement slurry and pointed incoloured cement to match with colour of tile over and including 15mm thick screed bed in cement mortar 1:4complete all as specified. |
| 37 | M&Lfor 18mm to 20mm thick Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 38 | M&L for outdoor colouredvitrified paving tiles, joint free (edge cut) of size 300 mm x 300 mm x 8 to 10 mm thick as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the colour oftiles complete all as specified. |
| 39 | M&L forplain cement concrete1:3:6 type C2 using 40mm graded stone aggregate,75mm thickas in plinth protection , finished thesurfaces fair and even completeall as specified. |
| 40 | M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight,at the junction of plinth protection surfaces complete all as specified. |
| 41 | M&L for plaincement concrete1:4:8 type D2 using 40 mm graded stone aggregate ,100mm thickas in sub base complete all as specified. |
| 42 | M&L for plain cement concrete 1:2:4 type B2using 40 mm graded aggregate ,100 mm thick asin flooring and finished thesurface even and smooth without using extra cementcomplete all as specified and directed |
| 43 | M&L for cutting openings, through brick walls for door, window and other openings or enlarging existing openings , converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish off to a distance not exceeding50m complete all as specified and directed |
| 44 | Supply ,fabricate and fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt of 200 mm size etc including taking down or and making good of disturbed surface complete all as specified here-in-before(a) Frame(top & side)section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm(Section No 19584)(f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370). |
| 45 | S&F Aluminium die cast body door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete. |
| 46 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position. |
| 47 | Supply, fabricate andfix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) partition wall, partly glazed with 5.50 mm thick tinted glass and partly panlled with 9 mm thick prelaminated particle board with both side decorative laminatied including rubber bead joining cleat for fixing in position etc complete all as specified belowand directed. (a) Outer member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20102) (b) Middle member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20057) (f) Glazing clip for securing glass / panel shall be be of 0.80 mm thick (Section No 19370). |
| 48 | Supply, fabricate and fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) two track window ( two shutters glazed) with frame, glazed with 4 mm thick tinted glass ,including rubber bead joining cleat for fixing in position, concealed type lock for all two shutter, PVC roller etccomplete all as specified below and directed.(a) Frame (top & side) section shall of size 61.85 x 31.75 x 1.50 mm ( Section No 20829) (b) Frame (bottom) section shall of size 61.85 x 31.75 x 1.50 mm ( Section No 20830) (c) Top & side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20738)(d) Shutter Interlock Section shall beof size 18.00 x 40.00 x 1.45 mm (Section No 20737) (e) Bottom Members of shutter Section shall beof size 18.00 x 40.00 x 1.55 mm (Section No 20736) |
| 49 | Supply, fabricate and fixing in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) ventilator, partially glazed and partially louvers, outer frame & mullionfabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including S.S wire gauge of fixing of 0.36mm dia and 1.40 width of aperture with 25x3mm think aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position all as specified and directed. Note for Serial Item Nos 46 to 48:- (a) Section No given above shall be of Make-Jindal andfor guide line. (b) The measurements shall be taken actual sizeat site,wastages if any shall be included in the rates quoted. (c) The above sections shall be from any of makes of JINDAL/ INDAL/ HINDAL/ WALCO. (d) MAKE OF GLASS:ATUL/ MODI GUARD/ SAINT GOBAIN. |
| 50 | S&F mild steel framed work such as grills ,gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,framework of water tanks and similar work conforming to Fe 290 GradeE-165 complete all as specified |
| 51 | M&L for forming jambs to openings including cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work complete in cement mortar 1:4 |
| 52 | M&L for making good under cills or over arches lintels and bressummers including all pinning when necessary complete in cement mortar 1:4 |
| 53 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm thick MS square tube of 19 gauge mitre cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS squaretube inside the 19mm MS square tube and suitably screwed complete all as specified and as directed. |
| 54 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail & bottom rail Paneling plain colour PVC sheet to be fitted in MS frame welded/sealed to the stile & rails with suitable PVC sheet beading as per specification & shown on drawing in SSRPart t II of 2020 complete all as specified. |
| 55 | S&F 75mm size type C21 Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised complete . |
| 56 | S&F aluminium handle of size 150 mm cast type anodized |
| 57 | S & F aluminium anodized tower bolt of size 150mm |
| 58 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly prepared steel surfaces over 10cm in width or girth not otherwise described. |
| 59 | S&F roller blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per Manufacture instruction complete as per sample kept in GE’s office . Make: Ista or other equivalent make approved by the GE |
| 60 | S&F Mineral Fiber Acoustical Suspended Ceiling System with Beveled Regular Edge Tiles laid over & including 15 mm Exposed grid system detail as under :- (a) The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 30%.(b) The tile shall be laid on 38 mm x 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38 mm and a load carrying capacity of 14 Kgs / Sqm & pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per Sqm. (c) Grid system shall comprise main runner spaced at 1200mm centre to center securely fixed to the structural soffit using suspension system as specifications below at 1200 mm maximum centre.The First / Last suspension system at the end of each main runner should not be greater than 450 mm from the adjacent wall. Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm centre to form 1200 x 600 mm module.Cut cross tees longer than 600 mm require independent support.600 x 600 mm module to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to wall angles of size 3000 x 19 x 19 mm, secured to walls at 450 mm maximum centre to centre. (d) Suspension system shall consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2 mm, A pre Straightened Hanger wire of dia2.5 mm of 1.8 m length., and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8 mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. Make:- Armstrong ( Tile shall be model name Classic Lite & Grid system Shall be Model Name Suprafine XL 15 Exposed) or USG / AMF or equivalent of make approved by GE |
| 61 | Supplying, fabricating and fixing cladding on RCC column , steel gate (for all height, outer surface) of aluminium composite panel in metallic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick, mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based fluoropolymer resin coating of approved colourand shade on exposed face and polymer (Service) coating on other face, fixed over and including base frame fabricated with aluminium square pipe of size 25 mm x 20 mm with 1 mm wall thickness in 600 mm x 600 mm size grid including stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant for groove filling, backer rods etc. complete all per Manufacturer instruction and as directed. |
| 62 | S&F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified. |
| 63 | S& F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixingon to wall to make PVC Frame complete all as specified. |
| 64 | M&L for Complete removal of existing water proofing treatment over roof including PCC of any thickness description in any position including cleaning the surfaces with wire brushing, watering and removing debris up to 1500 m distance etc complete all as specified and directed. |
| 65 | M&L for PCC 1:2:4 type B0 (using 12.50 mm stone aggregate) as in levelling course mixed withintegral water proofing compound all as per Manufacturers instructionsas in roofs complete all as specified and directed. Note:- WPC shall be measured & paid seperately. |
| 66 | M&L for rendering 10mm thick in cement mortar on concrete surfaces of roof finished even and smooth without using extra cement to recive water proofing membarane mixed with integral water proofing compound as per Manufactures all as specified and directed. Note:- WPC shall be measured & paid seperately. |
| 67 | Supply only integral water proofing liquid |
| 68 | M&L for prepartion of the plastered surfaces by thoroughly removing all loose particles, dirt/ dust particles and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg/Sqm confirming to IS 702 over a coat of water based bituminous primer @ 0.40 litre / sqm and laying APP based polymeric membrane as per IS 16540-2017/ IS 16532-2017with overlap of 100mm minimum weighing 3.6 kg/ sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/ sqm) by forced applicationand finally finsihed the memberance surface by applying a coat of solar refelective aluminium paint @ 0.1 litre / Sqm complete all as per Manufacturer\"s instructions as specified and as directed. |
| 69 | S&F Unplasticised PVC pipes and fittings of 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 70 | S&F Unplasticised PVC pipes and fittings of 20mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 71 | S&F Unplasticised PVC pipes and fittings of 25mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 72 | M&L for Cutting chases or making holes in brick walls for concealed watertubing, making good to facings where required, cutting not exc 10 cm girth complete all as specified and directed |
| 73 | S&F in repairs vitreous china water closet pan (pedestal pattern), white including fixing bolts, plastic water closet seat, black/white closed pattern with flat bottom and cover and mild steel chromium plated hinging device complete all as specified anddirected. |
| 74 | S&F in repairsvitreous Chinaware squatting pan, ‘Orrisa pattern’ of size 580 mm x 440 mm, snow white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B1 using 20 mm graded crushed stone aggregate complete all as specified, including making connections to trap and to flush pipe, etc and making good to floors completeall as specified. |
| 75 | S&F in repairs PVC valve less flushing cistern syphonic action type, low level, inlet, ball valve, float & handle 10 litre capacity including brackets, flush pipe and all accessories complete all as specified and directed. |
| 76 | S&F in repairs of 2-in-1 faucet with 1.5m tube and hook |
| 77 | S&F in repairs Vitreous China wash Basin (countertype) , including brackets, CP waste coupling 32mm and waste pipe,including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified and directed |
| 78 | S&F in repair vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mmexcluding supply of taps,but includingwaste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and flt nuts , flange end embedded in red lead cement and other end fixed , chain and plug and porcelain stopper and brackets including cutting for and pinning in ends of brackets or erecting stand ,making connections to waste and supply pipes andcomplete all as specified and directed |
| 79 | S & F in repair vitreous chinaurinal half stall urinal type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including60mm long brass screws pointing around urinal back in cement complete all as directed. |
| 80 | S&F in repairs 15 mm dia Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for PVC/ iron pipe or for brass ferrule and fixed complete all as specified amd directed |
| 81 | S&F in repairs 15mm dia stop valve/Angle valve, chromium plated fancy type cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for PVC/iron pipes or for unions and fixed of,complete all as specified and directed. |
| 82 | S&Fin repairs pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or cold with long screwed shanks and flynuts, scewed for union pipe and fixed to 15mm dia pipe. |
| 83 | S&F in repair 15mm dia Swan neck type chromium plated pillar taps, cast copper alloy with capstan heads screwed down high pressure, with or without lettered \"Hot\" of cold with long screed shanks and fly nuts screwed for iron pipe and fixed with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule and fixed complete all as specified and directed. (Prayag CAT No : 9914) |
| 84 | S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor, of 110 mm dia complete all as specified |
| 85 | S&F PVC (SWR)bends110mm dia of any radius with access door |
| 86 | S&F PVC (SWR) branch piece, single (Y)equal or unequal110 mm bore with access door. |
| 87 | S&F 75 mm bore PVC ( SWR) pipes ofsingle socketed in any length with rubber ring joints fixed to floor all as specified |
| 88 | S&F 75 mm bore. PVC (SWR) bends |
| 89 | S&F PVC (SWR) Gully trap 125/110mm setting and jointing with solvent cement complete all as specified |
| 90 | S&F in repairs tubular towel rail brass chromium plated, 20mm dia, complete all as specified (Make : Prayag / COMMANDER) |
| 91 | S&Fbrass CP two way bib tap of 15mm dia chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for PVC/ iron pipe or for brass ferrule and fixed complete all as specified |
| 92 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, all as specified |
| 93 | S&F PVC connections 15mm size with PTMT nuts of length 600 mm,complete all as specified |
| 94 | S&F in repair 500litres capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed |
| 95 | S&F in repair 1000litrescapacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed |
| 96 | S&F Ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed. |
| 97 | S&F in repairs600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 98 | S&F in repairs Stainless steel Soap dishfixed to wall all as specified |
| 99 | S&F for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long |
| 100 | M&L for PCC 1:3:6 type C2using 40mm graded stone aggregateas in foundation of post holes filling and mass concrete all as specified |
| 101 | S&FRolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides;fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 102 | S&F mild steelJoist, channel, angle, or tee sections, fixed independently, withoutconnecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated Fe 410 -W (Gde- E- 250) quality A complete all as specified |
| 103 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly prepared steel surfaces over 10cm in width or girth not otherwise described. |
| 104 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified |
| 105 | S&F 6 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and as per Manufacturer\"s instructions . |
| 106 | E/MPORTION : |
| 107 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 108 | M&L for point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulatedFRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly,including steelbox of required module for fixing of switches/sockets and regulators all as specified complete following:- Note : Cost of terminal box and cutting chases for concealing pipes shalldeemedto be included in the item rates quoted for point wiring. |
| 109 | One light point controlled by one switch. |
| 110 | One ceiling fan point controlled by one switch and regulator |
| 111 | One Exhaust fan point controlled by one switch. |
| 112 | One wall fan point controlled by one switch. |
| 113 | One switch socket outlet 3 pin 5 Amps on same board along with other switches |
| 114 | One switch socket outlet 3 pin 5 Amps on independent board. |
| 115 | All as per item No 106 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulatedsingle coremultistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board and industrial socket complete all as specified and as directed. |
| 116 | S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all specified. |
| 117 | S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified. |
| 118 | S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all specified. |
| 119 | S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified. |
| 120 | S&F electronic fan regulator, flush type complete all as specified |
| 121 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified. |
| 122 | S&F MCB DB SPN 12 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer andSP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incomingand Outgoing MCB measured separately relevent items. |
| 123 | S&F Load line MCB DB TP&N 4 way, vertical, doubledoor, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 125 Amps as incomer and SP MCBs 32 amps as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items. |
| 124 | S&F MCCBs125 Amps 415V,16KA, 4 Pole complete all as specified . |
| 125 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified. |
| 126 | S&F240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified. |
| 127 | S&F Surface and wall mounted LED tube light fitting, 20/22 W, batten type,PC housing provided for efficient heat dissipation with polycarbonate diffuser andintegrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220/230 Volts,50 Hz supply, and including connecting up with PVC sheathed suitable copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. |
| 128 | S&F Surface and wall mounted LED tube light fitting, 9/10 W, batten type,PC housing provided for efficient heat dissipation with polycarbonate diffuser andintegrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220/230 Volts,50 Hz supply, and including connecting up with PVC sheathed suitable copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. |
| 129 | S&F surface/recess mounting LED backlit panel ceiling light2X2 environmental friendly new generation aesthetically designed ultra modern recess/surface mounting luminaire with high brightness SMD LEDs as light source, LED backlit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 34/36 Watt LED (2\"X2\") complete with electronic driver, suitable for operation on AC, single phase , 220/230V , 50 Hz , including provision of suitable twin corecopper conductor PVC insulated , 1100 Volts grade cables not more than 5 m long and connecting up ceiling rose and fittings and testing, making good the disturbed any type of ceiling including taking down old fittingsall as specified and as directed. |
| 130 | S&F LED building security light fitting 45 W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wireincluding provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to buildingscomplete all as specified and as directed. |
| 131 | Taking down carefully Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2 runs of 6/10 Sq.mm removing materials from site, taken ascredit andmaking good thedisturbed surfaces complete all as specifiedand as directed. |
| 132 | M&L for power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmconforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly complete all as specified and as directed. |
| 133 | M&L for power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 10 sqmmconforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistrandedcopper conductorcable (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly complete all as specified and as directed. |
| 134 | Taking down unserviceable fans,sealing cable end, dismantling blades and removing fan and deposit blades to store complete all as specified and as directed. |
| 135 | S&F ceiling fan complete with accessories230 V,1400 mm sweep, BLDC type,BEE 5 star rated complete fixing arrangements all as specified and directed. |
| 136 | Taking down unserviceable Exhaust fan /Air circulator fans sealing cable end, dismantling blades and removing fan and deposit blades to store complete all as specified and as directed. |
| 137 | S&F exhaust fans AC single phase 230/ 240 V of size 300 mm sweep, 1425 RPM with louver complete all as specified and directed. |
| 138 | S&F wall mounted fans AC single phase 230/ 240 V of size 400 mm sweep with fixing arrangement complete all as specified and directed. |
| 139 | M&L for making hole for fixing of Exhaust fan of size 300 mm with and including necessary civil work, alterationin exist ventilation window of iron/aluminium frame for fixing of fan as per site requirement complete andmakinggood the wall/ventilation/ window surfaces to match with existing complete all as specified and directed. |
| 140 | M&L for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified |
| 141 | M&L for Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of SSRPart-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed. |
| 142 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed. |
| 143 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed. |
| 144 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed. |
| 145 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 146 | Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified . |
| 147 | Labour for filling thefine seived excavated dry soil laid to the required thicknessintrenchas a cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning |
| 148 | Supply and laying of common burnt clay building bricks, sub class B sizefor cable protection all as specified and as directed. |
| 149 | M&L for GI tubing light grade 50 mm for cable protection laid in trenches complete all as specified and as directed. |
| 150 | Supply.install,testing and commissioning of cubical Outdoor type LT Electrical distribution feeder pillar box CPRI approved platform mounted factory made totally enclosed dust and vermin proof double shutter front opening with locking arrangement complete made ofapproximatesize 1200 mm x 1000mm x 450 mm thick frame work and 3.15 mm thick CRCA sheet duly painted over outside and inside with detachable sheets with holes for cable glands,separate bus bars,cable entry and exits, panel base of angle iron 50x50x6 mm upto 60 cm height mounted on ground /PCC pillars with bolts grounted complete .The panel comprising of Aluminium bus bars of 500 A capacity,415 volt 50Hz,3 phase 4 wire system with insulators and internal wiring complete accessories with following requirements :- |
| 151 | INCOMING:- |
| 152 | (a)MCCB adjustable thermal magnetic release type of capacity 320 amps, 4 pole,36 kA.- 1 Nos.(b) On load change over siwtch 320 Amps ,4 pole 415 volts ,3 phase ,50 Hz AC - 01 No |
| 153 | OUTGOING |
| 154 | (a) MCCB adjustable thermal magnetic release type of capacity 125amps, 4 pole,16 kA.- 02 Nos. |
| 155 | (b) MCCB adjustable thermal magnetic release type of capacity 100 amps, 4 pole,16 kA.- 02 Nos. |
| 156 | (c) Indicating Lamp LED Type- 01 set (03 Nos) |
| 157 | (d) Multifunction meter digital type -01 No |
| 158 | M&L for earthing complete with galvanised steel earth plate electrode of size60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metredeep below normal ground level with top edge of the plate not lessthan1.5 metre below normal groundlevel surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised iron strip 32x6 mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009)all as specified and directed by Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail