| 1 | Dismantling of brick tiles single layer jointed & pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered by Engineer-in-Charge in writingcomplete all as specified and directed. and directed. |
| 2 | Demolition of mud phuska in roofs, any thickness, including leeping plaster (whether full thickness removed or only a part thereof)complete all as specified and directed. and directed. |
| 3 | M&L 40mm thick average consolidated thickness, mud phuska on flat roofsincluding 25mm thick mud plaster and 3 mm thick leeping plastercomplete all as specified and directed. and directed. |
| 4 | M&L 40 mm thick brick tiles laid on mud mortar and joints grouted flus in cement mortar 1:3 mixed with 5% of crude oil by wt of cement on mud phuskacomplete all as specified and directed. and directed. |
| 5 | All as per Srl item No 4 here-in-above but except tilescomplete all as specified and directed. and as directed.Note :- Old retrieved serviceable tiles shall be reused after proper cleaning. The cost of cleaning shall be deemed to be included in the quoted rate. |
| 6 | M&L 15mm thick rendering of mortar in cementmortar 1:4 with water proofing compound as per manufacturer instructions will be on surface to be finished even and smooth (without using extra lime or cement) for laying of water proofing membranecomplete all as specified and directed. and directed. Note: WPC shall be measured and paid for separately. |
| 7 | Supply only liquid water proofing compound (WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction)complete all as specified and directed. and directed. |
| 8 | M&L for water proofing treatment to roof surface includingparapet wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfacescomplete all as specified and directed. and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced applicationcomplete all as specified and directed.. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise ofpolymeric membranes respectively and sealed all overlaps and joints as manufacturer\"s instructions. |
| 9 | M&L two coats of solar reflective bituminous aluminium Paint @ 0.1 kg per sqm over APP membranecomplete all as specified and directed. and directed. |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premisescomplete all as specified and directed. and directed. |
| 11 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour over a screed layer of 15 mm thick in CM 1:6complete all as specified and directed. and as directed. |
| 12 | M&L450mmX 300mm & 7mm thick glazed coloured(Digital colour) ceramic tiles on vertical surface of such as skirting, dados and risers to stepsetc.,including 10mm thick rendering in cementmortar 1:4 on brick or concrete surface finished rough to received dado/ skirting, set and jointed in neat cement slurry and pointed in white/coloured cement to match the shadewith cement mortar bedding and removing off the premisescomplete all as specified and directed. and directed. |
| 13 | Taking down chowkatwith shutter not exceeding 1.50 sqm (without taking off shutters) eachcomplete all as specified and directed. and directed. |
| 14 | Taking down chowkhat with shutter exceeding 1.50 Sqm and not exceeding 4 Sqm( without taking off shutter) eachcomplete all as specified and directed. and directed. |
| 15 | Taking down shutters only of any description exceeding 1 sqm and not exceeding 2 sqm eachcomplete all as specified and directed. |
| 16 | S&FFactory made box type steel window side hung with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primercomplete all as specified and directed. |
| 17 | S&F Factory made box type steel window side hung with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primercomplete all as specified and directed. |
| 18 | S&F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tubecomplete all as specified and directed. in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010) complete all as specified and directed. |
| 19 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.Make: Rajshri or equivalent in approved makes. |
| 20 | M&L Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed. |
| 21 | M&L Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with double rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed. |
| 22 | M&L Cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as in filling of steel chowkhats,bed blocks, coping etcincluding necessary form workcomplete all as specified and directed.. |
| 23 | S&F 40mm thick flush door shutter of solid core construction with particle board core both faces are covered with decorative face veneer with lipping /frame to match complete all as specified and directed. |
| 24 | S&F 35mm thick second class hard wood glazed and skelton shutters,open rebated and prepared to receive glass gauze,etc (without sash bars),edges of framingplain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) fitted to chowkat complete all as specified and directed. |
| 25 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staple etc complete all as specified and directed. |
| 26 | S&FAluminium alloy, anodised, sliding door bolt 300mm length,with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 27 | S&F 150mm long aluminium, anodisedbarrel tower bolts of extruded section, complete all as specified and directed. |
| 28 | S&F 150mm Extruded aluminium alloy handlecomplete all as specified and directed. |
| 29 | S&Fbutt hinges, 100mm long of mild steel, medium weight, cold rolled fixed with steel screws or welded to steel frame where required complete all as specified and directed. |
| 30 | S&F150 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and directed. |
| 31 | S&F brass CP 20mm dia tabular towel rail, 600mm long between flangesas fixed in repairs andall as specified and directed. |
| 32 | S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 33 | S&F in repair central hole basin mixer for wash hand basin/sink including all fittings ie including connection pipe as per manufaturers specification complete all as specified and directed. and directed. |
| 34 | S&F in repair for 15 mm bore fancy type wall mixer with 115 mm long bend pipe for connection to pipe with aerator complete all as per manufacturer\"s instruction and as directed. |
| 35 | S&F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 36 | S&F in repair stop valves, fancy type, CP with long shank and cup (concealed type) screwed both ends for 15mm bore of iron pipe or for union and fixed complete all as specified and directed. |
| 37 | S&Freplacement ofpressure JETfor EWC including PVC connection and CP fitting as fixed in repairs and all as specified and directed. |
| 38 | S&F in repairs looking mirror 600mmx450mm with aluminium channel frame, selected quality mounted on 6mm thick commercial ply wood back and fixed with chromium plated brass screws and cup washerscomplete all as specified and directed. |
| 39 | S&Fin repair chromium plated shower rose with or without swivel joints any size including fixing to steel pipe or union complete all as specified and directed. |
| 40 | S&F in repair PVC Connection, Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 600 mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair complete all as specified and directed. |
| 41 | S&F Vitreous china wash down water closet pan ( pedestal pattern) white ( Excluding fixing bolts , flushing cistern and flush pipe as fixed in repairs complete all as specified and directed. |
| 42 | S&F Vitreous china squatting pan ,Orissa pattern size 580mmX440mm white, with integral foot rests including necessary lime concrete and 110mm bore PVC (SWR) \"P\" trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints fixed in repair complete all as specified and directed. |
| 43 | S&F in repairs Seat Cover (White colour) for pedestal pattern as fixed complete all as specified and directed. |
| 44 | S&F 10 litres capacity of Low level PVC flush Cistern as fixed in repairs and including of 32mmdia PVC flush pipe to connectfrom flush cistern to water closet ( any pattern) and making good all theJoints complete all as specified and directed. |
| 45 | S&F in repairs, Vitreous china wash hand basin, white flat back size 550x400mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc complete all as specified and directed. |
| 46 | S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 47 | S&F PVC waste pipe of standard pattern, not less than 75cm long , 32/40mm dia for steel sink waste coupling or urinalof suitable size complete all as specified and directed. |
| 48 | S&F in repairs stainless steel soap dish (not less than 1mm thick) of type as directed,fixed to walls with chromium plated brass screws with wooden/rawl plugs,in repair complete all as specified and directed. |
| 49 | S&F in repairs toilet paper holder of brass, chromium plated or stainless steel fixed in repair to walls with chromium plated (CP) brass screwscomplete all as specified and directed. |
| 50 | S&F in repairs glass shelves corner assemblyconsisting of 5.5mm thick sheet glass shelfwith chromium plated bracket guard and railing complete all as directed. |
| 51 | S&F in repairs PTMT grating doom 100mm dia with or without waste hole fixed complete all as specified and directed. |
| 52 | Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation,complete all as specified and directed. |
| 53 | All as per Srl Item No 52 here-in-before but 20 mm bore tubing. |
| 54 | M&L GI steel water tubing,15mm bore medium grade galvanized with all fittings and fixedto walls and celling or laid in floor, complete all as specified and directed. |
| 55 | All as per Srl Item No 54here-in-before but 20 mm bore tubing. |
| 56 | S&F in repair CPVC, medium grade, with all fitting and fixed to walls, ceilings or laid in floors 20 mm dia including taking up or down old tubing complete all as specified and directed.Makes : Finolex/Shakti/Jindal |
| 57 | S&F in repair CPVC, medium grade, with all fitting and fixed to walls, ceilings or laid in floors 15 mm dia including taking up or down old tubing complete all as specified and directed. Makes : Finolex/Shakti/Jindal |
| 58 | S&F 20mm unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe fixed as in repaircomplete all as specified and directed. |
| 59 | S&F 15mm unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe fixed as in repaircomplete all as specified and directed. |
| 60 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 61 | S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches complete all as specified and directed.. |
| 62 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches complete all as specified and directed.. |
| 63 | S&F in repairs Stack clamps for 110 mm dia pipes , out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 64 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 65 | S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 66 | S&F 110 mm PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and directed. |
| 67 | S&F 75mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 68 | S&F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 69 | S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement 75 mm dia outlet complete all as specified and directed. |
| 70 | S&F in repair ball valves of 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed complete all as specified and directed. Make: Prayag/ polytuf or equivalent in approved makes. |
| 71 | S&F Rotational moulded Polyethylene water storage tank of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down old PVC water tank complete allas specified and as directed. |
| 72 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 20 mm dia complete all as specified and directed. |
| 73 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 15 mm dia complete all as specified and directed. |
| 74 | Demolition of cement concrete in sunken portion or any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 75 | M&L 15mm thick cementmortar (1:4) with WPC on walls as well as on sunken floor portion finished even and smooth without using extra cementcomplete all as specified and directed. and directed.Note:- WPC shall be measured and paid for separately. |
| 76 | M&L for water proofing treatment to sunken floors of Kitchen, toilets, laboratories, bath and WC\"s etc shall be as under :- (i)Application of two components of Acrylic modified Cementitious coating(aa)Clean the RCC Surface with wire brush and chisel out and mortar sticking to Surface(ab)Apply FOSROC NITOPROOF 600 PF (min 0.8mm dft) over a priming coat of NITOPROOF WB Primer or equivalent of ASIAN PAINT/SIKA/BERGER/PIDILITE DR FIXIT |
| 77 | M&L PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate ) as in filling under sunken portion complete all as specified and directed. |
| 78 | M&L 25 mm thick PCC(1:2:4) type B0 (using 12.5 mm graded stone aggrigate) as in floor finished even and rough to receive top layercomplete all as specified and directed. |
| 79 | Demolition ofbrick work built in cement mortar of any specification and in any positioncomplete all as specified and directed.. |
| 80 | M&L Brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified and directed. |
| 81 | All as per Srl item No 80 here-in-above but except bricks complete all as specified and as directed.Note :- Old retrieved serviceable bricks shall be reused after proper cleaning. The cost of cleaning shall be deemed to be included in the quoted rate. |
| 82 | Taking downcementplasterany description on brick or stone walls, /RCC walls surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etccomplete all as specified and directed. |
| 83 | M&L rendering 15mm thickin cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cementcomplete all as specified and directed. |
| 84 | M&L Rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or conrete surfaces, surfaces finishedeven and faircomplete all as specified and directed. |
| 85 | M&L for applying Silane Siloxane based water repellent coating FOSROC NITOCOTE SN 522 (or equivalent of SIKA/Berger/Asian Paints/Pidilite/Dr Fixit) by evenly spraying or brushing (coverage approx 7 Sqm per litre of NITOCOTE SN 522) to external walls from plinth protection to bottom of window cills level complete all as specifed and directed.(i)Clean the surfaces to remove loose particulars or any efflorescence on bricks.(ii)Application of Silane Siloxane based water repellent by spraying or brushing (coverage approx 7 Sqm per litre of NITOCOTE SN 522) |
| 86 | M&L Rendering 5mm thick in cement mortar (1:3) oninceiling, soffits of chajja or similar location any face of brick walls or conrete surfaces, surfaces finished even and smooth without using extra cement,etccomplete all as specified and directed. |
| 87 | M&L Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of primer and applying a coat of 1mm thick wall care putty complete all as specified and directed. |
| 88 | M&L Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant priming paintcomplete all as specified and directed. |
| 89 | M&L Preparation of new plastered surfaces and applying three coatswhite washing on ceiling surfacescomplete all as specified and directed. |
| 90 | M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide zink primer on steel surfaces complete all as specified and directed. |
| 91 | M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and directed. |
| 92 | M&L Complete removal of existing treatment of wall suface and applying two coats of oil bound distemper over a coat of primer on a coat of 1mm thick wall care putty complete all as specified and directed. |
| 93 | M&L Complete Removal of existing treatment of walls applying two coats of cement based paint over one coat of cement primer on plastered surfaces all as specified and directed. |
| 94 | Excavating in trenches, not exceeding 1.5m wide & not exceeding1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified and directed. |
| 95 | M&L Cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 96 | M&Lformwork to sides of pillars, posts, struts, piers,band and foundation columns and stanchions Square, rectangular surfaces of concrete complete all as specified and directed. |
| 97 | M&L PCC 1:2:4 type B1 using 20mm graded aggregate as in lintels Cills,Steps, Plinth courses, Railings, Copings, Bed plates , kerbs etc.inlcuding weathering slightly rounded or champfered angles and throating etc.complete all as specified and directed. |
| 98 | M&L preparing new surfaces of walls and applying two coats of cement based paintcomplete all as specified and directed. |
| 99 | S&F 110 mm dia PVC (SWR) pipe single socketed, in any length as in weep holes to boundary wall laid in masonarycomplete all as specified and directed. |
| 100 | Returning, filling in, including spreading, leveling, watering and well ramming soft/loose soil in layers not exceeding 25 cm thickness complete all as specified and directed. |
| 101 | Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed. |
| 102 | M&L Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 103 | M&L preparation of old painted steel surfaces, of any description, not otherwisedescribed over 10 cm width or girth and apply two coat of synthetic enamel pain tcomplete all as specified and directed. |
| 104 | M&L preparation of new steel surfaces of any description not otherwise described , over 10 cm width or girth and applying 2 coats of synthetic enamel paint of approved shade complete all as specified and directed. |