| 1 | M&L pre cast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) including demolition of PCC as in block walling built in cement mortar complete all as specified and directed. |
| 2 | M&L for 15mm thick rendering in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and fair (without using extra cement) including Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of chalk white primer complete all as specified. |
| 3 | Demolition of cement concrete (unreinforced) in ground floor any type and any position and paving including PCC tiles any type n exc(below or above GL) all as specified. |
| 4 | M&L for 75mm thick, cement concrete,type C-2, 1:3:6 (40 mm graded stone aggregate) as in floors & pavings, plinth protection, path, etc. finishing top surface even and Smooth with using extra cement all as specified. |
| 5 | M&L for 25 mm PCC cement concrete type B1 1:2:4 (using 20mm graded aggregate) in floor as PCC padding for tiling etc complete all as specified |
| 6 | M&L Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 7 | M&L Pre painted galvalume aluminium Zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in Ridges/ Valley roof covering /cladding etc to wall fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 8 | Roof truss (framed) trussed, purlins crane gantries, rails and fastenings and heavy bracket framing (Beam tee, angle,hollow section, channel,Pipes or flat sections) inclusing distance pieces,cleats etc Fe 410-W (Gde E-250) quality B, complete all as specified and directed. |
| 9 | M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over red lead primed steel surfaces complete all as specified. |
| 10 | M & L 9 mm thickPrelaminated Partical Board interior grade prelamination one side & other side balancing white lamination fixed with nails to timber frame work as in ceiling including dismantling wall and ceilling boards of any description including cover fillets complete. |
| 11 | M & L 11 to12 mm thick Prelaminated Partical Board interior grade prelamination one side & other side balancing white lamination fixed with nails to timber frame work as in wall including dismantling wall and ceilling boards of any description including cover fillets complete. |
| 12 | S&F 2nd class HW plain fillets Square rectangular/triangular in section clean sawn secured with nails sec area exc 06 & n.exc 13 sqcm including dismantling timber fillets, rails, posts rafter purlins under 40 Sqcm in sectional area complete all as specified and directed. |
| 13 | S&F 2nd cl HW plain fillets square rectangular, triangular in section wrought with nails sectional area exc. 3 and n.exc 6 sqcm including dismantling timber fillets, rails, posts rafter purlins under 40 Sqcm in sectional area complete all as specified and directed. |
| 14 | S&F 2nd cl HW plain fillets square rectangular, triangular in section wrought with nails sectional area n\"exc. 3 Sqcm as in beadings including dismantling timber fillets, rails, posts rafter purlins under 40 Sqcm in sectional area complete all as specified and directed. |
| 15 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each complete all as specified and directed. |
| 16 | S& F second class hard wood plain, solid straight chowkats and frame, wrought framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints including making good disturbed surfaces of wall complete all as specified and directed |
| 17 | S&F 35mm thick second class hard wood plain framed panelled shutters(any number of panels ), with panels of timber flat on both sides (feather edge), or of veneered particle board medium density wood wood particle board with commericial face veneers and fitted to chowkats. |
| 18 | M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 19 | S&F 4.8 mm thick, plainsheet glass ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified. |
| 20 | S &F in repair Galvanised mild steel wire cloth0.48 mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staplescomplete all as specified as in repair. |
| 21 | S&F 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work, including dismantling of boarding, any description,, fixed in any position complete all as specified and directed |
| 22 | S&F in repair Continuous (piano) hinges, mild steel bright finish or electro galvanised with flap (when open) 40 mm, fixed with steel screws complete all as specified. |
| 23 | S&F in repair Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified. |
| 24 | Supply & Fixed600mm long Stainless steel curtain rod with fancy type brackets, side knobs/caps including with all fittings as fixed in repairs and all as specified and directed by Engineer-In-Charge. |
| 25 | S&F 150mm long aluminium, anodisedbarrel tower bolts of extruded section, all as specified and as directed by the Engr-in-charge. |
| 26 | S&F 100mm Extruded aluminium alloy handleall as specified and as directed by the Engr-in-charge. |
| 27 | S&FAluminium alloy, anodised, sliding door bolt 250mm length,with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified. |
| 28 | S&F140 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed. |
| 29 | S&F in repair Aluminium body hydraulically regulated Door closeruniversal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and directed. |
| 30 | M & L for non skid coloured ceramic tiles of7 to 8 mm thick, area of each tile exceeding 0.06 sq m but not exceeding 0.11Sq min floors set and jointed in neat cement slurry and pointed in white cementmixed with colour pigment to match over and incl a screed layer of 15 mm thick in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed. |
| 31 | M&L for wooden floor tiles of size 1200 x 200 mm and 7 mm thick with dove tailed joints laid over 3mm thick foam as per manufacturers instructions including taking down of old wooden flooring any type and fixed with decorative wooden beadings as per site requirement complete all as specified and directed by Engr-in-charge, complete. |
| 32 | S/F of Glazed coloured and cereamic tiles in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over backing coat over & incl 10mm thick rendering in cement mortar 1:4 for laying skirting dados and vertical surfaces including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises all as specified and directed |
| 33 | S&F CP Soapdish Oval /square type as fixed in repairs andall as specified and directed. |
| 34 | S &F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long |
| 35 | Taking down GI/PP-R tubing 20mm dia and connection including removable to store complete all as specified and directed. |
| 36 | Taking down GI/PP-R tubing 25mm dia and connection including removable to store complete all as specified and directed. |
| 37 | S&F 25mm outer dia, 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. all as specified |
| 38 | S&F 20mm outer dia, 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. all as specified |
| 39 | S&F in repair 15mm bore CP stop valves/ angle valve CP of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup complete all as specified. (Make: Jaguar/ Cera/Prayag/ or equivalent) |
| 40 | S&Fin repair long body CP bib tap, 15mm bore, screwed down, screwed for iron pipe or for brass ferrule complete all as specified. (Make: Jaguar/ Cera/Prayag/ or equivalent) |
| 41 | S & F in repair to CP WHB mixer (Parryware cat No: G3165A1 Basin Mixer N/ Jaguar cat No: ARI-CHR-39001B/ or equivalent) 15mm bore. With out popup waste system with 450mm long braided hoses Complete all as specified and directed by Engineer in Charge.(Make:Jaguor/Parryware or Equivalent) |
| 42 | S&F Vitreous china wash down water closet pan (pedestal pattern)white/coloured cascade type 640X360X690 (monolithic flush cistern type) Make: Parryware C849P (S-110) (640 x 355 x 695mm) White/ Jaguare Model NO:SLS WHT-6853S/CERA Cat No: s1013132s or equivalent single picece wc with PP seat cover ,Hinges fixing accessories set including flush cistern with S-Trap of size 220mm all as per manufacturing instructions and all asspecified and directed. (Make:Jaguor/Parryware or Equivalent) |
| 43 | S&Ftable top Wash hand basin vitreous china (white) wall mounted with box type wash basin vanity including CP waste fittings 32mm bore size, waste pipe PVC 32mm bore,& making good disturbed surfaces to match with the existing as in repair complete all as specified.(Make:Jaguor/Parryware/Prayag/Cera or Equivalent) |
| 44 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches including taking down eaves gutters and rain water pipes (any size or pattern),including all fittings heads shoes bends swan-necks etc complete all as specified and directed. (Make: Supreme/ Finolex or equivalent) |
| 45 | S&F 75mm dia PVC (SWR)with access door bends any radius complete all as specified and directed. |
| 46 | S&F in repairHealth Faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25mm long flexible tube and ABS wall hook including making connections and fixed in position complete in all respact as specified |
| 47 | S&F in repair CP Grating doom 125 mm dia with waste hole (Minimum weight 40gms) complete all as specified |
| 48 | E&M |
| 49 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc. |
| 50 | Material and labourfor point wiring with 1.5 sqmm cable FRLSPVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLScopper conductor as earthingand connected to common earthing with PVCheavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etcfor the following : - |
| 51 | One light point/ one fan point/ Bell Point controlled by one switch |
| 52 | One 3 pin socket outlet, 5 Amp independent |
| 53 | Supplyswitch piano flush type single pole one way5 Amps all as specified |
| 54 | Supplyswitch socket combination multi purpose, 5 amp all as specified |
| 55 | S & FCeiling rose3 plates flush type 6 Amps,250 volts ACISI marked |
| 56 | All as per item No 2 above butfor point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy dutyISI marked /heavy duty conduitISI marked as required at site alongwith accessories with 2.5 Sq mmFRLS PVC insulated unsheathed copper conductor cable as earthing and connected to common earth all as specified. |
| 57 | S & Fswitch socket combination switch socket outlet 3 pin, 16 amp flush type |
| 58 | S&F wall mounted LED light fitting 1x20 watts AC decorative box type with driver holder including LED tube light , energy efficient type 4 feet long including neccessary conection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose. |
| 59 | S&F LED security light fitting 35 watts 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 60 | Supply and fix Bed Side Light LED 3 Watt complete all as specified and directed. Make : Philips/ CG/ Havells |
| 61 | Supply and fixsheet metal enclosure SPN DB 08 way,single phase 240 volts double door with 200 amp rated bus bar complete all as directed. |
| 62 | Supply and fix for miniature Circuit breaker (MCB) single pole and current carrying caoacity 5 to 32 Amp 240 volt \"C\" curve 10 KA in the MCB DB with connection testing and commissioning complete all as specified and directed. |
| 63 | Supply and fixfor miniature Circuit breaker (MCB) single pole & neutral240 volt C curve 10 KA 32 Amps capacity IP 20 in the MCB DB with connection testing and commissioning complete all as specified and directed. |
| 64 | S&F two single core 6 sq mm for Sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100 Volts grade in and including PVC casing capping/ pvc conduit with fixing accessories including one run of 6 Sq mm copper conductor. (Note - Two runs of 6 Sq mm cable, one run of 6 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter.) |
| 65 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed. |
| 66 | Supply laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core. |
| 67 | Material and labour earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled aroundwith 15 cm thick alternate layers of charcoal dust and salt and connected to earth leadwire 4mm dia (8 SWG) by means of bolt, nut and check nutsand washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wiremesh, pcc 1:3:6 type C-1 in chambers RCC 1:2:4 type B-1 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways all as directed by Engr-In-Charge, complete all as shown in electric plate No 3 of MES SSR Part I |
| 68 | Taking Down of post top lantern LED type 40 watt 230 watt volts ACcomplete all as specified and directed. |
| 69 | Taking Down of XLPE stranded aluminium conductor of size 6 Sq mm 2 corecomplete all as specified and directed. |
| 70 | Excavation in trenchesnot exceeding 1.5m in depthdeep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified. |
| 71 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench) |
| 72 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 73 | Sandcushioningwith clean dry sandto cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cablecomplete all as specified.Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I. |
| 74 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site. |
| 75 | Supply, fixing, connecting and testing warm white post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver, lamp and all connecting accessories complete all as specified anddirected.(Make : Philips, Bajaj, Crompton and Surya) |
| 76 | Supply and laying XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 6 Sq mm 2 core complete all as directed. |
| 77 | M & L of GI tubing light grade 40 mm bore for passing through cables under the floor,along the pole complete including taking down all as speciifed and directed. |
| 78 | Deduct Credit for Demolished/Dismantled material Rs (-) 56,440.00 (Minus) as listed in Schedule \"A\" Part-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |