| 1 | Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof padding etc and removing of debris from outside MD land complete all as specified and as directed. |
| 2 | M & L for25 mm average thick PCC (1:2:4) Type B0 by using12.50 mm graded crushed stone aggregate as in roofwhere required over slabsand finishing the exposed surfaces faireven without using extra cement complete all as specified and directed. |
| 3 | M&L for preparing plastered surfaces and applying primer @ 0.30/Kg per sqm and applying tack coat of bitumen 85/25 @ 1.2 kg/Sqm laying 3.0mm thick polyster reinforced APP modified water proofing membrane weighing not less than 3.5kg/sqm 100 mm overlaps both longitudinally and transverselyby torchbonding overcoat of hot blown andone coat of bitumen basedpaint @1.20 ltr/sqm over APP membrane including removal of existing water proofing treamant on roof with plaster, sunken slabs, edges and vertical surfaces complete all as specified and as directed. |
| 4 | M&L for cutting grooves in brick wall of size 75mm wide 65mm deep and shapping to horizontal face of the groove with cement mortar 1:3.complete all as specified and as directed. |
| 5 | M&L for applying two coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over Bitumen surfacecomplete all as specified and as directed. |
| 6 | M & L 10mm thick rendering in CM 1:4 using water proofing compound over concrete surfacescomplete all as specified and directed. ( Note : WPC measured and paid separately) |
| 7 | Supply only water proofing compound.complete all as specified and as directed. |
| 8 | Demolition of cement concrete in any desscriptionand any positionpaving exc 15 cm thickness below and above ground level complete all as specified and as directed. |
| 9 | Taking down the plaster incl existing treatment in sunken portion , washing down with water and applying 15mm tick plasterin CM 1:4 with 3% WPC all around incl floors and applying Shaliu Urethane BTD two coats @ 1.5 Kg/Sqm each Coat (Apply 2nd Coat after 6 Hrs) over a coat of Shali Pime WP @ 200gm/sqm and Provide 40mm GI Spout Pipe complete all as specified and as directed.(Note : Supply of water proofing compound will be measured and paid separately .) |
| 10 | M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in filling of sunken portion etc complete all as specified and directed. |
| 11 | Dismanting asbests cement (corrugated, semi-currugated etc.) sheets including ridge in roof covering complete all as specified and directed. |
| 12 | Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area under 40 Sqcm not other wise provided for, complete all as specified and directed. |
| 13 | S & F prepainted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPAasin roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 14 | S&F pre painted gal valume aluminium zinc coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not other wise provided for. complete all as specified and directed. |
| 16 | S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A complete all as specified and as directed. |
| 17 | Dismantling posts/struts (wood, steel or RCC) any section including taking out embedded portion from concrete/brick masonry etc andmaking good disturbed ground incl barbed wire complete all as specified and directed . |
| 18 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard or dence soil complete all as specified and as directed. |
| 19 | M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate) complete all as specified and as directed. |
| 20 | M & L forproviding cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in copings, roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed. |
| 21 | M&L for Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer. complete all as specified and as directed. |
| 22 | M&L for Preparatioin of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed. |
| 23 | Demolition of Brick or stone masonry built in cement mortar complete all as specified and as directed. |
| 24 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) as in manholes, septic tank, filter bed, walls, drains etc complete all as specified and as directed. |
| 25 | M & L for brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed. |
| 26 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 27 | M&L for Granite(of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platorms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixtureof pigment to match the shade of granite including 15mm thick screed bed and incl its dismantling complete all as specified and as directed. |
| 28 | M&L rendering 15mm thick in CM (1:4) mixed with water proofing compound @3% of the weight of cement or as per manufacturer\"s instruction on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and directedNote\"-Wpc shall be measured and paid seperately under relavant item |
| 29 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of 0.8 mm thick wall care putty and over a coat of alkali resistant primer complete all as specified and directed. |
| 30 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets.all as specified and as directed. |
| 31 | S & F Anodised aluminium snap gridframe work for false ceiling all as specified of grid size 605 X 605mm upto a height of 6Mtrs including M & L Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified upto a height of 8Mtrsincluding necessary scaffolding including complete all as specified and as directed. |
| 32 | S & F 4mmthick non asbestos fibre cement buildings \"E\" boards fixed or laid/inserted to timber/GI/aluminium frame work in ceiling complete all as specified and directed upto a height of 8Mtrs including necessary scafholding and formwork.complete all as specified and as directed. |
| 33 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level) complete all as specified and as directed. |
| 34 | M & L for 75mm thickPCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed. |
| 35 | S&F in repair rotational moulded polyethylene water storage tanks 500 litre capacityincl(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I including dismantling and taking down existing water tank complete all as specified & directed. |
| 36 | S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindlerical vertical with closed top) hoisted and fixed in position all as specified in SSR part I inclding dismantaling of existing damaged water tanks complete all as specified & directed. |
| 37 | S&F 25 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified & directed. |
| 38 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore.complete all as specified and as directed. |
| 39 | S&F PVC (SWR) pipes of 110mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or in floors and tacking down including complete all as specified and as directed. |
| 40 | S&F PVC (SWR) pipes of 75mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or laid in trenches or in floors and tacking down including complete all as specified and as directed.directed. |
| 41 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed. |
| 42 | S&F 25 mm bore CPVC pipes SDR 11 pipes & Plain CPVC SDR 11 fittings and fixed concealed to walls and ceiling or laid in floors including taking down complete all as specified and as directed |
| 43 | S&F in repairs of CPVC pipes 20 mm dya SDR 11 & plian CPVC SDR 11 fittings and fixed concealed in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed. |
| 44 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed. |
| 45 | M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) finished fair and even as in sub base flooring complete all as specifiead and as directed. |
| 46 | M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm or 450 x 300x 7mm , as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick plaster on wall in cement mortar 1:4 complete all as specified & directed. |
| 47 | M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exc 0.06 and not exceeding 0.11 Sqmin floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed. |
| 48 | S & F in repairs vitreous china squatting pan \"Orissa pattern\" size 580 x 440mm white with integral foot rest including replacement of \"P\" or \"S\" trap lime concrete bedding and making good floors complete all as specified and directed. |
| 49 | S&F EWC Pedestal pattern WC ,any colourinclEWC seat Cover,10 ltr capacity PVC ,LLFC,32 mm dia PVC flush pipe including CP Toilet holder etc complete all as specified and directed. |