Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 2 | Demolition of cement concrete (Un-reinforced) of any description andin any position not otherwise specifically provided for all as specified and directed. |
| 3 | Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. |
| 4 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 5 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm each complete all as specified and directed. |
| 6 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 7 | Dismantling AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed. |
| 8 | Dismantling of Wall and Ceiling Board (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab /Blankets, any thickness including Cover Fillets, complete all as specified and as directed. |
| 9 | Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed. |
| 10 | Dismantling Timber Scantlings, 40 Sqcm and over in Section, in any Position, in Unframed Work, complete all as specified and as directed. |
| 11 | Dismantling Timber Fillets, Rails, Posts, Rafters, Purlings, etc., under 40 Sqcm in Section, in any Position, as in unframed Work, complete all as specified and as directed. |
| 12 | Taking down cement plaster of any description on brick work or stone msonary wall including racking ot joints hacking for key scrubbing down with water etc. complete all as specified and directed. |
| 13 | Surface dressing not exc. 150mm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 14 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. or for cable protection not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 16 | Removing excavated material ( soils of any type) n exc. 50 mand depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 17 | Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed |
| 18 | Anti Termite Treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed |
| 19 | M&LHardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | M&L Moorum/red bajri filling in floors or pavings , laid in lyers 30 cm in thick spread , levelled and rammed including watering complete all as specifiedand directed by Engr-in-charge. |
| 21 | M&L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 22 | M&L Plain Cement Concrete type C-1, (1:3:6) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 23 | M&L for Precast reinforced cement concrete Type B-1 (1:2:4) (Using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoodsand similar articles with plain faces with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and directed Note: (i) Necessary form work shall deemed to be included in quoted rates. (ii) Reinforcement shall be measured and paid separately under relevant item of these schedule. |
| 24 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 25 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 26 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 27 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in Chajja / kitchen rack and the like complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 28 | M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressumm-ers, lintels over 1.5m span and the like complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 29 | Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of laddings, steps, cills, sushades, shelves, lintels etc and cutting chase for concealed water tubing or concealed coduit wiring etc and making good cutting grith n exc 10 cm girth on brick walls complete all as specified and directed. |
| 30 | M&L Brick work usingPulverizes fly ash bricks of class designation 75, straigth or curved on plan exc 6m mean radius built in CM (1:4) cmplete all as specified and directed. |
| 31 | M&L Brick Work with Half Brick work usingPulverizes fly ash bricks of class designation 75, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 32 | Use and waste for formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 33 | Use and waste for formwork to suspended slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 34 | Use and waste for Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, (upto 04 storey high of building) complete all as specified and as directed. |
| 35 | Use and waste of Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 36 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube,fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 37 | S&F Plain Colour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etccomplete all as specified and as directed. |
| 38 | S&F for Factory Made Solid PVC Moulded Door Shutter With Wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site complete all as specified and directed. |
| 39 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed. |
| 40 | S&F for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.complete all as specified and directed. |
| 41 | M&L 1.50mm thick power coated aluminium , three track sliding window with three nosshutters made ofaluminium section as per drawing no CWE/KOL/TD-33 of section no 1F-1F including necessary jointing cleats, glazing clips, rubber neoprene packing, roller,locking arrangement, handles 2 Nos , anodised aluminium snap beading screws etc.Complete all as specified and as directed.Note Nos :- (i) All window memberincluding fitting & fixture i.eframe, track, shutter frame, etc shall be deem toincluded quoted rate. Only measure opening size of window.(ii)Only Glass for window & wire mesh shall be measure and paid separately under relevant items of BOQ . |
| 42 | S&F powder coated aluminium ventilators with louvers and glazing including frame of section over all size of window 600X450mm complete with following specification.(a) Alu frames of size 45x45x1.2mm (b) Rail & Stile 45x45x1.2mm thick (c) 4.80mm thick frosted sheet glassNote :- All ventilators/louvers memberincluding fitting & fixture shall be deem toincluded quoted rate. Only measure opening size of ventilators/louvers |
| 43 | S&F Stainless Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed |
| 44 | S&FAluminium anodised, barrel tower bolts of extruded section, 200 mm long and fixed with steel screws complete all as specified and directed. |
| 45 | S&F Extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified and directed |
| 46 | S&F 250mm long Aluminium alloy, anodised, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed. |
| 47 | S&F 300mm long Aluminium alloy, anodised, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed. |
| 48 | S&F Floor door stopper of aluminium aloy body and tongue, anodised with hard drawn steel spring (overall length of cover plate 150mm) complete all as specified and as directed. |
| 49 | S&FMild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and as directed. |
| 50 | S&F Fancy type, Powder coated 20/25 mm dia of drapery rod fixed in position as in repair complete all as specified and as directed |
| 51 | S&FBracket for fixing Fancy type,Chromium Plated 20mm dia curtain rod/ drapery rod etc as in repair complete all as specified and as directed. |
| 52 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed. |
| 53 | S&FMild steelTMT bars 6 ot 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (upto 04 storey High of building)complete all as specified and as directed. |
| 54 | M&L Mild steel TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 55 | M&L Mild steel Work in Tubular Trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conform-ing to IS:1161-1979 grade St.-240, complete all as specified and as directed. |
| 56 | M&L Rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-290 (Gde-E-165) quality A complete all as specified and directed. |
| 57 | S&F Mild steelPlates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentconforming toFe-410-W (Gde-E- 250 quality -B) complete all as speci-fied and as directed. |
| 58 | M&LMild steelFramed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 59 | S&F16-20mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15cm but nexc 22.5cm long complete all as specified and directed |
| 60 | M&L for Pressed steel frames for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate |
| 61 | Supply and fixGalvanized iron pipe, 40mm bore, light grade with all fittings, laid in floor , wallsfor cable proction complete all as specified & directed. |
| 62 | S&F Welded steel wire fabric weight not more than 4Kg/Sqm fitted by mild steel nails complete all as specified and directed. |
| 63 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed. |
| 64 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steelsheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 65 | M&L 4mm thick suspended false ceiling HPSC (high pressure steam curved) pre-primered fibre cement non asbestous building board similar to E-Board Classic placed in a grid of size 605x605mm with aluminium powder coated angle/channel/tee section duly suspended with 4mm dia GI hanger fixed with GI hooks 4mm dia and fastner as required at the site including two coat of oil bound distemper complete all as specified and directed.Detail of section are as under:-(i) Aluminium Angle 25mm x 25mm x 1.5mmt thick.(ii) Aluminium Cross Tee 25mm x 25mm x 1.5mmt thick.(iii) Aluminium Main Tee 25mm x 38mm x 1.5mmt thick.Note:-The bidder quoted rate included for all straight, Raking or circular cutting, wastage on ceiling board |
| 66 | M&L Cement Concretetype D2(1:4:8) using 40mm graded crushed stone aggregate 75mm thick as in sub base of floor, foundation filling etc complete all as specified and as directed. |
| 67 | M&L for 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in sub-base, finished Concrete Surfaces Even and fair complete all as specified and directed |
| 68 | M&L for 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection laid in panels, finish the top surfaces even and smooth without using extra cement complete all as specified and directedNote:- Construction joints will be provided at interval of 2.5m length and filled with bitumen 80/20 mix with sand in ratio of 1:3 and cost of the same shall be deemed included in quoted rate |
| 69 | M&L 100mm thick PCC (1:2:4) type B-2 (Using 40mm graded stone aggregate) as in sub base for path/hard standing cement complete all as specified. |
| 70 | M&L Cement Concrete type B0 (1:2:4) (12.5mm graded aggregate) 25mm thick, in Flooring, finishing concrete surfaces even and smooth complete all as specified and as directed. |
| 71 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqmin Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortarcomplete all as specified and as directed. |
| 72 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqmin Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortarcomplete all as specified and as directed. |
| 73 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. |
| 74 | M&L Glazed Ceramic Coloured Tile 450x350x7mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. |
| 75 | M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. |
| 76 | M&L Pre polished Chequered cement concrete tiles of size 300mm x300mm x25mm thick, with grey cement and no pigment, jointed in neat cemnt slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6complete all as specified and as directed. |
| 77 | M&L Rendering 15mm thick in Cement Mortar on fair faces of brick work or concrete surface of external wall in two layer, first layer 10 mm thick in cement morter (1:4) and top layer 5 mm thickin cement morter (1:4) using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and as directed. . (NOTE:-WPC shall be measured andpaid separately) |
| 78 | M&L rendering 15mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces even & fair without using extra cement complete all as specified and directed |
| 79 | M&L rendering 5mm thick in CM (1:3) as in ceiling surfaces even & smooth without using extra cement complete all as specified and directed. |
| 80 | \"Supply only\" liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA/Icannano |
| 81 | M&L Preparing new Surfaces of wall and applying Three Coats of White Wash, complete all as specified and as directed. |
| 82 | M&L Preparing new Surfaces of Ceilng and applying Three Coats of White Wash, complete all as specified and as directed. |
| 83 | M&L Preparing new Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 1.5mm thick (appx) water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 84 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 1.5mm thick (appx) water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 85 | M&L preparing newly plastered surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 86 | M&L complete removal of old decorated surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 87 | M&L Preparing new Surfaces of Walls and applying Two Coats of Cement Base Paintover a coat of primer complete all as specified and as directed. |
| 88 | S&FTinted glass with sheet glass 4.80mm thick , pin head type and glazing in squaresexc 0.5 sq. M in each panecomplete all as specified and as directed. |
| 89 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staplescomplete all as specified and as directed. |
| 90 | M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. |
| 91 | M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed. |
| 92 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation,etc up to four stories height of bldgs. complete as all specified and as directed. |
| 93 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation,etc up to four stories height of bldgs. complete as all specified and as directed. |
| 94 | S&Fin repair single socketed UPVC (SWR) pipe Type \"B\" 75mm bore with rubber ring joint any radius complete all as specified and directed. |
| 95 | S&F UPVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), Type \"B\" single socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and as directed. |
| 96 | S&F in repair PVC (SWR) junction single (Double T) equal or unequal 110mm bore complete all as specified and directed. |
| 97 | S&F UPVC (SWR) Bend 75mm bore (dia), any type etc. and Jointing with Solvent Cement,complete all as specified and as directed. |
| 98 | S&F UPVC (SWR) Bend 110mm bore (dia), any type etc. and Jointing with Solvent Cement,complete all as specified and as directed. |
| 99 | S&F UPVC (SWR) Nahani/Floor Trap 75mm bore (dia) Outlet, Plain with Grating and Jointing with Solvent Cement complete all as specified and as directed. |
| 100 | S&FUPVC (SWR) 75mm bore cowls and Jointing with Solvent Cement complete all as specified and directed. |
| 101 | S&FUPVC (SWR) 75mm bore Branch pieces, double (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors and Jointing with Solvent Cement complete all as specified and directed. |
| 102 | S&FUPVC (SWR) 110mm bore Branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors as in repair complete all as specified and directed. |
| 103 | S&FStack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof Bore in pipe in 75mm to 150mm complete all as specified and directed. |
| 104 | S&F PVC connection 15mm size with PTMT nut of length 450mm complete all as specified and directed. |
| 105 | S&F Brass chromium plated fancy type pillar tapscrewed for 15 mm boreof pipeetc.incl necessary fittings & fixtures complete all as specified & directed. |
| 106 | S & F in repair for chromium platedBib taps for 15 mm bore pipe complete all as specified and directed. |
| 107 | S & Fin repair 15mm bore brass chromium plated Angular Valve with Wall Flange complete all as specified and directed. |
| 108 | S & F for brass chromium plated two way bib tap with Wall Flange screwed for 15 mm bore pipe complete all as specified and directed. |
| 109 | S & F in repair for chromium plated Health faucet with 8mm Dia, 1.2 Meter long flexible tube and wall hook with N.R.V (Back Flow Preventer) complete all as specified and directed. |
| 110 | S&F Stainless Steel Towel rail of size 15mm dia 600mm long decorative type fixed with walls including necessary fittings etc complete all as specified and as directed. |
| 111 | S&FGlass shelf assembly consisting of 5.5 mm thick sheet glass self 19-12 cm wide,60 cm long with chromium plated brackets guard andrailing fixed in position with necessary fixing arrangement complete all as specified and directed. |
| 112 | S&F Mirror Bevelled Edge 600x450mm, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Ply-wood and fixed to Wooden Plugs with Chro-mium Plated Brass Screws and Cup Washers , complete all as specified and as directed. |
| 113 | Supply and fix in repairs Vitreous China squatting pan of‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding andconnection to trap, and to flushing pipe, antisyphonage pipe, etc. complete including making good to floorall as specified and directed by the Engr-in-Charge. |
| 114 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and excluding 10 litre capacity low levelFlushing Cistern matching with water closet colour with inlet ball valve float handle and providing 32mm dia PVC flush pipe including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging devicecomplete all as specified and as directed. |
| 115 | S&F vitreous China Urinal of size 355x340x535 mm with Spreader Hole and Fixing Accessories complete including providing & fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with & including 60mm long brass screw, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe ,grating and union for discharge pipe and including 40mm PTMT waste coupling with 32mm diawaste pipe and PTMT spreader (Exclusive of fixing supply pipe to flushing cistern ) ,complete all as specified and directed. |
| 116 | S&F in repair for vitreous China urinal half stall type (back or cornerwall type) complete including providing & fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with & including 60mm long brass screw, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe ,grating and union for discharge pipe and including 40mm PTMT waste coupling with 32mm diawaste pipe and PTMT spreader (Exclusive of fixing supply pipe to flushing cistern ) ,complete all as specified and directed .. |
| 117 | Supply and fixing in repair 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as directed. |
| 118 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 119 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 500Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe and including PTMT Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ballincluding Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. |
| 120 | M&L for 150mm dia Reinforced concrete pipes, class NP-3, laid and jointed with collars complete all as specified and directed. |
| 121 | M&L for Concrete bed Type C-2 (1:3:6) (Using 40mm graded crushed stone aggregate) to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 122 | Taking down carefully existingunserviceable copper/aluminiumpoint wiring (light, fan, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators, FTLfittings and making goodto the disturbedsurface complete all asdirected by Eng-in-Charge. |
| 123 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps incl Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 124 | All as per item No.123.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 125 | All as per item No.123.00 here-in-before but one 3pin switch socket outlet 5A on independent board complete all as specified and directed by engineer incharge. |
| 126 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 2.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 2.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one Switch socket combination 15 amps incl Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed. |
| 127 | M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earthand connecting to earth dolly for one 3pin switch socket outlet 5A on independent board complete all as specified and as directed.Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 128 | S&FSwitch socket combination multipurpose 2 in 1, 3 pin 15 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 129 | S&F Ceiling rose surface bakelitethree terminals 240 volts complete all as specified and as directed. |
| 130 | S&F switch piano modular flush type 5/6 Amps 230V AC 1 module complete one way complete all as specified and directed by Engineer-in-charge. |
| 131 | S&F modular socket out let 3 pin 5 Amps flush type 2 module complete all as specified and directed by Engineer-in-charge. |
| 132 | S&F modular switch socket outlet 2 module multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch complete all as specified and directed by Engineer-in-charge. |
| 133 | S& F modular electronic step type fan regulator 2 module by step type 230 volt complete all as specified and directed by Engineer-in-charge. |
| 134 | S&F modular bell push 1 module flush type 5 Amps complete all as specified and directed by Engineer-in-charge. |
| 135 | S&F sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 1/2 modules complete all as specified and directed by Engineer incharge. |
| 136 | All as per item No.135.00here-in-before but for 3 modules. |
| 137 | All as per item No.135.00 here-in-before but for 8 modules. |
| 138 | S&F modular cover plate with frame for fixing of modular switches/sockets complete for 1/2 modules complete all as specified and directed by Engineer-in-charge.Note:- switch and sockets will be measured and paid separately. |
| 139 | All as per item No.138.00 here-in-before but for 3 modules. |
| 140 | All as per item No.138.00 here-in-before but for 8 modules. |
| 141 | S & F surface & wall mounted LED 2 feet with 1X10 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specification:-(i) Housing- Extruded polycarbonate(ii) IP rating- IP 20(iii) Front cover - Acrylic/ polycarbonate cover(iv) Mounting - Suitable for wall/ Ceiling Mounting(v) Finish- Smooth Finish(vi) Lamp- high bright LED(vii) LED efficacy (Lm/Watt) - Not less than 120 Lm/Watts(viii) Colour Temperature- Not less than 5700K(ix) Colour Rendering Index (CRI)- Not less than 80(x) Life- Not less than 25000 hours of operation(xi) Optics- designed for optimum light distribution(xii) Control Gear - Inbuilt Electronic driver with APFC PF not less than 0.95 and THD not more than 20% of the standard operating voltage 180-270V AC 50 Hz(xiii) Surge protection- Inbuilt surge protection of minimum 2 KV(xiv) aluminium heat sink- As per OEM\"s Design(xv) Bidder has to compulsorily submit the LM-79 and LM-80 NABL accredited lab test report for the offered LED has to be structured in the sequence. |
| 142 | S & F surface & wall mounted LED 4 feet with 1X20 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specification:-(i) Housing- Extruded polycarbonate(ii) IP rating- IP 20(iii) Front cover - Acrylic/ polycarbonate cover(iv) Mounting - Suitable for wall/ Ceiling Mounting(v) Finish- Smooth Finish(vi) Lamp- high bright LED(vii) LED efficacy (Lm/Watt) - Not less than 120 Lm/Watts(viii) Colour Temperature- Not less than 5700K(ix) Colour Rendering Index (CRI)- Not less than 80(x) Life- Not less than 25000 hours of operation(xi) Optics- designed for optimum light distribution(xii) Control Gear - Inbuilt Electronic driver with APFC PF not less than 0.95 and THD not more than 20% of the standard operating voltage 180-270V AC 50 Hz(xiii) Surge protection- Inbuilt surge protection of minimum 2 KV(xiv) aluminium heat sink- As per OEM\"s Design(xv) Bidder has to compulsorily submit the LM-79 and LM-80 NABL accredited lab test report for the offered LED has to be structured in the sequence. |
| 143 | S&F LED bulb 12 Watts 240Volts 50 hz with angular PVC/ Policarbonate bulb holder having luminous Efficacy of minimun 110 Lm/ Watts and life of atleast 15000 Hours with in built surge protection of Minimum 2 KV ,opearting temperature of 0 C to 35 C , colour rendering index of 80 , colour temoerature of Min 6000K with start up time less than 2seconds, voltage withstand range of 140V- 270V complete all as specified and as directed. |
| 144 | S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 50mm dia light grade GI pipe bent to shape of 45\"\" 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 145 | Taking down unserviceable rusted / damaged MCB DBs of any type including MCBs and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. |
| 146 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 4 way single pole and neutral double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 147 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 8 way SPN double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 148 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 12 way SPN double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 149 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 4 way TPN double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 150 | S&F MCB 6 to 32 Amps, SP, 240 Volts , \"C\" curve breaking capacity 10 kAcompleteall as specified and as directed. |
| 151 | S&F MCB 6 to 32 Amps, DP, 240 Volts , \"C\" curve breaking capacity 10 kAcompleteall as specified and as directed. |
| 152 | S&FMCB 40 to 63 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 153 | S&FMCB 40 to 63 Amps, FP 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 154 | Taking down aluminimum sub mainwiring alongwith dameged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complee all as directed |
| 155 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 2.5 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 25 mm dia including all fittingscomplete all as specified and as directed.Note:- Two runsof 2.5 Sqmm conductor as main wireand one run of 2.5 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 156 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 25 mm dia including all fittingscomplete all as specified and as directed.Note:- Two runsof 4 Sqmm conductor as main wireand one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 157 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 25 mm dia including all fittingscomplete all as specified and as directed.Note:- Two runsof 6 Sqmm conductor as main wireand one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 158 | Taking down and opening out the ceiling fan/wall mounted upto1400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots complete including materials like split pin,rubber reel etc reassembling and refixing of fan complete including if any S required for fixing fan and incl 1.5 mtr length connecting rod all as specified and as directed. Note : Spare parts shall be measured & paid separately. |
| 159 | M&L for Rewinding of ceiling or wall mounted fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed by Engineer-in-charge. |
| 160 | Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan as per existing one complete. |
| 161 | Supply only capacitor of 2.5 mfd for Ceiling fan as per existing one complete. |
| 162 | M&L for painting of ceiling fan/wall fan/exhaust fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed by Engineer-in-charge. |
| 163 | Taking down and opening out the exhaust fan upto 450 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots rubber reel etc. reassembling and refixing of fan complete including all as specified and as directed. Note : Spare parts shall be measured & paid separately. |
| 164 | M&L for Rewinding of exhaust fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed by Engineer-in-charge. |
| 165 | Supply only ball bearing suitable for exhaust fan as per existing one complete. |
| 166 | Supply only capacitor 3.15 mfd for exhaust fan as per existing one complete. |
| 167 | M&L for painting of exhaust fan of any size and sweep complete, in situ with approved colour synthetic enamel paint by spraying including filling with cavities with filler, one coat after cleaning all dust etc. |
| 168 | Taking down unserviceable ceiling fans and supplying and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with all the connection as directed. NOTE- unserviceable fans to be deposited in MES Storeyard. |
| 169 | Taking down unserviceable exhaust fans and supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete with all the connection as directed. NOTE- Old unserviceable ones to be deposited to MES Store. |
| 170 | Supply and fix Aluminium Louver for existing exhaust fan ofsuitable size and type including taking down old one complete with all the connection as directed. |
| 171 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 35 Sqmm 3.5 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 172 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 173 | Supply and laying in trenches, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail