| 1 | NOTES :-In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly. |
| 2 | Dismantling/removing the textile coverings and cover fillets all as specified |
| 3 | Demolition of plain cement concrete of any description in any position as inpadding concrete, sunken slabs coping, benching, kerbs or mud stops etc and removing the debris outside MOD allas psecified by engineer in charge |
| 4 | M&L PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in terrace (padding layer )finished even surface of 25 mm thickcomplete all as specified and directed. |
| 5 | M&L for rendering 10 mm thick in CM 1:3 on concrete roof slabs including mixing water proofing compound at 3% by weight of cement (but excluding the cost of cement), finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 6 | M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, using water proofing compound at 3% by weight of cement but excluding the cost of WPC ( water proofing compound should be measured and paid seperately) complete all as specified and as directed. |
| 7 | M&L for cleaning the roof surface and applying oil bond bitumen primer @ 0.20 kg/sqm providing and laying 4 mm thick APP modified water proofing membrane weight not less than 4 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm having soften point not less than 140 degree centigrade tensile strength not less than 800/N/sqm cum tearing strength 180N with minimum of 10 cm side laps and 15cm end laps by application of torch applying a coat of blown grade hot bitumen over the membrane @ 1.2 kg/sqm and providing garnish with solar reflective bitumen aluminium paint @ 0.1 kg/sqm over completed area of membrane complete all as specified and as directed. complete all as directed. |
| 8 | Supply only integral water proofing compound as per manufactures instruction. |
| 9 | Demolition ofplain cement cement concrete/terrazo tiles with cement mortor bedding in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing the debris outside MOD land all as specified by engineer in charge |
| 10 | M&L for 40 mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate)as in floor all as specified and directed, finishing cement concrete as in floorsfinished even and smooth without using extra cementand spike rolling to surfaces or making impressions of expanded metal,whilst the concrete is greenall as specified and directed |
| 11 | M&L Wirebrushingandcleaningtop surface of tiles, lime terracing or cement concrete,including flashings and junction of parapets, etc., and surface painting,with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m, blinded with grit or pea size gravel @0.006 cu.m per sq.m, and lightly tampered (areaof flashings,etc., shall be added to the roof area |
| 12 | S&F Cement concrete tiles 30cmx 30cm x 22mm thick with grey cement and pigment including 15 mmm thick screed bed or bedding layer in CM 1:6 as in base to floor finish. |
| 13 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) |
| 14 | Taking down plaster on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. |
| 15 | M&L for 15 mm thick plastering on fair faces of brick work or concrete surfaces in two layer with 10 mm thick in CM 1:6 and top 5 mm thick in CM 1:4, mixing water proofing compound at 3% by weight of cement (but excluding the cost of WPC) finished the surfaces even and smooth without using extra cement. |
| 16 | M&L for 10 mm thick plastering in CM 1:3 on fair faces of brick work or concrete surface as in ceiling including finishing the surface even and smooth without using extra cement |
| 17 | M&L for preparing new plastered surface of ceiling and applying 2mm thick putty finish to obtain smooth finish in ceiling surface and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 18 | M&L for preparing new plastered surface of wall surface and applyingTwo or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by the Engineer-in-chargeand as per manufacturers instructions |
| 19 | M&L for complete removal of existing treatment of wall and applying 2mm thick putty finish to obtain smooth finish on old wall surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 20 | M&L for complete removal of existing treatment of ceiling and applying 2mm thick putty finish to obtain smooth finish wall surface and applying two coats of distemper over a coat of primer complete all as specified and as directed. |
| 21 | M&L for complete removal of existing treatment on walls, Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by the Engineer-in-chargeand as per manufacturers instructions |
| 22 | M&L for Flush/raised pointing in CM 1:4 to squared rubble masonry, coursed or uncoursed in repairs |
| 23 | M&L for preparing the surface of stone masonary/ concrete surfaces which includes cleaning,sanding and filling any imperfections to create smooth dry base and applying primer to enhance adhesion and durability as per manufactures instructionsand applying 2 coats ofthin even coats exteriorPU magnum/Aqua water proofing coating/ paint using spray gun ,brush or roller allowing each coat to dry completelyon old surfaces complete all as specified and as directed by the Engineer-in-chargeand as per manufacturers instructions |
| 24 | Demolition of brick work built in CM including All Quions, arches, pillars etc |
| 25 | M & L for Pre-cast cement concrete block masonry with solid blocks, Type C11:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete |
| 26 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 ,finished even and smooth without using extra cement |
| 27 | S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including Taking up or down steel tubing and connections including cleaning for refixing or removing to store 15 mm bore |
| 28 | S&F 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including Taking up or down steel tubing and connections including cleaning for refixing or removing to store 20 mm bore |
| 29 | Taking up or down steel tubing and connections of 25 mm dia , including cleaning forRefixing old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) |
| 30 | Taking up or down steel tubing and connections of 20 mm dia , including cleaning forRefixing old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) |
| 31 | S&F Brass elbow 20(3/4 x 1/2)mm dia all as specified and as directed by engineer in charge |
| 32 | S&F Brass tee 20mm dia all as specified and as directed by engineer in charge |
| 33 | S&F Male Brass Threaded Adaptor 20mm dia (MTA/ MBTA) )all as specified and as directed by engineer in charge |
| 34 | S&F Female Brass Threaded Adaptor (FTA/ FBTA) 20mm dia all as specified and as directed by engineer in charge |
| 35 | S&F Tank Adaptor 25mm dia all as specified and as directed by engineer in charge |
| 36 | S&F union of size of 25mm dia all as specified and as directed by engineer in charge |
| 37 | S&F Gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed 25 mm bore |
| 38 | Dismantling water tank of capacity exc 500 & n.exc 1000 ltrs |
| 39 | Dismantling water tank of capacity exc 250 & n.exc 500 ltrs |
| 40 | S&F 1000 ltrs capacity Rotational moulded polythene water strong tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed |
| 41 | S&F 500 ltrs capacity Rotational moulded polythene water strong tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed |
| 42 | S&F in repairs Ball valves high pressure of PTMT with eppoxy coated Aluminium rod & high density plastic ball screwed for iron pipes and fixed 25 mm bore (Minimum weight 455 gms) |
| 43 | Disconnecting existing tanks, setting aside (or loweringif required)forrepairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaningrepairing, etc. measured separately) of capacity exc 250 ltr but not exc 500 Ltr |
| 44 | Disconnecting existing tanks, setting aside (or loweringif required)for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaningrepairing, etc. measured separately) of capacity exc 500 ltr but not exc 1000 Ltr |
| 45 | Demolition and breaking up of AC/PVC drain pipes 100 mm dia set in CM |
| 46 | S&F PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm in repairs |
| 47 | S&F 110 mm bore PVC (SWR) junction single, (single T) all as specified and as directed |
| 48 | S&F 110 mm bore PVC (SWR) junction single, (single T) with access door all as specified and as directed |
| 49 | S&F 110 mm bore PVC (SWR) bends any radiuis all as specified and as directed |
| 50 | S&F 110 mm bore PVC (SWR) bends with access door any radiuis all as specified and as directed |
| 51 | Demolition of RCC Concrete of any description and in any position not otherwise specifically provided for. |