| 1 | Dismantling timber scantlings in unframed work 40 sq. cm and over in section fixed in any position complete all as specified and as directed. |
| 2 | S&F for Rolled sections of grade Fe 410W (Gde E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 3 | M&L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primercomplete all as specified and as directed. |
| 4 | Dismantling AC corrugated or semi corrugated etc sheets in roof coverings complete all as specified and as directed. |
| 5 | M&L forPre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of anycolour having tensile strength of 550 Mpa as in roof covering/ cladding towall, fixed with self tapping screws complete all as specified and directed.Note:- Rate shall be inclusive of making good disturbed portion with two coats of OBD. |
| 6 | S&F forPre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridgesfixed with self tapping screws complete all as specified and directed. |
| 7 | M&L for cement concrete Type B1 1:2:4 (using 20mm graded crushed stoneaggregate) as incopings and the like ncluding weathering,slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 8 | Dismantling boarding, any description, fixed in any position with nails.complete all as specified and as directed. |
| 9 | Providing and fixing tiled false ceiling of size(600x600)mm in true horizontal level suspended on interlocking T-24Grid of hot dipped galvanized corrosion free becase of the zinc coating 120GSM sections. It consists of main\"T\" runner of size 24x32x0.3x3000mm, cross\"T\" ofsize 24x32x0.3x1200mm, secondary cross\"T\" of size 24x32x0.3x600mm and PPGI wall angle of size 24x24x0.4x3000mm. The GI powder coated wall angle24x24x0.4x3000mm fixed along the perimeter of the ceiling to Walls, partitions or columns etc.,with wooden screws at 300mm centers placed at 600mmc/c. is fixed with Rawl Plug 08x45mm creating 1200mmx1200mm grid. Main-T runners 24x32x0.3x3000mm are then suspended at 1200mmc/c from ceiling using 2mm GIwire. The cross T sections of 24x32x0.3x1200 mm is interlocked between the main T at 600mm center to centert of or magrid of 1200x600mm and then secondary cross \"T\"24x32x0.3x600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends having length more than 600mm are to be supported independently. Finally the PVC tiles of size 595x595x8mm having PVC lamination infront side & Aluminum foil back on rareside need to be layed on the above grid frame. The PVC tile has humidity resistance RH 90%, Break strength of>160N, Fire resitance of Class AG3, 8624-1997 and NRC-0.15. complete all as specified and as directed.Note : Colour of false ceiling shall be approved GE. |
| 10 | Taking down existing unserviceable point wiring of any type/ size of light/fan/power/two way/bell etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators etc and removal of unserviceable material out of site area complete all as specified and as directed. |
| 11 | Taking down existing unserviceable light fittings, security light fittings, bulk head fittings, fall ceiling light fittings etc. from any height of building complete all as specified & directed |
| 12 | Taking down existing unserviceable MCB\"s/MCCB\"s/Distribution boards any capacity complete all as specified & directed |
| 13 | Taking down existing unserviceable Sub Main wiring of any description complete all as specified & directed |
| 14 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal modular box of suitable sizes with 1.3mm thicknes for housing the modular switches, sockets, fan regulators etccomplete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.complete all as specified and as directed.Note :- (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 15 | All as per Sl item No 14 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator.complete all as specified and as directed. |
| 16 | All as per Sl item No 14 above, but for One 5 Ampssocket outlet point on the independent board.complete all as specified and as directed. |
| 17 | All as per Sl item No 14 above, but for One 5 Ampssocket outlet point on the same board.complete all as specified and as directed. |
| 18 | All as per Sl item No. 14 here in before, but for wire 2.5 Sqmm for Power point.complete all as specified and as directed. |
| 19 | Supply and fix in repair Modular switch 1 way 6A , 1-module complete all as specified and as directed. |
| 20 | Supply and fix in repair Modular switch 1 way 16A with indicator, 1-module complete all as specified and as directed. |
| 21 | Supply and fix in repair Modular socket, shuttered type, 6A - 3 pin 2 -module complete all as specified and as directed. |
| 22 | Supply and fix in repair Modular socket, shuttered type, 6/16A -combined 2-module all as specified and as directed. |
| 23 | S & F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed. |
| 24 | S & F lamp holder suitable for B-22 base lamps insulated body surface bakelite with back plate including LED Bulb 15 Watts complete all as specified and as directed |
| 25 | Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC batten type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make: Crompton CCS-100-20-65-HSL2-DP-NWH, Havells ENDURALINEARPROBS20WLED 865PCSSIND, Bajaj-BCLAB20WCWLEDXT |
| 26 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC batten type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.Make : Crompton CCS-103-10-65-SL-DP-NWH, Havells LHEXAZP7PN1W010, Bajaj-BCLAB10WLEDCWLED |
| 27 | S & F for Recesss mounting LED light fitting 2\" x 2\" panel of capacity 36 Watts powder coated white CRCA full glow suitable for 600 x 600 mm POP false ceiling including making electrical connection from ceiling rose to light fittinf complete all as specified and directed.Make:Crompton: LCTLRP-36-FO-CDL / HAVELLS VENUSEXL2X2PLR36WLED865SWH/WIPRO-CRCO10R036HE57G4 / Bajaj-BZRSQL43LXEWHODSD |
| 28 | S & F in replacement LED wall mounted Spot light fitting, 6 Watts, CCT- 4000K (warm white) of 450mm long mounted of circular base with flexible/adjustible focus angle complete with driver including connecting up with flexible copper conductor complete all as specified and directed. |
| 29 | S & F In replacement of old unserviceable Building security light fitting versatile pressure die-cast aluminium with high power LED 35 W as light source complete with LED 35 W 5000Kincluding bracketsmade out ofGI pipe 25 mm dia light gradepipebent to shape incl 02 Nos MS flate clamps inclnut bolts connectioncomplete all as specified and as directed.Make : Bajaj cat part No. ENXT P 24L WH CR PC SD, Crompto Cat No-LSTS-25-CDL-M, Havells Cat No-ENDURASUNDOWNSL25WLED 765PASYBOPCIHD. |
| 30 | S & F for Vertical loadline type TPN DB 4 way double door with prov of MCCB as incoming 4P, made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed . Make :- Havells, Legrand, Standard.Note :- MCCB shall be measured and paid separatly. |
| 31 | S&F for MCCBs 415V, 16KA, 100 amps 4 Pole suitable for DB including removing the existing unserviceable one complete all as specified and as directed. Make :- Havells, Legrand, Standard.. |
| 32 | S & F in replacement sheet metal enclosure MCB DBSPN 8 way, 240 volts double door with locking system complete all as specified and as directed . |
| 33 | S & F in repair for MCB SP 6 to 32 Amps 240 volts C- type complete all as specified and as directed. |
| 34 | S & F in repairfor MCB SPN 40 to 63 Amps 240 volts C- typecomplete all as specified and as directed. |
| 35 | M & L for Submain wiring with 2 runs of single core 6 sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. |
| 36 | All as per Item Sl No-35 above but using 3 runs of single core 2.5 sqmm. (for Bldg Security Lights)complete all as specified and as directed. |
| 37 | Disconnection and removing the existing unserviceable earthing and M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing oncomplete all as specified and as directed..(Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate). |
| 38 | Supply, laying & testing in replacementXLPEinsulatedarmoured heavy duty electric cable with aluminium conductor, 1100V grade, of size 3.5 Core 35 Sqmm complete fixed on wall with GI shaddles at 600 mm distance and making electrical connection from existing panel to new vertical TPN DB complete all as specified and directed. |
| 39 | Supply and fixing ceiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥)6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour complete all as specified and directed by the engineer-in-charge. Make : Gold Medal cat part no.SCFS 500748 / Bajaj Cat part No:ENERGOS 28 /Crompton Cat part No:ENERGION RIVIRA / Havells Cat part No:PRO 28BLDC |
| 40 | M & L for Tubes, Medium grade\" galvanised 15 mm dia, for hanging ceiling fan, the pipe shall be hang vertically from hook to the ceiling fan, making 02 Nos holes at both ends for fixing nut-bolts and clamps complete all as specified and directed |
| 41 | M & L for making Fan Hook using MS flat iron 40X6mm thick made to shape suitable for hanging ceiling fan on metal truss, 02 Nos MS nut, bolts and washers complete all as specified and directed |
| 42 | Supply and fix exhaust fan, metal body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete including making suitable size hole in wall, round shapeusing machine cutting only and making opening at any height and at any floor of the building for fixing of suitable dia pre-moulded PVC tail piece of required length for mounting of 300 mm dia mettalic exhaust fan includingwire mesh and making good the disturbed surfaces matching with existing colour, plastering, and clearing all debris and making the work area clean complete all as specified and as directed.Make: Havells Cat part No:Ventil air DSB/Gold Medal EFS851012 HAVAC PLUS /Crompton drift air plus300mm / Bajaj-Supreme plus |