| Sl. No. | Item Description |
| 1 | Taking down frames (including grills/wire mesh) with shutters n.exc 1.50 Sqm each (without taking off shutters from the frame) complete all as specified and as directed. |
| 2 | Taking down frames (including grills/wire mesh) with shutters n.exc 1.50 Sqm but n.exc 4.00 Sqm each (without taking off shutters from the frame) complete all as specified and as directed. |
| 3 | Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each.complete all as specified and as directed. |
| 4 | M & L for second class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.complete all as specified and as directed. |
| 5 | S & F for 35mm thick 2nd class hard wood glazed skeleton shutters open rebated and prepared to receive glass and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified & directed. |
| 6 | S & F for 30 mm thick flush shutter solid core construction with block board core and plywood face panels commercial type oon both side complete all as specified and directed. |
| 7 | S & F for 2nd class hard wood in fillets, square, rectangular in section wrought, secured with nails sectional area exc 13 sq cm and n.exc 25 Sq cm fixed in repairs.complete all as specified and as directed. |
| 8 | S & F for Solid PVC Door Frame of size 50mm X 47mm made out of 5mm wood grain printed PVC sheet reinforced with M S Square tube,supplying and fixing in opening as per manufacturers instructions and complete all as specified and as directed. |
| 9 | Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2, raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm prelam PVC sheet on back face, with particle board coresupplying & fixing in frame at site complete all as specified and as directed. |
| 10 | S&F for powder coated anodised aluminium frame (minimum thickness of powder coating 50 micron)for sliding windows, fixed/top hung frame for ventilators with one or more rebates including jointing cleats for fixing etc.including making good distrubed portion of wall complete all as specified and directed. |
| 11 | S&F for powder coated anodised aluminium(minimum thickness of powder coating 50 micron) three track sliding window shutters and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittingscompleteallasspecifiedand directed.(Note: Glass pan and wire mesh shall be measured and paid seperately). |
| 12 | M & L for framed work such as grills, gratings etc with ends of bars, framed guard bars, ladders etc and similar works conforming to Fe-290 Gde E-165.complete all as specified and as directed. |
| 13 | S & F for stainless steel 125mm butt hinges medium weight cold rolled.complete all as specified and as directed. |
| 14 | S&F for 200mmlong Aluminium, anodised, barrel tower bolts of extruded section.complete all as specified and as directed. |
| 15 | S & F for 150mm aluminium anodised handles.complete all as specified and as directed. |
| 16 | S & F for 300mm size aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of seat cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 17 | S & F for100mm aluminium hasp and staple complete all as specified and as directed |
| 18 | S & F for MS hold fases (FI 25X3, 250mm long) conforming to Fe-290, Gde E-165, complete all as specified and as directed. |
| 19 | M & L for PCC 1:3;6, type C1 (using 20 mm graded crushed stone aggregate) as in bed blocks for hold fasts etc including necessary form work complete all as specified and as directed. |
| 20 | S&F for 4mm thick plane glass pin head type and glazing with oil putty in square panes complete all as specified and as directed. |
| 21 | S & F for 4mm thick figured glass pin head type and glazing oil putty in square panes n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 22 | S&F for Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm.complete all as specified and as directed. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed.. |
| 24 | M& L for 25mm thick PCC 1:2;4 type B-0(using 12.55mm graded crushed stone aggregate) as in sub base of tiles and surface even and fair without using extra cement all as specified and directed. |
| 25 | M & L for Non skid ceramic coloured tiles 7 to 8mm thick (Squared/rectangular) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including laying over 15mm thick screed bed in CM 1:6 complete all as directed andas specified |
| 26 | M & L for Non skid ceramic coloured tiles 7 to 8mm thick (Squared/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed of 15mm thick in CM 1:6.complete all as specified and as directed |
| 27 | M & L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete in position laid on over 10mm thick screed in CM 1:3 on wall, complete all as specified and as directed. |
| 28 | M &L for granite 20mm thick (of any type) work table robed & polished cooking platforms and like over 15mm thick screed bed or bedding in layer of CM 1;4 for laying floor finishes incl pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite, and half moulded at one side including demolition of old stone any type complete all as directed and as specified |
| 29 | Demolition of brick work or stone boulders masonry built in Cement mortar (or) cement lime mortor including all quions, arches, pillars etc.complete all as specified and as directed |
| 30 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6m mean radinsbuilt in cement mortar 1:6.complete all as specified and as directed |
| 31 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built in, cement mortar 1:4complete all as specified and as directed |
| 32 | Taking down cement plaster/terrazzo finish on brick/RCC Chajja/parapet wall/stone walls of any description including racking out joints hacking for keys scrubbing down with water etc, complete all as specified and as directed. |
| 33 | M & L for rendering 15mm thick on concrete orbrick work in CM 1:6 finished even and smooth without using extra cement complete all as directed and as specified. |
| 34 | M & L for rendering 15mm thick on concrete or brick work in CM 1:4 finished even and smooth without using extra cement complete all as directed and as specified. |
| 35 | M & L for rendering 5mm thick in CM 1:3 rendering on cocrete surface such as ceiling chajjas etc finished even and smooth (without using extra cement) complete all as specified and as directed |
| 36 | Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcement to a depth of 10 mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chipper including high pressure water jetting to chipped concretand reinforcement and removal and disposal of debris within owners premises including all plant and machineries. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. Depth of chipping may very from 50 mm to150 mm complete with labor, machinery, tools etc. all a directed by Engg.in charge. The edges of repair locations shall be saw cut to a depth of at least 10 mm to avoid feather edgeing and provide a square edge. Removal of dust, loose particles, marine growth etc. from concrete surface manually by wire brush, mechanically or any other means to obtain a sound surface over areas other than above.complete all as specified and as directed. |
| 37 | Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover agent like Reebaklens RR of make Fosroc or Dr fixit/STP having Specific Gravity 1.16 - 1.22. The material to be applied to the rusted metal using brush and make leaving to dry for 30 mins & washing surface with fresh water as required to exposed reinforcement bars complete all as specified and as directed. |
| 38 | Providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP Std of make Fosroc /Dr fixit/STP, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs. and 300 C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete all as specified and as directed. |
| 39 | Providing and laying of polymer modified single component, alkaline resistant fiber reinforced, thixotropic, cementitious patch repair mortar Renderoc SP 40 of Fosroc /Dr fixit/STP that achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength (BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 micro strain. Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., where the thickness of application is average 30 mm in patches as per specification after applying bonding coat (bonding coat shall be payable separately). Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete all as specified and as directed. |
| 40 | Demolition of un reinforced cement concrete in any position and any thickness below and above ground level complete all as specified and asdirected. |
| 41 | M & L for rendering 10mm thick in CM 1:3 on roof concrete surface while concrete is green mixed with water proofing compound @ 3% by weight including finished the surface smooth and even without using extra cement or as per manufacturer\"s instruction.complete all as specified and as directed.Note:-WPC will be measured and paid separately. |
| 42 | M&L forpriming the plastered roof surfaces with bitumenous primer @ 0.30 kg over applying hot bitumen VG-30 1.2kg/Sqm and applying APP based polymeric membrane weighing 3 kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/per sqm) and on primed surface by forced torch application over that applying bitumen base alluminium Paint 0.2 Kg/Sqm complete all as specified and as directed. |
| 43 | M&L for 40mm Thick PCC (1:2:4) Type B1 by using 20mm graded crushed stone aggregate as in roof mixed with water proofing compound @ 3% of weight of cement or as per manufacturer\"s instruction , where required over slab and necessary form work and finishing the exposed surfaces fair even without using extra cement complete all as specified and as directed.Note:-WPC will be measured and paid separately. |
| 44 | M & L for rendering 15mm thick on concrete or fairfaces of brick work in CM 1:4, finished even and smooth without using extra cement mixed with WPC @ 3% of weight of cement or as per manufacturer\"s instruction complete,all as directed and as specified .After plastering the sunken surface, sunken portion to be filled with water and tested for 72 hrs (after required period of curing) to observe leakage/seepages, leakages/seapage if any shall be arrested by pressure grouting and re-tested till leakage/seepages completely stopped.After pointing test, the surface shall be dried and bottom and sides of the sunken slabs shall be treated, priming the plastered surface with bituminous primer conforming to IS-3384 @ 0.3 Kg per Sqm and applying a tack coat of industrial bitumen 85/25 @ 1.2 kg per Sqm over which applying using glass fibre base bituminous felt type II and grade 2 (conforming to IS-7193 1994) and applying one coat of hot blown bitumen of grade 85/25 @ 1.5 Kg per Sqm including 450mm long 25mm dia medum grade GI pipe shall be provided at the lowest in case of leakage.The joints in CI/GI/PVc pipes, Nahani traps, WC and P/S trap connection shall be made leak proof.The gap around the pipes in walls/beams shall be properly filled and sealed with water proof joints fillerscomplete all as specified and as directed.(Note:-WPC measured and paid separately) |
| 45 | M & L for PCC 1:3:6 type B0, (using 12.5mm graded crushed stone aggregate) as in levelling course including weathering slightly rounded or chamfered angles and throating over chajjas and adjancent to parapet wall as directed complete all as specified and as directed. |
| 46 | Supplying and laying of 20mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in walls/ floor/roof and trenches including taking down existing tube/pipecomplete all as specified and as directed. |
| 47 | Supplying and laying of 25mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in walls/ floor/roof and trenches including taking down existing tube/pipecomplete all as specified and as directed. |
| 48 | S & F in repair bib tap 15mm bore, fancy type, chromium plated, cast copper alloywith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 49 | S & F in repairs 15mm bore stop valves fancy type chromium plated screwed both ends for iron pipe for unions and fixed with long shank and cup (concealed type). complete all as specified and as directed. |
| 50 | S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm borecomplete all as specified and as directed. |
| 51 | S&F 600 mm long PVC connections, 15 mm dia with PTMT nuts, complete all as specified and as directed. |
| 52 | S & F in repair chromium plated125mm swivel shower complete all as specified and as directed. |
| 53 | S & F in repairs vitreous china squatting pan \"Orissa pattern\" size 580 x 440mm white with integral foot rest including replacement of \"P\" or \"S\" trap, including PVC low level flushing cistern 10 ltrs capacity,flush pipe of polythylene of low or high density or PVC 32 mm dia , PVC connection 15mmsize with PTMT nuts of length 450mm including cement concrete bedding and making good floors complete all as specified and directed. |
| 54 | Supply & fixing in repair vitreous china wash basin with padestal , white flat size 550x400mm incl bracket cutting for and pining in ends of brackets or erecting stand including PVC connection pipe 15 mm bore 450 mm long , waste coupling of PTMT , PVC waste pipe and Pllar cock complete all as specified and directed. |
| 55 | S & F for 600x450mm bevelled edge morror of selected equality glass mounted on 6mm thick AC building boardand fixed to wooden plugs width chromium plated brass screws and cup washerscomplete all as specified and as directed. |
| 56 | S & F for tubular towel ring brass chromium plated 20mm dia D type 60 cm, between the flangerscomplete all as specified and as directed. |
| 57 | S & F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including waste coupling and waste pipe and including bedding in cement mortar to dwarf wall or including fixing cantillever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. complete all as specified and as directed. |
| 58 | S & F in repair kitchen plate rack size (24x36x10\")made of stainless steel,complete all as specified and as directed.. |
| 59 | S& F forRotational moulded PVC water storage tank hoisted and fixed in positon of 500 ltrs capacity incl dismantling existing water tankscomplete all as specified and as directed. |
| 60 | S&F for20mm Ball valves high pressure of PTMT with epoxy coated aluminium rod and high dessity plastic ball screwed for iron pipe and fixed ( minimum weight 455 gms)complete all as specified and as directed. |
| 61 | S & F for 75mm dia, PVC (SWR) floor trap, plain with grating and jointing to waste pipe with solvent cement and fixed in PCC 1:2;4, type B1, complete all as specified and as directed. |
| 62 | S & Ffor 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed. |
| 63 | S & F for 110mm PVC (SWR) WC connector bend type complete all as specified and as directed. |
| 64 | S & F for 75mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed. |
| 65 | S & F for 110mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed. |
| 66 | S & F for 75mm bore PVC (SWR) branch piece with access door, single \"T\" equal or un-equal complete all as specified and as directed. |
| 67 | S & F for 110mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 68 | S & F for 75mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls/floor, complete all as specified and as directed. |
| 69 | S & F for 110mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls/floor, complete all as specified and as directed. |
| 70 | M & L for 75mm thick PCC 1:3:6 type C1, (20mm graded crushed stone aggregate) as in plinth protection laid in panels including finished the surfaces smooth and even without using extra cementcomplete all as specified and as directed. |
| 71 | M&L for Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat pink primer. complete all as specified and as directed. |
| 72 | M&L for Preparation of old steel surfaces (grill) of any description over 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 73 | M & L for applying three coats of white wash on wall including preparation of new plastered surfaces of wallcomplete all as specified and as directed. |
| 74 | M & L for applying one coat of white wash on ceiling including preparation of old plastered surfaces complete all as specified and as directed. |
| 75 | M & L for applying two coat of white wash on ceiling including preparation ofundecorated surfaces complee all as specified and as directed. |
| 76 | M & L for applying two coat of distemper oil emulsion on walls over a coat of primer over 1.0mm thick Birla wall care putty including preparation of new plastered wall surfaces complete all as specified and directed. |
| 77 | M & L for complete removalexisting treatment and applying two coat ofdistemper oil emulsion on walls over 1mm thick Birla wall care putty including preparation new wall surfaces complete all as specified and directed. |
| 78 | M & L for two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces of wallcomplete all as specified and directed. |
| 79 | M & L for complete removal of existing treatment and applying two coats of cement base paint over a coat of primer including preparation of old plaster surfaces of walls, complete all as specified and directed. |
| 80 | S & F forfancy type powder coated 20mm dia curtain rod with fancy type bracket fixed on wallcomplete all as specified and as directed. |
| 81 | S&F for 18 mm thick , prelaminated medium density fibre (MDF) , interior grade, prelaminated one side with decorative choice lamination and other sidebalancing white with lamination fixed with screw to timber/ steelframe work as inCB shutter, shelves etcwith PVC liping on all exposed edges on same texture and shade. Stainless steel cleat of suitable size will be use to fix the shelves of CB and cabinets. complete all as specified and as directed. |
| 82 | M & L for mirror polished Machine cut kota stone slab flooring 20 -25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm screed in CM 1:4 . complete all as specified and as directed. |
| 83 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm screed in CM 1:3 . complete all as specified and as directed. |
| 84 | Rounding to edges of kota stone slabs one edge, such as in steps, cooking platform, and other similar situations. complete all as specified and as directed. |
| 85 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level)complete all as specified and as directed. |
| 86 | M & L for 100mm thickPCC 1:3:6 type D-2 (using 40mm graded crushed stone aggregate) as in sub base. complete all as specified and as directed. |
| 87 | M & L for rubber moulded Chequered cement concrete tiles20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry with grey cement and no pigments in floors over a 20mm thick screed bed in CM 1:4. complete all as specified and as directed. |
| 88 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever requiredcomplete all as specified and as directed. |
| 89 | M&L for PCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in copings, plinth courses, bed plates, kerbs incl necessary formworkcomplete all as specified and as directed. |
| 90 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5m in depth for foundation on manholes etc, and area n.exc 10 Sqm on plan and getting out in Soft/Loose soil. complete all as specified and as directed. |
| 91 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar 150mm dia. complete all as specified and as directed. |
| 92 | M & L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) for 150mm dia pipe. complete all as specified and as directed. |
| 93 | M & L for SWG drain pipes grade \"A\" of 150mm internal dia laid in trenches and jointed in cement mortar 1:1complete all as specified and as directed. |
| 94 | S & F for PVC (SWR) gully trap of 125/110mm dia set and jointing with solvent cement complete all as specified and directed. |
| 95 | Demolition of RCC cover slab for manholes etc. complete all as specified and as directed. |
| 96 | M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded crushed stone aggregate as in cover slab for manholes etc.and set in cm 1:6. complete all as specified and as directed. |
| 97 | S&FTMT bars 10 mm dia and over and cut to length bent to shape required including cranking, bending, hooking ends and bending with MS wire not less than 0.9mm dia or securing with clips quality conformingcomplete all as specified and as directed. |
| 98 | M&L for Cutting into existing manholes for 150mm dia connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. complete all as specified and as directed. |
| 99 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) as in manholes, septic tank, filter bed, walls, drains etc complete all as specified and as directed. |
| 100 | M & L for rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces even and smooth without using extra cement as in manholes, septic tank, filter bed out let drain by using water proofing compound etccomplete all as specified and as directed. |
| 101 | Supply of Integral waterproofing compound. complete all as specified and as directed. |
| 102 | M&L for Plain cement concrete type C1(1:3:6)( using 20mm graded crushed stone aggregate) as in surface chanels and drainscomplete all as specified and as directed. |
| 103 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etccomplete all as specified and as directed. |
| 104 | Taking down existing unserviceable point wiring of any type/ size of light/fan/power/two way/bell etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators /security light/bulk head fittings etc and removal of unserviceable material out of site areacomplete all as specified and as directed. |
| 105 | Taking down ceiling/exhaust fans dismantling blades complete and deposited to MES yardcomplete all as specified and as directed |
| 106 | Taking down existing unserviceable Distribution boards with MCB\"s any size and any type complete all as specified & directed |
| 107 | Taking down existing submain wiring of any size or any type complete all as specified & directed |
| 108 | Taking down existing earthing with GI Wire/Strip complete of any size or any type complete all as specified & directed |
| 109 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point / fan point controlled by one switch.Note :- (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 110 | All as per Sl item No 110 above, but for One 5 Ampssocket outlet point on the same boardcomplete all as specified & directed |
| 111 | All as per Sl item No 110 above, but for One 5 Ampssocket outlet point on the independent board. complete all as specified and as directed. |
| 112 | All as per Sl item No. 110 here in before, but for OneBell point controlled by one, bell pushcomplete all as specified & directed |
| 113 | All as per Sl item No 110 above but for One light point controlled by two way switch complete all as specified & directed |
| 114 | All as per Sl item No. 110 here in before, but for wire 2.5 Sqmm for Power pointcomplete all as specified & directed |
| 115 | All as per item No 110 here in before but with cable 4 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dollycomplete all as specified and as directed. |
| 116 | Supply and fixin repair Modular switch 1 way 6A , 1-modulecomplete all as specified & directed |
| 117 | Supply and fix in repair Modular switch 2 way 6A , 1-modulecomplete all as specified & directed |
| 118 | Supply and fix in repair Modular switch 1 way 16A with indicator, 1-modulecomplete all as specified & directed |
| 119 | Supply and fix in repair Modular Bell push 6A 1 modulecomplete all as specified & directed |
| 120 | Supply and fix in repair Modular socket, shuttered type, 6A - 3 pin 2 -modulecomplete all as specified & directed |
| 121 | Supply and fix in repair Modular socket, shuttered type, 6/16A -combined 2-modulecomplete all as specified & directed |
| 122 | S & F in repairElectric Bell Ding-dong working on 230 volts AC Supply complete all as specified and as directed. |
| 123 | S & F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mmcomplete all as specified & directed |
| 124 | S&F for power module 240 V with 20 A MCB SP complete 4 module metal flush box cover plate plug & socketcomplete all as specified and as directed. |
| 125 | S&F for TV Socket outlet modular fixed to wall in concealedcomplete all as specified and as directed. |
| 126 | S & Fin replacement 20 W surface / wall mountedLED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPROLL20-221-XX-65/Havells ENDURALINEARPROBS20WLED865PCSSIND |
| 127 | S & F in replacement 10 W surface / wall mounted 2 feet LED batten light fitting poly carbonate input voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed Make:Crompton CCS-103-10-65-DP-NWH/ Havells LHEXAZP7PN1W010 / PHILIPS BN021LED12S 6500K PSU GR / WIPROLL20-111-XX-65 |
| 128 | S & Fin replacement LED light fitting 10W bulkhead luminaires, efficacy not less than 100 lm/w, rated life 25000 burning hours including LED light driver holder connecting up with three core flexible copper conductor cable IP 65 out door type metal bodyof suitable size complete all as specified and as directed Make: Crompton CIS-306-10-57-DP-NBK/ PHILIPS WT202W LED10S CW PSU S3 PC/ HAVELLS HEXAFT10WLED857SSYMBOPC /WIPRO LW07-141-XXX -57-G1 |
| 129 | Supply and fixingin replacement LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceilingcomplete all as specified and as directed.Crompton TRP-409-45-57-GL-NSG / PHILIPS BRP030LED35CWSLRGRPSUV1 / HAVELLS ENDURASUNDOWNSL45WLED765PASYBOPC/WIPRO |
| 130 | S & F in repair MCB SP 6 to 32 Amps 240 volts C- typecomplete all as specified and as directed. |
| 131 | S & Fin repair MCB SPN 40 Amps 240 volts C- typecomplete all as specified and as directed. |
| 132 | S & F in replacement sheet metal enclosure MCB DBSPN 8 way, 240 volts double door with locking systemcomplete all as specified & directed |
| 133 | S&F of sheet metal enclosure TPN DBs with 200 Amps rated bus bar of 4 way 415 volts with blank plate complete with double door complete all as specified and directed |
| 134 | S&F in repair MCB three phase and neutral (TPN), 100 Amps, 415 Volts,connecting with lugs, complete all as specified and directed |
| 135 | M & L for Submain wiring with 2 runs of single core 6 sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories for Surface wiring of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwingcomplete all as specified & directed |
| 136 | M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion including taking down old one all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate). complete all as specified and as directed. |
| 137 | M&L for earth continuity conductor 4 Sq.mm dia GI or steel wire complete all asspecified and directed. |
| 138 | Refixing of ceiling fans/exhaust fans /geysers complete all as specified & directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail