| 1 | Demolition ofPCC in Ground Floor and paving n exc 15 cm (below or above ground level). |
| 2 | Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc., removing serviceable tiles to store and rubbish off the premises. |
| 3 | M&L for PCC type D2 1:4:8 using 40mm graded stone aggregate, 75 mm thick as in sub base for floors, complete all as specified and directed. |
| 4 | M&L for Vitrified ceramic tiles, Light Shade 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match with and including provision of 15 mm thick screed bedding in CM (1:6), complete all as specified and directed. |
| 5 | M&Lfor machine cut kota stone slab flooring 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) all as specified and directed by Engineer-in-charge. |
| 6 | M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and fair w/o using extra cement |
| 7 | Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water all as specified |
| 8 | M & L for Cement plastering 15mm( thick in two layers -first layer 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster) on outer walls by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS- 2250-1981 and shall confirm 28 days compressive strength 10-15 MPA, bulk density 1600-1800 kg/cum and pull out bond strength->0.5 MPA complete all as specified and directed |
| 9 | M&L Finishing wall with Acrylic emulsion smooth exterior paint of reqd shade, new work (two or more coat) applied @ 1.67 Ltr/10 Sqm over and incl priming coat of exterior primer applied @ 2.20 Kg/10 Sqm complete. |
| 10 | M&L for Complete removal of existing treatment of wall surfaces and applying two coats of oil bond distemper over one coat of primer including 2mm thick wall care putty on wall all as specified & directed by Engineer-in- Charge. |
| 11 | M&L for Complete removal of existing treatment of wall surfaces Finishing walls with Acrylic Smooth exterior paint of required hade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) inculdingcomplete removal existing treatment of wall surfaces. |
| 12 | Taking down door chowket or frame incl shutter area exc 1.50 sqm but not exc 4 Sqm complete. |
| 13 | S &F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and decorative cast iron artical etc. Fe 410-W (Gde E-250) quality A |
| 14 | M&L for Second class 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as specified & directed by Engineer-in- Charge. |
| 15 | M&L for II nd class hard wood Glazed and skeleton shutters, 30 mm thick ,open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, cla-use 8.20 (a); supplied and fitted to chowkats. |
| 16 | Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe Fe 290 Gde E-165 |
| 17 | Supply and fix Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 18 | Supply & fix in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 19 | Hacking out old broken glass (any thickness, size, quality or description) frommetal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones |
| 20 | S&F 4 mm thick sheetglass ordinary quality and glazingwith oilputty in squaren exc 0.50 sqn in each pane. |
| 21 | S&F in repairs 100 mm long mild steel but hinges medium weight colld rolld. |
| 22 | S&F 150 mm long Aluminium anodised barrel tower bolt of extruded section. |
| 23 | Supply and fix 150mm long Extruded aluminium alloy handles, 150mm long fabricated type., anodised |
| 24 | S&F 300 mm long Aluminium allow anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow. |
| 25 | S&F floor door stopper of aluminium 150mm size. |
| 26 | Stainlesssteel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fency type, stops fixed with ss screws etc all as specified & directed as in repair .Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered as approved by Engr-In-Charge. |
| 27 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 28 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 |
| 29 | S &F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts :posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming toFe-290 Gde E-165 |
| 30 | M&L for Preparing new steel surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 31 | M&L for Preparing of old steel surfaces of any description exceeding 10 cm in width or girth and applying one coats of synthetic enamel painting over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 32 | Preparation of new wooden surfaces of any description, nototherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and direction. |
| 33 | Dismantling of wall ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets. |
| 34 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 35 | M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screw or as per manufacturers instructions.suitably placed in false ceiling grid 605mm x 605mm made of Aluminium anodised snap grid frame work all as specified |
| 36 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering |
| 37 | S & F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 38 | S & F Pre painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 39 | M&L for 100mm thick PCC ype D-2, 1:4:8 using 40mm graded stone aggregate as in sub bases all as specified. |
| 40 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. complete all as specified. |
| 41 | M&L For Type B1 1:2:4 (20 mm graded aggregate) Providing, cement concrete in kerbs of mud stops, rounded or chamfered on edges |
| 42 | Taking down carefully existing point wiring of any description light, fan,sockets,bells etc) complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the disturbed surfaces, walls, floors etc. all as directed by EIC |
| 43 | Taking down carefully byunscrewing from boards/outlets boxes, fitting and fixtures such as switches, sockets, ceiling rose, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc for resue at site or carrying to the store( To be measured only when found serviceable in all respects complete for reuse). |
| 44 | Tking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB\"s/MCB SP/SPN/TPN complete all as specified and directed by Engg-in-charge |
| 45 | M&L point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable 1100 Volts grade multistranded copper conductor drawn through in PVC casing and caping on underground stone / brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point / Exhuast Fan / Bell point controlled by one 5 Amps One way switch and making good surfaces all as specified and directed by Engineer-in-Charge. |
| 46 | All as per Item No. 04 but for one 3 pin 5/6 Amps switch socket outlet on sameboard |
| 47 | All as per Item No. 04 but for one 3 pin 5/6 Amps switch socket outlet on independent board |
| 48 | All as per item No.4 above but wiring with 4.0 Sq mm and 2.5 sqmmfor earth continuity for 3 pin 15/16 Amps switch socket combination |
| 49 | M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed. |
| 50 | M&L switch piano flush type single pole one way 15 Amps complete all as specified and directed. |
| 51 | M&L Switch Socket Combination outlet, multipurpose, 2 pin 5 amps/3 pin 5 amps controled by one switch 5 amps, flush type complete all as specified and directed. |
| 52 | M&L Universal socket outlet with shutter, 5/15 amps controlled by one switch 15 amps, flush type complete all as specified and directed. |
| 53 | S&F S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd all as specified and directed |
| 54 | M&L lamp holder insulated body with back plate suitable for battern fittings |
| 55 | supply and fix LED Lamp Retro fit type 9 watts 230 V and all as specified by Engr-in-charge |
| 56 | S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais all as specified |
| 57 | S&F Sheet Modular metal enclosure DB SPN 240 Volts 8 Way single door type with 200 Amps busbar for fixing of MCBs |
| 58 | S&F MCB SPN 40A amp rating 240V, 10KA \"C\" series fixing in DB\"s including connecting with bottle type copper thimble complete all as specfied and directed by Engr-in-Charge. |
| 59 | S&F MCB SP 6 to 32Aamp rating 240V, 10KA \"C\" series fixing in DB\"s including connecting with bottle type copper thimble complete all as specfied and directed by Engr-in-Charge. |
| 60 | Earthing complete with galvanized steelearth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead all as specified |
| 61 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 62 | S & F 20/25 Watt LED Bldg security light with a nominal system .The luminaire housing should be made of pressure die cast aluminimum.The total power consumption should not exceed20/25W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, including taking down old unserviceable fitting any type complete all asspecified and as directed. |
| 63 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 10 sqmm nominal crossectional in service connection. |