| 1 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil. |
| 2 | Rough excavation exc.1.5m deep and gatting out in hard/dense soil. |
| 3 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 deep and getting out in hard / dense soil |
| 4 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in soft/loose soil. |
| 5 | Returning filling in including spreading ,levelling ,watering and well ramming in layers not exc 25 cm thick as in hard/dense soil complete all specified and directed. |
| 6 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 7 | M&L for Hand packing (any thickness )at back filling with broken stone or boulders complete all as specified and directed. |
| 8 | Material and labour for providing cement concrete 1:2:4 type B-1 using 20 mm graded aggregate ) in plinth walls or retaining walls,drain walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) |
| 9 | M & L for PCC 1:3:6 type D-2 (using 40mm graded stone aggregate )as in foundation bed concrete complete all as specified and directed |
| 10 | M&L for cement concrete type D-2, 1:4:8in Cement concrete (40 mm graded aggregate ) in foundations, filling and mass concrete. |
| 11 | M&L for Cement concrete type B-2, 1:2:4 (using 40mm graded agg) as in surface channels and drains complete all as specified and directed. |
| 12 | M&L PCC 1:2:4 typeB-1 using 20mm graded stone aggregate as in coping. |
| 13 | M&L PCC 1:3:6 typeC-1 using 20mm graded stone aggregate as in bond stone etc |
| 14 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 15 | M&L for RCC Nominal Mix type B-1, 1:2:4 (using 20mm graded stone agg) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. |
| 16 | M&L for RCC Nominal Mix Type B-1, 1:2:4, (using 20mm graded stone agg) as in Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed. |
| 17 | M&L for RCC Nominal Mix Type B-1, 1:2:4, (using 20mm graded stone agg) as in Columns, pillars, piers, posts and struts complete all as specified and directed |
| 18 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc |
| 19 | Supply only of Liquid water proofing compound for exteenal plastering complete all as specified and directed |
| 20 | M&L for walling of random rubble uncoursed, well bonded,bedded and solidly hearted built in CM 1:6 complete all as specified and directed |
| 21 | Extra over stone walling for hammer dressing with maximum depression from straight edge held against the dressed surfaceto face beds and joints as specified of random rubble walling uncoursed or brought upto courses complete all specified and directed. |
| 22 | Use & Waste of flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed |
| 23 | Use & Waste of flatFormwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 24 | Use & Waste of flat Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed complete all as specified and directed |
| 25 | M& L for cleansawn Second class hard-wood scantlings with framed work. |
| 26 | Material & labour for 2nd class hardwood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area not exc. 3 sqcm complete all as specified and directed |
| 27 | S&F 30mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats. |
| 28 | S&F2nd class HW 30mm thick Glazed and skeleton shutters,divided into squared, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats. |
| 29 | S& F for 30mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats. |
| 30 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm widthtuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of lain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheetbeading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.complete all specified and directed |
| 31 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.complete all specified and directed |
| 32 | S&F 125 mm longaluminium anodized, barrel tower bolts extruded section. |
| 33 | S&F 125 mm size extruded aluminium alloy handles, fabricated type, anodised. handle fabricated type. |
| 34 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or Galvanised wire staples. |
| 35 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 36 | Mild steelTMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 37 | Ditto, itm no 36, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 38 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming toIS 1161- 1979 grade St.-240 |
| 39 | S&F 4mm Non Asbestos fibre cement bldg boards fixed or laid/inserted to GI/Aluminium framework with screws designer type as in false ceiling with & incl aluminium snap grid of size and fixed with hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia ,40mm long complete all as specified with allconnected accessories, fittings and fixtures complete all as specified and directed. |
| 40 | S & F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete, all as specified and directed. |
| 41 | S & F 0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 42 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified . |
| 43 | S&F offor Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 44 | Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed. |
| 45 | Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed. |
| 46 | M&L for 75mm thick Pcc type C-2, 1:3:6 (using 40mm graded stone agg) as in plinth protection complete all as specified and directed. |
| 47 | M&L for PCC 100mm thick, type D-2, 1:4:8 (using 40mm graded stone agg) infloors and pavings etc. complete all as specified and directed |
| 48 | Ditto as per item no 47 above but as in skirting or dado complete all as specified and directed |
| 49 | M&L for joint free Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floorsetcset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade . Note :- Colour and pattern will be decided by GE/Engr-in-charge. Contractor will bought the tiles only after approval ofcolour and pattern of tile by GE/Engr-in-charge. |
| 50 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removingserviceable tiles to store and rubbish off the premises |
| 51 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 complete all as specified. |
| 52 | M&L rendering 10 mm thick in CM 1:6on concrete inner surfaces of wallfinished even and smooth without using extra cement . |
| 53 | M&L rendering mixed with liquid wpc by 0.4% of cement weight 15mm thick in CM 1:4on concrete outer surfaces finished even and smooth without using extra cement . |
| 54 | M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:6 for laying floor tiles etc all as specified. |
| 55 | M&L for keyed pointing to random rubble masonry or brought upto course in cement mortar 1:3 complete all specified and directed. |
| 56 | Material and labour for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer all as specified. |
| 57 | M&L for preparation of new plastered surfaces of walland applying three coats of white wash complete all as specified |
| 58 | S & F sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 59 | Material and labour fornewplywood and wood based materialsurfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 60 | M&L for preparation of new steel Surfaces of any description over 10cm girth or width, and applying two coats of synthetic enamel paint overa coat of red oxide primer not otherwise described complete all specfied and directed |
| 61 | Material and labour for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 62 | S&F of 16 mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. |
| 63 | S&F of 20 mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. |
| 64 | S&F of PP-R Gate valves 20mm dia(brass insert) as per requirement of the site |
| 65 | S&F in Repair fancy type Bib taps 15mm size, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedcompleta all specified and directed |
| 66 | S&F in repairs fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore. |
| 67 | S&F in repairs stop valve, fancy type, chromium plated of brass with long shank and cup, concealed type, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of 15mm bore. |
| 68 | S&F waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including 32mm PVC waste pipe for WHB complete. |
| 69 | S&F PVC connection 15mm size with PTMT nuts, of 450mm length all as specified and directed. |
| 70 | S&F PVC (SWR) pipes 110mm dia single sockted in any length with rubber ring joints laid in trenches or floors. complate all specified and directed |
| 71 | S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints laid in trenches or floors.complate all specified and directed |
| 72 | S&Fof 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. |
| 73 | S&F PVC (SWR) bends any radius with access door, 110mm dia.complate all specified and directed |
| 74 | S&F PVC (SWR) bends any radius with access door, 75mm dia. complate all specified and directed |
| 75 | S&F PVC (SWR) junction single, (Single T) equal or unequal of dia110mm. complate all specified and directed |
| 76 | S&F PVC (SWR) floor trap, 75mm dia outlet, plain with grating incl Jointing with solvent cement. |
| 77 | M&L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 110 mm bore pipe complete all as specified and directed |
| 78 | S & F in repair Vitreous China Wash Down Water Closet Pan (Pedestal Pattern, white) excluding Fixing Boards, Flushing Cistern and Flush pipe all as specified and directed. |
| 79 | S & F in repair 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float, chain and pull and brackets etc complete. |
| 80 | S & F in repairsEWC seat Cover for Pedestral pan all as specified and directed. |
| 81 | S&F vitreous china wash hand basin in repairs white of size 550X400mm flat back excluding taps, waste, chain and plug but including brackets including cutting for and pinning in ends of brackets or erecting. |
| 82 | S&F 600 X 450mm bevelled edge looking mirror of selected quality glass , mounted on 6mm thickAC building board or commercial plywood including aluminium framing and fixed to wooden plugs with chromium plated brass screws and cup washers.complete all as specified and directed |
| 83 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground levelr all as specified and directed. |
| 84 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 85 | Dismantling Timber scantling with framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq cmin section , in any position all as specified and directed. |
| 86 | Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering complete all as specified and directed |
| 87 | Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed. |
| 88 | Use and waste flat form work to vertical faces of drain/retaining wall and similar work . |
| 89 | Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete, all as specified and directed. |
| 90 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) not exc 1.50 Sqm each including iron mongeries complete all as specified and directed. |
| 91 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed. |
| 92 | Supply & fix Aluminium anodisedbarrel tower bolt 100 mm long of extruded section etc complete all as specified and directed. |
| 93 | Supply & fix Aluminium anodisedbarrel tower bolt 150 mm long of extruded section etc complete all as specified and directed. |
| 94 | Supply & fix aluminium alloy, anodised, sliding door bolts 250mm size with hasp, staple (bolt type) and fixing clips of sheets , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy andfixed etc complete all as specified and directed. |
| 95 | Supply and fix MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed. |
| 96 | Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 100mm long complete all as specified and directed. |
| 97 | Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed. |
| 98 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 99 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories and PVC Boxes for fixing switches/sockets etc for the following:One light/fan point controlled by one No piano type switch5 Amps single pole one way |
| 100 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 101 | One socket outlet 5/3 pin 6 AMPS controlled by one switch onindependent board. |
| 102 | All as per item No 2 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor. |
| 103 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 104 | S&F Switch Piano Flush button single pole one way 15/16 Amp. |
| 105 | S&F socket outlet 2 in 1,3 pin & 2 pin, 5/6 Amp, 240 volt. |
| 106 | S&F socket outlet 2 in 1 ,3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. |
| 107 | S&F ceiling rose surfacebakelite 65mmx50mm 100watt three terminal. |
| 108 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) typeincluding taking down old Distribution Board and MCBs all as specified and directed . |
| 109 | S&F MCB SPN 40 Amps 240 volts \"C\" series, 10 KA, 50 Hz.Make:- As approved Make of DB |
| 110 | S&F MCB SP 5 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.Make:- As approved Make of DB |
| 111 | M&L for sub mainwiring with two single core PVC insulated of size 10 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including PVC Casing caping including 10.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly Including taking down old unserviceable sub main wiring and making good of existing surface.Note:-(i)One run of PVC Casing caping, two run of 10 sq mm copper conductor & one run of 10.0 sq mm copper conductor is measured as one unit. |
| 112 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including complete. |
| 113 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics including taking down old unserviceable light fitting any type complete with IP 65/66 protection complete. |
| 114 | Supplying and fixing 1100 volts grade 16 Sqmm heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular. |
| 115 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm diaby means of bolts, nuts, check nuts and washers ofgalvanizediron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduitgrouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed. |
| 116 | Supply and laying or fixing or passing through pipeXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 25 sqmm 2 core including taking out old unserviceable cable any type complete all as specified and directed by Engineer in charge. |
| 117 | High density polyethylene pipes (HDPE) 50 Sqmm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. |