Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-02-2026 | 2nd amendment in date | Date | 23-02-2026 |
| 2 | 29-01-2026 | 1st amendment in date | Date | 16-02-2026 |
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part I to XIII under Ser No. 1.00to 13.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. |
| 2 | Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch \"A\" Part I. |
| 3 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch \"A\" Part II |
| 4 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch \"A\" Part III |
| 5 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch \"A\" Part IV |
| 6 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch \"A\" Part V |
| 7 | Lump sum price worked out for AREA DRAINAGE as listed in Sch \"A\" Part VI |
| 8 | Lump sum price worked out for ROAD/ PATH as listed in Sch \"A\" Part VII |
| 9 | Lump sum price worked out for COMPOUND WALL/FENCING/GATE as listed in Sch \"A\" Part VIII |
| 10 | Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch \"A\" Part IX |
| 11 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch \"A\" Part X |
| 12 | Lump sum price worked out for DEMOLITION as listed in Sch \"A\" Part XI |
| 13 | Lump sum price worked out for RAIN SHED as listed in Sch \"A\" Part XII |
| 14 | Lump sum price worked out for HOT WATER SUPPLY as listed in Sch \"A\" Part XIII |
| 15 | SCHEDULE \"A\" PART - XIV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 16 | INTERNAL WATER SUPPLY |
| 17 | S & F two way bib cock with wall flange quarter turn (flow rate 6 Liter per minute) 15 mm dia. complete all as specified and directed |
| 18 | S & F Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed. |
| 19 | S & F Overhead Shower with arm (flow rate 6 Liter per minute) Single function Square overhead shower 150x150 mm Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 16 mm dia. complete all as specified and directed |
| 20 | INTERNAL ELECTRIC SUPPLY |
| 21 | S & F for wall mounted LED box type tube light fitting 4\" x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 22 | Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver and LED lamp 5700K Rated CCT energy efficientwith lumen efficiency corrosponding to five star BEE rating published for year of installation, pf 0.8, colour rendering index not less than 70%, IP20,with warranty option of 5 years from date of installation complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. |
| 23 | Supply and fixing forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. |
| 24 | Supply and fixingfor Decorative wall mounted luminaire made out of Nickle finish square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. |
| 25 | Supply and fixing LED 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,with warranty option of 5 years from date of installation complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. |
| 26 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for Bldg security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fittingwith warranty option of 5 years from date of installation including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 27 | S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. |
| 28 | S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). |
| 29 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). |
| 30 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). |
| 31 | Material and labour for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall be deposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. |
| 32 | DEMOLITION |
| 33 | Taking down existing old unserviceable point wiring of any type including switches, sockets, ceiling roses, fan regulators, light fittings complete all specified and as directed. |
| 34 | Taking down existing old unservicable Main Switches, DBs, meter box, Metal Clad sockets including MCB SP/SPNcomplete all specified and as directed. |
| 35 | Taking down existing old unservicable Main Sub Main wiring of any size/type complete all specified and as directed |
| 36 | Taking down existing old unservicable light fittings of any size/type complete all specified and as directed |
| 37 | Taking down existing Ceiling fan of any size and description from existing placeand deposited at AGE E/M store yard complete all specified and as directed. |
| 38 | Taking down existing Exhaust fan of any size and description from existing place and deposited at AGE E/M store yard complete all specified and as directed. |
| 39 | Taking down existing wall mounted fan of any size and description from existing place and deposited at AGE E/M store yard complete all specified and as directed. |
| 40 | Taking down existing Geyser of any size and description from existing place and deposited at AGE E/M store yard complete all specified and as directed. |
| 41 | Taking out old existing LT cable of any sizecomplete all specified and as directed. |
| 42 | Taking down existing old Tubes of GI pipe galvanised with all fittings of any grade laid in trenches having bore of any sizecomplete all specified and as directed. |
| 43 | Taking old unreinforced precast concrete cable cover of any class / any size complete all as specified and directed. |
| 44 | Taking out old existing LT Panelof any sizecomplete all specified and as directed. |
| 45 | Taking out old existing earthing of any type complete all specified and as directed. |
| 46 | Taking down GI pipe of 80/50mm size complete all as specified and directed |
| 47 | Taking down GI pipe of 40/25/20mm size complete all as specified and directed |
| 48 | Taking down Gate valve of any type of any size complete all as specified and directed |
| 49 | ROAD/PATH |
| 50 | M & L forPavement Quality Concrete (PQC) of minimum 28 days field flexural strength of 45Kg/Sqcm or 4.5Mpa, aggregate gradation as per Table 3 of IRC 15-2017, coarse aggregate of clean, hard strong, dense, non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular, virgin synthetic fibre of 12-18 mm length specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width, including curing and tining by Texturing cum Curing machine complete all as specified and directed. Required surface texturing to be done as specified in clause 10.1.14 and Table 9 of IRC 15-2017. |
| 51 | Notes:- (i) The admixture as per approved design mix shall be added and mixed.The cost of admixture required shall deemed to be included in the quoted rate. (ii) The Cost of polyester triangular non circular synthetic fibres as secondary reinforcement added and mixed in concrete shall deemed to be included in the quoted rate. (iii) Construction joints, dummy joints (contraction joints) and expansion joints shall be measured and paid separately under respective items.(iv) Deduction shall be made in PQC of quantity for expansion joints.(v) Trimming of vertical edges of construction joint (longitudinal and transverse) shall be carried out using sawing machine to maintain straight edge before laying of adjacent/ subsequent lane. The quoted rates shall be deemed to be inclusive of this provision and nothing extra shall be paid on this account.(vi) For the purpose of pricing this item, the cement content shall be considered as 360 kg/cum. However actual cement content shall be worked out as per design mix and nothing extra shall be paid on this account. (vii) Curing compound shall be applied at the paving stage after broom finish and surface is dry, and rate for spray of curing compound as per manufacturer instruction. The cost of curing compound and its application shall be deemed to beincluded in the quoted rate. (viii) The quoted rate shall be inclusive of use and waste of formwork for total thickness. (ix) At locations like link fillets, small areas etc where the slip form paver cannot be used for laying, fixed form paver with minimum 5m width can be used. |
| 52 | FENCING |
| 53 | Supply only PVC coated over Chain link MS galvanised fencing, of mesh size 50mmx50mm and weight not exc 4 Kg/Sqm complete all as specified and directed. Note : (i) Chain link of mesh size preferably 50mm x 50mm and weight not exc 4 Kg/Sqm will be provided, however the size may be changed after written approval of GE.(ii) The weight of chain link fencing shall be ascertained by BOO ordered by CWE(iii) Fixing of this item will be measured under respective schedule and Item. |
| 54 | EXTERNAL ELECTRIFICATION |
| 55 | M & L for boring under road with trench less tecnology forroad crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, for GI pipe light grade of size up to 100 mm dia of in any length any grade including for housing LT/ HT UG cables and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.Note :- GI protection pipe shall be measured and paid separately |
| 56 | Supply, Fabrication, Installation and Testing of LT Panel factory made, TypeTest Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,out door type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out 3.15mm thick CRCA sheet of suitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC /Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-. Note:-(i)Rate of earthwork and PCC work etc are deemed to be incl in this item.(ii)Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency.(ii)OEM design & GA drawingshall be submitted to GE for approval before start the manufacture(iii)Factory inspection for routine test/ type test as requiredshall be carried out by Rep of accepting officer before dispatch from factory. Testing charges shall be included in the quoted rates of item.(iv) Make ofFactory made TTA Panelshall be limited to : ABB/ SIEMENS/ SCHNEIDER/L&T/ C&S INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner shall not be accepted.) |
| 57 | IN COMING: (a)Copper strip busbar of 700 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 350 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No.OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 04 Nos (for Bldg supply)(b)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (for strret lights) (c)MCB TPN 32 Amps with breaking capaccity 10 KA - 02 Nos(d) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(e) Power contractor 4 Pole, 60 Amps,415 Volts, 50 Hz - 01 No (f)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. |
| 58 | Supply ,fabrication, installation and testing of LT Panel factory made, TypeTest Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, In door type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out 2mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with frontdouble door opening/ lockable by the key from both side and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & MCB out goingwith copper extension links inside for 12 Nos Energy meter single phase 2 wire 220 Volts, AC, fixing with two single core PVC copper conductor unsheathed wire multistandred 6 sqmm including one MCB SPN 32 Amp with connected acessories with glass window at front side to visualise meter reading without opening of doors accessories and mounted on DMC/ epoxy insulator including provison for termination with incoming and out going cables. Panel mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate). All extension link/interconnection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Block of 12 Qtrs)Note:-(i)Rate of earthwork and PCC work etc are deemed to be incl in this item.(ii)Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency.(ii)OEM design & GA drawingshall be submitted to GE for approval before start the manufacture(iii)Factory inspection for routine test/ type test as requiredshall be carried out by Rep of accepting officer before dispatch from factory. Testing charges shall be included in the quoted rates of item. |
| 59 | (iv) Make ofFactory made TTA Panelshall be limited to : ABB/ SIEMENS/ SCHNEIDER/L&T/ C&S INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner shall not be accepted.)IN COMING:- a)Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No.OUTGOING:- (a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed -12 Nos (for Each Qtr)(b) MCB, Single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed -02 Nos (for stair and parking shed) (c)Single phase smart prepaid meter including necessary electrical connections- 12 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter-01 No. |
| 60 | Supply ,fabrication, installation and testing of LT Panel factory made, TypeTest Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out 2mm thick CRCA sheet of suiitable size to accommodate accessories/ fittings with frontdouble door opening/ lockable by the key from both side and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & MCB out goingwith copper extension links inside for 06 Nos Energy meter single phase 2 wire 220 Volts, AC, fixing with two single core PVC copper conductor unsheathed wire multistandred 6 sqmm including one MCB SPN 32 Amp with connected acessories with glass window at front side to visualise meter reading without opening of doors accessories and mounted on DMC/ epoxy insulator including provison for termination with incoming and out going cables. Panel mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with ttwo coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate). All extension link/interconnection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Block of 06 Qtrs)Note:-(i)Rate of earthwork and PCC work etc are deemed to be incl in this item.(ii)Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency.(ii)OEM design & GA drawingshall be submitted to GE for approval before start the manufacture(iii)Factory inspection for routine test/ type test as requiredshall be carried out by Rep of accepting officer before dispatch from factory. Testing charges shall be included in the quoted rates of item. |
| 61 | (iv) Make ofFactory made TTA Panelshall be limited to : ABB/ SIEMENS/ SCHNEIDER/L&T/ C&S/LEGRAND/HENSAL INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner shall not be accepted.)IN COMING:a)Copper strip busbar of 150 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No.OUTGOING:- (a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed -06 Nos (for Each Qtr)(b) MCB, Single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed -02 Nos (for stair and parking shed) (c)Single phase smart prepaid meter including necessary electrical connections- 06 Nos (Cost of Smart meter cost will be paid seperately under respective item)(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter-01 No. |
| 62 | Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. (b) Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.(c) Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on display(d) The meter should support open communication protocol DLMSwith the softwareNote :-(i)It should run the meter in both prepaid and postpaid mode.(ii) The meters should carry 5 year warranty.(iii) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(iv) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters |
| 63 | Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. |
| 64 | M & L for Street light fitting bracket made out from GI Pipe 50 mm bore (dia), medium grade 1.50 metre long, bent to required shape and fixing to Poles with and including Clamp sets suitable for tubular pole made out of MS flat iron of size 40 mm x 6 mm thick, Nuts, Bolts as required duly painted with two coats of Aluminum Paint over a coat of Red Oxide Zinc Chrome Primer comlete all as specified and as directed.Note :- Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemd to be included in the quoted Unit Rate. |
| 65 | S & F for Security light junction box of size 205 x 255 x 112 mm for luminaries, weather proof made out of polycorbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole/ wall mounting type comprising of MCB SP 10 Amps,fixed on PCC foundation with screws complete all as specified and as directed. |
| 66 | M & L forStreet light control wire from junction box to street lightusing PVC sheathed multi stranded unstheathed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLSH (inner sheet) of sizetwo runs 2.5 Sqmm(Nominal Area) and one run of 1.50 Sqmm as earth wire drawn through heavy duty PVC rigid conduit ISI marked and its ISI marked accessaries completewith suitable size copper cable lugs and connector all complete as specified and directed |
| 67 | S & F for LED Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 protection security/ street light fitting luminaire of capacity 45 watts with high power LEDs as light source and electronic driver, 4 kV inbuilt and 10kV external surge protecton with efficiecny 120 lm/W Top opening driver cover for easy maintenance with warranty option of 5 years from date of installation with pre wired andnecessary mounting arrangements and provision of 4 sq mm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as directed by Engineer- in-charge. |
| 68 | EXTERNAL WATER SUPPLY |
| 69 | Material and Labour for cutting 150/80mm dia of pipe of any position for insertion TEE and including provision ofTEE branches etc complete all as specified and directed |
| 70 | Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 80cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation |
| 71 | SEWAGE TREATMENT PLANT |
| 72 | Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 50 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-C\"s Br Policy No 05/ 2023 dated 04 May 2023. |
| 73 | Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(i) Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Package STP tank inclusive of Solid Separation, Anoxic, Fixed Film MBBR Aeration & Final Sedimentation Zone Tank –1 of size -: 13000 mm (L) X 2430mm (Dia) complete.ii)Chop Whoop Winding Process based FRP Intermediate cum Treated Water Storage Tank 20 KL (With Partition) inclusive of two zones Tank –2 of size -: 5520 mm (L) X 2430mm (Dia)iii) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, Filter feed pump pipe of UPVC 50 mm Dia, Raw sewage pump pipe of UPVC 50 mm dia PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc.(iv)Installation, Supervision charges including plumbing & cabling material required during the installation :- Scope of work includes installation of 50 KLD FRP tank along with FRP Intermediate cum Treated Water Storage Tank of 20 KL capacity (With Partition) as per the drawing and size of the tanks along with the electro-mechanical items. The Tanks should be laid at an adequate depth below the sewage pipe at the site. The tanks shall be installed exactly as per the approved installation drawing issued by the FRP Tank manufacturer. (Excavation & Construction of 6 manhole chambers above the tank shall be paid extra thru other items). Rate to include installation as per manufacturer drawing complete job. Scope also includes providing and fixing of required no. of FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts as per the diameter & length of the tank as per installation requirement. Scope of work includes providing and fixing 2\" PVC Air vent nozzle as per requirement and manufacturer supplied Manhole covers. |
| 74 | Supply, Installation, Testing and Commissioning of cubical type Relay Based Control Panel of suitable size suitable for 415V, 3 Phase, 4Wire 50 Hz AC comprising of following specification:- (i). Panel encloser box with powder coting - 01 No(ii). Fan PVC Grill 4\"\" - 02 Nos(iii). Load Breack switch 32 Amps4 pole - 01 No(iv). MCB 6 AmpsDP \"C\" Curve -01 No(v). UV-OV Relay SM-501 -01 No(vi). MCB 6 Amps TP \"C\" curve- 05 Nos(vii). MCB 16 Amps TP \"C\"curve- 02 Nos(viii). ContractorLC1E09 - 07 Nos(ix). Over load Relay,LCRE 2.5- 4 Amps - 04 Nos(x). Over load relay, LCRE 1.6-2.5 Amps - 01 No(xi). Over load Relay,LCRE 7-10 Amps - 02 Nos(xii). Time switch - 02 Nos(xiii). Water level controller (LLC-101) - 02 Nos(xiv). 3- Position selector switch- 04 Nos(xv). 2- Position selector switch- 06 Nos(xvi). Element \"\"NO\"\"- 15 Nos(xvii). Red lamp 230 Volts,AC- 08 Nos(xviii). Green lamp 230 Volts, AC- 07 Nos(xix). Yellow lamp 230 Volts,AC 22.5 mm - 01 No(xx). Blue lamp 230 Volts AC, 22.5 mm- 01 No(xxi).Cable,Terminal, PVC Channel, Lock, Name Plate lugs set, Gland cable tie, Pedut, Printing sleeve, Yellow sticker, Harwareset, Scrach royal- 01 lot |
| 75 | Supply, Installation, Testing and Commissioning of TWIN LOBE BLOWERS rotary Air compressor capable of delivery 91 Cum/Hr suitable voulem of free air at 0.37 kg/sq.cm driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1500 RPM suitable for415 V, 3 Phase 50 Hz, Pressure guages-01 Nos,150 mm NRV -01 Nos,Butterfly shut off valve,air filter, cleaner etc. connection with suitable size from starter to air compressor assembly inclSupplying, laying, connectingof UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc.complete all as specified and directed.Note : (i). Capacity / Flow Rate: 91 m3/hr(ii).Discharge Pressure: 0.3 kg/cm2g (iii).Recommended Motor: 3 HP/1440 RPM (iv).Noise Level at 1.5 m distance: <65-68 (DBA) (v).MOC of Body rotter: EN19 with FG260 & FG-260(CI) (vi).Silencer: MS Fabricated |
| 76 | Supply, installation, commissioning and testing of non clog submersible sewage pump set of 1.0HP capacity and head 10 Mtr @ 9.0cum/hr suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable for operation at 415 Volts, Frequency 50Hz,3 Phase(For Sludge recycling in Solid Separation zone) for the following capacity. The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation incl Supplying, laying, connecting and testing of UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specifiedand directed. |
| 77 | Supply, installation, commissioning and testing of Pressure Sand Filter Capacity: 4.0 cum/hr, MOC: FRP, Filter Media: Pebbles & Filtering Sand, Piping: PVC – 1 No, Size: 24\"\" x 70\"\" (i)Pipe MOC: 50 mm Size (UPVC), Type: Side Mounted(ii).Max. W. Pressure: 10 PSI(ii).Multiport Valve: 01 nos (Manual), |
| 78 | Supply, installation, commissioning and testing of Activated Carbon Filter Capacity: 4.0 cum/hr, MOC: FRP, Filter Media: Activated Carbon 900 - 1200 I/V: PVC – 1 No. Size: 24\"\" x 70\"\".(i).Pipe MOC: 50 mm Size (UPVC), Type: Side Mounted(ii).Max. W. Pressure: 10 PSI(ii).Multiport Valve: 01 nos (Manual), complete all as specifiedand directed. |
| 79 | Supply, installation, commissioning and testing of Chlorine Dosing pump of capacity 0-6LPH of metering type ,MOC PTFE Diaphragm of 230V and Chlorine dosing drum of HDPE 50 Ltr capacitycomplete all as specifiedand directed. |
| 80 | Supply, installation, commissioning and testing of Filter feed pumpsset suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable for operation at 415V frequency 50Hz 3 ph(1W+1S) (For pumping into PSF & ACF Filters) for the following capacity. The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation.incl Supplying, laying, connecting and testing of UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified .Capacity / Flow Rate : 4.0 m3/hr Flow /50Hz Type of Pump: SubmersibleCapacity: 1.0 HP, Head: 10m |
| 81 | Supply, installation, commissioning and testing ofBar Screen (Mesh) of dimension 0.5m x 0.5m , MOC FRP (Pultruded), and Bas Spacing 10-12mm (coarse) complete all as specified . |
| 82 | Supply, installation, commissioning and testing of Non clog vertical submersible pumps (Flow and Head 700 LPM x40 Mtr Head), of capacity 10.0 HP with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain, cables, Earthing, testing complete with 2 years maintenance complete all as specified and directed |
| 83 | Supply, installation, commissioning and testing of monoblock, self priming, single stage, centrifugal volute type pump set having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, base plate, mounting channel frame, elastomeric insulation, accessories and fitting viz. mechanical seal pressure guage, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mountingand TEFC squirrel cage induction motor, suitable for operation on 3 Phase, 415 V +/- 10%, 50 Hz AC supply and having IE-3 efficiency and conforming to IS 12615:2018 of capacity 5 HPcomplete all as specified and directed. |
| 84 | Supply, Fabrication, Installation and Testing of LT Panel factory made, TypeTest Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,out door type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out 3.15mm thick CRCA sheet of suitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC /Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed incl the following accessories : |
| 85 | IN COMING: (a)Copper strip busbar of 60 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(b)On load change over switch TPN of capacity 63 Amps - 01 No(c) 4 Pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volt, lcs=100%lcu, 25 KA breaking capacity incl all fixing accessories with both ends spreader links - 01 No(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)(e) Digital Multifunctional meter, flush mounting type with CT\"s and selector switch - 01 set.OUTGOING:- (a)MCB SPN 5-32 Amps with breaking capaccity \"C\" curve 10 KA - 04 Nos(b) DOL starter single phase with suitable relay conforming to IS- 1347 (Part IV) suitable for 5 HP monoblock pump set, including, overload relay, auto timer & single phase preventer suitable range of digital ammeter with selector switch , voltmeter with selector indicating lamp (LED) & bakelite fuse showing RYB phase etc mounted on Ebonite sheet 10mm thick with flat strip frame of suitable size complete - 02 Nos(c) Fully Automatic star-delta strater with suitable relay range conforming to IS 1347 (Part IV) suitable for 10 KP Non clog submerssible pump set incl overload relay, auto timer & single phase preventer suitable range of digital amemeter with selector switch,voltmeter with selector indicating lamp (LED) & bakelite fuse showing RYB phase etc mounted on Ebonite sheet 10mm thick with flat strip frame of suitable size complete - 02 Nos |
| 86 | Supply & fixing ofSubmersible flat cable 4 sqmm 3 core multistranded copper conductor cable complete all as specified and directed. |
| 87 | Supply & fixing ductile iron Non return Sluice Valve of size 80 mm complete all as specified and directed. |
| 88 | Supply & fixingductile iron Foot Valve of size 80mmcomplete all as specified and directed. |
| 89 | Supply & fixing forductile iron CI Butter fly Valves of size 150mm bore complete incl nuts bolts washers butter gasketcomplete all as specified and directed. |
| 90 | Supply & fixing for for HDPE pipes PN 10 kg/ Sqmm, 150 mm dia laid in trenches and jointed complete with collars and all necessary fittings and fixtures complete all as specified and directed |
| 91 | Supply, laying, connecting and testing of 75mm dia UPVC pipes SCH 80 with and including all fittings such as bends elbows, tees, short pieces, connectors,check nuts,diminishing pieces,caps and plugs,unions, etc fixed laid in trenches including Suction and delivery pipe connection complete all as specified and directed . |
| 92 | Supply, laying, connecting and testing of 50mm dia UPVC pipes SCH 80 with and including all fittings such as bends elbows, tees, short pieces, connectors,check nuts,diminishing pieces,caps and plugs,unions, etc fixed laid in trenches including Suction and delivery pipe connection complete all as specified anddirected . |
| 93 | Supply, laying, connecting and testing of 32mm outer dia , 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabi lized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified anddirected . |
| 94 | Supply, laying, connecting and testing of 25mm outer dia , 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabi lized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed . |
| 95 | Supply and fixing UPVC Ball valve of 75mm dia complete all as specified and directed . |
| 96 | Supply and fixing UPVC Ball valve of 50mm dia complete all as specified and directed . |
| 97 | Supply and fixing PP-R Gate valve (brass inlet) of size 25mm outer dia complete all as specified and directed . |
| 98 | NOTE : Amount of credit of Rs.16,95,436.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 58 of tender documents in pdf form which will be deducted offline while acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail