| 1 | M&L for complete removal of existing treatment on old plastered surfaces of walls by filling cracks by crack fill paste of berger or of equivalent make as approved by GE, and Preparing of old plastered or unplastered surfaces by removing loose paints etc., removing nails etc and making good surfaces by applying 1.5 mm white birla/JK wall care putty wherever required , smoothen surfaces by sand paper and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces, of any height of Bldg. complete all as specified and directed. |
| 2 | M&L for preparation of old surfaces of walls by filling cracks by crack fill paste of berger or of equivalent make as approved by GE, removing loose paints etc., removing nails etc and making good surfaces by applying white birla/JK wall care putty wherever required , smoothen surfaces by sand paper and applying one coats of acrylic exterior emulsion paint of bldg upto any height of Bldg complete all as specified and directed. |
| 3 | -Ditto all as per item 02 here in before, but one coat on ceiling surfaces in any description complete all as specified and directed |
| 4 | M&L Preparation of old plastered or unplastered surfaces of wall including cornices, pillasters by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc applying one coats of oil bound distemper on old surfaces of walls all as specified and directed. |
| 5 | -Ditto all as per item 04 here in before, but one coat on ceiling surfaces in any description complete all as specified and directed |
| 6 | M&L for complete removal of existing treatment on walls, preparing surfaces and make surface free from loose particles oil stains etc. and surface ideally prewetted, applying white cementitious wall care fine putty average thickness1.50mmcomplete all as specified and as directed. |
| 7 | M&L for preparation of old plastered surfaces of wall or concrete surfaces and applying two coats of oil bound distemper over a coat of primer onon old surfaces of wallscomplete all as specified and directed. |
| 8 | M&L for preparation of old decorated plastered surfaces of wall and applyingone coat of plastic emulsion paint complete all as specified and as directed. |
| 9 | M&L for preparation of old plastered surfaces of wall/ceiling and applyingone coat of lustre paint complete all as specified and as directed. |
| 10 | M&L preparation of old steel surface in any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 11 | M&L for preparation of old wood or wood based surfaces in anu description and applying one coat of synthetic enamel paint all as specified and directed. |
| 12 | M&L for preparation on old wooden surface of any description, width or girth & filling crack by wood filler and applying one or more coats of french polish complete all as specified and as directed. |
| 13 | M&L for preparation of old plastered surfaces of wallsand applying one coats of cement base paint complete all as specified and as directed |
| 14 | M&L for complete removal of existing finishes of old plastered surfaces of wallsand applying two coats of cement base paint over acoat of primer complete all as specified and as directed |
| 15 | M&L for external stone masonary wall painting work (a) Cleaning of external stone masonary wall surfaces in any height byapplying one coat of sagatech SC solution (Saga polymers) or similar cleaning solution of Dr fixit/pidilte or other reputed brands as approved @ 3.0ltr/Sqm or as per manufacturer instructions.(b) After throughly cleaning the surface the loose masonary joints to be properly pointed with 1:3 cement sand mortar mixed with WPC.(c) Applying two coats of polymer modified cementitionus coatcomplete all as specified in manufacure instruction and directed. |
| 16 | M&L for one coat of exterior grade emulsion roof paint over Mangalore tiles by mechanical sprayer upto 15 mtr, cleaning the roof by speed water jet all as specified and directed. (Note:- Pianting will be done by using mechanical hydraulically operated crane of adequate height with all safety measures so that there will be no climbing on roof top). |
| 17 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50sqm in each pane incl hacking out existing broken glass in any height of bldg complete all as specified and directed. |
| 18 | -Ditto- all as per item No 17 here in before but frosted glass |
| 19 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc in any height of Bldg complete all as specified and as directed |
| 20 | M&L for 15mm thick cement rendering in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cementin any height of Bldg complete all as specified and directed. |
| 21 | M&L for 15mm thick cement plaster in CM 1:6 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cementin any height of Bldg complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of wallsand applying two coats of cement base paint over a coat of primer complete all as specified and as directed |
| 23 | M&L for preparation of new plastered surfaces of wallsand applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed |
| 24 | M&L for preparation of old wooden surface of any description, width or girth including cleaning and preparing the surfaces with a coat of wood filler and applying one or more coats of malamine polish till the desired finish is obtained complete all as specified and directed by Engr-in-Charge |
| 25 | Writing letters for figures (Block, Roman, Italic or Indian) n.exc 30cm high complete all specified and directed |
| 26 | Removing of vegetation / plantation on the wall/ roof/ any position of up to double storey building including necessary scaffolding and roots, girth n. exc. 10cm eachand applying chemical treatment with GLYPHOSATE 41% and making good of surface including removing /refixing of CI/GI pipe lines complete all as specified and as directed. (Note : Brick work, plaster and CI/GI pipe lines shall be measured and paid separately) |
| 27 | S&F in repairs 110mm bore PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls complete all as specified.. |
| 28 | S&F in repairs 75mm bore PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls complete all as specified.. |
| 29 | S&F in repairs PVC (SWR) bends of any radius of 110mm bore complete all as specified.. |
| 30 | S&F in repairs PVC (SWR) bends of any radius of 75mm bore complete all as specified.. |
| 31 | S&F in repairs PVC (SWR) branch piece single (single ‘Y’) equal or unequal for 110mm bore PVC pipe complete all as specified.. |
| 32 | S&F in repair PVC(SWR) branch piece single (single ‘Y’) equal or unequal for 75mm bore PVC pipe complete all as specified.. |
| 33 | S&F in repair for PVC (SWR) junction single (single ‘T’) equal or unequal with access door for 110mm bore pipe complete all as specified.. |
| 34 | S&F in repairfor PVC (SWR) junction single (single ‘T’) equal or unequal with access door for 75mm bore pipe complete all as specified.. |
| 35 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. |