| 1 | Sch \"A\" |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing, serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 0.11 Sqm but n.exc 0.18 Sqm in neatcement slurry and pointed in white or coloured cementwith pigment to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 4 | M&L glazed ceramic coloured tiles 450mm x 300mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. |
| 5 | M&L vitrified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tilesexceeding 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick bedding layer in cement mortar (1:6). complete all as specified and directed. |
| 6 | All as per item No 04 above but over and including 10 mm thick rendering in 1:4 cement mortar complete all as specified and directed. |
| 7 | Taking down chowkats or frames (without taking off shutters from the frame) area n.exc 1.5 Sqm each complete all as specified and directed. |
| 8 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colourPVC sheet reinforced with MS square tube suppling & fixing in opening as per specification and drawing complete all as specified and directed. |
| 9 | S&F factory made soilid panel PVC Door shutter 30mm thick (Style) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC \"C\" channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 10 | S&F Anodised aluminium power coatedwindow and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, including necessary aluminium fittings complete all as specified and directed. |
| 11 | Taking down chowkhat or frame exc. 1.5 sqm but n.exc 4 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 12 | S&F Anodised aluminium powder coated frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 13 | S&F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each Shutter, hinges, anodised aluminium snap beading, including necessary aluminium builders hardware, screws etc. complete all as specified and directed. |
| 14 | S&F Sheet glass frosted type 5.5mm thick, selected quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 15 | S&F Sheet glass frosted type 5.5mm ,selected quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 16 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 17 | Taking down cement plaster of any description, any heightincluding raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 18 | M&L rendering 12mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L on newly plastered surface of walls applyingtwo coats of oil bound distemper over a one coat of primer over 3mm wall care putty and complete all as specified and directed. |
| 20 | M&L three coats white wash on wall surfaces inclduing prepration of newly plasteredand undecorated surfaces complete all as specified and directed. |
| 21 | M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L prepration of newly plastered or pointed surface of walls and applying two coat of cement base paint complete all as specified and directed. |
| 23 | M&L rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling complete all as specified and directed. |
| 24 | M&L preparation of newly plastered or pointed surface of wall and applying three coats of white wash on ceiling complete all as specified and directed. |
| 25 | S&F in repairs vitreous china wash hand basin white flat, backof size 550mm x 400mm, including waste coupling , waste pipe and pedestal complete all as specified and directed . |
| 26 | S&F in repairs vitreous china wash downwater closetpedestal pattern pan whitewithtrap including connection to existing out joint pipe, flushing pipeor Cistern, antisyphonage pipe, including making, etc complete including making goood to flooretc complete all as specified and directed. |
| 27 | S&F in repairs plastic water closet seat cover of White colourclosed pattern with flat bottom and cover with mild steel chromium plated hinging device etc complete as specified and directed. |
| 28 | S&F in repairs health faucet (ABS Body) mild steel cromium plated suitable for 15 mm dia pipe 1.25 metre lomg flexible tube and ABS wall hook including making connections and fixed in position etc complete all as specified and directed. |
| 29 | S&F in repairs PVC low level flushing cisternsyphonic action typewhitewith inlet ball valve, handle including brackets10 ltrscapacityincluding flush pipe etc complete all as specified and directed. |
| 30 | S&F in repairs PVC connections 15mm size with PTMT nuts and bolts of length 450mm etc complete all as specified and directed |
| 31 | S&F in repairs Bib taps,chromium plated cast copper alloy with crutch or butterfly handle fancy type, screwed down , screwed for iron pipe or for brass ferrule and fixed in iron pipe of 15 mm complete all as specified and directed. |
| 32 | S&F in repairs stop valves/angle valve 15mm bore , cast copper alloy fancy type, chromium plated ,screwed down high pressure with crutch or butterfly handlescrewed both ends for iron pipe or for unions and fixed etc complete all as specified and directed. |
| 33 | M&L for Dubbing out in cement plaster (1:4) of average 10mm thick on irregular face of walls complete all as specified and directed. |
| 34 | S&F in repairs Brass CP mixer (wall mixer/ basin mixer/ sink mixer)for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 35 | S&F in repairs stop valves/angle valve 15mm bore chromium plated , cast copper alloy fancy type, screwed down high pressure with crutch or butterfly handlescrewed both ends for iron pipe or for unions and fixed (concealed type) etc complete all as specified and directed. |
| 36 | S&F in repairs stainless steel sinks 1 mm thick sheet with over all size 495mm x 420mmand bowl size 410mmx330x160mm for kitchen or laboratory with pluge washers and waste, including waste coupling , waste pipebedding in cement mortar on to dwarf walls or including fixing centilever bracket and connecting uinon to waste pipe complete all as specified and directed. |
| 37 | S&F in repairs chromium platedshower roses with or without swivel joints 125 mm size including fixing to steel pipe complete all as specified and directed. |
| 38 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia D-type, 60cm long between flange complete all as specified and directed. |
| 39 | S&F Soap dish, any type, fixed to plugs with chromium plated brass screws in repair complete all as specified and directed. |
| 40 | S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and directed. |
| 41 | All as per item No 39 above but 20mm bore complete all as specified and directed. |
| 42 | Taking down & Re-fixing old steel tubing and connections in new or old postion (wall, ceiling , floors ,etc) 15mm bore complete all as specified and directed. |
| 43 | Taking down & Re-fixing old steel tubing and connections in new or old postion (wall, ceiling , floors ,etc) 20mm bore complete all as specified and directed. |
| 44 | S&Frotational moulded polythylene water storage tanks triple layered of capacity 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position including nipple suitable for water tank including taking down existing and S&F in repairs ballBrass valves high pressure with polythylene float and flynut complete, screwed for iron pipe or brass ferrule and fixed 20mm dia complete all as specified and directed. |
| 45 | S&F in repairs stop valves 20mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle etc complete fixedcomplete all as specified and directed. |
| 46 | Demolition of reinforcement cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (reinforcement cut as reqd to facilitate demolition) complete all as specified and directed. |
| 47 | M&L reinforced Cement Concrete type B1, 1:1.5:3(nominal mix ) (using 20 mm gradedstone aggregate) in slab supported on wall complete all as specified and directed. |
| 48 | M&L for Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc complete all as specified and directed. |
| 49 | M&L for Form work to edges of concrete floor and roofs and similar work exceeding 5 cm but not exceeding 10 cm wide complete all as specified and directed. |
| 50 | M&L for TMTbars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoopingfor columns , hooking ends and binding with and including mild steel wire as in straightening bars( annelaed) not less than 0.9 mmd ia or securing with clips complete all as specified and directed. |
| 51 | M&L Granite slab 18- 20 mm thick (table rubbed and polished) as inin steps, jambs,pillars, window-cill, cooking platform over and including 15mm thick bedding layer in cement mortar (1:4)inandpointed with white or colour cement(1:2) using marble dust with admixture to match the shade of granite complete all as specified and directed. |
| 52 | S&F 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors including taking down existing complete all as specified and directed. |
| 53 | S&F 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints fixed to wall including taking down existing complete all as specified and directed. |
| 54 | S&F 75 mmPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including taking down existing complete all as specified and directed. |
| 55 | S&F 75 mmPVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall including taking down existing complete all as specified and directed. |
| 56 | S&F PVC (SWR) 75mm dia bend of any radius complete all as specified and directed. |
| 57 | S&F PVC (SWR) 110mm dia bend of any radius complete all as specified and directed. |
| 58 | S&F 75mm SWR vent cowls complete all as specified and directed. |
| 59 | S&F 110 mm SWR vent cowls complete all as specified and directed. |
| 60 | S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 61 | S&F PVC P-Traps for water closets of 110mm bore complete all as specified and directed. |
| 62 | Dismantling brick tiles or terracing tiles, single layers including any treatment on roof complete all as specified and directed. |
| 63 | Demolition mud phuska in roofs any thickness incl platering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. |
| 64 | M&L for priming surfaces and applying normal treatment (for moderate conditions) using bitumen primer @.30 Kg/Sqm applied hot complete all as specified and directed. |
| 65 | M&L rendering 10mm thick on roof surfacein cement mortar (1:3) mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directed. (Note : Supply only of water proofing compound shall be measured and paid for separately under appropriate item of this Schedule). |
| 66 | M&L providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150gms/Sqm) laid on primed surfaces by torched applicationincluding applying evenly a bitumen tack coat of industrial bitumen 85/25 @ 1.2 kgs/Sqm incl cleaning surfaces complete all as specified and directed. |
| 67 | M&L forPlain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate average thickness 50mm as in roof padding including mixing water proofing compoundcomplete all as specified and directed. Note : Water proofing liquid shall be measured and paid seperately) |
| 68 | M&L 40 mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar ( 1:3 ) mixed with 5% of crude oil by weight of cement on cement mortar complete all as specified and directed. |
| 69 | M&L 40 mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar ( 1:3 ) mixed with 5% of crude oil by weight of cement on cement mortar complete all as specified and directed but except tile including removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and directed. |
| 70 | Supply only Integral water proofing compound (ISI marked) complete all as specified and directed. |
| 71 | Removing material of mud phuska exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 72 | M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 73 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 74 | M&L rendering 15mm thick on walls as well as on sunken floor in cement mortar (1:3) mixed with water proofing compound finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge. (Supply only of water proofing compound shall be measured and paid for separately under appropriate item of this Schedule). |
| 75 | M&L forcement concrete 1:5:10type E-2 (using 40 mm graded crushed stone aggregate)as in foundation filling and massconcrete complete all as specified and directed. |
| 76 | Demolition of brickwork built in cement or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 77 | M&L brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in cm 1:6 complete all as specified and directed. |
| 78 | All as per item No 76 above but except bricks complete all as specified and directed. |
| 79 | S&F in repairs 25 mm dia fancy type mild steel, chromium plated curtain rod fixed in position with fixing brackets , stops, rollers, etc. complete all as specified and directed. |
| 80 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level) complete all as specified and directed. |
| 81 | M&L Endura ceramic tiles of size 300mmx300mmx10mm thick laid in floors etc., set and jointed in neat cement slurry and pointed in grey or coloured cement and pigmentto match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement complete all as specified and directed. |
| 82 | M&L 50 mm thick PCC 1:3:6mix type C2 as in plinth protection and paving finishing cone surface even and smooth without using extra cement complete all as specified and directed. |
| 83 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 84 | M&L for machine cut kota stone slab flooring 20-25 mm thick laid over and including screed bed 15 mm thick in CM (1:6) and jointed with greay cement slurry mixed with pigment to match the shade of slab including cutting, rubbing and polishing complete all as specified and directed. |
| 85 | All as per item No 83 above but in one piece as in riser ,treads of of stair, skirting/dado laid over and inlcuding 10mm thick cement screed in CM 1:4 complete all as specified and directed. |
| 86 | M&L one coatof syntheticenamal paint to steel surfaces of any discription over 10 cm width or girth not otherwise described includingpreparation of old surface complete all as specified and directed. |
| 87 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling insoft and loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 88 | M&L cementconcrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foundation filling of posts & struts including form work complete all as specified and directed. |
| 89 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 |
| 90 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 91 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 92 | M&L two coats of synthetic enamel paint to untreated surfaces of steel over 10cm width or girth not otherwise described over a coat of red oxide primer after preparation complete all as specified and directed. |
| 93 | S&F in repairs PVC bathroom cabinet mirror size 350mm x 450mm complete all as specified and directed. |
| 94 | S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 95 | Supply & fixing in repairsGlass self assembly with stainless steel frame Corner glass shelf etc complete all as specified & directed . |
| 96 | Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. complete all as specified & directed. |
| 97 | Taking down Ceiling Fan/Exthaust fan, sealing cable end, dismantling blades from fan and keeping in safe custodyfor reuse at site andmaking good disturbed surfaces complete all as specified and directed. |
| 98 | Refixingonly ceilingfan and connecting up including provision sutiable of new down rod for ceiling fans,of cable from celling rose/ connector to fan including painting & minor repairs complete all as specified and directed. |
| 99 | Refixingonly exhaustfan and connecting up including provision of cable from celling rose/ connector to fan including painting & Minor reapir complete all as specified and directed. |
| 100 | M&L for making hole using core drill suitable for exhaust fan as per direction and making good to all disturbed surfaces and matching the same with adjoining specifications complete all as specified and directed. |
| 101 | M&LPoint wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealedin walls(on surface in ceiling/beam etc.) including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor all as specified and as directed for the following :- |
| 102 | One light/fan/call bell point controlled by one, one way switch |
| 103 | Oneswitch socket outlet point 5 Amps on independent board |
| 104 | One 3 Pin socket outlet , 5 Amps on the same board with other switch |
| 105 | All as per item No. 100 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed. |
| 106 | Supply and fix wall decorative LED light fittings 10watt higher energy saving decorative LED lighting fixture enviromental friendly, energy efficient complete all as specified and directed. |
| 107 | S&F 20 watt LED tube lighting fixture complete all as specified and directed. |
| 108 | S&F 10 watt LED tube lighting fixturecomplete all as specified and directed. |
| 109 | M&L Sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through new PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. |
| 110 | M&L Sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through Existing or new PVC rigid non metallic conduit including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation complete all as specified and directed. |
| 111 | Supply and fix sheet metal enclosure with socket plug top and MCB SPN 20 Amp with enclosure with a two pin and earth plug and socketcomplete all as specified and directed. |
| 112 | Supply and fixTPN MCB DB 4 ways ,Double door with 415 Amps, Double door type complete all as specified and directed. |
| 113 | Supply and fix MCB TPN 63 Amp, 415 Volt , C- series, 50 Hz, breaking capacity-10 kA complete all as specified and directed. |
| 114 | Supply and fixfor SPN MCB DB 8 wayswith Volt, Double door type complete all as specified and directed. |
| 115 | Supply and fix forMCB SPN 40 Amps, C-series complete all as specified and directed. |
| 116 | Supply and fix for SP MCB 6-32 Amps C-series complete all as specified and directed. |
| 117 | Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed. |
| 118 | S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and directed. |
| 119 | S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and directed. |
| 120 | S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 121 | S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 122 | S&F Modular White cover plate with frame,12 module complete all as specified and directed. |
| 123 | S&F Modular White cover plate with frame,4 module complete all as specified and directed. |
| 124 | S&F Modular White cover plate with frame,2 module complete all as specified and directed. |
| 125 | S&F Modular Metal flush box 12 module complete all as specified and directed. |
| 126 | S&F Modular Metal flush box 4 module complete all as specified and directed. |
| 127 | S&F Modular Metal flush box 2 module complete all as specified and directed. |
| 128 | S&Fbell push single pole , AC, 230 Volts, single pole complete all as specified and directed. |
| 129 | Supply and fix fan step regulator, 120W, 1 module complete all as specified and directed. |
| 130 | S&F Calling bell, AC, 230 Volts, single pole complete all as specified and directed. |
| 131 | Taking down electric water heater Geyser with its accessories and keeping in safe custodyfor reuse at site andmaking good disturbed surface. Refixing the same after Painting & minor repair if any at the location as directed and connecting up including all its accessories such as safety valve,thermostat,NRV ,supply and fixing of GI pipes of dia 20mmlaying in wall making serviceable after fixing as specified and directed. |
| 132 | Supply and fixingbldg security light fitting LED 35 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, oprating range- 90V to 340V AC. , IP66 with high power LED lampcompete all as specified and directed. |
| 133 | M&L Earthing including earth work complete with galvanised steel earth plate electrode60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. |