| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-01-2026 | AMDT01 | BOQ | 24-01-2026 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches in n.exc 1.5 M wide and n.exc 1.5 m depth soft/loose soil for foundations, laying pipes, drains or manholes etc, n. exc. 10 sqm on plan and n. exc. 1.5 m depth, and getting out including trimmings sides and forming bottom surfaces to required level/slope etc, complete all as specified and directed. |
| 2 | M & L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations, filling & mass concrete complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified. |
| 4 | Removing excavated material, n. exc 50M and depositing where directed at a livel n. exc 1.5M above the starting pointat the description of contractor complete all as specified and directed. |
| 5 | M & L reinforcement cement concrete, TypeM-25 (20 mm graded stone aggt) as in foundations, footing, plinth beams basis of columns, etc complete all as specified and directed. |
| 6 | M & L reinforcement cement concrete, TypeM-25 (20 mm graded stone aggt) as in columns,pillars posts, & the like etc complete all as specified and directed. |
| 7 | M & L reinforcement cement concrete, TypeM-25 (20 mm graded stone aggt) as in beams, bands, archs, flat, curved, noising, cornices in step manners as directed& the like complete all as specified and directed. |
| 8 | M & L for reinforced cement concrete TypeM-25(using 20 mm graded stone aggregate) as in slab supported on walls or beams complete all as specified and directed. |
| 9 | M & L for reinforced cement concrete TypeM-25(using 20 mm graded granite stone aggregate) as in Chajjas complete all as specified and directed. |
| 10 | M & L formwork to sides of concrete foundations, footings bases of columns,plinth beams etc complete all as specified and directed. |
| 11 | M & L formwork to sides of pillars, posts, columns etc complete all as specified and directed. |
| 12 | M & L formwork to sides & soffits of beams, bands, archs, flat, curved, noising, cornices in step manners as directed& the like of concrete complete all as specified and directed. |
| 13 | Form work to soffits of suspended slabs and similar works not exc. 200mm thicksurfaces of concrete complete all as specified and directed. |
| 14 | Formwork to chullah hoods, chajjas,troughs and similar items including edges for fair finished surfaces of concrete complete all as specified and directed. |
| 15 | Form work to edges of concrete flats,sides of RCC/PCC bands & similar works, not exc. 20cm wide of concrete complete all as specified and directed. |
| 16 | S & F mild steel TMT bars 10 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 17 | S & F mild steel TMT bars 6 to 8 mmdia & over, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 18 | S & F mild steel TMT bars 5 mmdia & over upto 10 mm as in stirrups, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 19 | M & L brick work sub class \"B\" bricks(OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 20 | M & L brick work sub class \"B\" bricks , (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 21 | M & L for 40 mm thick DPC to horizontal or vertical surfaces including necessary form work PCC (1:2:4) type B-0using WPC @ 3 % of cement by weight complete all as specified and directed.Note: Integral WPCshould be measured and paid separately. |
| 22 | M & L rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed. |
| 23 | M & L for rendering 15mm thick in cement mortar (1:4) on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound complete all as specified and directed.Note: Water proof compound paid seperatly. |
| 24 | M & L rendering 5mm thick in cement mortar (1:3) on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 25 | M & L for preparation of new plastered surfaces of walls apply two or more coats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationincluding priming coat a primer applied @ 0.90 litre/ 10 sqmon the surface at any height incuding necessary scaffolding complete all as specified and directed.. Note: Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make:Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/Berger(10 years product warranty) at any height incuding necessary scaffolding. |
| 26 | M & L for preparation of new plastered/complete removal of existing surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed at any height incuding necessary scaffolding over new/complete removal surfaces complete all as specified and directed.Note: (i) Primer and emulsion application to be carried out through air less spray machine (Only mechanical application allowed except in paint application on bands/chajja/building edges/borders/projections where contrasting color as specified and directed is to be applied). (ii) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paintapplication).Make: Nerolac Excel Top guard (10 years product warranty)/ Asian Paints Ultima Protek (10 years product warranty)/ Berger weather coat long life 10 (10 years product warranty) at any height incuding necessary scaffolding. |
| 27 | M & L for preparation of new plastered on surfaces of Ceiling apply distempering 2 or more coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmshould be able to spray in hard to reach areas and penetration of distemper on the surface at any height incuding necessary scaffolding complete all as specified and directed. Note: Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make:Asian Paints Royal(10 years product warranty) orNerolac(10 years product warranty)/ Asian Paints Royal(10 years product warranty)/ Berger(10 years product warranty) at any height incuding necessary scaffolding. |
| 28 | M & L for exterior or interior waterproof/weather proof cement based3 mm thick putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the new plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:-Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. |
| 29 | M & L 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides compete all as specified and directed. |
| 30 | M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floors/wallsin PCC (1:2:4) type B-0 to match the existing floors/walls complete all as specified and directed. |
| 31 | M & L brick work with fly ash brick (As per IS-13757-1993) brunt clay fly ash building bricks(old size brick) straight or curved on plan exe 6 mtr mean radius buit in cement motar (1:6) complete all as specified and directed. |
| 32 | M & L forclamps, hold fasts; wall ties, plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts plate washers and similar small articles conforming to Fe-290 Gde-E-165 ® complete all as specified and directed. |
| 33 | M & L for preparing ofnew or previouslyuntreated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer complete all as specified and directed. |
| 34 | M & L for painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zincchromic primer including preparation of surfaces complete all as specified and directed. |
| 35 | M & L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 36 | S & F stainless steelhinges 100mm long medium weightto pressed steel/angle iron frames by welding/screws complete all as specified and directed. |
| 37 | S & F aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed complete all as specified and directed. |
| 38 | S & F 300mm Aluminium alloy, anodised, sliding door bolt with hasp ,staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 39 | S & F anodized aluminium frame with power coating (minimumthickness 50 micron) and other sections for doors, windows, ventilators, partitions,with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 40 | S & F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m,with power coating (minimumthickness 50 micron)including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified and directed. |
| 41 | Supply only 5mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each panecomplete all as specified and directed. |
| 42 | S & F toughened glass of thickness 12mm as in hinged doors, partitions, automatic doors and similar works including cutting to shape, drilling holes as required complete all as specified and directed. |
| 43 | Supply only 5mm thick Froasted glass in squares n exc 0.5 sq. m each pane complete all as specified and directed. |
| 44 | Supply only5mm thickTinted Coloured glass fixed to metal frame complete all as specified and directed. |
| 45 | S & F in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty,fixed in repair with & including replacement of floor tiles if any broken during repair work and making good disturbed surfaces matching to the exixting surfaces complete all as specified and directed. |
| 46 | S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples & screwed complete all as specified and directed. |
| 47 | S & F anodized aluminium grill with power coating (minimumthickness 50 micron) of approved pattern and fixed to the existing window/ventilatorframe with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening sizefor fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete all as specified and directed. |
| 48 | M & L for 25 thick cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in levelling coarse for tiles complete all as specified and directed. |
| 49 | M & Lfor 100 mm thick PCC (1:4:8) type D -2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 50 | M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl 15mm thick screed bed/bedding layers in cement mortar (1:4) complete all as specified and directed. |
| 51 | M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 52 | M & L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as inplinth protection surface finished fair and even complete all as specified and directed. Note:Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. |
| 53 | M & L screed laid 10mm thick in cement mortar (1:4 ) with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 54 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 55 | M & L for roof treatment using APP based polymeric membrane minimum weighing not less than 3kg/sqm black finish reinforced with non woven polyster matt with thermo finish (wt. not less than 150 gms/sqm) laid over compatible bitumen primer @0 .30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including applying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separate payment will be made and measurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0 .1 liter per Sqm on topof treated surface of roof complete all as specified and directed. |
| 56 | M & L for providing cement concrete intype B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to(consolidated thickness 65mm or less) as leveling course, laid and compacted inmin slope 1:30 over roof complete all as specified and directed. |
| 57 | M & L for false ceiling made out of E-board classic of size 595 x 595 x 4 mm thick, (as approved by GE) fixed with existing frame work fixing the board to frame complete all as per manufacurers instructions complete all as specified and directed. |
| 58 | M & L for GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 3 mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/ccomplete all as specified and directed. |
| 59 | M & L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 60 | M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 61 | M & L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings.converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed. |
| 62 | M & L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed. |
| 63 | Excavation in post holes each not exc 0.5 cum, getting out soft/loose soil , returning, filling in and ramming earth or broken rubble mixed with earth aroundin layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 64 | M & L for double charged vitrified ceramic tiles 8mm to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed. |
| 65 | M & L for double charged vitrified ceramic tiles8 to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed. |
| 66 | M & L Glazed ceramic coloured tiles in vertical surface450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cement mortar (1:4) complete all as specified and directed. |
| 67 | M & L forGranite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completeincl 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed. |
| 68 | M&L for point wiring in stove enamelled steel conduit not less than 20 mm dia complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade with including modular type PVC rectangular block of suitable size and plate and frame of modular type including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etccomplete all as specified and as directed for the followings complete all as specified and directed.:-One light / fan point controlled by one way switch |
| 69 | All as per Item No 68.00 here-in-above but for One 5 Amp socket outleton independent board complete all as specified and directed. |
| 70 | All as per above Item No 68.00 here-in-before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 71 | S & F ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and directed. |
| 72 | S & F socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 73 | S & Fswitch 6 amps modular type one one way complete all as specified and directed. |
| 74 | S & Fswitch 16 amps modular type one one way complete all as specified and directed. |
| 75 | S & F socket outlet 6A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 76 | S &F LED type flood light 35 watt 230 volts AC outdoor type withIP 65 classprotection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range140v to 270 V, totallumen efficiency =80 lm/watt , THD≤20 CRI>80, colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. |
| 77 | S & F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and directed.Note: (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same. |
| 78 | S & F MCB SP 5 to 40 Amps,240 volts curve \"B\",breaking capacity 10KA, complete all as specified and directed. |
| 79 | S & FMCB DP16 to 40 Amps,240 volts,curve \"B\", breaking capacity 10 KA, complete all as specified and directed. |
| 80 | S & F Earthing to DBs with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. |
| 81 | S & F wall mounted Air circulator 600 mm sweep including copper wound motor ,metallic body , 50 Hz , 240 voltincluding all fixing/welding accessories complete all as specified and directed. |
| 82 | M & L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including allflame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable withstranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed. |
| 83 | S & F flame proof/weather proof direct entry typerotary switch singlepole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc complete all as specified and directed. |
| 84 | S & F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad.(b) Original Test certificate of Manufacturer shall be produced by Contractor. |
| 85 | S & F flame proof exhafust fan380 mm sweep, 230 Volt, Single phaseincluding grounting Nuts, bolts and making electrical connections flame proof Conduit, including making of suitable size hole in wall/aluminium/wooden window & making good to disturbed surfaces as per matching to existing with louvers complete all as specified and directed.Make : Flexpro/Sudhir/Baliga/Shyam. |
| 86 | Supply install testing and commissioning of flame proof totally enclosed SPN DB 8 way complete with CMRI certified and flame proof, whether proof complete with emergency off switch with LED indicator as per incoming and out going circuit.Incoiming :(a) Flame proof MCB SPN 32 Amps 2 pole complete with 10 KA breaking capacity and B Curve -01 Nos.Out going : (a) Flame proofMCB SP 6 Amps complete with 10 KA breaking capacity and C Curve -10 Nos.Make : Flexpro/Sudhir/Baliga/Shyam. |
| 87 | Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power UG cable with stranded aluminium conductor 1100 V gradeof size 35 sqmm 3.5 core complete all as specified and directed. |
| 88 | M & L forfilling dry sand river cushioning for under ground cables complete all as specified and as directed by the Engr-in-Charge.Note : For the Measurentpurpose only punned thicknes shall be measured & paid. |
| 89 | M & L for common burnt clay building bricks sub-class \"B\" designation of size 230X115X75mm complete all as specified and directed. |
| 90 | Cutting existing road/hardstand of any type by using crow bar chisel uprto adepthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 91 | M & L in replacement for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of eath plate not less than 1.5mtr belowground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C 1 using 20mm raded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinformed with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer nuetral/body/ LT panel etc. and tesing on completion, complete all as specified and directed. |
| 92 | M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 93 | M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 94 | M & LAir termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 95 | M & L forconcealed point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia,with MS stove enamelled Modular type sunkenboxes including earth dollywith modular cover plate with frame of approved make and colour including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified anddirected for the followings :-One light / fan point controlled by one way switch |
| 96 | All as per Item No 96.00 here-in-above but for One 5 Amp socket outleton independent board complete all as specified and directed. |
| 97 | All as per Item No 96.00 here-in-above but for One 5 Amp socket outlet on same board complete all as specified and directed. |
| 98 | All as per above Item No 98.00 here-in-before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 99 | S & F of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directed with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and directed.Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 100 | S & Fsub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directedwith and including one run of6.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 101 | S & Fmodular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified and directed. |
| 102 | S & F modular blanking plate, 1 module ISI Marked complete all as specified and directed. |
| 103 | S & F modular type AC box 3 module operated with 20 Amp single pole MCB including 15 amp modular socket concealed in wallcomplete all as specified and directed. |
| 104 | S & F PVCround shape junction box cover of suitable size including complete all as specified and directed. |
| 105 | S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and directed. |
| 106 | S & F inenviroment friendly surface ( false ceiling)mounting 36 watt LED flat panel 2\"x2\" fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80,colour temperature cool day white/warm white as per user requirement including connection with existing wire and all accessaries all as specified and directed. |
| 107 | M & L for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed. |
| 108 | Supply and install hi wall split Type Air Conditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser,PM 2.5 Filter for better indoor air quality with 3 star rating and EER 3.2 of capacity 2.0 TR with precharged CFC free refrigerantwith hot and cold function all as specified and directed by Engr-in-Charge. |
| 109 | Supply and fix Voltage stabilizer forautomatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy