| 1 | Note: Please refer Schedule \"A\" Notes before quoting the tender. |
| 2 | General Summary |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’Part - I (Refer pre-priced schedule attached seperately). |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part - II (Refer pre-priced schedule attached seperately). |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part - III (Refer pre-priced schedule attached seperately). |
| 6 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part - IV (Refer pre-priced schedule attached seperately). |
| 7 | Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’Part - V (Refer pre-priced schedule attached seperately). |
| 8 | Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’Part - VI (Refer pre-priced schedule attached seperately). |
| 9 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part - VII (Refer pre-priced schedule attached seperately). |
| 10 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part - VIII(Refer pre-priced schedule attached seperately). |
| 11 | Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKSas listed in Schedule ‘A’ Part - IX (Refer pre-priced schedule attached seperately). |
| 12 | SCHEDULE \"A\" PART - X (MISCELLANEOUS ITEMS) |
| 13 | INTERNAL WATER SUPPLY WORKSNote: For items of INTERNAL WATER SUPPLY WORKS, notes given at the beginning of Schedule ‘A’ Part - II ( INTERNAL WATER SUPPLY WORKS) shall also be applicable. |
| 14 | S & F of Two way Bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down and screwed for iron pipe or for unions complete all as specified and directed. |
| 15 | S & F of chromium-plated Urinal spreader, for fixing with 15 mm dia pipe complete all as specified and directed. |
| 16 | INTERNAL ELECTRIFICATION WORKSNote: For items of INTERNAL ELECTRIFICATION WORKS, notes given at the beginning of Schedule ‘A’ Part - III (INTERNAL ELECTRIFICATION WORKS) shall also be applicable. |
| 17 | M&L point wiring for lightpoint wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and including 20 mm dia PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points (Ser Item No 6.02 to 6.06) .NOTE;-The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate. |
| 18 | One light point controlled by one way 6A modular switch. |
| 19 | One Ceiling/Exhaust fan point controlled by one way6A modular switch and regulator. |
| 20 | All as per Sl item No. 5.01 above, but with cable 1.5 sqmm for phase and neutral & 1.5 sqmm for earth continuity complete for 6 Amps socket point on same board complete all as specified and directed |
| 21 | All as per Sl item No. 5.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point on independent board complete all as specified and directedNote :- Maximum 4 points can be connected with single circuit |
| 22 | All as per Sl item No. 5.01 above, but with cable 4.0 sqmm for phase and neutral & 4.0 sqmm for earth continuity complete for 16/20 Amps socket point on independent board complete all as specified and directed |
| 23 | S&F for blank spacer plate for single module complete all as specified and directed. |
| 24 | S&F LED tube light fitting batten type, 40 W, 230v , efficacy not less than 100 Lumens per watt, colour temperature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%)and integrated electronic drivercomplete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed.Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 02 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. |
| 25 | S&F LED tube light fitting batten type, 20 W, 230v , efficacy 120 Lumens per watt, colour temperature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%)and integrated electronic drivercomplete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling roseall as specified and directed.Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 02 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. |
| 26 | Supply & Fixing LED tube light fitting batten type. 10 W, 230v , efficacy 120 Lumens per watt, colour temperature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20, THDv within 5% and THDi (8-10%) complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from ceiling rose all as specified and directed. Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 02 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. |
| 27 | Supply & Fixing LED Bulk Head luminaire 10 W, 230v , efficacy not less than 100 Lumens per watt, colour temprature 6000 K, power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20, THDv within 5% and THDi (8-10%) complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose complete all as specified and directed. |
| 28 | S & F LED Security light fitting 35 Watt, lumen efficacy of LED 120 lm/W, PF> 0.95, THD < 10%, colour temprature 5700K, CRI > 70, system lumen not less then 2600 Lm surge protection upto 3.5KV burning hrs 40000, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of GI Pipe 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sq mm three core from ceiling rose to fitting complete all as specified an directed. |
| 29 | Supply & Fix modular motor starter 20A, 2 module for, 240 Volts AC, ISI marked, suitable for modular switch boxes, complete all as specified and directed. |
| 30 | EXTERNAL WATER SUPPLY WORKSNote: For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Schedule ‘A’ Part - IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable. |
| 31 | Construction of stone masonry valve pit of Size 450 mm x 450 mm x 600 mm (Type \"B\") for gate valve all as specified and as per drawing including plastering, Plain Cement Concrete in foundation, excavation and earthworks in any type of soil, Mild Steel sheet cover 3 mm thick sheet with locking arrangements, painted with two coats of anti-corrosive paint over one coat of zinc chrome primeras per Typical Drawing CEBZ/TD/43/2011 complete all as specified and directed. |
| 32 | EXTERNAL ELECTRIC SUPPLY WORKSNote: For items of EXTERNAL ELECTRIC SUPPLY WORKS, notes given at the beginning of Schedule ‘A’ Part - V (EXTERNAL ELETRIC SUPPLY WORKS) shall also be applicable. |
| 33 | M&L for boring holes of size upto 50mm with horizontal drilling machine under the road for laying of pipes for protection of UG cables without damaging the road and making good thereafter all as specified and directed. |
| 34 | Supply and laying tubes, \"High Grade\", 40mm bore galvanised, with all fitting laid in trenches for protection of underground cables complete all as specified and directed. |
| 35 | SEWAGE DISPOSAL WORKSNote: For items of SEWAGE DISPOSAL WORKS, notes given at the beginning of SCHEDULE \"A\" PART - VIII (SEWAGE DISPOSAL WORKS) shall also be applicable. |
| 36 | M & L for Construction of Septic Tank for 100 users desiged to carry sewage and sullage water, excacation in ordinary soil, foundation in Plain Cement Concret 1:4:8, Reinforced Cement Concrete M-30 Design Mix in walls, base slab, baffle walls and roof slab including berms etc. with vent shaft and sluge chamber, manhole openings with cover, conections etc. complete with effective depth of 1.5 m and overall depth of 3 m with Brickwork in Cement Mortar 1:4 etc. as per Typical Drawing CEBZ/TD/76/2011 complete all as specified and directed. |
| 37 | M & L for Construction of Soakage Well 2.4 m dia x 4.50 m deep, excavation in ordinary soil, foundation in Plain Cement Concret 1:3:6, wells of honey combed masonry with bands of M-25 Concrete including intercepting chamber and screen chamber, Brickwork in CementMortar 1:4, RCC cover slab & interconnecting pipes of RCC/DWC complete filled with brick bats as per Typical Drawing CEBZ/TD/78/2011 complete all as specified and directed. |