| Sl. No. | Item Description |
| 1 | M&L for preparation of plastered or un plastered old decorated surfaces of walls by Vacuum based sanding machine all as specified,removal of nails etc & filling cracks/hole by applying wall careputty (multi purpose mixer shall be used for uniform and proper mixing of putty)and applying one coat of white wash on celling by auto roller & leaving premises clean and tidy,complete all as specified & directed by Engineer-in-Charge. |
| 2 | Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces.rcomplete all as specified & directed by Engineer-in-Charge. |
| 3 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 4 | M&L for complete removal of existing treatment from old decorated plastered surfaces of walls by Vacuum based sanding machine complete all as specified,removal of nails etc & filling cracks/hole with putty,(multi purpose mixer shall be used for uniform and proper mixing of putty) and applying two coats oil emulsion distemper white or coloured over a coat of approved primerby auto rollercomplete all as specified & directed by Engineer-in-Charge. |
| 5 | M&L for 2mm thick birla with putty complete all as specified and directed. |
| 6 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar complete all as specified & directed by Engineer-in-Charge. |
| 7 | M&L fornon skidceramictile 7 to 8mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match including 15mm thick screed bed or bedding layer of mortar for laying floor finishes withCM 1:6 complete all as specified & directed by Engineer-in-Charge. |
| 8 | M&L fornon skid ceramictile 7 to 8mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match including 15mm thick screed bed or bedding layer of mortar for laying floor finishes withCM 1:6 complete all as specified & directed by Engineer-in-Charge. |
| 9 | All as per item no 8 above but on vertical face/skirtingincluding 10mm thick backing coat or bedding layer of mortar for laying floor finishes withCM 1:4 complete all as specified & directed by Engineer-in-Charge. |
| 10 | M&L for Glazed ceramic coloured walls tilesin vertical surfaces 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering for backing coat on vertical surface of wall or concrete surfacesin CM 1:4 to receive wall tiles complete all as specified & directed by Engineer-in-Charge. |
| 11 | M&L for Machine cutkota stone slabforPlatform top and sides20-25mm thick overcement 15mm thick backing coat laid andjointed withCM 1:4 grey cement slurrymixed with pigment to match theshade of the slab including rubbingand polishing complete |
| 12 | M&L for 20mm thick Granite (of any type) work(table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cementmortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite incl rounding edges including 15mm thick screed bed or bedding layer of mortar for laying floor finishes withCM 1:6 complete all as specified & directed by Engineer-in-Charge. |
| 13 | M&L forGreen Marble work 16 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 15mm thickin cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble to match overand including all sides rounding edge complete all as specified and directed. |
| 14 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge. |
| 15 | S & F 16mm bore high density CPVC CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specifie all as directed. |
| 16 | Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge. |
| 17 | S & F 25mm bore high density UPVC pipe of pressure rating 6kgf/sqcm with all fittings and fixed complete to walls and ceilings or laid in floors all as directed. |
| 18 | Taking up or down 50mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge. |
| 19 | S & F 50mm bore high density UPVC pipe of pressure rating 6kgf/sqcm with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified & directed by Engineer-in-Charge. |
| 20 | M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement concrete type B1, 1:2:4 for 75mm bore complete all as specified & directed by Engineer-in-Charge. |
| 21 | S&F in repair beveled edge mirror 5 mm thick of selected quality glass mounted on fancy decorated frame and fixed to wooden plugs with chromium plated brass screws and cup washers with aluminium beading complete all as specified and directed. |
| 22 | S & F in repairs 530x380x400 mm Vitreous China wash down water closet pan pedestal pattern (Europian type) (excluding flushing cistern and flush pipe) plastic seat same colour of seat, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 23 | S & F in repairs PVC valvless syphonic action flushing cistern low level white of 10ltrs capacitywith inlet ball valve float and handle including bracket complete all as specified & directed by Engineer-in-Charge. |
| 24 | S&F in repairs health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed by Engineer-in-Charge. |
| 25 | S&Fin repairs PVC connection 600mm long of dia 15mm complete all as specified & directed by Engineer-in-Charge.. |
| 26 | S&F in repair Vitreous China counter sunkwash hand basin, round shape dia 600mm white excluding taps, waste chains and plugs and porcilain stopper but including CI bracket and nut bolts as per maufacturers instructions complete all as specified and directed.(Make: cera, jaquar) |
| 27 | S&F in repairs 32mm dia flexible waste pipe for urinal, washbasin and kitchen sink for length exc. 1m not exc 2m complete all as specified & directed by Engineer-in-Charge. |
| 28 | S&F in repairs 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall as in waste/soil pipe complete all as specified and directed |
| 29 | S&F in repairs 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall as in waste/soil pipe complete all as specified and directed |
| 30 | S&F in repairs 110 mm dia PVC (SWR) bends of any radius with access door complete all as specified & directed by Engineer-in-Charge. |
| 31 | S&F in repairs 75 mm dia PVC (SWR) bends of any radius with duck foot or heel rest fitted with oval access door complete all as specified & directed by Engineer-in-Charge. |
| 32 | S&F in repair sheet glass shelf with 5.5mm thick sheet glass shelf 12cm wide with chromium plated guard and railing 60cm long complete all as specified & directed by Engineer-in-Charge. |
| 33 | S & F in repairs 25 mm dia stainless steel tubular curtain rod includingbracketsfancy type (design of socket shall be approved by GE/AGE at the time of execution) complete all as specified & directed by Engineer-in-Charge. |
| 34 | S&F in replacement including disconnecting tanks, 1000 ltrs rotational moulded Triple layred high qualityinsulation gives protection against tempreture variation with self locking lid with hexa bolts with anti algae , polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I. |
| 35 | S&F 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 142 gms) complete all as specified and directed. |
| 36 | S&F in repairs 15mm dia stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle for iron pipe complete all as specified & directed by Engineer-in-Charge. |
| 37 | S&F in repairs, 15mm bore bib taps fancy type chromium platedcast copper alloy with capstan heads, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed. |
| 38 | S&F in repairs brass CP centre hole WHB mixer for mixing hot & cold water two way screwed down for iron pipe 15mm bore and fixed complete all as specified and directed. |
| 39 | S&F in repairs chromium plated shower rose with or without swivel joints any size, including fixing to GI pipe for 125mm dia complete all as specified & directed. |
| 40 | S&F in repairs brass CP wall mixer for mixing hot & cold water three way screwed down for iron pipe 15mm bore and fixed complete. |
| 41 | S&F in repairs, towel rail 600mm Long with Lower Hangers, Stainless Steel complete all as specified and directed. |
| 42 | Demolition of Brickwork or stone/boulder masonry, built in cement/cement lime mortar including all quoins, arches, pillars, ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling etc. all as specified and directed. |
| 43 | M&L for brickwork with sub class ‘B’ old sizebricks straight or curved on plan exc 6 mmean radius built in CM 1:6 complete all as specified & directed by Engineer-in-Charge. |
| 44 | Taking down cement plaster on brick or stone walls / ceiling, etc. including raking outjoints, hacking for key, scrubbing down with water, etc complete all as specified & directed by Engineer-in-Charge. |
| 45 | M & L for 10 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfacesand surface finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge. |
| 46 | M & L for rendering 5mm thick on brick wall surface or concrete surfaces of ceiling in cement mortar 1:3 for finished even and smooth (without using extra cement) complete all as specified & directed by Engineer-in-Charge. |
| 47 | M&L for Rendering in two layer onfair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPC@ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering incement mortar 1:6smooth without using extra cement (WPC will be measured separately) complete all as specified & directed by Engineer-in-Charge. |
| 48 | Supply only Integral water proofing compound complete all as specified & directed by Engineer-in-Charge. |
| 49 | M&L for preparingnew plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified & directed by Engineer-in-Charge. |
| 50 | M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distamper over and including a coat of 2mm average thick birla/equivalent 3mm thick wall care putty and one coat of alkali resistance primer complete all as specified & directed by Engineer-in-Charge. |
| 51 | S&F 150 mm extruded brasshandles, fabricated type anodized complete all as specified and directed. |
| 52 | S&F 300mm brass sliding door bolts, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alluminium alloy complete all as specified and directed. |
| 53 | S & F 150 mm long brass barrel tower bolt of extruded section and fixed, complete all as specified & directed by Engineer-in-Charge. |
| 54 | S&Fstainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised staples complete all as specified and directed. |
| 55 | M & L for 4.0mm thick figured glass, n.exc 0.5 Sqm and glazing with rubber beading or with glazing clips, complete all as specified & directed by Engineer-in-Charge. |
| 56 | M & L for 4 mm thick sheet glass with black film,n.exc 0.5 Sqm each pane ordinary quality and glazing with rubber beading or with glazing clips, complete all as specified & directed by Engineer-in-Charge. |
| 57 | S & F powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified & directed by Engineer-in-Charge. |
| 58 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots andfixing of all fittings and fixtures wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 59 | Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each and making good disturbed portion to match with existing complete all as specified & directed by Engineer-in-Charge. |
| 60 | Taking down chowkats or frame with shutter (without taking off shutter from the frame) exc 1.5 but n.exc 4sqm each and making good disturbed portion to match with existing complete all as specified & directed by Engineer-in-Charge. |
| 61 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). →Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made completeall as specifed and directed. |
| 62 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified & directed by Engineer-in-Charge. |
| 63 | S&F 30mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge. |
| 64 | S&F 30mm thickFlush shutters, solid core construction, with block board core anddecorative face veneer withlipping/frame to match on both sides complete all as specified and directed. |
| 65 | S&F for mild steel Framed work as in doors orgates or grill/grating of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified & directed by Engineer-in-Charge. |
| 66 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as directed. |
| 67 | S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ150 as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 68 | S & F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ150as in roof covering/cladding ridge or hips, valley gutter to wall, fixed with self tapping screws as specified. |
| 69 | Dismantling Structural steel work including doors,gates but excluding framed truss etc. |
| 70 | M & L for mild steel work confirming to Fe-290 Gde E-165 in Roof truss(framed), trussed,purlins,cranegantries, rails and fasteningsand heavy bracket framing(Beam,tee,angle,channel or flat sections)including distance pieces cleats etc. |
| 71 | S&F in repairs, SS gratings 150mm Square made in two parts for smell and mosquito proofing with minimum 25mm water sealcomplete all as specified and directed. |
| 72 | Grubbing up tree trunk including cutting of trunk portion all around from building periphery upto 2m distace protrudingover ground, digging out roots, filling holes, trunk around periphery ofbuilding upto 3m and leveling off ground periphery of building upto 2m, stacking of serviceable material and removing of unserviceable material to a distance n exc. 500 m and clearing site |
| 73 | S&F in repairs sinksmade of stainless steel 1 mm thick kitchen with plugs, washers and waste , including bedding in cement mortar on to dwarf wall or including fixing cantiliver brackets and connecting union to pipe, overall size 495mm x 420 mm & bowl size 410mmx330mm x 160mm complete. |
| 74 | S&F in repair mild steel helical door spring 300mm ordinary rat tail rod pattern springs including roller plate complete all as specified and directed. |
| 75 | S&F in repair 18mm thick HDHMR BOARD exterior grade including any coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century. |
| 76 | S&F in repair 18mm thick HDHMR BOARD exterior grade including white coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century. |
| 77 | S&F in repair partial overlay/fully overlay hydraulic self closing concealed hinges having size 103mmx64mm finish of nickel/silver all as specified and directed. |
| 78 | S&F in repair stainless steel cabinet/drawers handle having a length of 100mm and shape all as specified and directed. |
| 79 | Dismantling posts or struts any type and any section including taking out embedded portion in concrete, brick work, masonary etc, and making good disturbed ground complete all as specified. |
| 80 | Fixing only chainlink fencing including line wires, any meshany type to standrard rails, straining bolts etc, including provn of binding wire etc complete all as specified |
| 81 | Supply only MS galvanised chain link fencing, any size or type |
| 82 | Supply only mild steel round bar of grade Fe-290(Gde E-165) complete all as specified and directed . |
| 83 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc.) complete all as specified & directed by Engineer-in-Charge. |
| 84 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc.) complete all as specified & directed by Engineer-in-Charge. |
| 85 | M&L for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof of any thickness complete all as specified & directed by Engineer-in-Charge. |
| 86 | M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof)mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified & directed by Engineer-in-Charge. NOTE:-Liquid water proofing compound shall be measured and paid for separately as “Supply only”. |
| 87 | M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mmthick) weight not less than 3.00 Kg/sqm and reinforced with non-woven polyster reinforcement/mat (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over and including a coat of bitumen S-35 (30/40) @ 1.20 kg/sqm over and including a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 0.40 litre/sqm and providing two coat Aluminium Paint over all as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge. |
| 88 | M&L for cement concrete 1:4:8 type D-2using 40mm graded stone aggregate 75mm thickas in sub base to flooringincluding necessary form work complete all as specified & directed by Engineer-in-Charge. |
| 89 | M&L for cement concrete 1:3:6 type C-2using 40mm graded stone aggregate 75mm thickas in hard standing/Plinth protectionincluding necessary form work and finishing surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge. |
| 90 | M&L rubber moulded glossy finish precast concrete interlocking paver block any size and shape conforming to IS 15658-2006 of 60mm thickness, M-35Grade with grey cement andpigment including sypplying ,spreading and levelling sand cushioning 50 mm thick complete all as specified & directed by Engineer-in-Charge. |
| 91 | Providing cement concrete type B0 12.5 mm graded stone aggregatein lintels upto1.5m clearspan,cills,steps; seismicand other similar bands, plinth courses, string courses, lacing courses, parapets andrailings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not providedfor in Item 04028, watertroughs and the like includingweathering,slightly roundedor chamfered angles andthroating, as directed |
| 92 | Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch,sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor etc. |
| 93 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 94 | M&L for taking down carefully sub main wiring including batten any type of conduit by unscrewingfrom floor,wall,ceiling and making good surfaces to match with original status for all types of sub main wiring. |
| 95 | M & L for concealed point wiring complete with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in includingPVC conduit not less than 20 mm dia concealed duly fixed with U-Clips, including cutting chases, finising of slote by means of cement mortormakinggood to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed Modular Metal flush box of required size not less than 2 mm thick GI Plate factory made with modular cover plate, screw with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified for the following:- |
| 96 | For one light, fan point controlled by one switch |
| 97 | For call bellpoint controlled by one switch |
| 98 | For one5 Amp independent socket point controlled by one switch |
| 99 | For one 3 pin ,5 Amp socket point with other switch on the same board |
| 100 | For one light, point controlled by two wayswitch |
| 101 | All as per item No95 here in before but for power point wiring usingwith 2.5sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge. |
| 102 | S&F Modular switch 1 way 6A, 1module. |
| 103 | S&F Modular switch 2 way 6A, 1module. |
| 104 | S&F Modular call bell switch 1 way 6A, 1module. |
| 105 | S&F Modular Socket, 6A - 2/3 pin combined 2module. |
| 106 | S&F Modular switch 1 way 16A, 1module. |
| 107 | S&F Modular Socket, 16A - 3/5 pin combined 2module. |
| 108 | S&F Modular Fan step regulator, 120W - 2 module. |
| 109 | S & F ceiling rose surface polycarbonate body three terminal. |
| 110 | S & F Lamp holder, PVC type with back plate suitable for batten fittings including LED lamp 9 Watt complete all as specified and directed. |
| 111 | S & F of ceiling fan operated with blades, anti suicide rod from existing roof / trus to fall ceiling, electronic regulator operated and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note :1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 112 | S & F of LED light fitting 20 Watts (4 Feet), 220 Volts AC, Aluminium extrusion , input 140-270 Volts AC, CCT 6000K, luminus efficiancy 100 lumens/watt, surge protection upto 4KV volage protection upto 440V, AC, PF >0.9 and including LED light fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 113 | S & F of LED light fitting 10 Watts (2 Feet), 220 Volts AC Aluminium extrusion , input 140-270 Volts AC, CCT 6000K, luminus efficiancy 100 lumens/watt, surge protection upto 4KV volage protection upto 440V, AC, PF >0.9 and including LED light fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 114 | M&L concealed Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 20 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 115 | S&F sheet metal enclosure for DB double door SPN 12 Ways, IP-43 240 V with 200 Amps rated bus bar including taking down.Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 116 | S&F sheet metal enclosure for DB double door SPN 8 Ways, IP-43 240 V with 200 Amps rated bus bar including taking down.Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 117 | S&F sheet metal enclosure for DB double door TPN 04 Ways, IP-43 240 V with 200 Amps rated bus bar including taking down.Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 118 | S&F testing and commissioning of MCB TPN 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 119 | S&F testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs including taking down. |
| 120 | S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. All as specified and directed by Engr in charge. |
| 121 | S & F in replacement Bell ding dong type, one way, 240 volts, AC, ISI marked. |
| 122 | S & F of LED bldg security light fitting 35 Watt input voltage 140-270V AC outdoor type with high robustdie cast body aluminium housing CCT 6500K lumeinous efficincy > 120 lumens/watts CRI > 70, PF >0.95 protection class IEC safety class-Iand heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete including old U/S taking down complete all as specified and directed. Mak : Havells/Philips/Bajaj .Note :- The warranty on light should be ofminnimum3 Years . |
| 123 | Taking down existing energy meter, kept in safe condition and refixing after completion of new wiring at same location with PVC Box as per direction of Engr-in-Charge. |
| 124 | M&L for Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion and including old U/S taking down.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |