Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-01-2026 | Amendments No.01 | BOQ | 23-01-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of brick/stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as directed. |
| 2 | Material & labour for brick work old size bricks built in CM (1:6) straight or curved exceeding 6mtr mean radius complete all as specified and directed. |
| 3 | M & Lbrickwork with sub class ‘B’ bricks straight or curved to any radius in half brick thick walls builtin CM 1:4 |
| 4 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n.exc.4 Sqm each |
| 5 | Same as per item No 4 above but area n.exc. 1.5 Sqm each |
| 6 | S & F for mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., Fe-290 (Gde E-165) complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 7 | M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE. |
| 8 | M&L 35mm thick 2nd calss hard wood (factory made) glazed and skeleton shutters, open rebated and prerpared to receive glass, gauge, etc edges of trimming plain chamfered or roundedfitted with cut and metered beads for securing/ gauge etc sizes of members of shutters as specified in SSR Part-I Section 8.20 (a) and all as specified. |
| 9 | S & F solidPVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade.The door frame shall be tied to the wall using 75/100mm long MS screw as directed . |
| 10 | S & F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheetto be fitted in the MS frame welded/ sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete all as specified and directed. |
| 11 | S & F Mortice lock, vertical type, size 100 mm 4 lever brass type complete all as specified and directed. |
| 12 | Supply andfixing 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/PVC door frame with screw complete all as specified and directed. |
| 13 | S&F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and staples. |
| 14 | S&F aluminium alloy handle 150 mm cast type anodised all as specified. |
| 15 | S&F 150 mm aluminium anodised barrel tower bolts of extruded section and fixed. |
| 16 | S & F 150mm longfloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring etc and all as specified and directed |
| 17 | S & F magnetic ball catcher of suitable size for cup board shutter all as per sample approved by Engr-in-Charge complete all as specified and directed |
| 18 | S & F adjustable door spring capsule typeof medium size all as per sample approved by Engr-in-Chargecomplete all as specified and directed |
| 19 | S & F in repairs aluminum door seal of suitablesection fixed to door shutter with screw complete all as specified. |
| 20 | M & L for mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed |
| 21 | S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 22 | S&F of Powder coated aluminium window/ventilator shutters, side hung/sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws and grill etc as per manufactures instruction & trade pactee. |
| 23 | Supply and fix sheet glass 4 mm thick oridinary quality and glazing with rubber packing to sliding windows/ventilators in square exceeding 0.50 sqm in each pane. |
| 24 | Supply and fix figured glass 4 mm thick pin headed type and glazing with rubber packing to sliding windows/ventilators in square not exceeding 0.50 sqm in each pane. |
| 25 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm dia and fixed with tinned tacks of galvanized wire staples and wooden bedding. |
| 26 | Demolition of cement concrete (Unreinforced) in ground floor and pavingn.exc 15 cm thickness (below or above ground level). |
| 27 | M & L for 75 mm thick PCC 1:3:6mix type C2 using 40mm graded stone aggregate as in paving finishing cone surface (plinth protection) even and smooth without using extra cement. |
| 28 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 29 | M & L for 25 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded stone aggregate) with liquid water proofing compound as per manufacturers instructions for laying floor tiles. Note (WPC will be measured and paid separately). |
| 30 | M&L fornon skid colour ceramictile 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm , as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile colorincluding screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:4 (Tile pattern and decoration may be as suggested by Engineer-in-charge) |
| 31 | M&L fornon skid colour ceramictile of size 600x600mm, 7 to 8 mm thick area of each tile, exceeding 0.18 sqm but not exceeding 0.38sqm , as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile colorincluding screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:4 (Tile pattern and decoration may be as suggested by Engineer-in-charge) |
| 32 | M&L for non - skid colured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm thick in CM 1:3 (Tile pattern and decoration shall be directed by Engineer-in-charge) |
| 33 | M & L for glazed ceramic coloured wall tiles in vertical surface 300x 200/350x250/450x350mm &7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid overincluding 10 mm thick rendering as in vertical serfaces of wall finishes withCM 1:4 to receive wall tiles (Tile pattern and decoration shall be directed by Engineer-in-charge) |
| 34 | M & L for 18 to 20 mm thick machine cut green marbel stone in single piece in riser of steps, skirting, dado, window (Jambs/Cills), and pillar laid over cement screed and jointed withbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 4 complete all as specified |
| 35 | M & L for 18 to 20 mm thick machine cut green marbel stone as in flooring, in steps in single piece over cement screed and jointed withbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20 mm thick screed bed with cement mortar 1 : 4 complete all as specified |
| 36 | Taking down cement plaster from brick/concrete surface including racking out joint hacking for key scrubbing down with water etc complete all as specified and directed. |
| 37 | M & L Rendering 15 mm thick onfair faces of brick work or concrete surfaces of wall in cement mortar 1:6 forfair finishedcomplete all as specified and directed. |
| 38 | M & L for 15mm thick rendering in two layer on brick work or concrete surface of wall. 5mm thick plaster in CM:1:4 mixed with WPC as per manufacturer instructions ment surfacefinished even and smooth without using extra cement over 10mm thick plaster in cement mortor 1:6 complete all as specified and directed.(Note : WPC shall be measured & paid separately) |
| 39 | M&L Rendering 05 mm thick onfair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:3for finished even and smooth (without using extra cement) |
| 40 | Supply only liquid water proofing compound (Dr Fixit Pidifin/ Fosroc/Sika) |
| 41 | M & L for preparingnew plastered surfaces of wall and applying two coats of oil bound distemper overa coat of 2mm average thickwater proof birla/ equivalent wall care putty and one coat of alkali resistant primer all as specified and as directed. |
| 42 | M & L for prepartion newly plastered surface of ceiling and applying two coat of oil bound distemper over a coat of alkali resistant primercomplete all as specified and directed. |
| 43 | M& L for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 44 | M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distemper over a coat of 2mm averagethickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 45 | M&L for preparation of newly wooden surface of any description not otherwise descsribed over 10 cm width or girth with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 46 | M&L for preparation of newly steel surface of any description not otherwise descsribed over 10 cm width or girth with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 47 | M&L for preparation of old steel surface of any description not otherwise descsribed over 10 cm width or girth with two coats of synthetic enamel paint complete all as specified and directed. |
| 48 | S & F in repairs 25mm dia stainless steel 202 grade tubular curtain rod as directed |
| 49 | S & F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be approved by GE/AGE at the time of execution) as directed |
| 50 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth for bore of pipe 15/20 mm complete all as specified. |
| 51 | Taking down steel tubing and connection including cleaning for refixing the same in new or old position all as directedof following size fixed on wall and ceilings: |
| 52 | 15mm dia |
| 53 | 20mm dia |
| 54 | S & F20mm dia galvanised iron tubing (ISI marked) medium grade including all necessary fittings and fixed to wall / ceiling or laid in floor jointed with necessary fittings and fixed to wall / ceiling or laid in floor jointed with tuflon tape all as specified. |
| 55 | S & F20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 56 | S&F in repairs 60cm long CP Brass 20mm dia D type tubular towel rail with flanged ends. |
| 57 | S & F in repairs C.P grating of size 150 x 150 mm. |
| 58 | S&F 600x450mm bevelled edge mirror of selected quality glass 6mm thick with PVC moulded frame and mounted on AC building board or commercial ply wood and fixed with wooden ply with chromium plated brass screws and cup washers. |
| 59 | S&F in repair Vitreous china premium/ 1st quality wash down water closetwall hung type EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified etc. complete including making good to floor. complete all as specified and as directed. |
| 60 | S&F in repairs Plastic water closet seat,white or black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 61 | S&F in repairs Vitreous China wash down water closet (Squat pattern ) white complete as fixed in repair excluding flushing cisternand flush type \"Orrisa\" pattern size 580x440 with integral footrest inject connection to trap antisyphonage etc complete including joint between flushing pipe and socket of WC. |
| 62 | S&F in repairs PVC flushing cistren low level, 10 ltr capacity with syphonic action type ball valve. Incl inlet ball valve,PVC band (flush pipe) 32mm complete all as specified. |
| 63 | S&F in replacement Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 64 | S&F in repair vitreous China urinals, half stall urinal (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including fixing supply pipe to flushing cistern, urinal spreader, trap and waste pipe, complete all as specified and directed. |
| 65 | S&F in repairscabinate mirror rectangular shape with selected quality mirror and PTMT frame with opened door shutter with acrylic frame oustside mirror at famed of overall size 450 mm X 600 mm with sheles in side suitabele for Bath room complete all as specified and directed. |
| 66 | S&F in repair vitreous china Wash hand basin, white , size 550x400 mm oval type below counter basin except taps, CP waste coupling but incl brackets all as specified. Make cera/Hindware |
| 67 | M&L Granite 20mm thick colour as approved by Engr-in-Charge (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms including cutting and nisking hole for oval wash hand basin and like in cement mortar (1:4) including pointing in white cement (1:2) using markie rusi with admixture of pigment to match with shade of granite over 15mm thick screed bed in cement mortar 1:6) complete all as specified and directed. |
| 68 | M&L for Granite 18 to 20mm thick colour as approved by Engr-in-Charge (table rubbed and polished) for wall lining veneering to wall; 12mm thick in cement mortar (1:3) including isinting in white cement (1:2) using marble dust with admixture of pigmentto match with shade of granitecomplete all as specified and directed. |
| 69 | Supply and fixing CP Centre hole Wash Basin mixer three in One 15 mm bore pipe complet all as specified. |
| 70 | Supply and fix PVC (SWR) Floor trap of size 75mmsetting and jointing with solvent cement. |
| 71 | Supply and fix PVC (SWR) Gully trap of size 125/110mmsetting and jointing with solvent cement. |
| 72 | S & F in repairs15 mm bore CP stop cock/Angle cook cast copper alloy,fency type screwed down high pressure with capston head screwed for iron pipe |
| 73 | S & F in repairsCP bib tap fancy type 15 mm bore cast copper alloy with round operating knob screw down screwed for iron pipe complete all as specified. |
| 74 | S & F in repair CP wall mixer three in one system for mixing hot and cold wather screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed. |
| 75 | S & F in repair Toilet Paper holder of chromium plated fixed to all with chromium brass screw complete all as directed. |
| 76 | S & F in repair 15 mm bore MS chromium plated shower rose of size 125 mm heavy grade with accessories completed all as specified. |
| 77 | S & F in repairs Chromium plated soap dish heavy duty fixed with brass screw complete all as directed. |
| 78 | Dismantling of water storage tank of 500 ltrs capacity. |
| 79 | S & F rotational moulded PVC water storage tank 1000 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type Four-layered, white coloured with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I, including S&F Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed |
| 80 | Supply & Fix in repair 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete all as specified and directed. |
| 81 | Supply & fix in repair 20 mm bore Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipecomplete all as specified & directed. |
| 82 | Supply & fix in repair glass corner shelf assembly fancy type made of 6 to 7 mm thick sheet glass of size 250x 250mm fixed with CP brackets complete all as specified and directed. |
| 83 | Taking down soil waste and vent pipe (any size or pattern) including all fittings complete all as specified and directed. |
| 84 | S & F 110mm PVC (SWR) WC connector with lip ring all as specified and as directed. |
| 85 | S & F 110mm PVC (SWR) WC connector bent type to fit WC outlet all as specified and as directed. |
| 86 | S & F 110mm PVC (SWR) junction single, (Single T, \"Y\" type) equal or unequal all as specified and as directed. |
| 87 | S & F 75mm PVC (SWR) junction single, (Single, \"Y\" type T) equal or unequal all as specified and as directed. |
| 88 | S&F 40mm bore UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe |
| 89 | S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed |
| 90 | S & F 110mm PVC (SWR) vent cowl all as specified and as directed |
| 91 | S & F 75mm PVC (SWR) vent cowl all as specified and as directed |
| 92 | S&F PVC (SWR) bends without access door suitable for 75mm Bore pipe fixed complete. |
| 93 | S&F PVC (SWR) pipes, 75 mm bore, single socketed pipe in any length with rubber ring joints laid in floor or trenches fixed complete |
| 94 | S& F PVC (SWR) pipes, 110 mm bore, single socketed pipe in any length with rubber ring joints laid in floor or trenches fixed complete |
| 95 | S & F PVC (SWR) bends without access door suitable for 75 mm mm bore pipe fixed complete. |
| 96 | S & F PVC (SWR) bends with access door suitable for 100 mm mm bore pipe fixed complete. |
| 97 | S & F in repair PVC connection 15mm bore with PTMT nut of length 450mm complete all as specifed and directed. |
| 98 | M&L for cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in coping bed plate for hold fast etc including necessary from work etc complete all as specified and directed. |
| 99 | M & L for complete removal of loose / cracked concretefrom RCC roof projection,chajja,fins,facia, roof bands etc and making good with PCC (1:11/2; :3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in anyposition finished the surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement)if required complete and applying three coat of white wash/two coat of cement base pintto match with the existing surface as directed by the Engr- in -Charge . (Reiforcement will be measured and paid saperately under respective item. |
| 100 | Material and labour MS TMT bars 8-10 mm dia, cut to length bent to shaperequired including cranking/ Binding/ hooping of coloumns/hooking endsand binding with and including MS wire ( annealed) not less then 0.9 m dia or securing with clips complete |
| 101 | M&L for sunken treatment of WC/Bath with polymeric membrance (APP based) with non woven polyster mat as reinforcement including water tightness test with filling of water for continuous 48 hours with following :- |
| 102 | Demolition of existing PCC /lean concrete including floor tiles and removing rubbish off the premises. |
| 103 | M&L for 15 mmthick plaster in sunken portion with CM 1:3 mixed with water proofing compound as per manufactures instructions plaster surface should be even and smooth without using extra cement all as directed. Note . (WPC will be measured and paid separately as supply only). |
| 104 | M&L for providing & laying APP based polymeric membrance of weight of 3 kg/sqm with non woven polyster fibre as reinforcement over a coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm by torch application with side over laps & longitudinal joints over laps etc as per manufacturer instructions complete all as specified and as directed.. |
| 105 | M&L for sunken portionfilled with lean concrete 1:5:10 using brick/lime aggregate and finish the surfaces rough to receive sub base complete all as specified and as directed. |
| 106 | M & L for 25 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded stone aggregate) with water proofing compound as per manufacturer instructionsfor laying floor tiles. Note (WPC will be measured and paid separately as supply only). |
| 107 | M&L for followings complete all as specified and directed :-(A) Surface Preparation and Concrete Removal:-(i)Removal of plaster and finishes from all sides of columns (full height), three sides of beams (full span), and bottom of slabs over specified areas, as directed by the Engineer-in-Charge.(ii) Removal of cover concrete around reinforcement (using pneumatic or electric chippers or other approved tools) until reinforcement is fully visible.(iii)Undercutting of concrete up to 20mm beyond reinforcement around the full circumference of columns and full length of reinforcement in beams/slabs as directed.(iv) Cleaning of exposed concrete surface using water jet.(v) Manual removal of rust from exposed reinforcement using hand tools.(B)Anti-Corrosive Treatment to Reinforcement:(i) Cleaning of exposed reinforcement bars (old and new) around all sides.(ii) Application of one coat of alkaline rust-converting primer as per manufacturer\"s recommendation.(iii) Application of two coats of epoxy phenolic anti-corrosive protective coating on all exposed reinforcement bars, including rear portions close to the concrete substrate.(C)Application of Polymer Modified Cementitious Mortar (PMM):(i) Preparation of the substrate surface (dry and free of debris).(ii) Application of epoxy bond coat using approved spray equipment, ensuring no pin holes. If pin holes are visible, apply a second coat.(iii) Application of PMM in layers totaling 30mm thickness (preferably 10mm coats), completing the work within 30 minutes.(iv) PMM shall be pre-packed and ready-to-use as per the manufacturer’s instructions.(v) Moist curing of PMM for 3 days, followed by air curing under recommended conditions.Notes:-(i)All work to be carried out in accordance with the specifications and as directed by the Engineer-in-Charge.(ii) The rates shall include all labor, materials, tools, machinery, transportation, and incidental costs.(iii) Any wastage or additional work required will be at the contractor’s expense unless otherwise directed by the Engineer. |
| 108 | M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-10-12 mm dia bar - drilling length 80 to 100 mmNote: Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all as specified and directed. |
| 109 | M&L for use & waste of form work using steel/Hard Plywood sheets, steel bracing, propping etc around sides of columns and other structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed Note:- Form work shall be 100% leak proof. |
| 110 | M&L for Providing & Pouring Micro concreting M-40 grade with the following operations :-(i) Dry concrete substrate surface and free of debris & dustii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BAS or equivalent in FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer\"s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.Note: Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item. |
| 111 | M&L for Providing reinforced cement concrete (nominal mix) Type B1, 1:2:4 (using 12.5 & 20 mm Aggregate) as inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. Note. (reinforcement shall be measured and paid separately) |
| 112 | S&F for stengthening existing reinforcement by use of mild steel TMT bars of any dia, cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 113 | M&L for Hard drawn steel wire fabric weight per square meter not exc 4.0 kg, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt, complete all as specified and directed. |
| 114 | Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store if reservicable condition for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge. |
| 115 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 116 | M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVCConduit and all accessoriesConcealedinwalls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with modular white cover plate with frame for housing the switches, socket outlets, fan regulators and blank cover etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:- |
| 117 | One light point controlled by one switch. |
| 118 | One ceiling fan point controlled by one switch and fan regulator. |
| 119 | One exhaust fan point controlled by one switch. |
| 120 | One bell point controlled by one bell push |
| 121 | One 3 pin socket outlet 5 Amps independent board. |
| 122 | One 3 pin socket outlet 5 Amps on the same board with other switch. |
| 123 | One light point controlled by two Nos two way switches |
| 124 | All as per item No. 110 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket. |
| 125 | S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge. |
| 126 | S&F Modular switch, two way, 6 Amp 230, 1 module.all as specified and directed by Engr in charge. |
| 127 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt |
| 128 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . |
| 129 | S&F socket Modular 6 Amp-2/3 pin combined 2 module |
| 130 | S & F ceiling rose surface polycarbonate body three terminal with ISI marked. |
| 131 | S&F Modularlamp holder Polycarbonate type with back plate suitable for Batten fittingSuitable for B22 type bulb with ISI marked. |
| 132 | S&F modular fan step regulator 120W2 module. |
| 133 | S&F modular bell push 6A ,1 module |
| 134 | S&F call bellding dong230 Volt , single phase. |
| 135 | S & F of BLDC White colour ceiling fan complete with blades electronic regulator, down rod and accesories from existing roof / trus to fall ceiling,and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE,Winding material 100 % copper ,350RPM air velocity 215m3/min,anti rust bladesfive star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note :1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 136 | M&L electric water heater (Geyser)25 Ltrs capacityAC 230V, 5 star rating Branded heavy duty automatic cutoff and including electric connection lead and water connection of both power consumption 2000 watt of suitable size and length and all accessories, grouting of nut bolt/fastner on wall and making good disturbed surface completeincluding diconnecting & taking down old geyser all as specified and directed. Note : 1) Old water heater(Gyser) shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 137 | Supply and fixing in replacement LED lights fittingmade of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed byEngr -in -charge. Note :Warrenty on light should be of minimum 02 Years provided by contractor. |
| 138 | Supply and fixing in replacement LED light fitting made of Aluminium extrusion mirror type with high out put diffuser 1x10 watt 2 feet, input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 with driver including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Note : Warrenty on light should be of minimum 02 Years provided by contractor. |
| 139 | S&F in replacement LED bulb B22 9 watt inverter bulb ,lumin efficency 900 lumin/watt in normal mode and 350 lumin/watt in power backup mode,CRI ≥80,CCT-6500K ,surge protection upto 4KV,Voltage Protection upto 400 volt,PF ≥ 0.9 suitable forbatten holder fitting complete all as specified and directed by Engr in charge.Note Warrenty on light should be of minimum 02 Years. |
| 140 | S & F of exhaust fan of white colour made of sturdy engineering PVC complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, noise level 40-45dB ,water resistant ,copper winding of sweep 250mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note :1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. complete all as specified and directed 2. Making suitable size of hole on wall for fixing the exhaust fan .3. 02 years guarantee to be provided by the contractor. |
| 141 | Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.Note : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 142 | Supplied & fixedMCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V including taking down completeall as directed by Engr-incharge. |
| 143 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 ampsrated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 144 | S & F MCB single pole,having rupturing 10KA,6 amps to 32 amps as ordered 240 Volts |
| 145 | S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered. |
| 146 | S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240/415 V 63 amps as ordered. |
| 147 | S & F of Inverter LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,inbuilt battery Back-up auto ON/OFF/Dimmer(Pre-programable), including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers completecomplete all as specified and directedNote :- 02 Year warranty on light minimum should be provided by contractor. |
| 148 | S & F in repair of manual changer switch in sheet steel enclosure four pole, 415volt, front handle operated of capacity 200 Amp complete, change over switch fixed in panels or on walls as per site requirement including taking down old UNSV change over switch any make and type all as specified and directed by EIC |
| 149 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including earth lead wire 4.0 mm dia as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 5 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete including taking down old U/S earthing.Note :- (i) Cost of earth lead and GI protection pipe up to a distance 7.5 metre shall be included inthe quoted rate. (ii )On testing after completion if the desired earth resistance less than 2 ohm is not obtained the earthing will be redone at no extra cost. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail