| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 50mtrs and earth filling in the depression/pit.)Girth from 300 mm to 600 mm |
| 3 | Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 50mtrs and earth filling in the depression/pit.)Girth from 600 mm to 900 mm |
| 4 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 5 | Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Ordinary rock |
| 6 | Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Hard rock (blasting prohibited) |
| 7 | Extra for every additional lift of 1.5 m or part thereof in (Ordinary or hard rock). |
| 8 | Filling with available excavated earth in trenches, plinth and side of foundation in building works with layers not exceeding 20cm in depth including consolidation of each layer by ramming, watering etc, all complete. |
| 9 | Sand filling in building works in layer not exceeding 20cum including watering, ramming etc, all complete. |
| 10 | Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.1:2:4 mix. (1 cement, 2 coarse sand, 4 graded stone aggregate of 20mm & down size) |
| 11 | Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.1:3:6 mix. (1 cement, 3 coarse sand, 6 stone aggregate of 20mm & down size |
| 12 | Providing and laying in position machine batched and machine mixed design mix M‐25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer‐in‐charge.(Note :‐ Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
| 13 | Extra for providing richer mixes at all floor levels.Note:‐ Excess/less cement over the specified cement content used is payable / recoverable separately.Providing M‐30gradeconcreteinsteadofM‐25 grade BMC/ RMC. (Note:‐ Cement content considered in M‐30 is @ 340 kg/cum) |
| 14 | Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete. |
| 15 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Beam, lintels, girders, brersumers and cantilevers. |
| 16 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Foundation, footings, base of column etc for mass concrete. |
| 17 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Floor slab, roof slab, landing, balcony and access platform. |
| 18 | Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Square columns |
| 19 | Providing and Laying damp proof coarse 40 mm thick with cement concrete 1:2:4 ( 1 cement, 2 Clean coarse sand, 4 graded stone aggregate 12.5 mm & nominal size) as per the direction of Engineer in Charge. |
| 20 | Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.‐in‐ charge includingcuring etc. all complete. |
| 21 | Providing and laying first class brick work in half brick thick in superstructure of standard size bricks with 1:4 cement mortar (1 cement and 4 course sand) including carriage of bricks up to work site, curing etc all complete |
| 22 | Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete.1:4 (1 cement: 4 fine sand |
| 23 | Providing and Laying 15mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete.External Surface inner side : 1:4 (1 cement: 4 fine sand). |
| 24 | Providing and Laying 20mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete. 1:6 (1 cement: 6 fine sand). |
| 25 | Providing and laying plaster of paris putty of 2mm thick over lastered surface to prepare the surface even and smooth all complete: |
| 26 | Providing and Providing and painting with plastic Emulsion paints two or more coats on New surface of required shade to give an even shade including brushing the surface clean of all dirt dust and smoothened by sand paper etc complete. |
| 27 | Providing and Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface. |
| 28 | Providing & applying priming coat with ready mixed Red oxide, Zinc chromate primer on steel/galvanized‐ Iron steel works i/c preparation of the surface complete |
| 29 | Providing fitting fixing Fibre Glass reinforced plastic door frames of cross section 90 x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. . The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Doorframe laminate shall be 2 mm thick and shall be fitted with suitable wooden blocks in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided at the bottom to steady the frame. |
| 30 | Providing fitting fixing Fibre Glass reinforced Polyester (FRP) Windows Shutter of cross section 75 mm x 30 mm. The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Window shutter laminate shall be 2 mm thick and shall be fitted with suitable wooden blocks. |
| 31 | Providing fitting fixing Fibre Glass reinforced polyester (FRP) Window frames of cross section 90 x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. . The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Door frame laminate shall be 2 mm thick and shall be fitted with suitable wooden blocks. |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 33 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 34 | Providing and fixing M.S grills in timber frames of windows with M.S flats with nuts, bolts, and smooth finishing of welded joints/surface with Grills weighing 8.00Kg/sqm as per the direction of Engineer ‐ in‐ Chargeall complete |
| 35 | Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial ply (both faces) including hinges with screws complete.30mm |
| 36 | Providing and fixing to existing door shutter 30 mm thick Glass Fibre Reinforced Polyester (FRP) paneled door shutter of required colour and approved brand and manufacture, made with fire‐retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden blocks of seasoned wood inside at required placed for fixing and fittings, cast monolitically with 5 mm thick FRP laminate for panels confirming to TADS 6: 1993 and / or IS 14856‐2000 including fixing to frames. |
| 37 | Providing and fixing Brass bright finished brass butt hinges with necessary screws etc. complete.150x31x4mm |
| 38 | Providing and fixing Brass bright finished brass butt hinges with necessary screws etc. complete.125x31x4mm |
| 39 | Providing, fitting and fixing. sliding door bolts with nuts and screws etc. complete.Size 300x16mm : Brass (bright Finish) |
| 40 | Providing, fitting and fixing. sliding door bolts with nuts and screws etc. complete.250x16mm Size : Brass (Bright Finish) |
| 41 | Providing and fixing tower bolts 300x10mm (Barrel type) with necessary screws etc complete : Brass (Bright Finish) |
| 42 | Providing and fixing tower bolts 250x10mm (Barrel type) with necessary screws etc complete. : Brass (Bright Finish) |
| 43 | Providing, fitting and fixing. handles 125mm size with necessary screws etc complete. : Brass (Bright Finish) |
| 44 | Providing, fitting and fixing. handles 100mm size with necessary screws etc complete. : Brass (Bright Finish) |
| 45 | Providing and fixing 100mm mortise lock with 6 levers and pair of handles with necessary screws etc complete. : Brass (B.F) |
| 46 | Providing and Laying white or colored glazed tiles of size 200mm x 300mm of plain/ normal prints colours (white, grey, ivory, platinum, cream, glacier white, summersand, beach, wood duro, melody, or equivalent) in skirting, risers of steps and Dados on 12mm thick cement plaster (1cement, 3coarsed sand) 1:3 bare and jointed with white cement slurry |
| 47 | Providing & Laying white or colored glazed vitrified tiles of Orient / Somani or equivalent colour in flooring, treads of steps landing etc laid on a bed of 15mm, cm 1:3 (1cement, 3coarse sand) finished with flush pointing with white cement slurry |
| 48 | roviding and Laying. 25mm thick kota stone slab flooring over 20mm thick 1:4 cm base laid and jointed with grey cement slurry mixPed with pigment to match the shade of the slab including cutting, rubbing and polishing complete. |
| 49 | Providing and Laying kota stone slabs 25mm thick in Risers of steps, skirting dado and walls laid on 12mm thick (average) thick base of c.m. 1:3 (1 cement, 3 coarse sand) and jointed with grey cement slurry mixed with pigments to match the shade of the slab including cutting, rubbing and polishing complete. |
| 50 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube |
| 51 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.: With 12 mm mild steel U beading |
| 52 | Providing, fitting and fixing white vitreous china pedestal (European type) water closet (W.C) pan with seat and lid, with C.P. brass hinges, 10ltr low level cistern with fittings and brackets 40mm flush bend, 20mm overflow pipe with specials, including Providing and painting and making good the wall and floors as required all complete: W.C. pan European Bidets standard CAT NO 30001 |
| 53 | Providing, fitting and fixing. white vitreous white china wash flat back basin with CI brackets, painted, 15mm CP brass pillar taps, CP brass chain with rubber plug, 32mm CP brass waste pipe, lead or PVC connection 32mm dia CP brass cap and unions, complete including cutting and making good the walls wherever required. HINDWAREOne wash basin with one pillar cock. : 45 cm x 30 cm |
| 54 | P/F stain less steel kitchen sink with CI brackets, CP brass chain with rubber plug 40mm CP brass waste, CP brass tap etc complete i/c the fittings, cuttings and making good the wall wherever required. : 610 x 450 x 200 mm. |
| 55 | Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. all complete:. |
| 56 | Providing, fitting and fixing Beveled gauge mirror of superior glass with 6mm A.C. sheets ground and fixed to timber cleats with CP screws, washer etc complete |
| 57 | Providing, fitting and fixing. of chromium plated soap dish with necessary screw etc all complete. |
| 58 | Providing, fitting and fixing towel rail of chromium plated brass complete with brackets fixed to the timber cleats, CP brass screws complete. : 600 x 20 mm |
| 59 | Providing, fitting and fixing towel ring of chromium plated brass complete with CP brass screw and timber cleats. |
| 60 | Providing and fixing M.S. or oxidized M.S. Hook and Eyes with complete set. : 150mm |
| 61 | Providing, Fitting and fixing PVC 32mm dia pipe complete with GI fittings and clamps including cuttings and making good the walls etc. on wallfor wash basin connector to main line |
| 62 | Providing, fitting and fixing soil, waste and vent pipes including testing etc complete.100 mm dia. PRINCE / SUPREME or equivalent soil pipe |
| 63 | Providing, fitting and fixing. bends of various types plain or a band with access door, insertion rubber washer 3mm thick bolts and nuts complete SCI or centrifugally cost spun sands pipes.100 mm dia. Supreme / Prince |
| 64 | Providing, fitting and fixing double equal junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100 x 100 x 100 x 100 mmSupreme / Prince |
| 65 | Providing and fixing 8mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer-in-charge. |
| 66 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.15 mm dia G I pipe |
| 67 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.20mm dia G I pipe |
| 68 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.25mm dia G I pipe |
| 69 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.32mm dia G I pipe |
| 70 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.40 mm dia G I pipe |
| 71 | Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.50 mm dia G I pipe |
| 72 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)BIB COCK15 MM DIA |
| 73 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)STOP COCK15 MM DIA (CONCEALED WORKS) |
| 74 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)ANGULAR STOP COCK15 MM DIA |
| 75 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)BIB COCK LONG BODY 15 MM DIA |
| 76 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)CONNECTING PIPE |
| 77 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)SHOWER ROSE WITH ARM |
| 78 | Providing and placing on terrace high density polyethylene water storage tank with man hole lid and suitable locking arrangement including making holes for inlet, out let and ball cock including testing etc. all complete: (Sintex or equivalent)500 LITERS CAPACITY |
| 79 | Providing, Fitting and fixing ball valve (Brass) of approved quality complete with high or low pressure with plastic floats: |
| 80 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self‐priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer‐in‐Charge. (Contech/Perma/Zydex/Chryso) |
| 81 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore. |
| 82 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour: 20mm nominal bore. Weighing not less than 40gms. |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore. |
| 84 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 85 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality: L D- 2.5 - Rectangular shape 600x450mm internal dimensions |
| 86 | Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 87 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 88 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe. |
| 89 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:100 mm diameter S.W. pipe. |
| 90 | Loading and unloading of stone boulder/stone/aggregates/sand/ kanker/moorum. |
| 91 | Loading and Unloading of Cement or Steel by Manual Means and stacking. |
| 92 | Cost of haulage excluding loading and unloading- Surfaced road:-Non-stock & stock materials |
| 93 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required.Group-A |
| 94 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required.Group-B |
| 95 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required.Group-C |
| 96 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 97 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire |
| 98 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire |
| 99 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 10.0 sq. mm + 1 X 10.0 sq. mm earth wire |
| 100 | Installation, testing and commissioning of pre-wired, fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm HR-FRLSH insulated, copper conductor, single core cable and earthing etc. as required. |
| 101 | Supply & Fixing of 250 Volt, 4 Ft. long 2100lm 18 Watt Single LED Tube Light fittings complete with all accessories incl. LED Tube.Flicker free, high efficiency and robust industrial batten family suitable for surface, wall and conduit mounting. |
| 102 | Power Consumption 9 W, Correlated Color Temperature (Nom) 6500 K, Luminous Flux 1000 lm, Luminous Efficacy (rated) (Nom) 110 lm/W Color rendering index (CRI) >80, Ingress protection code IP20 [Finger-protected], Mech. impact protection code IK02 [0.2 J standard], Surge Protection (Common/Differential) Surge protection level until 2.5 kV, Protection class IEC Safety class I - LED LUMINARIES. |
| 103 | Power Consumption 7 W, Correlated Color Temperature (Nom) 6500 K, Luminous Flux 1000 lm, Luminous Efficacy (rated) (Nom) 110 lm/W Color rendering index (CRI) >80, Ingress protection code IP20 [Finger-protected], Mech. impact protection code IK02 [0.2 J standard], Surge Protection (Common/Differential) Surge protection level until 2.5 kV, Protection class IEC Safety class I - BULK HEAD INDOOR TYPE LUMINARIES. |
| 104 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sqmm HR-FRLS insulated copper conductor, single core cable etc. |
| 105 | Supply of 1200mm sweep ceiling fan suitable for operation on 230V, 50 Hz AC supply, complete with down rod, rubber shackle, blades, condensor, canopies etc. complete as reauired but without regulator. |
| 106 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Two module) |
| 107 | Installation, testing and commissioning of Exhaust fan, including wiring with 1.5 sqmm HR-FRLSH insulated copper conductor, single core cable etc. |
| 108 | Supply of single phase, 250 mm sweep, 1400 rpm exhaust fan suitable for operation on 230V, 50 Hz AC supply, complete with blades, condensor, frame etc. as required |
| 109 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. |
| 110 | Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. |
| 111 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 112 | etc. as required. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection |
| 113 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 114 | Supplying, fixing, testing & commissioningof following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.1/2 Module (75mm X 75mm) |
| 115 | Supplying, fixing, testing & commissioningof following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mm X 75mm) |
| 116 | Supplying, fixing, testing & commissioningof following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.4 Module (125mm X 75mm) |
| 117 | Supply & earthing with G.I earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coak and salt as required. |
| 118 | Providing and fixing earth bus of 25 mm X 5 mm GI strip on surface for connections etc. as required. |
| 119 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/ cable as required. |
| 120 | Supply, fixing, testing and commissioning of integral flood (bracket light) fitting complete with 60 watt LED luminaries along with required Driver.Power Consumption 60 W, Correlated Color Temperature (Nom) 5700 K, Luminous Flux 8400 lm, Luminous Efficacy(rated) (Nom) 140 lm/W Color rendering index (CRI) >70, Luminaire light beam spread 130° x 88°, Optic type outdoor Distribution Symmetric Wide, Mounting device - Spigot for diameter 60 to 76 mm, IP66 [Dust penetration-protected, jet-proof], Mech. impact protection code IK10 [20 J vandal-resistant], Surge Protection (Common/Differential) 4/4 kV, Protection class IEC Safety class I |
| 121 | Supply, erection, testing & commissioning of 6 mtr long Octagonal Pole, (200X200)x12 mm thick base plate, complete with 1 Mtr long single arm bracket. Pole is comprising with pole box arrangement consisting with 1 no 6A DP MCB \"C\" curve of 10kA rated and pole earthing provision in the base plate and complete. |
| 122 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.12 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 123 | Supply of 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes.4 C X16 sq mm |
| 124 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 7.3.1 Upto 35 sq. mm |
| 125 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 7.5.1 Upto 35 sq. mm |
| 126 | Providing, laying following outer dia HDPE pipe of PE 100 grade, SDR - 17, PN - 8 in ground as required40 mm dia |
| 127 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq |
| 128 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq |
| 129 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 130 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 131 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powderpainted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4 + 12), Double door |
| 132 | Supplying and fixing following rating, four pole, 415 volts, C curve MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps |
| 133 | Supply and fixing of 5A to 32A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail