| 1 | Surface preparation to receive micro concrete by chipping to depth to max 75mm, cleaning removing the traces of dust, loose concrete etc. includind the cost of the labour charges, minor tools, etc complete. |
| 2 | Supplying preparing and priming the reinforcement steel with epoxy zinc. Primer or epoxy anti- corosive paint (Conforming to having IS/BIS Certification) including the cost of all materials labour minor tools, etc. |
| 3 | Supply and application of epxy concrete bonding, agent (conforming to and having BIS 6319 certification)and over cleaned and properly prepared old concrete surface to give good bonding between old and new concrete, including cost of all materials, minor tools etc. complete. |
| 4 | Supplying and fixing form work and shuttering to receive the micro concrete including cost of all materials all labour charges, minor tools etc. |
| 5 | Supplying, mixing and applying curing membrane or equivalent with water including cost of all materials all labour charges, minor tools etc. complete. |
| 6 | Supplying and applying high strength non shrink cementinous free flow concrete ( eith minimum 28 days flexural strength 50kg/sq.cm and compressive strength 500 kg/sq.cm as per BIS 4551-80) for above water level on site to enable completion of pouring in a continous operation. An approved grout concrete mixture of slow speed heavy duty drill and exact quantity of water as recommended should be poured into the vessel slowly and mix the same throughly in a forced action. The mix materials should be placed immediately to position foam work continously to an average thockness of 50mm without any gap including all materials and labour charges etc. complete. |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 8 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 9 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 10 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 11 | Of area 3 sq. metres and below |
| 12 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 13 | Asbestos Cement sheet |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 15 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 17 | Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 19 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 20 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, if nishing and reinforcement- All work up to plinth level : |
| 21 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived fromnatural sources: 3 graded stone aggregate 20 mm nominalsize derived from natural sources). |
| 22 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddoor/window/Ceosetory windows& other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ricehusk/wheathusk)andnontoxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/moistureproof andfireretardantandfixedin position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 23 | Frame size 65 x 100 mm |
| 24 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calciumcarbonateand naturalfibers (woodpowder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of requiredsize withnecessary fullbody threadedstar headed countersunkS.Sscrews,allasper directionof Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 25 | 35 mm thick |
| 26 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 27 | 300x16 mm |
| 28 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 29 | 200x10 mm |
| 30 | 150x10 mm |
| 31 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 32 | 125 mm |
| 33 | 100 mm |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 35 | Size of Tile 600x600 mm |
| 36 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 37 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 38 | Ridges plain (500 - 600mm) |
| 39 | 12 mm cement plaster of mix : |
| 40 | 1:4 (1 cement: 4 River sand) |
| 41 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : |
| 42 | Old work (one or more coats) |
| 43 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 44 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 45 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 46 | One or more coats on old work |
| 47 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 48 | One or more coats on old work |
| 49 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. |
| 50 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 51 | Kitchen sink without drain board |
| 52 | 610x510 mm bowl depth 200 mm |
| 53 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 54 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. |
| 55 | Providing and fixing brass bib cock of approved quality : |
| 56 | 15 mm nominal bore |
| 57 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 58 | 10 litre capacity - White |
| 59 | Providing and fixing soil, waste and vent pipes : |
| 60 | 100 mm dia |
| 61 | UPVC Pipe |
| 62 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 63 | 100 mm dia |
| 64 | UPVC Pipe |
| 65 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 66 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 67 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 68 | 100 mm diameter |
| 69 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 70 | Beyond 60 cm girth upto and including 120 cm girth |
| 71 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 72 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 73 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 74 | 6 mm thick Cement fiber board as per IS: 14862 |
| 75 | ELECTRICAL WORKS |
| 76 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 77 | Group C |
| 78 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 79 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 80 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 81 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 82 | Supplying and fixingSuitable PVC boxon surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 83 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin5/6 & 15/16amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 84 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 85 | Supplying of prewired LED tube light 20W/22W (MAKE INTENSO LXS BATTEN 4 FEET 20W) (Make: Havells/Polycab/Crompton) or equivalent to ISI Standarad. |
| 86 | Installation, testing and commissioning of pre-wired, LED FITINGof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 87 | Supplying of A.C. Ceiling fan(1200mm sweep 1 Star Ratting) USHA ENERGIA 50W suitable for operationon 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required.(Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard). |
| 88 | Supplying and fixing stepped type electronic fan regulator (Socket type)on the switch box including connectionsetc. as required.Make : anchor/polycab/havells etc or equvalent to ISI standard. |
| 89 | Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 90 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 91 | 6 way, Double door |
| 92 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 93 | Single Pole MCB |
| 94 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 95 | 40 Amps, 2 Pole Isolator |
| 96 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 97 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 98 | Supplying ofLED Lamp 15W bulb or lamp( (Make: Bajaj/ Havells /Usha /Orient/Crompton or equivalent to ISI standard) |
| 99 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 100 | Supplying and fixing of Wooden meter board of Size 10\" X 12\" for fixing of Energy meter or equivalent to ISI standarad. |