| 1 | Taking down cement plaster on brick/concrete surfaces of any description in any position incl racking out joints, hacking for key, scrubbing down with water etc and removing rubish off the premises, complete all as specified and directed. |
| 2 | M&L for brickwork with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed. |
| 3 | M&L for 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 4 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with water proofing compound on top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately as \"supply only\") |
| 5 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. |
| 6 | M&L for 5mm thick rendering in CM (1:3) on fair faces of ceiling surfaces, soffits of staircase, waste slab etc, finished even and smooth without using extra cement, complete all as specified and directed. |
| 7 | M&L for prepration of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over and including a coat 2mm thick wall care putty and prepration of putty surfaces even and smooth, complete all as specified and directed. |
| 8 | M & L for complete removal of existing treatment of walls surfaces applying two coats of oil bound distemper over and including 2mm thick wall care putty to obtain even and smooth surface including making good any undulations on the surfaces, complete all as specified and directed. |
| 9 | M&L for preparation of newly plastered surfaces on ceiling and applying three coats of white wash, complete all as specified and directed. |
| 10 | M&L for preparation of newly plastered surfaces of wall and applying two coats of 100% premium acrylic weather proof exterior emulsion paint, alkali & fungal resistance, approved colour and shade (pattern deep green/camouflage), over and including a primming coat of exterior emulsion primer as per manufacturer\"s instructions, complete all as specified and directed. |
| 11 | M&L for preparation old plastered surfaces of wall and applying two coats of 100% premium acrylic smooth exterior smooth emulsion paint alkali & fungal resistance, approved colour and shade (pattern deep green/camouflage), complete all as specified and directed. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site of work, complete all as specified and as directed. |
| 13 | S&F MS roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 290 (Gde E-165), complete all as specified and as directed. |
| 14 | M&L for mild steel framed work such as grill, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barrel iron doors, ladders framed balusters, walks railings, frame work of water tanks and similar work conforming to Fe-290 (Gde E-165), complete all as specified and directed. |
| 15 | S&F rolled mild steel in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc conforming to Fe- 290, (Gde E-165) including distance pieces, cleats etc, complete all as specified and directed. |
| 16 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide, zinc crome primer, complete all as specified and directed. |
| 17 | Dismantling of plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering, complete all as specifed and directed. |
| 18 | S&F pre painted galvalume aluminium zinc coating, GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 19 | S&F pre painted galvalume aluminium zinc coating, GI based plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall, vally/ridge etc, fixed with self tapping screws, complete all as specified and directed. |
| 20 | Taking out existing plaster and removing of debris to a distance exc. 100m and n. exc. 250m and cleaning roof surfaces to remove all loose dust etc., roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water using wire brush, brooming down and applying the following treatment all as directed in order of precedence as stated :(a) Brushing neat cement slury with 3.0 kg of cement per Sqm.(b) 15mm thick screed bed or bedding layer in CM (1:3) mixed with water proofing compound as permanufacturer instruction on existing roof surface true to level.(c) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm confirming to IS-3384.(d) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.50 Kgs per Sqm reinforced with non-woven polyester fabric weighing not less than 160gms per Sqm having softening point not less than 15°C, having tensile strength of 650 N/Sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N by torch application. Polymeric membrane shall be taken to a height of 30cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(e) Applying one coat of green weather coat exterior emulsion paint @ 0.11 Ltr/Sgm over APP membrane surface.Note:- (i) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions.(ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.(iii) APP based polymeric membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/1S 16532 2017.(iv) Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work.(v) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work.(vi) The work shall be executed through authorised applicators of original manufacturer only.(viI) WPC shall be measured and paid separately as supply only. |
| 21 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level), complete all as specified and directed. |
| 22 | M&L for 75mm thick PCC (1:3:6) type C- 2, (using 40mm graded crushed stone aggregate) as in sub-base, floors and pavings or plinth protection etc, finished even and smooth without using extra cement, complete all as specified and directed. |
| 23 | M&L for 40mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floors etc. finished even and smooth without using extra cement, complete all as specified and directed. |
| 24 | M&L for chequered cement concrete tiles 30cm x 30cm x 25cm thick set jointed and pointed in near cement slurry with pigment set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed in CM (1:6), complete all as specified and directed |
| 25 | Dismantling of old steel window/ventilator of any description, complete all as specified and directed |
| 26 | S & F in repair powder coated (minimum thickness of powder coating 15 micron) aluminium anodised door comprising of frame of size 101.60mm x 44.6mm x 2.4mm thick push/pull type glazed door shutter having top and bottom section of size 83 x 44.5 x 2.4mm and 100 x 44.5 x 2.4mm thick respectively, styles section of size 80 x 44.5 x 2.4mm thick and lock rail of size 100mm x 44.5mm x 2.4mm thick including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size including 5mm thick tinted sheet glass in both panel, hinges, mortice lock, stays & aluminium anodised handle of suitable size, etc, complete all as specified and directed. |
| 27 | S&F powder coated (minimum thickness of powder coating 15 micron) aluminium anodised sliding window shutter frame comprising of 3 track sliding window made out of aluminium extruded section of bottom frame of weight not less than 1.175 Kg/RM, top and side frame of weight not less than 0.423 Kg/RM, top and bottom rail of shutter of weight not less than 0.336 Kg/RM, in two panel and shutter with and including 5mm thick selected quality tinted glass and third one with and including stainless steel wire mesh and overall aluminium decogrill of size 100 x 100 x 8mm as approved by GE with standard aluminium channel out side, with and including handles, cleat glazing clips, special auto lock, dry set rubber gasket, complete all as specified and directed. |
| 28 | S&F powder coated (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate \"Z\" sections and other section of approved make conforming to IS-733 and IS-1285, fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions, i.e. at top bottom and sides with required EPDM rubber/neoprene gasket. aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, CP brass/stainless steel screws, complete all as specified and directed. |
| 29 | S&F aluminium (extruded section) body door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and directed. |
| 30 | S&F for 3mm thick wooden finishes ACP (aluminium composite panel) sheet in panels of aluminium frame including all nessessary fittings, complete all as specified and directed. |
| 31 | S&F 10mm thick toughened glass, as in partition, fixed to aluminium section, including cutting to shape, drilling holes, as required, complete all as specified and directed. |
| 32 | S&F false ceiling with powder coated exposed Gl grid suspension system(E-Grid T- 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600mm long, Cross Tee 1200rnm/600rmm long and Wall Angie. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600mm shall be placed perpendicular to the Cross Tee 1200mn iong to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 3 to 4mm dia GI wire from purlins/soffitincluding providing 4mm thick Fiber Cement Designer Board, should be placed in the grid module to form a false ceiling including dismantling of old unserviceable ceiling boards, any thickness including cover fillets, complete all as specified and directed |
| 33 | Dismantling of floor, hearth or wall tiles including cement mortar bedding (but not backing), removing serviceable tiles or stone and remvoing rubbish off the premises, complete all as specified and directed. |
| 34 | M&L for vitrified ceramic designed coloured tiles 10mm thick (square/ rectangular) area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 35 | All as per item No 34.00 here-in beforebut as in skirting/dado over and including rendering 10mm thick in CM (1:4) as backing coat to receive wall tiles, complete as specified and directed. |
| 36 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 37 | M&L glazed ceramic coloured tiles in vertical surface 350 x 250 x 7mm/450 x 300x 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM (1:4) as backing coat to receive wall tiles, complete all as specified and directed. |
| 38 | Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 39 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 40 | S&F CPVC pipe of size 16mm outer dia, SDR 11 & plain CPVC SDR 11 fittings complete, fixed on wall/ceiling or laid in floors with necessary saddle/clamps including all necessary fittings like elbow, tee, socket, reducer, etc. fixed with necessary solvent cement, complete all as specified and directed. |
| 41 | S&F CPVC pipe of size 20mm outer dia, SDR 11 & plain CPVC SDR 11 fittings complete, fixed on wall/ceiling or laid in floors with necessary saddle/clamps including all necessary fittings like elbow, tee, socket, reducer, etc. fixed with necessary solvent cement, complete all as specified and directed. |
| 42 | M&L for cutting chases on wall surface, pinning in making good to facing where required and pointing in CM (1:3) to ends to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills , sunshades, shelves, lintesl etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good as per existing surface cutting not exc 10cm girth in brick walls, complete all as specified and directed. |
| 43 | S&F 15mm bore bib taps, cast copper alloy, chromium plated, two in one, with crutch or butterfly handle, screwed down, screwed for iron pipe, compelete all as specified and directed. |
| 44 | S&F 600mm x 450mm bevelled edge mirror made of selected quality sheet glass not less than 5.5mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 45 | S&F vitreous china wash hand basin, oval shape,pastel, flat back of size 580 x 450mm including chain, plug & procelain stopper and pinning in ends of brackets etc, complete all as specified and directed. |
| 46 | S&F vitreous china EWC water closet pan, white and including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe with seat and cover and flushing cistern & flush pipe including making good distrubedsurfaces/damaged, complete all as specified and as directed. |
| 47 | S & F in repair vitreous china urinal, bowl type flat back of size 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including urinal spreader, providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plug with and including 60mm long brass screws, pointing around urinal back, complete all as specified and directed. |
| 48 | S&F 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe, complete all as specified and directed. |
| 49 | S&F in repair 32mm bore, waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed. |
| 50 | S & F in repair 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends, complete all as specified and directed. |
| 51 | S&F in repairs 15mm bore bib taps, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule, compelete all as specified and directed. |
| 52 | S&F in repair 15mm bore, fancy type, chromium plated, stop valves, concealed type, with long shank and cup, cast copper alloy screwed down high pressure screwed bothends for iron pipe or union, complete all as specified and directed. |
| 53 | S&F in repair pillar tap, 15mm bore, capstan heads, chromium plated, screweddown high pressure with or without lettered “hot’ or “ cold” with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed. |
| 54 | S&F health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed. |
| 55 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges, compelete all as specified and directed. |
| 56 | S&F in repair PTMT towel ring fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight - 90 gms), complete all as specified and directed |
| 57 | S & F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. |
| 58 | S&F 150mm grating round of PTMT (minimum wight - 100 gms), complete all as specified and as directed. |
| 59 | S&F 100m dia cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate), complete all as specified and as directed. |
| 60 | S&F 110mm bore, PVC (SWR), single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 61 | S&F 110mm bore, PVC (SWR) bends of any radius, complete all as specified and directed. |
| 62 | S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket including one single pole MCB 20 Amp, concealed in wall, complete all as specified and directed. |
| 63 | M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 4 Sqmm, 1100 Volts grade, FRLSH type, drawn in and including heavy duty rigid PVC concealed conduit (ISI marked) not less than 20mm dia with fixing accessoriesincluding 4 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old sub-main wiring of any size,, complete all as specified and directed.Note: (i) Two runs of single core cable with one run of earth continuity conductor including PVC conduit and its accessories shall be measured and paid as one length of sub main.(ii) Cutting chases for conduit and sinking of boxes and making good to wall floors etc shall deemed to be including in the unit quoted rate. |
| 64 | Supply, installation, testing and commissioning of splittype Air conditioning units 1.5 TR indoor and outdoor complete with cordless remote control unit and with 5 star rated/ BLDC type compressor unit with non CFC refrigerant, auto swing, LED display, noise level not more than 42 DB function, including remote, comlete with all piping arrangement etc, complete all as specified and directed. Note:(i) Condensate drain pipe of best quality to be provided and fixed in suitable manner till ground level/max up to6.0 Mtr fixed on wall/floor/ceiling and unit quoted rate shall deemed to be included for the provision of same.(ii) The quoted rate also includes necessary fixing arragement for indoor and outdoor units and copper tubing upto 6.00 mtr length, brazing, welding including insulation, complete charging of refrigerator gas upto required level and filling the cavities on wall, setting of grill alignment. |
| 65 | S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with ooutput voltage stabilizied at 230 V with accuaracy of + 2.5% can operate upto 12 Amp and above capacity 15 Amp of capacity upto 5 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. |
| 66 | Taking down the split/window AC unit from existing position from any hight of capacity 1.5/2.0 TR of any make, deposited to AGE E/M store, complete all as specified and directed. |
| 67 | Refixing of split type AC of capacity 1.5 to 2 TR,by fixing the indoor and outdoor unit in position including connection with replacement of copper tubing upto 3.0 mtrs length brazing, welding including insulation charging ofrefrigeratnt gas upto required level and filling the cavities on wall, setting of grills alignment including testing & commissioning, complete all as specified and directed. |
| 68 | Note: An amount of Rs.65,798.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 69 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |