| Sl. No. | Item Description |
| 1 | Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcements as per coplte satisfaction of Engr in Charge by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris within owners premises including all plant and machineries. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed. HSE Guidelines : Recommended to wear tightfitting,dust-resistant goggles and mask during breaking and surface grinding works etc. |
| 2 | M & L for Polymer modified Mortar-Patch repair (in 3 layaers) (Up to Grade M45) Providing and laying Renderoc SP 40- shrinkage controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength(BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength(BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Typical application inclues mixing entire bag with clean water about 4.25L to 4.5 L, mixed in suitable container with heavy duty slow speed mixer machine to achieve uniform lump free mortar consistency, placing and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles and mask if airborne dust is generated, wear protective gloves, Wear appropriate clothing to prevent any possibility of skin contact. |
| 3 | M&L Drilling of hole of suitable dia and length - as instructed by Engg In charge, in all structural memebers RCC, and other members, in any position, orientation etc. for enabling of insertion of incl but ot limited to Shear Connectors, extra bars, main bars, MS /TS Dowel Pins etc. complete al as specified and directed by Engg In Charge. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves, wear appropriate clothing to prevent any possibility of skin contact. |
| 4 | M & L for Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover Reebaklens RR- Rust remover, cleaning and etching agent supplied in 1/2, 1 and 5 Litre containers, having Specific Gravity 1.16 - 1.22 @ 25°C. Reebaklens RR cleaning agent is a combination of acid based material, corrosion inhibitors and dispersing agents and is supplied as a clear green solution.Application of Reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours followed by cleaning the surface with wire brush and washing surface with fresh water as required to exposed reinforcement bars complete as specified.Note : Rates quoted for all items should include working upto 12m height including all necessary scaffolding , staging etccomplete all as specified and as directed.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. |
| 5 | M&L M & L for Providing & applying inhibition coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Nitozinc Primer- Two component epoxy zincrich primer supplied in 1 and 5 Litre pack, two component system based on metallic zinc and epoxy resin which on mixing gives a grey coloured liquid. An Anti corrosive coat contents Active \"Zinc-rich\" system which combats corrosion by electro chemical means. having specific gravity of 1.75, Adhesive bond strength > 1.5 N/mm2 Solid content- 60 %, 40 microns DFT, Fully dry/Recoatable- 45 minutes to 1 hour.Typical application includes surface preparations by cleaning steel surface to a bright condition paying particular attention to the back of exposed steel bars, mixed two components slow speed heavy duty drill fitted with a paddle, applying unbroken coat with suitable brush and allow to dry, after 30 mins apply second coat to ensure complete cover to exposed steel/ rebar etc complete. Total Dry film thickness is 40 microns. HSE Guidelines : Nitozinc Primer and Nitofl or Sol should not come in contact with the skin and eyes, or be swallowed. Adequate ventilation should be ensured and inhalation of vapours should be avoided. suitable protective clothing, gloves and eye protection shall be worn. If working in confined areas, suitable respiratory protective equipment must be used. The use of barrier creams, provide additional skin protection. Incase of contact with skin, it shall be rinsed with plenty of water, then cleansed with soap and water. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed. |
| 6 | M & L forCRS steel bars, as main bars, shear connectors etc.-Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement (using tack welding at suitable intervals) which was reduced to 20 % or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55- Styrene free vinyl-ester resin based cartridge system for anchoring reinforcement supplied in 300 ml cartidge with a single mixer nozzle, application inclueds drilling hole close to old reinforcement bar with suitable drill (Drillig of hole to be paid seperatly ) as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete as directed by EIC.(i) for 8mm dia (min embedment depth 80mm) (ii) for 10mm dia(min embedment depth 90mm) (iii) for 12 mm dia ( min embedment depth 110 mm) (iv) for 16 mm dia ( min embedment depth 125 mm) complete all as specified and as directed. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. |
| 7 | M & L for Epoxy Bond Coat Providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP- Epoxy resin concrete bonding agent supplied in 1/2, 1 and 4 Litre packs, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C, High bond strenght High bond strength : Bond strength is more than the tensile strength of good quality concrete, Barrier coat : Acts as a ‘barrier coat’ to the migration of chloride ions from host concrete. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Typical application includes cleaning all loose dust, dirt, grease from host concrete surface by suitable means, mixing both components of bond coat by heavy duty slow speed mixer until a uniform consistency, apply unbroken coat of Nitobond EP with stiff brush covering complete area of patch repair before placing mortar or micro concrete. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Barrier creams provide additional skin protection. Do not smoke during use. Maintaine ample ventilation. If contact wiith the resin occurs, wash immediately with a strong detergent or a resin removing cream. Eye contamination must be immediatelywashed with plenty of water and medical treatment sought complete all as specified. |
| 8 | M & L for Polymer modified Micro-concrete (upto Grade M50) Providing all scaffolding and formwork and applying Renderoc RG- polymer modified micro-concrete supplied in 25 kg moisture resistant bag should possess following properties when mixed with clean water at w:p ratio 0.16, such as compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days, Young’s modulus-25 kN/mm2, Expansion characteristics (ASTM C827 - 1987)-Unrestrained expansion 1 to 4 %,Pressure to restrain Plastic Expansion-Approx. 0.004 N/mm2,Thermal Conductivity – 1.5 W/m ̊C, Fire rating (EN 1504 cl 5.5)- Class A1, Fresh wet density (Mixed density @27°C)- 2100 - 2200 kg/m3. Typical application inclued mixing whole bag with clean water about 4 litres, mixing in suitable container with heavy duty slow speed mixer machine to produce uniform, free flowing mix, pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engr-in-charge.Note : Rates quoted foritems should include working upto 14m height including all necessary scaffolding , staging etc HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. |
| 9 | M&L for special treatment to sunken portion (including necessary dismantling/demolition of tiles , plain cement concrete top and botom and lean concrete.An application of 25mm to 50mm plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) to maintain slope, finishing the surface even and fair to receive10mm thick plaster in CM 1:4 with WPC liquid complast 421 and applying one coat each of Nitoproof 100 & Nitoproof 120 on plastered surface. Rendering again 10mm thk plast in CM 1:4 mixed with complast 421 in sunken portion of WC as base for tiling , CI pipe joint shall be filled including filling of lean concrete in 1:4:8type D2 (using 40mm graded stone aggregat) complete all as specified and directed by Engr-In-Charge. |
| 10 | Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for plain cement concrete nominal mix 1:3:6type C1 using 20mm graded stone aggregate as in pre-cast cement concrete block masonry with solid blocks,exc.10 cm in width and setting in mortar 1:6 complete all as specified anddirected by Engineer-in-Charge. |
| 12 | M&L for plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.50 metres clear span, steps, seismic and other similar bands, coping, bed plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating, and use of form work (straight or curved), complete all as specified and as directed by the Engineer-in-Charge. |
| 13 | Taking down cement plaster, of any description on brick or stone or cement concrete walls/ceiling including raking out joints, hacking for key, scrubbing down with water, complete all as specified and as directed by the Engineer-in-Charge. |
| 14 | M&L for rendering 15mm thick on fair face of brick work or concrete surface in cement mortar 1:4 by using water proofing compound as per manufacturer instructionfinishing surfaces even and smoothcomplete all as specified and directed by the Engineer-in-Charge. Note:- Water proofing compound will be measured and paid separately. |
| 15 | M&L for rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar 1:6, finishing surfaces even and smooth,complete all as specified and directed by the Engineer-in-Charge. |
| 16 | M&L for rendering 5mm thick onconcrete surface of ceiling in cement mortar 1:3 , finishing surfaces even and smooth,complete all as specified and directed by the Engineer-in-Charge. |
| 17 | M&L for preparation of surface plastered or unplastered new plastered surface of wall and applyingFinishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), as in all as specified and as directed by Engineer-in-charge. |
| 18 | M&L for preparation of newly plastered surface of wall and applying two coat of OBD over a coat primer on walls with plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth completeall as specified and as directed by Engineer-in-charge. |
| 19 | M&L for preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling all complete all as specified. |
| 20 | M&L for preparation of surface plastered or unplastered old surface of wall and applyingFinishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed by Engineer-in-charge |
| 21 | M & L for preparaingplastered or unplastered surfaces of old walls including Washing, rubbing down and stopping of old painted surfaces and applying two coat of OBD on walls over 1mm thick wall care putty surface to prepare the surface even and smooth all as specified and as directed by Engineer-in-charge. |
| 22 | M & L for Preparation of old plastered surface of ceiling and applying two coat of white wash complete all as specified. |
| 23 | Taking down chowkat or frames with shutters (without taking off shutters from the frames)area n.exc 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) , complete all as specifiedand directed by the Engineer-in-Charge. |
| 24 | Taking down chowkat or frames with shutters (without taking off shutters from the frames)exc. 1.5 Sqm but n.exc 4 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost), complete all as specified and as directed by the Engineer-in-Charge. |
| 25 | Taking down shuttersof any description n exc 1 sqm in each panel complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Taking down shutters but exc 1 sq. m and n exc 2 sq. m each each complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F plain, solid straight chowkats,and frames, made of 2nd class hard wood , wroughtframed rebated on the solid, rounded or chamfered put togetherwith glue, pinned at joints supplied and fixed , complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | S&F plain framed , panelled shutters (any numbers of panels), 35mm thick, made of 2ndclass soft wood (, with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied & fitted to chowkats as per IS : 1003 (Part-I), complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | S&F glazed and skeleton shutters, 35mm thick, made of 2ndclass hard woodopen rebated and prepared to receive glass, gauze, etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.23(a) for doors etc are provided with stiles and rails, complete all as specified and as directed by the Engineer-in-Charge. |
| 30 | S&F 25mm thick second class hard wood plain framed panelled shutters [any numbers of panels] with panels of timber flat on both side [feather edged] or of veneered particle board medium density, wood particle board with commercial face veneerscomplete all as specified and as directed by the Engineer-in-Charge. |
| 31 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge. |
| 33 | S&Faluminium anodized barrel tower bolt extruded section and fixed 150 mm long complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specifed. |
| 35 | S&F in repair extruded aluminium alloy handles 150 mm fabricated type, anodised complete all as specifed. |
| 36 | S&F mild steel Butt hinges medium weight ,colled rolled100mm complete all as specifed. |
| 37 | S&Faluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminum alloy and fixed, 250 mm long, complete all as specified and directed by the Engineer-in-Charge. |
| 38 | S&F floor door stopper 140mm length of aluminium alloy body and tongue with hard drawn steel spring complete all as specified and directed by Engr-in-Charge. |
| 39 | S&Fin repair aluminium anodized barrel tower bolt extruded section and fixed 150 mm long complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F in repairextruded aluminium alloy handles 100mm fabricated type, anodised complete all as specifed. |
| 41 | S&Fin repair aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminum alloy and fixed, 250 mm long, complete all as specified and directed by the Engineer-in-Charge. |
| 42 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and and directed byEngineer-in-charge. |
| 43 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and directed byEngineer-in-charge. |
| 44 | S&Fsheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-charge. |
| 45 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by the Engineer-in-Charge. |
| 46 | Hacking out old broken glass (any thickness, size, quality or description) from wooden, metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed by Engineer-in-charge. |
| 47 | S&Fsheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-charge |
| 48 | S&F for aluminum grill made of high grade aluminum alloy section with powder coated for corrosion resistance. The grill designed with precise spacing and bar thickness as per manufactures instructions, cutomised design colors as specified and directed. |
| 49 | Dismantling wrought iron work/mild steel of any description as in door / window frame and vertical poles complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | Demolition of reinforced concrete cast in situ as in roofs, floors (other than ground floors) at any height includingall arrangements for staging etc, beams, staircases, landing, chajjas and similar suspended work reinforcement cut to facilitate demolition complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | Cutting channels, groves orrebates n exc 15cm girth, andtrimmingsurfacecomplete all as specified and as directed by the Engineer-in-Charge. |
| 52 | M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by the Engineer-in-Charge. |
| 53 | S&F 11 to 15 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with ashers and one hexagonal or square nut, exc 5cm long N exc 10 cmcomplete all as specified and as directed by the Engineer-in-Charge. |
| 54 | S&F 0.50mm thick prepainted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa minium, yeiled strength as in roof covering/cladding to wall, it shall be coated with hot dip alloy of 55% aluminium, 43.5% zinc, 1.5% silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating as specified and shall be fixed with hot dip galvanised, seld drilling and self tapping screws neoprened and EDPM washers as in roof covering, complete all as specified and directed. |
| 55 | S&F 0.50mm thick prepainted galvalume aluminum zinc coating GI based plan steel sheet of an colour having tensile strength of 550 Mpa minium, yeiled strength as in ridge, hips, valley gutters, it shall be coated with hot dip alloy of 55% aluminium, 43.5% zinc, 1.5% silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating as specified and shall be fixed with hot dip galvanised, seld drilling and self tapping screws neoprened and EDPM washers as in roof covering, complete all as specified and directed. |
| 56 | M&L preparation of newly steel surface of any description over 10cm width or girth not otherwisw describedtwo coat of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 57 | M&L cement concrete 1:4:8 type D2(using 40mm graded stone aggregate ) as in foundation,filling and mass concrete complete all as specified. |
| 58 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mmthick AC building board or commercial plywood and fixed to wooden plugs withchromium plated brass screws and cup complete all as specified and directed by Engr-in-Charge. |
| 59 | Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 60 | Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 61 | S&F 15mm bore GI tubing medium grade fitting complete to wall and ceiling or laid in floor complete all as specifed and directed. |
| 62 | S&F 20mm bore GI tubing medium grade fitting complete to wall and ceiling or laid in floor complete all as specifed and directed. |
| 63 | Refixing 15mm old GItubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed. |
| 64 | Refixing 20mm old GItubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed. |
| 65 | S&F in repairPillar taps 15mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed chromium plate fancy type complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F in repair 15mm Stop/angle valves, fancy type, chromium plated cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed by Engr-in-Charge. |
| 67 | S&F PVC (SWR) pipes, 110 mm dia ,single socketed in any length with rubber ring jointsfixed to walls complete all as specified as directed by engineer-in-charge. |
| 68 | S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified as directed by engineer-in-charge. |
| 69 | S&F in replacement vitreous china wash down water closet pan (pedestal pattern) with plastic water closet seat cover closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging divice (excluding flusing cistern and flush pipe), complete all as specified and directed. |
| 70 | S&F in replacement 10 Litres capacity PVC valveless syphonic action flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32mm dia, complete all as specified and directed. |
| 71 | S&F in replacement vitreous china wash hand basin of size 550mm X 400mm, white, flat back excluding taps but including mild steel brackets of suitable size and 32mm dia CP waste coupling, complete all as specified and directed. |
| 72 | S&F in repairs bib taps CP Brass fancy type long shank with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia complete all as specified and directed by Engr-in-Charge. |
| 73 | S&F in repair Chromium plated shower roses 125mm size, including fixing to steel pipe or union complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | S&F in replacement health faucet (ABS body) mild steel chromium plated, suitable for 15mm dia pipe with 1.25mtr long flexible tube and ABS wall hook including making connection and fixed in position, complete all as specified and directed. |
| 75 | S&F PVC(SWR) floor trap,plain with gratings incl jointing with solvent cement 75mm dia outlet complete all as specified and directed by Engr-in-Charge. |
| 76 | S&F Grating doom 10mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F in repairsPVC connections 15mm dia with brass nut on both ends and washers 450mm long all as specified and directed by Engr-in-Charge. |
| 78 | Dismantiling of floor hearth or wall tiling including cement mortar bedding (not backing ) removing serviceable tiles to store and rubbish of the premises, complete all as specified and directed. |
| 79 | M&L for vetrified ceramic tiles DarkShade/Double charged/ ultracharged 10mm thick(square/rectangle) polished area of each tiles not exc 0.36 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 80 | M&L for coloured glazed ceramic tiles (350x250x7mm/450x350x7mm)thick on verticle surfacesset and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 10 mm thick cement plaster in CM 1:4, complete all as specified and directed. |
| 81 | M&L for non skid ceramic coloured tiles 7 to 8mm thick 1st quality (square/rectangular) area of each exc 0.18 sqm but n exc 0.38sqmas in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface and over and incl screed bed or bedding layer of mortar 15mm thick laying floor finished in CM 1:6, complete all as specified and directed. |
| 82 | M&L for vetrified ceramic tiles DarkShade/Double charged/ ultracharged 10mm thick(square/rectangle) polished area of each tiles not exc 0.36 sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plasterin CM 1:4 , complete all as specified and directed. |
| 83 | Demolition of Stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engr-In-Charge. |
| 84 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finished, complete all as specified and directed. |
| 85 | M&L 20mm Granie (of any type) work( table rubbed and polished) in steps, jambs , pillars, window cills, cooking platforms, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete all as spd and directed. |
| 86 | Dismantiling of water tanks of capacity exc 250 & n exc 500 ltrs incl all necessary fittings, complete all as specified and directed. |
| 87 | S&F 500 ltrs PVC rotational moulded polyethylene water storage tanks triple layer made (cylindrical vertical with closed top ) hoisted and fixed in position all as spd in SSR part-Icomplete all as specified and as directed by the Engineer-in-Charge. |
| 88 | S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall orncluding fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge. |
| 89 | S&F in repair20mm dia drapery curtain rod/ Harrison rails of anodised aluminium alloy complete with MS brackets golden colour rings and sode caps fixed in position by drilling holes complete all as specified and as directed by the Engineer-in-Charge. |
| 90 | Taking down existing roof treatment, roughening surfaces of old concrete floor/roof by picking sweeping clean and washing down with water to remove dust etc and brushing with neat cement slurry @ 3 Kg of cement per sqm complete all as specified. |
| 91 | M&L for 25mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate)as in roof padding, roof kerbs, mud stops, rounded or chamfered on edges complete all as specified and as directed by the Engineer-in-Charge. |
| 92 | M&L for rendering 10mm thick on fair face of brick work or concrete surface in cement mortar 1:4 by using water proofing compound as per manufacturer instructionfinishing surfaces even and smoothcomplete all as specified and directed by the Engineer-in-Charge. Note:- Water proofing compound will be measured and paid separately. |
| 93 | Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment for:-(a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces completeall as specified. (b)Apply APP plastomeric bitumen based mineral finished water proofing membranepolyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT.(c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified. |
| 94 | M&Lfor opening out cracks, removing the loose material andFilling with Dr Fixit Crack -X shrinkfreeall as specified and directed by Engr-In-Charge. |
| 95 | M&L for preparation of oldpainted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint ocomplete all as specified and as directed by Engr-in charge. |
| 96 | Demolition of cement concrete un reinforced in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including disposal of unserviceable materials,debris and rubbish to a distance not exceeding 100 metre, complete all as specified and as directed by the Engineer-in-Charge. |
| 97 | M&L for 75mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in plinth protection / path, finished the surface even and smooth without using extra cement and joints shall be filled with mixture of bitumen and sand (1:3) by wight, complete all as specified and directed. |
| 98 | M&L providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing andweeping extra sand complete all as specified and as directed by the Engineer-in-Charge. |
| 99 | M&L for coloured chequered cement concrete tiles 30cmx30cmx25mm thick as in path etc. set and jointed with grey cement and pigments as in floors and over and incl screed bed or bedding layer of mortar 15mm thick laying floor finished in CM 1:6 complete all as specified and directed. |
| 100 | Supply only liquid water proofing compound. |
| 101 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, light fittings, MCB DBs,out let boxes etc.removing material for taking credit and making good disturbed surfaces of walls, floors, ceilings etc,complete all as specified and as directed by Engr-in-charge. |
| 102 | M&L for consealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drawn through PVC conduit of suitable sizeheavy grade ISI marked including necessary conduit accessories, sunken type pressed steel terminal boxes with plastic laminated sheet of approved shade 3mm thick including 1.5 mm PVC insulated flame retardant copper conductor as in continious earth wire ,complete all as specified and as directed by Engr-in-charge. for the following as given below:- |
| 103 | One Light/ceiling fan & exhaust fan point controlled by one switch. |
| 104 | One Bell point controlled by one switch. |
| 105 | One 3 pin 5 Amps socket out let on independent board. |
| 106 | One 3 pin 5 Amps socket out let on same board. |
| 107 | -Ditto- all as per item No 102 here-in-before but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board. |
| 108 | S&F switch piano flush button single pole one way 5 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge. |
| 109 | S&F Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge. |
| 110 | S&F switch piano flush button single pole one way 15 Amps, 250 V,complete all as specified and as directed by Engr-in-charge. |
| 111 | S&F socketoutlet 2 in 1,3 pin, 5A flush type 220 V,complete all as specified and as directed by Engr-in-charge. |
| 112 | S&F socketoutlet 2 in 1,6 pin, 5/15Amps flush type 220 V,complete all as specified and as directed by Engr-in-charge. |
| 113 | S&F bell buzzer, Ding Dong AC 230 volt single pole,complete all as specified and as directed by Engr-in-charge. |
| 114 | S&F fan regulator Electronic type step type for 400 watts ,complete all as specified and as directed by Engr-in-charge. |
| 115 | S&F Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals. ,complete all as specified and as directed by Engr-in-charge. |
| 116 | S&Fin repair , lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting,complete all as specified and as directed by Engr-in-charge. |
| 117 | S&F S&F in replacement of Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge. Make: Havells/Wipro/Bajaj/C&S/Philips |
| 118 | M&L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burrieddirectly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing. |
| 119 | S&F in replacement of LED bulb 5/7/9 watt, 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge. |
| 120 | Taking downthe ceilling fan /Exhaust fan from ceilling,wall,cleaning the dust,drit ,greashing,servicing ,repairing and refixing the original position ,complete all as specified and as directed by Engr-in-charge. Note:- Necessary spare for repairing will be measured and paid in respective items. |
| 121 | S&F factory made sheet metal enclosure double door 415 volts ,AC TPN vertical distribution board painted with epoxy based powder coated suitable for mounting MCCB as incommer of rating upto 160 amps FP 16-36 KA and MCB SP/TP as outgoing and complete withcopperBus bars, 200A, 415V Netural links,blanking plates, double door 4 way, with and includingtop and bottom removable gland with IP 43 protectionand electrically connecting up ,complete all as specified and as directed by Engr-in-charge. |
| 122 | S&F MCCB FP 4 pole 100 Amps415volts 50 HZ having 16 KA,complete all as specified and as directed by Engr-in-charge. |
| 123 | S&F in repairs MCB distribution board SPN 8 way 240 volts, double door withIP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed. |
| 124 | S&F in repair MCB SPN 32 Amps 10 KA, \"C\" series, 240 volts complete all as specified and directed. |
| 125 | S&F MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KA,complete all as specified and as directed by Engr-in-charge. |
| 126 | Excavation in trenches, not exceeding 1.5m wide and n.exc 10 sqm on plan and n.exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed. |
| 127 | Returning filling in including spreading levelling, watering & well ramming in layers not exceeding 25 cm in soil.complete all as specified and as directed. |
| 128 | Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and as directed. |
| 129 | Supply, spreading in trenches fine dry river sand for cable protection and removing down getting by hand complete all as specified and as directed. |
| 130 | Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and as directed. |
| 131 | Supply & laying XLPE insulated, screened, PVC bedded, galvanizedsteel strip or wire armoured heavy duty electric power cable of size 16 Sqmm x 4 core with aluminum conductor, 1100 V grade complete all as directed by Engr-In-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail