| 1 | For shutter of doors, windows & ventilators including providing and fixing hinges. pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required. (Fittings shall be paid for separately) |
| 2 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 3 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neorene gasket etc complete as per the architecutral drawings and the directions of Engineer in-charge. (Cost of aluminium snap beading shall be paid in basic items. |
| 4 | With float glass panes of 5.00mm thickness (weight not less that 12.5 kg/sqm) |
| 5 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 6 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embossed on the body, door weight upto 36 kg to 80kgand door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. Complete |
| 7 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. |
| 8 | 250 x 16mm |
| 9 | Providing and fixing aluminum tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 10 | 250 x 10 mm |
| 11 | Providing and fixing aluminium handing floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws. Complete. |
| 12 | Twin rubber stopper |
| 13 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 14 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 15 | Providing and fixing 12 mm thick pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge. |
| 16 | Pre-laminated particle board with decorative lamination on both sides |
| 17 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 18 | 10 x 80mm |
| 19 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 20 | 10 x 120mm |
| 21 | Sliding roller for making sliding arrangement of aluminium doors |
| 22 | Steel work welded in built up sections / framed work including cutting, hoisting, fixing in position and aplying a priming coat of approved steel primer using structural steel etc. as required. |
| 23 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 24 | Painting with synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade |
| 25 | Two or more coats on new work over an under cpat pf suitable shade with ordinary paint of approved brand and manufacturer |
| 26 | Providing and laying 50mm thick coloured IPS flooring with metallic concrete hardener topping, laid in panels of size 1m x 1m, including base layer (under layer): 38mm thick cement concrete 1:1:2 (1 cement: 1 coarse sand: 2 graded stone aggregate of 10mm nominal size) by volume.Top layer: 12mm thick coloured IPS flooring with metallic concrete hardener in the proportion of 1:2 (1 part cement hardener mic : 2 parts graded stone aggregate of 6mm nominal size) by colume. Metallic floor hardening compound of approved make shall be mixed with cement in the ratio of 4:1 (4 parts cement : 1 part metallic hardener) by weight along with addition of approved oxide pigment @ 2% to 4% by weight of cement to achieve the desired shade.The item shall include providing and applying cement slurry, finishing the surface with anti-skid texture, rounding of edges, inserting glass strips, making grooves, curing for a minimum period of 07 days and completing the flooring and skirting in all respects as per CPWD specifications and as directed by the Engineer-in-charge. |
| 27 | Electrical Works |
| 28 | Supplying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage 1100 volts grade as per IS 7098 |
| 29 | 16 sqmm (4 core) |
| 30 | Laying of one no. PVC sheated/XLPE power cable of 1.1kv grade of follwing size onwall surface as required |
| 31 | upto 35 sq. mm |
| 32 | Supplying and making indoor termination wirth brasscompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cableof 1.1 KV grade as required. |
| 33 | 2 x 16 sq. mm |
| 34 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductors single core cable in surface / recessed steel conduit , with piano type switch , phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor sinbgle core cable etc. as required. |
| 35 | Group C |
| 36 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 37 | 2 X 1.5 sqmm+ 1 X1.5 sqmm earth wire |
| 38 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 39 | Wiring for light/power plug with 2 x 4 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit along with 1 no. 4 sq. mm FRLSPVC insulated copper conductor single core cable for loop earthing as required. |
| 40 | Supplying and fixing following way Horizontal type three pole and neutral sheet steel , MCBdistribution board , 415 V on surface /recess complete with tinned copper bus bar , earth bar , din bar , interconnectionz , powder painted including earthing etc. as required |
| 41 | 6 way (4+18) , Double door |
| 42 | Supplying and fixing 5A to 32A rating ,240/415V , 10KA , C curve , miniature circuit breaker suitable for inductive load of following poles in the exsiting MCB DB complete with connection testing and commissioning etc as required. |
| 43 | TPN 63 A |
| 44 | Single pole 16 A |
| 45 | DP 63 amp |
| 46 | Supplying and fixing following rating double pole (single phase & neutral) , 415 v residual current circuit breaker RCCB having a senstivity current 30A in the existing MCB DB complete with connection, testing , commissioning etc as required |
| 47 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 48 | 5 / 6 ampswitch |
| 49 | 6 Pin15/16 amp socket outlet |
| 50 | 15 / 16 ampswitch |
| 51 | 3 Pin5/6 amp socket outlet |
| 52 | Supplying and fixingfollowingmodular base and cover plate on existing modularmetal box etc as required. |
| 53 | 6 module |
| 54 | Supplying and fixingfolowing sizes/modules,GI box along with modular base and cover plate for modular switches in recess etc |
| 55 | 6 module (200 mm x 75 mm) |
| 56 | Supplying and fixing 3 pin ceiling rose on the existing junction box/wooden block including connections etc. as required |
| 57 | Supplying and fixing of 2 way junction boxes |
| 58 | Supply , installation testing and commissioning ofof wall mounted fan of sweep 400 mm plastic body , 1300 rpm speed minimum air delivery 75 cmm acrodynamically designed PP blades , superior technology for enhanced air thrust unique pivot arrangement for tiltinh suitable for 230volt , 50 hz AC supply as per approved make |
| 59 | LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 60 | 18-22 watt |
| 61 | Supplying and fixing of following sizes ofmedium class pvc conduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recesssed conduit as required. |
| 62 | 25 mm |