| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 4 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 5 | G.S. Sheet |
| 6 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 7 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 8 | 12 mm cement plaster of mix : |
| 9 | 1:4 (1 cement : 4 River sand) |
| 10 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 11 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 12 | Ridges plain (500 - 600mm) |
| 13 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour |
| 14 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 15 | Finishing walls with water proofing cement paint of required shade : |
| 16 | New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 17 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 18 | One or more coats on old work |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 20 | One or more coats on old work |
| 21 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 22 | 1:4 (1 cement: 4 River sand) |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. |
| 24 | Size of Tile 600x600 mm |
| 25 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 26 | 6 mm thick Cement fiber board as per IS: 14862 |
| 27 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : |
| 28 | Superior hard wood Cat-II (B) |
| 29 | White washing with lime to give an even shade : |
| 30 | Old work (one or more coats) |
| 31 | ELECTRICAL WORKS |
| 32 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 33 | Group C |
| 34 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 35 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 36 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 37 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 38 | Supplying and fixingSuitable PVC boxon surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 39 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin5/6 & 15/16amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 40 | Supplying of prewired LED tube light T5 20W/22W (MAKE INTENSO LXS BATTEN 4 FEET 20 W) (Make Havells/Polycab/Crompton) or Equivalent to ISI Standarad. |
| 41 | Installation, testing and commissioning of pre-wired, LED FITINGof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 42 | Supplying of A.C. Ceiling fan(1200mm sweep 1 Star Ratting)USHA ENERGIA 50W suitable for operationon 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required.(Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard). |
| 43 | Supplying and fixing stepped type electronic fan regulator (Socket type)on the switch box including connectionsetc. as required. Make : anchor/polycab/havells etc or equvalent to ISI standard. |
| 44 | Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 45 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 46 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 47 | 4way, Double door |
| 48 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 49 | Single Pole MCB |
| 50 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 51 | 40 Amps, 2 Pole Isolator |
| 52 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 53 | Providing and laying earth connection from earth electrode with 6.00 sq. mm FR Flexible Wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 54 | Providing and fixing 4.00 mm FR Flexible Wire on surface or in recess for loop earthingas required. |
| 55 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 56 | Supplying and fixing of Wooden meter board of Size 400mm X 200 mmx20mm etc as required. |