| 1 | Supply , installation,testing and commissioning of Automatic micro Processor based 11 KV Tranformer energy monitoring system for 500 to 750 KVA Transformer via sat satellite Controlled data communication out put pot with following feature all enclosed in MS powder coated box of 1.5 sqmm of suitable size :-A)Automatic monitoring of electrical data parmameters of LT side of transformer load / Voltage of each phase communication pot.B) Sending Ringer tone based alert with voice calling with nature of fault to pre -defined 5 mobile numbers with area code with date and time with google location of transformer for high loading 12 nos parameters of transformer via Vsat satellite controlled data transmitter and non gprs , non gsm sim based data transmission as mentioned below:-i) High voltage R Phase LT Side ii)High voltage Y Phase LT Side iii) High voltage B Phase LT Side iv) High currentR Phase LT Side v)High current Y Phase LT Side |
| 2 | vi) High current B Phase LT Side vii) MCCB 1 TRip with areaviii) MCCB 2 TRip with areaix) MCCB 3 TRip with areax) MCCB 4 TRip with areaxi) Oil Level lowxii) Transformer Body Temperature HIghC) Satelllite Vast controlled out put data pot for transmit ion of Transformer energy data To controal room for record generation with Livegraphical trends for current peak load on each phase for load balancing /high voltage /high temperatureD) Live data monitoring at an interval of 60 seconds via satellite vsat controlled data transmitterE) inbuilt Data storage for at least Two yearF) With LCD Display G) monitoring of Energy Parameters such as frequency, 3 Phase urrent , power factor , frequency,KVA, KVAH,KW and KWH can be monitored the central control roomH) Automatic monitoring of electrical data parameters for upto 500 Kv Transformer I) All the electrical and alarm data can be printed in EXCEL Format for report generation with date and time for week /Monthly /Yearly) |
| 3 | Ditto- as per ser No-01 above but for 400 KV Transformer |
| 4 | Ditto- as per ser No-01 above but for 315 KV Transformer |
| 5 | Ditto- as per ser No-01 above but for 250 KV Transformer |
| 6 | Ditto- as per ser No-01 above but for 100 KV Transformer |
| 7 | Supply ,installation , testing & commissioning of CT 500/5 To 200/5 (set of Ct per Transformer) Make :- AE/UEE/DELTA |
| 8 | Supply ,installation , testing & commissioning of temperature sensor micro chip type RTD type MakeMake :- Unison /Crystal/Select |
| 9 | Supply ,installation , testing & commissioning of oil sensor ultra sonic type to monitor oil level of conservator from 0 % To 100 % Make :- Unison/Hamilton/micro devices |
| 10 | Supply ,installation ,testing and commissioning of V-sat Controlled transmitter PCB card with inbuilt micro chip antenna to be installed in Automatic micro Processor based 11 KVA transformer energy mointoring Panel Kv of 500 Kv to 200 Kv to transmit Energy monitoring data to control room via Vsat Satellite controlled High power transmitter and to transmit Transformer 12 alert Ringertone based alert with voice calling with nature of fault to 5 mobile nos and via Vsat Controlled Non sms based but Words-up based alpha numericbased alert with alert value of fault to pre -defined 5 mobile numbers with area code with date and time with goolge location of transformerMake:- Unison Egg Enterprises/Rockwell automation (Allen Bradely ) megha automation |
| 11 | Supply installation , commissioning and testing of VSAT satellite controlled data Master Receiver panel With Vsat micro chip antenna to receive 12 nos 11 Kv transformer energy real time data such as frequency ,3 PhaseVoltage , 3 phase current , Power factor, frequency , KVA,KVAH KW and KWA via 40\" LED screen with 500 gb data storage and with SCADA software and with inbuild UPS of 600 VA with USB & HDMI pot with SMPS power supply with bluetooth enabled device to operate mouse, keypad and WI-Fi controlled printer out -put data transmitter all enclosed in MS powder coated box of 1.5 sqmm of suitable size.Make:- Unison Egg Enterprises/Rockwell automation (Allen Bradely ) megha automation |
| 12 | Supply, installation, commissioning and testing of Vsat to wi-fi converter with Vsat micro chip Antenna of frequency range of 48 ghz and with high power transmitter with inbuilt SMPS power supply all enclosed in MS Powder coated box of 1.5 sqmm of suitable sizeMake:- Unison Egg Enterprises/Rockwell automation (Allen Bradely ) megha automation |
| 13 | Supply, Installation, commissioning and testing of 40\" LED screen with HDMI & VGA input pot and with SCADA SoftwareMake:- LG, Sony, Samsung, Google |
| 14 | Supply, Installation, commissioning and testing ofwi-fi controlled A4 Laser Printer B&W with Bluetooth mose and Bluetooth keypadMake:- HP, Canon, Brother |
| 15 | Supply & fixing on wall / Laying in ground 6x1.5 sqmm PVC insulated & PVC Copper armoured cable with heavy duty PVC saddles 60 cm apart complete all as specified and directed by Enge-in-charge |
| 16 | Supply & fixing on wall / Laying in ground 4x1.5 sqmm PVC insulated & PVC Copper armoured cable with heavy duty PVC saddles 60 cm apart complete all as specified and directed by Engr-in-charge |
| 17 | Supply & fixing on wall / Laying in ground 3x1.5 sqmm PVC insulated & PVC Copper armoured cable with heavy duty PVC saddles 60 cm apart complete all as specified and directed by Engr-in-charge |