Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on stone masonry/Brick Masonry incl racking out joints, hacking for key scrubbing down with water and direction by Engr- In Charge. |
| 2 | M&L for 10 mm rendering in CM 1:6 on fair face of brick workor on concrete surface finished even andsmooth without using extra cement complete all as specified and directed. |
| 3 | M&L for 05 mm rendering in CM 1:3 on fair face of ceiling or on concrete surfaces finished even andsmooth without using extra cement complete all as specified and directed. |
| 4 | M&L for 10 mm rendering in CM 1:4 on fair face of wall or on concrete surfaces finished even andfair with water profinfing compound (WPC)complete all as specified and directed.(WPC Measured seprately) |
| 5 | M &L for Preparation of newplasteredsurface of walland applying twocoat of oil emulsion distemper of approved tints over a coat of interior wall primer complete all as specified and directed by Engineer-in-Charge.. |
| 6 | M &L for Preparation of newplasteredsurface of Ceilingand applying twocoat of oil emulsion distemper of approved tints over a coat of interior wall primer complete all as specified and directed by Engineer-in-Charge.. |
| 7 | M&L for preparing new plastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint of required shade, on external walls/RCC surfaces/soffits of chajjas/roof projection/cantilivers/balcony etchaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, including necessary scaffolding arrangement as required at sitecomplete all as specified and-as-directed. |
| 8 | M&L for complete removal of existing treatment incl preparation of wall surfaces and fill the crack of wall with crack filler paste and applyingtwo coat of oil emulsion distemper of approved tints over one coat ofprimerto prepare the surface even and smooth, complete all as specified and directed by Engineer-in-Charge.. |
| 9 | M&L for complete removal of existing treatment incl preparation of ceiling surfaces and fill the crack of ceiling with crack filler pasteand applyingtwo coat of oil emulsion distemper of approved tints over one coat ofprimer complete all as specified and directed by Engineer-in-Charge.. |
| 10 | M&L for complete removal of existing treatment incl preparation of wall surfaces and fill the crack of wall with crack filler paste and applying Two or more coats of 100% Premium acrylic emulsion paint of required shade, , having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, including necessary scaffolding arrangement as required at sitecomplete all as specified and-as-directed. |
| 11 | M&L for preparation of old decorated steel surfaces of any description, not otherwise described over 10 Cm width & girth and applying one coat of synthetic enamel paint as camouflage / Ordinary pattern complete all as specified and directed by Engineer-in-Charge. |
| 12 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from sitecomplete all as specified and directed. |
| 13 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm eachandcomplete all as specified and directed. |
| 14 | Supply and fixing 35mm thick, IInd class hard wood plain, framed, panelled factory made shutters with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete incl S & F fwg items As approved by Accepting Officer.(a) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(b) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm-1 No per leaf(d) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 No per leaf |
| 15 | S & F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-I section 8 clause 8.20 (a) kiln seasoned and chemically pressure treated all as specifeid including stainless steel 304 grade wire cloth ( 0.36mm nominal dia of wire and average width of aperture 1.40 mm ) and incl supply and fixing following items:-(a) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(b) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 nos per leaf |
| 16 | S&F in repair 100mm size MS butt hinges and fixed to PVC frame /Wooden Frame and angle iron frame by necessary welding complete all as directed. |
| 17 | S & F in repairs 200mm long SS tower bolt (304 Grade) fixed with SS screw, complete all as specified and directed |
| 18 | S & F in repairsSS(304 Grade)bow handle,of 200 mm long fixed with SS Screw complete all as specified and as directed. |
| 19 | S & F in repairs SS (304 Grade) sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets , fixing bolts and sliding bolts of extruded section with SS Screw,complete all as specified and directed. |
| 20 | S&F in repairs 140 mmfloor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor complete all as specified and directed |
| 21 | M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise specified with two coats of synthetic enamel paint over one coat of pink primercomplete all as specified and as directed. |
| 22 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as specified and as per drawing. |
| 23 | S & FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification incl the fwg S & F As approved by Accepting Officer(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm -3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf |
| 24 | S&F powder coated aluminium, three track sliding window frame of section minimum size 92.00x 31.75x 0.92 mm comprising of one No of fly proof shutter and two nos of glazed shutter frames of section size 32x18x0.92 mm thick with necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading and connected locking arrangement all as specified and directed. (Notes. (i) Glass filling in panels of window and stainless steel wire mesh/wire cloth shall be demed to be included in the quoted rate for the item, ii) stainless steel wire cloth in panels of fly proof shutter shall be0.36mm nominal dia of wire and avg width of aperture 1.40mm, fixed with aluminium wire staples,. iii) Glass filling in panels of glazed shutter shall be 5mm thick tinted sheet glass of approved make and shade/tint and directed by Engineer Incharge. |
| 25 | M&L for powder coated aluminium frame and shutter for door, window, ventilators, partion and sliding shutters etc ( Minimum thickeness of powder coating 50 micron) with one or more rebates including jointing cleat, aluminium snap beading 20 x 15mm, rubber gasket, glazing clip for fixing etc .complete all as specified and directed by Engr in charge. |
| 26 | S&F 5mm thick figured / tinted sheet glass of approved make and shade/tint filling in aluminium panels door/window/partion with necessary joining cleats, beading all as specified and directed. |
| 27 | S&Faluminium grill made out of 7mm x 4.5mm w\"ide flat, square ractangular or similar section, fixed with channel of size 38mm x 12mm x 13mm incl taking down (section 8778 complete all as specified (make: DECO GRILL No. DG 102 with aperture- 80mm or equipment as approved by GE. |
| 28 | S&Fstainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples or with aluminium / wooden beads, stainless steel screws and nuts bolts etc for ventilator complete all as specified. |
| 29 | S&F in repair Stainlesssteel tubing of 20 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets & finials fency type, stops fixed with ss screws etc all as specified & directed.Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered as approved by accepting officer. |
| 30 | S&F in repair for 16mm bore of CPVC of food grade pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down or up existing GI tubing/CPVC pipes & connections all as specified and directed by Engr-in-charge. |
| 31 | Supply & Fixingin repair 20 mm bore tubes medium grade galvanized with all fitting such as Tee, elbows, sockets, unions, plugs, short lenghts etc and fixed complete to walls and ceilings or laid in floors of any length including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-charge. |
| 32 | Supply & Fixingin repair 25 mm bore tubes medium grade galvanized with all fitting such as Tee, elbows, sockets, unions, plugs, short lenghts etc and fixed complete to walls and ceilings or laid in floors of any length including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-charge. |
| 33 | Cutting chases, pinning in making good to facing on brick walls & pointing in CM 1:3 for concealed water tubing cutting n exc 10 cm girth all as specified and as directed. |
| 34 | S&F in repair 15 mm dia bib tap,fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed allasspecified anddirected. |
| 35 | S&F in repair 15mm bore CP fancy type stop valves/angle cock, cast copper alloy, screwed both ends for iron pipe orforunion complete all as specified and as directed. |
| 36 | S&F in repairs 15mm dia Bib tap (2 in 1 type)of brass, chromium plated fancy type glossy finish fixed in repairs completeall as specified and directed. |
| 37 | Supply & Fixingin repairCorner glass shelf size 200 mm radius with and including bracket and glass complete set etc. |
| 38 | S&f in repair 15mm bore pillar tap cast copper alloy fancy typeswan neck with 360 degree swivel spout, chromium plated screwed down high pressure, with or without letters Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipes and fixed all as specified and directed. |
| 39 | S&F in repairs chromium platedswivel shower roses with or without swivel joints,for fixing with 15mm pipe fixed all as specified |
| 40 | S&f in repair600X450 mm bevelled edge mirror, fancy type of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 41 | S&Fin repairs tubular towel rail, brass cromium plated, 20mm dia, D type, 60cm long between flanges completeall as specified and directed Engrs-In Charge. |
| 42 | S&Fin repair PVC connection 15mm bore length not less than 600mm long with both ends PTMT nuts complete all as specified. |
| 43 | S&F in repair vitreous china wash down water closet pan pedestal pattern white including connection in drain andin flushing pipe complete including \"P\" or \"S\" trap and including plastic water closet seat cover with flat bottom and cover with MS Chromium plated hinge divice ISI marked complete all as specified and directed . |
| 44 | S & F in repair Vitreous china premium/1st quality wash basin, white, size 550x400 mm including S&F all accessories as recommended by manufacturer complete fixed in position in all respect as per manufacturer\"s instructions and all as specified including all Waste fittings, brackets, brass,chromium plated for glazed ware sinks, basins, waster pipe etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, |
| 45 | S & F in repair Flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified. |
| 46 | S&F in repair 20/25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe |
| 47 | S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 48 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls or laid in floors incl fixing of bend etc complete all as specified and directed. |
| 49 | S&F in repairs 110 mm bore PVC [SWR] Junction single [single \"T\" or \"Y\"] equal or unequal, completeall as specified and as directed. |
| 50 | Demolition of stone/ boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unservicable materials, debris, rubbish to out side MD land complete all as specified and as directed. |
| 51 | M&L for precast-cement concrete block masonary with solid blocks type D-1 ,1:3:6 (20mm graded aggregates) exc 10 cm in width and setting in CM 1:4 ,complete all as specified and directed |
| 52 | Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to stores and removing debris outside the MD land. |
| 53 | S&F Non-Skid ceramic Coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 15mm thick screed bed in CM 1:4 complete all as specified. |
| 54 | S&F Vitrified ceramic tiles in light shade10mm thick (square/ractangular) polished,area of each tilesnot exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 15mm thick screed bed in CM 1:6, complete all as specified and directed |
| 55 | Ditto as item above but as in skirting over cement mortar backing plaster in CM1:4 15mm thick |
| 56 | M&L for Glazed ceramic glossy finish tiles coloured in vertical surface 450X300X7mmin any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 57 | M&L for 25mm thk PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in subbase of floors & finishing the surface even & smooth without using extra cement. |
| 58 | Dismantling of posts or struts (wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 59 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 60 | Supply only chain link MS galvanized fencingsize or type all as specified by Engr-in-charge. |
| 61 | Fixing only chain link fencing including line wires any mesh size and type of standard rails complete all as specified and as directed. |
| 62 | S&F Mild steel in flat, round or square bars, in available lengths, Fe 290 (Gde E-165) complete all as specified and as directed. |
| 63 | M&L mild steel screw bolts (machine Made) with hexagonal or square heads at one end and screwed the other to be fitted with washer and one hexagonal or square nut exc 15cm and n exc 22.5cm long, dia of neck 11-15 mm complete all as specified and as directed. |
| 64 | S & F mild steel work as in angle iron , Tee etc as in posts & strut in fencing including cutting tops to shape, drilling holes notching for wire etc flat iron fillets for securing wire mess etc including all necessary drilling, bolting or riveting etc and similar works conforming to Fe-410-0 or Fe-310-0 (Make Tara or equivilant) |
| 65 | Excavation in post holes in any type of soil, n exc 0.50 cum in each post, getting out returning, filling in and ramming earth or broken rubble mix with earth around in layers n exc 25 cm watering and removing surplus soil to a distance n exc 50 M and making good surface and all as specified. |
| 66 | Dismantling structural steel work including doors gates but excluding framed truss etccomplete all as specified and directed |
| 67 | S&F framed work as in gate etc of angle,tubularor other section with gusset plates, braces etc complete drilled for fixing of steel sheeting or other covering prepared for hanging or sliding with and including either hooks & hinges for steel hanging door fitings complete all as specified and as directed. |
| 68 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and as directed. |
| 69 | S&FPre- painted galvaiume aluminum zinc coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping crews as specified complete all as specified and directed |
| 70 | S&F for hollow,rolled sections, MS Pipe as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conf to Fe-410-w or E -250 quality A complete all as specified and directed. |
| 71 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces including prepration of new steel surfaces of any description over 10cm girth or width complete all as specified and as directed. |
| 72 | Demolition of concrete in ground floors and pavingnexc 15cm thickness (below or above ground level ) complete all as specified and directed |
| 73 | M&L for75mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement, including making jointsto the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed. |
| 74 | M&L 75mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed. |
| 75 | Demolition Stone slabs and tiles of any description or thickness in floors aprons etc laid dry or laid dry and pointed complete all as specified and directed |
| 76 | M & L for Granite of black / green / imperial red (colour as approved by Accepting Officer) of any type machine cut as in shelves/steps/counter tops, 20 mm thick, set and jointed in cement slurry over & including screedof 15 mm thick / rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing on unpolished kota stone slabs and including rubbing, cutting and mirror type polishing and bull nose on exposed sides complete all as specified .Note : Single piece should be used in steps/cills/jambs/shelvesor equivalentas approved by accepting officer. |
| 77 | M&L for 60mm thickness machine pressed / Rubber moulded precast interlocking paver block anyshape and size conforming to IS - 15658-2006 ofM-40 grade with grey cement and no pigment complete all as specified and directed |
| 78 | M&L for sand filling25mm thick under floors or in foundations inc. watering and consolidation |
| 79 | M&L for servicing of rolling shutter, making it operational including application of grease, cleaning of sliding channel, making good defective parts, icluding welding if required, making operational throughtout the period of contract any applying one coat of synthetic enamel paint complete all as specified and directed. |
| 80 | M&L for welding in repairs exc 2.5cm but n.exc 5 cm in length Thickness of metal to be welded N exc 6mm complete all as specified and as directed. |
| 81 | M&L for Charging of refrigerant (407) in the Scroll type chiller compressor of capacity 13 TRincluding topping of etc. complete as required and directed. |
| 82 | Supply and fix in repair of Micro processor controller based PCB card with display unit for 3x37.7 TR capacity AC plant complete all as directed. Make- Blue star.Model No-XWC3S-039AR2 |
| 83 | Supply and fix in replacement of Drier suitable forAC Plant of model XWC3S-039AR2 complete all as directed. Make: Danfoss / Indofoss |
| 84 | M&L for humidity control system for all 3 AHUs including control wiring including replacement of U/S0.5 HP pump complete all as directed. |
| 85 | M&L in replacement for 3 pole MCB TP C-40 Amps complete all as directed. Make- ABB / Legrand / L&T/HAGER/GE/SIEMENS. |
| 86 | S&F, installation and testing in replacement of cooling tower Water sprinkler system complete set ( comprising of cooling tower motorof capacity 3.7 KW/5HP ,930 RPM, Class F with long shaft, Fan blade, PVC Pipe)incl taking down existing onecomplete all as specified and directed Cooling tower make: OSWAL or other equivalent make Note:- motor to be submitted in MES Store yard |
| 87 | S & F in replacement ofPVC Fins suitable for cooling tower of 3X37.5 TR AC plant complete all as specified and directed. |
| 88 | M&L for repair of Control Wiring/Resetting of Chiller Plant by replacement of copper wire , fault finding , making serviceableas per existing size in each AC Plant unitall as specified and directed by Engr in-Charge. |
| 89 | S&F in replacement Pressure gauge with siphon & cock complete all as specified and directed. |
| 90 | S&F in replacement thermometer complete all as specified and directed. |
| 91 | S &F in replacement Expansion valve suitable for 37.7 TR AC Plant Model No XWC 3S-039AR2 TR AC plant complete all as specified and directed. Make - Danfoss or equivalent. |
| 92 | M & L for cleaning ofwater cool condenser coils/ chiller coils through Non corrosion chemical of scroll typecompressor of AC Plant of capacity 3x37.7 TRusing velin clean asdescaling compoundand removing all waste/foreignmaterial (One unit one job) complete etc all as specified and directed. |
| 93 | M&L for cleaning, servicing of cooling tower of Chiller Plant with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower etc. & make the necessary alignment complete all as specified and directed. |
| 94 | M & L for De-scaling of complete system of chilled water supply line and return line of one magz incl cleaning of strainers ,using velin clean asdescaling compoundand removing all waste/foreignmaterial complete all as specified and directed. |
| 95 | M&L for finding out the leakage and pressure test of the condenser and cooling coil of Chiller Plant compressor of 13 TR each capacity and repair the leakage point by brazing/soldering including taking down/re-fixing the unit and testing the unit complete all as directed. Note: The Gas required for testing and charging will be measured and paid separately in relevant item of Schedule-\"A\". |
| 96 | S&F in repair LP cut off control cut out 12 volt suitable for Scroll type AC Plant Compressor of capacity 13 TR etc all as specified and directed. Make: Danfoss /Indo Foss. |
| 97 | S&F in repair HP cut off control cut out 12 Volt suitable for Scroll type AC Plant Compressor of capacity 13 TR etc all as specified and directed. Make: Danfoss/Indo Foss. |
| 98 | S&F in repair Inlet Water Temperature sensor 12 volt suitable for Scroll type AC Plant of capacity 37.7 TR etc all as specified and directed. Make: Danfoss/Indo Foss. |
| 99 | S&F in repair Outlet Water Temperature Sensor 12 Volt suitable for Scroll type AC Plant of capacity 37.7 TR etc all as specified and directed. Make: Danfoss/Indo Foss. |
| 100 | S & F in replacement of unserviceable Control Card of AC Chiller plant 37.7 TR Unit Complete all as specified and directed. |
| 101 | Repair and servicing if required of AHU filter by Opening & Cleaning & Re-fixing of the same at existing place etc all as specified and directed. |
| 102 | S&F in replacement 3 Pole Relay contactor 32 to 63 Amp Three Phase voltage 415 V 50 Hz with NO-NC complete all as directed. |
| 103 | S&F in replacement copper 125 Amps connector strip complete all as specified and directed. |
| 104 | S&F in replacement Push Button for start & stop of ac plant unit complete all as specified and directed. |
| 105 | S&F in replacement NO + NC suitable for push button switch three phase 7.5HP Pump set all as directed. |
| 106 | S & F in replacement ofscroll type compressorcapacity 13 TR, Model No.-SZ 185 S4RC make Danfoss including flushing with N2 gas and charged with suitable gas, installation and testing incl taking down existing one complete all as specified and directed. |
| 107 | M & L in replacement of Chilled water MS ERW Class \"C\" pipe of size 100mm dia complete with all fittings including duly insulated with 25mm thick Nitrile insulation GC Sheet in two layers with closed cell elastomeric insulation 30 to 40 kg/cum density complete all as specified and directed. |
| 108 | M & L in replacement of Chilled water MS ERW Class \"C\" pipe of size 50mm dia complete with all fittings including duly insulated with 25mm thick Nitrile insulation GC Sheet in two layers with closed cell elastomeric insulation 30 to 40 kg/cum density complete all as specified and directed. |
| 109 | M&L for repair/servicing greasing etc of Condenser/Chiller induction Pump motor Of cap 7.5 HPand re-fixing the same at existing location with proper alignment after replacing accessories as under: -(a) Gland bush , studs, nuts & washers(b) Ball bearing of pump set(c)Remetaling grinding and polishing of pump shaft to required size or all as directed(d)Gland packing ,greasing in pump bearings and making its proper alignment etc |
| 110 | All as per above item 109 here-in-before but of capacity 10 HP Motor. |
| 111 | All as per above item 109 here-in-before but of capacity 12.5 HP Motor. |
| 112 | Dismantling the induction motor pump set of capacity 7.5 HP, removing the existing burnt out winding and rewindingwith copper winding wire of existing gauge and weight, heat varnishing including replacement of all insulation materials and terminal leads etc. for AC, 3 Phase, 415 volts grade incl any other petty/minor items/spares required for making the motor functional and shifting/transporting back to AC plant and installation, commissioning and testing on full load complete all as specified and as directed by the Engineer-in-Charge. |
| 113 | All as per above item 112 here-in-before but of capacity 10 HP Motor. |
| 114 | All as per above item 112 here-in-before but of capacity 12.5 HP Motor. |
| 115 | S&F in repair 15 mm dia Medium grade GI pipe with all running fittings such as bends, tees, unionss, elbows, connecting pieces etc for Water Supply pipe line to Humidifier Tank in AHU complete all as directed.Make: JINDAL/TATA/ITC. |
| 116 | S&F in repair 25 mm dia Medium grade GI pipe with all running fittings such as bends, tees, unionss, elbows, connecting pieces etc for Water Supply pipe line to Humidifier Tank in AHU complete all as directed.Make: JINDAL/TATA/ITC. |
| 117 | Supply, install, testing & commissioning of CI Non-Return (Reflux) Valve 80 mm bore, both end flanged, class PN 1.6, ISI marked conforming to IS 5312 (Part I & II) including making new flanged joints with rubber gasket, necessary bolts, nuts, washers etc of suitable size incl taking down old unsv one complete all as specified and to the entire satisfaction of the Eng-in-Charge. Note:- The rate quoted by contractor is deemed to be inclusive of Cutting and making new flanged in existing line at both end for installing NRV. |
| 118 | S&F in replacement Gun Metal Gate valve 25 mm size complete all as specified and directed. |
| 119 | Supply, install, testing & commissioning of CI Butter fly Valve 80 mm bore, both end flanged, ISI marked including making new flanged joints with rubber gasket, necessary bolts, nuts, washers etc of suitable size incl taking down old unsv one complete all as specified and to the entire satisfaction of the Eng-in-Charge. |
| 120 | Description all as per above item No. 39 but of 100 mm dia complete all as specified and directed. |
| 121 | S&F in replacement Single phase preventer complete all as specified and directed. |
| 122 | S & F in replacement AHU belt of suitable size as per Existing belt complete all as specified and directed. |
| 123 | S&F in replacementAHU Motor PulleyNo-115x27x28,SCH No-30,JC-10389 complete all as specified and directed. |
| 124 | S & F in replacementpre filter EV-4 model of AHU unit of capacity 8000 cfm complete all as specified and directed. |
| 125 | S & F in replacementPVC insulated PVC round shethed copper conductor cable(Flexible) 10 Sqmm 3core,1100 Volts gradecomplete with cable copper lugs with cconnection including testing complete fixing to main panel to PCB panel all as specified and directed. |
| 126 | Supply and fix in replacement safety valve of compressor line as per existing complete all as specified and directed. |
| 127 | Supplying, Fixing, testing & commissioning of voltage monitoring relay With DPDT Contacts to protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance, Suitable for 3 Phase 3 Wire system, Selectable Under Voltage / Over Voltage Trip level, Selectable Time Delay, for Selectable Phase Asymmetry, LED indications for power and fault conditions, Voltage sensing ,2 C/O configuration.complete all as pecified and directed by Engineer-in-Charge. Make: GIC/L&T/SEIMENS or equivalent. |
| 128 | S&F in replacement of Water Flow Switch including testing commissioning complete all as specified and directed. |
| 129 | S&F in replacement of Compressor Heater As per Existing one suitable for AC Plant Model No. XWC3S-039AR2 complete all as specified and directed. |
| 130 | S&F installation and testing in replacement of5HP/3.7KW, 3-phase 4 pole motor having 654RPM suitable for AHU unit model No. ZDS-80 having Air flow capacity of 8000 CFM complete all as specified and directed. |
| 131 | S&F in replacement Fan PulleyNo-250X2A of AHU unit Model No. ZDS-80 complete all as specified and directed. |
| 132 | Maintenance, servicing and testing of split type/window type AC, capacity 1.5 ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for summer to ensure cutting off of compressor in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge.Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor. |
| 133 | WINDOW/SPLITTYPE AIR CONDITIONERSupply & fixing in replacement, new compressor for inverter type splitAC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system(Compressor should be company sealed and brand new suitable as per existing one) complete all as specified and directed.Make: Haier / LLOYED / Voltas / Blue star /LGNote: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge. |
| 134 | All as per Srl Item No 133.00 here-in-before but 1.5 Ton capacity Non-inverter type split AC complete all as specified and directed. |
| 135 | All as per Srl Item No 133.00 here-in-before but 1.5 Ton capacity Window type AC complete all as specified and directed. |
| 136 | Material and labour for trickle charging of gas as required (ground requirement) in split/window type AC of capacity 1.5 ton, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all as specified and directed. |
| 137 | Supply & fixing nylon type filter pad20 micron for window type AC of capacity up to 1.5 ton including taking out unserviceable filter pad complete all as specified and directed. |
| 138 | Supply & fixing, in replacement, running capacitor 5-10 MFD 230 volts for blower motor complete all as specified and directed.Make : Keil / Asian /Tesla. |
| 139 | All as per Srl Item No 138.00 here-in-before but 36 - 40 MFD complete all as specified and directed. |
| 140 | All as per Srl Item No 138.00 here-in-before but 45 - 50 MFD complete all as specified and directed. |
| 141 | Supply & fixing, in replacement, starting capacitor 80-100 MFD 230 volts complete all as specified and directed.Make : Keil / Asian /Tesla. |
| 142 | Supply & fixing in replacement, single pole & Neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with MCB SPN 20 Amps, 240 Volts Complete all as specified and directed by Engr-in-Charge |
| 143 | Supply & fixing in repalcement Over load protection relay suitable for Split/window type AC of capacity 1.5 ton compete all as specified and directed. Make : Shriram /Renutrol. |
| 144 | Supply & fixing in replacement, thermostat switch of working temp 6 degree to 20 degree suitable for window type AC or split type of capacity up to 2 ton complete all as specified and directed.Make : Shriram/Renutrol. |
| 145 | Supply & fixing in replacement, blower motor 1/5 HP, double shaft, single phase suitable for window/split type 1.5 ton capacity inverter/Non-inveter type including testing complete all as specified and directed.Make:Blue-star/Haier/voltas/LG |
| 146 | Supply & fixing in replacement, fan blade for blower motor for window type/split AC 1.5 ton capacity inverter/Non-inveter type complete all as specified and directed.Make:Blue-star/Haier/voltas/LG |
| 147 | Supply & fixing in replacement, front grill for window type AC 1.5 ton capacity complete all as specified and directed. Make:Blue-star/Haier/voltas/LG |
| 148 | Supply & fixing in replacement single phase connector for split type AC upto 1.5 Ton capacity complete all as specified and directed. |
| 149 | Supply & fixing in replacement, fan blade for condensor motor for window type/split AC 1.5 ton capacity inverter/Non-inveter type complete all as specified and directed. Make:Blue-star/Haier/voltas/LG |
| 150 | Supply & fixing in replacement, Condensor fan motor 1/5 HP, singleshaft, single phase suitable for split/windowtype AC 1.5 ton capacity inverter/Non-inveter typeincluding testing complete all as specified and directed. Make: Blue-star/Haier/voltas/LG/Lloyed |
| 151 | Supply & fixing in replacement, front grill for split type AC 1.5 ton capacity complete all as specified and directed.Make: Blue-star/Haier/voltas/LG/Lloyed |
| 152 | Supply & fixing PVC copper conductor cable of size 2.5 Sqmm 3 core PVC insulated sheathled compete all as specified and directed. |
| 153 | Supply & fixing 4 way reverse valve of make: “RENCO” ISI marked in split/window type AC including replacement of cooling thermostat Make “PECIFIC” and two way heavy duty toggle switch make “GEC/SSK/KAY” with and including recharging the system withgas R22 or as required after fixing of four way reverse valve with remote control and sensor platefor cooling system and testing complete all as specified and directed by Engr-in-charge. |
| 154 | Supply & fixing in replacement, internal unit completefor inverter type splitAC 1.5 Ton capacity, comprising of blower motor, fan blade with rotor, evaporator with suitable filter, remote control system along with outer shell complete all as specified and directed.Make: Blue star/LG./Voltas/Haier/Lloyed |
| 155 | Supply & fixing in replacement, external unit complete for split type AC 1.5 Ton capacity, comprising of condenser coil, blower motor, blower fan, copper valve ½” & 5/8”,compressor,condenser motor complete all as specified and directed..Make: Blue star/LG./Voltas/Haier/Lloyed |
| 156 | Supply & fixing in replacement, suction and discharge pipe line of 1st quality copper, size ½” and 3/8” or 5/8” duly insulated along with 4 Sqmm 3 core flexible copper cable PVC sheathed complete all as specified and directed. |
| 157 | Supply & fixing in replacement, MS factory made stand powder coated (as per sample) including zebra bolts & washers complete all as specified and directed. |
| 158 | Supply & fixing in replacement, PCB kit for Non-inverter type split AC/window type AC including necessary connection and testing complete all as specified and directed by Engr-in-charge.Make : Make: Blue star/LG./Voltas/Haier |
| 159 | Supply & fixing in replacement, Outdoor unit PCB for inverter split type AC including necessary connection and testing complete all as specified and directed by Engr-in-charge.Make : Make: Blue star/Lloyed./Voltas/Haier |
| 160 | Supply & fixing in replacement, Indoor unit PCB for inverter split type AC including necessary connection and testing complete all as specified and directed by Engr-in-charge.Make : Make: Blue star/Lloyed./Voltas/Haier |
| 161 | Supply & fixing copper condensor coil suitable for window/split type AC of 1.5 ton capacity complete all as specified and directed. |
| 162 | Material and labour for taking out the split type AC 1.5 Ton capacity along with outdoor unit, shifting and installation to another location within same bldg or different bldg complete all as specified and directed by Engr-in-Charge.Note:- Removing & Refixing of AC and making hole in wall/other surface for croosing copper tube alongwith drain pipe andfastner nuts and bolts required for fixing are deemed to be included in quoted rate. |
| 163 | Supply & fixing in repair insulation cover of black colour for copper pipe of AC of any size complete all as specified and directed. |
| 164 | Supply & fixing in repair PVC flexible drain pipe for AC water outlet of size 20mm including all fittings complete all as specified and directed. |
| 165 | Supply & fixing in repair swing motor for split type AC of capacity 1.5 ton complete all as specified and directed. |
| 166 | Supply & fixing in repairs AC auto manual Voltage Stablizer of capacity 4 KVA with input Volt 125 - 280 Volts and output Volts 230-240 Volts, +2% variation, comprising of voltmeter, fuse unit socket, connected lead etc. with time delay system complete all as specified and directed Make : Venus/AE/Vintec (Volina)/Brentford/Whirlpool/V-Guard or as approved by GE. |
| 167 | Attending complaints and rectification of defects of any type AC, Refrigerator, Water Cooler, Deep Freezer,Voltage Stabilizer etc and testing after complete all as specified and directed.Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M and recorded in the register maintained for the purpose and contractor should attend and rectify the complained within 24 Hrs (ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc is deemed included in the unit rate quoted by the contractor. |
| 168 | DEEP FREEZER/REFREGIRATOR AND WATER COOLERSupply, fixing & testing in replacement new compressor for water cooler of capacity 40/80 Ltr or 60/120 ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed.Make: voltas/blue-star/Usha |
| 169 | S&F in replacementcondensor fanmotor HP- 1/32 ,RPM-1300 suitable forwater cooler havingcooling cap 40/60 Ltr/hror 60/120 ltr/hr with clips and motor fixing stand with fan blade complete all as specified and directed.Make: voltas/blue-star/Usha |
| 170 | S&F in replacement fan blade for condensing fan motor suitable for water cooler having cooling capacity 40/60 Ltr/Hr or 60/120 ltr/hr complete all as specified and directed. |
| 171 | Material and labour for trickle charging of gas R-134 (a) or as required in water cooler, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified. |
| 172 | Supply & fixing push type water tap, 15 mm dia, chromium plated suitable for water cooler incl taking down un serviceable one complete all as specified anddirected. |
| 173 | Supply & fixing water cooler trey siutable for 40/80 Ltr/Hror 60/120 ltr/Hr including waste water outlet pipe complete all as specified and directed. |
| 174 | Supply & fixing, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed. Make: SHRIRAM or RANUTROLL or INDOFOSS. |
| 175 | S&F in replacement of copper filter and capillary tube of water cooler of cooling capacity 40/60 Ltr/hr complete all as specified and directed. |
| 176 | S&F in replacement relay with over load protectors suitable for 40/60 Ltr/hr cooling capacitywater cooler complete all as specified and directed. |
| 177 | Supply & fixing in replacement PVC flexible drain pipe for water outlet of size 25mm including all fittings complete all as specified and directed. |
| 178 | S&F in replacement PVC connection pipe, 25 mm bore,70 cms in length with two Nos mild steel clamps and necessary brass screws etc. complete all as specified and directed. |
| 179 | S&F in replacementBall valve 15 mm bore with PVC float ball (I.S.I Marked) with check nut /socket/GI nipple complete all as specified and directed. |
| 180 | S&F in replacement condenser unit complete suitable for 40/80 Ltr/Hr capacity water cooler including gas charging,flushing out the system,brazing,welding and jointing the suction reed and discharge reed complete all as specified and directed. |
| 181 | Material and labour for preparation of old decorated steel surfaces of Water Coolers including scraping down smoke soot, moulds, moss, salts etc, removing oily & greasy material and applying two coats of synthetic enamel paint of first quality using ‘spray machine’ over one coat of primer including marking of SM/MES Srl No in block letters with black paint complete all as specified and directed. |
| 182 | Supply, fixing & testing new compressor for refrigerator/D-freedger of capacity 215 to 345 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed.Make:- Lloyed/whirlpool/Kelvinator/Godrej/Haier/voltas |
| 183 | Material and labour for trickle charging of gas of any type as required in refrigerator/D-freedger of capacity 215 to 345 Ltr, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified. |
| 184 | Supply & fixing in replacement freezerassembly comprising of DC Motor and fan blade,suitable for refrigerators of any make, 215 to 345 litres capacity including taking out unserviceable assembly complete all as specified and directed. |
| 185 | Supply & fixing in replacement door panel (AB plastic), procured from company,suitable for refrigerators of any make, 215 to 345 litrescapacity including taking outunserviceable door panel complete all as specified and directed. Make :Kelvinator / Zenith / Godrej / Whirlpool / Voltas/LLoyed/LG |
| 186 | Supply & fixing in replacement, PCB for inverter type Double door refigerator of capacity 310 to 345 ltr including necessary connection and testing complete all as specified and directed by Engr-in-charge.Make : Make :Kelvinator / Zenith / Godrej / Whirlpool / Voltas/LLoyed/LG |
| 187 | S&Fin replacement of condensor unit of refrigerator capacity 215 to 345 Ltrs includingjointing of tubes andtesting complete all as specified and directed.Note : Gas charging will be measured and paid for separately. |
| 188 | S&F in replacementcondensor fanmotor suitable for Refrigerator/D-Freedger having capacity 215 to 345 ltrwith clips and motor fixing stand with fan blade complete all as specified and directed. |
| 189 | Supply & fixing, in replacement starting relay ISI marked for refrigerator/D-freedger of different capacity/make including taking out unserviceable relay complete all as specified anddirected. |
| 190 | Supply & fixing, in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified anddirected. MAKE: SHRIRAM orRENUTROL or INDOFOSS. |
| 191 | Supply & fixing, in replacement capillary tube made of copper, any size suitable for Refrigerator/Water Cooler including taking out old unserviceable capillary tube complete all as specified anddirected. |
| 192 | Supply & fixing, in replacement capillary filter drier 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified anddirected. |
| 193 | Supply & fixing, in replacement capacitor for refrigerator of different capacity/make including taking out old unserviceable capacitor switch complete all as specified anddirected. |
| 194 | Supply & fixing in repair, door rubber gasket with magnetic strip for refrigrator/D-freezer of capacity upto 345 litres of any size make complete all as specified and directed by Engineer-in-Charge. |
| 195 | Supply & fixing in repairs, door lock with key for refrigrator of any make and capacity complete all as specified and directed by the Engineer-in-charge. |
| 196 | Supply & fixing in repairs, open type relay for refrigrator of any make of capacity upto 310 litres complete all as specified and directed by the Engr-in-charge. |
| 197 | Supply & fixing in repairs, PVC high density crisper (vegetable & fruit tray with crisper glass) suitable for any type refrigerator upto 310 litres complete all as specified and directed by Engr-in-charge. |
| 198 | Supply & fixing thermal overload protection relay of working capacity 90/230 Watt suitable for refrigerator/D-frredzer of 210-345 ltr complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail