| 1 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel striparmoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 120 sqmm complete all as specified and directed. |
| 2 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel striparmoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 70 sqmm complete all as specified and directed. |
| 3 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel striparmoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 25 sqmm complete all as specified and directed. |
| 4 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel striparmoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 16 sqmm complete all as specified and directed. |
| 5 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel striparmoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 10 sqmm complete all as specified and directed. |
| 6 | Supply, laying and testing aluminium HT cables, stranded compactedcircular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of pvc, galvanised steel flat strip armoured, & overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with upto date amendments, . laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc, 11 kV (E) grade, of size 3 core 95 sq mm complete all as specified and directed. |
| 7 | M&L cable jointing kit for 11 KV(Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size95sq mm complete all as specified and as directed. |
| 8 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 9 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and directed. |
| 10 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 11 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 12 | Supply and laying well burnt Bricks , locally available best quality (sub class \"B\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 13 | Supplying and laying un-reinforced precast concrete cable cover,Class HV, Type I, flat, size 300 mm x 180mm x40mm ,complete all as specified and as directed. |
| 14 | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore round insulated copper conductor and sheathed flexible cable,multistranded, three coreofnominal cross sectonal area1.5 Sq mm complete all as specified and as directed. |
| 15 | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31 9.0 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with blacksyenthic paint/ Stricker, includingpainting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthaticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole), including and all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed. Note:- Earth work, PCC work, shall be measured and paid separately.(ii) Execution of swaged pole will be allowed only after submission of Purchase Voucher and Manufacturing Test Certificate, to the Engineer-in-Carge |
| 16 | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-55, 11.0 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with blacksyenthic paint/ Stricker, includingpainting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthaticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole), including and all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed Note:- Earth work, PCC work, shall be measured and paid separately.(ii) Execution of swaged pole will be allowed only after submission of Purchase Voucher and Manufacturing Test Certificate, to the Engineer-in-Carge |
| 17 | M & L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 18 | M&L for PCC 1:3:6 type C2 (using 40 mm gradedaggregate) as in foundation for pole etc complete all as specified and as directed. |
| 19 | M&L for PCC 1:2:4type B1 (using 20 mm gradedaggregate) as in coping for pole including form work and finishing the surfaces even and smooth etc complete all as specified and as directed. |
| 20 | M&L Street Light Fittings Bracket, fabricated from GI Pipe 40mm Bore (dia), Light Grade, 1.00 METRE long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed. |
| 21 | S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make : Cat No. K-8250 of HENSEL or equivalent model in SPELSBERG/Sintex. |
| 22 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,efficacy 110/120 LPW, complete with IP 65/66 protection complete all as specified and directed. |
| 23 | Supply and fixing decorative post top for indirect light with IP 65 protection.Resistant to impact and corrosion.Glare-free and better uniformity complete all as specified and directed. |
| 24 | Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built,lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.(Excavation & earth work shall be measured separately) |
| 25 | Supply and fixing garden light 10W,LED ,IP65 rated inverted pyramid tripod type LED bolland with soft 360 degree light distribution complete all as specified anddirected. |
| 26 | S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 27 | S & F 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 28 | S&F Galvanised Iron Pipe 100mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 29 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 30 | Labour only for Horizontal Boring for PassingProtection Pipe up to 100mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note : Pipe to be measured separately. |
| 31 | Supply and install HT 11 KV out door type gang operated air- break switch suitable for horizontal or verticaltriple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 Amps complete all as specified and as directed. |
| 32 | M & L lightning arresters expulsion type Complete with all fittings, transmission class,suitable for 11KV, discharge capacity 65 kilo amp, complete all as specified and as directed. |
| 33 | Supply and fix Pin insulator porcelain vitreous 11000V grade, 150mm high, 150mm dia, nuts, bolts and washers etc, galvanised MS spindle , washers fixed on channels or directly on poles all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply and fix Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Two-in-series\" assembly for tension with tension clamps for conductors, working pressure 11000 volts all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc. complete all as specified and as directed. |
| 36 | M&L for 32x6mm galvanised iron strip including connection from earthing in continuation to end point,complete all as specified and as directedby Engrs-in-Charge. |
| 37 | Material and Labour RCC cable route indicator ofsize 1300x300x100 mm duly written \"HT CABLE\" in block letter, duly engrave as MES and painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:3:6) C2 using 40 mm graded stone in 600x450x300 mm for fixing route indicator complete all as specified and directed. Note :- (i)Unit rate of item includes excavation, PCC foundation for erection of route indicator.(ii) Slab of route indicator to be provided with proper TMT bars in reinforcement .(iii) Route indicator RCC slab to paintingwith two coat ofred/blue colour synthetic enamel paint over on one coatof white primer base all as specified and directed by Engr - in - Charge. |
| 38 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI strip 32 x 6 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 40 mm diaGI pipe (md grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wireincluding protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |
| 39 | Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.20m x 0.45m x 1.20m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus barmade ofaluminium, 400 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade.The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB\"s, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parametersPCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one : |
| 40 | (A) IncomingMCCB200 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 36 KA --- 01 Nos. (B) Outgoing(b) MCCB160 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 02 Nos.(c) MCCB16 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 03 Nos(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 41 | All as per BOQ Item No 39.00here-in-before butwith the following incoming and outgoing accessories :-BUS BAR4 Nos of bus barmade ofaluminium, 300 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade(A) IncomingMCCB160 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 36 KA --- 01 Nos. (B) Outgoing(b) MCCB25 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 36 KA --- 05 Nos.(c) MCCB16 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 02 Nos(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 42 | Supply,Installation , testing and commissioning of 11/0.433 KV Distribution station transformer of capacity100 KVA , 3 Phase, 50 Hz,Conf to IS 1180:2014, Level- 3 ,outdoor type,plinth mounted, step down transformer,Onan cooled,oil immersed,copper wound,with vector group DYN 11 ,complete with first filling ofIS 335 , ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories / mountings conforming to relevant IS and 7 position tap changer (Tapping range +5% to -10% in step of 2.5% each completeall as directed .Note for Transformer (i)Transformerto be placed on PCC plateform and its Bi directional roller to be locked properly(ii) The contractor shall furnish original bill certificate (purchase voucher) test certificate, and warranty certificate of thetransformer from manufacturer.(iii) The contractor shall submit the general arrangement darwing of transformers andget the approval of GE forMake and darwing of transformers before placing the order.(ivi) Prior to manufacturing the general arrangement drawing, design anddetails of transformer shall submitted to GE for approval. (v)Transformers shall be dispatched only after inspection at manufacture premises to be done by OEM Auth & MES Auth at manufacture premisesRoutinetestas per ISrelevant IS to be carried out at Factory in presence of MES rep. (vi) Connection of Transformer WTIto VCB through multi core copper conductor control cable of suitable size (irrespective of length) is deemed to be included in the item.(viii) Contactor shall submit the operating manual and maintenance scheduleoftransformersfrom OEM in two sets. |