Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-01-2026 | AMENDMENT TO BOQ | BOQ | 23-01-2026 |
| Sl. No. | Item Description |
| 1 | Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by Engineer In Charge. |
| 2 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and as directed by Engineer In Charge. |
| 3 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with allfittings, accessories,PVC junction boxes etcfixed to walls/ceilingswith and including concealed GI metal boxes 1.2 mm thick,(18 Guage)50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting modular switches, sockets, regulators etcand also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. for the following |
| 4 | (a) One light point/ exhaust fan pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 5 | (b) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same board complete all as specified and as directed by Engineer In Charge. |
| 6 | (c) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independentboardcomplete all as specified and as directed by Engineer In Charge. |
| 7 | (d) Onebell pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 8 | (e) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 9 | Description all as per Item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade, for one 6 pin socket outlet plug point, 6 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. |
| 10 | Description all as perItem No 3 here-in before but using 4.0 Sqmm singlecore copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. |
| 11 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through existing PVC/ Steel concealed conduitwith and includingconcealed GI metal boxes 1.2 mm thick,(18 Guage)50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting modular switches, sockets, regulators etcand also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following:- |
| 12 | (a) One light point/ exhaust fan pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 13 | (b) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same boardcomplete all as specified and as directed by Engineer In Charge. |
| 14 | (c) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independentboardcomplete all as specified and as directed by Engineer In Charge. |
| 15 | (d) Onebell pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 16 | (e) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge. |
| 17 | Description all as per Item No- 6 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. |
| 18 | Description all as per Item No-6 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. |
| 19 | Note for Item Ser No 3 to 8: (i) Cutting chases for conduits and sinking\"s for GI metalswitch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.(ii) Partially partlywiring in casing capingwith allfittings accessories PVC junction boxeswhereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoated against item. |
| 20 | Supply and fixingModular switch, one way6 A, one module, 230 Voltscomplete all as specified and as directed by Engineer In Charge. |
| 21 | Supply and fixingModular switch, Two way 6 A, onemodule,230 Voltscomplete all as specified and as directed by Engineer In Charge. |
| 22 | Supply and fixing Modular Bell push 6A ,one module 230 Voltscomplete all as specified and as directed by Engineer In Charge. |
| 23 | Supply and fixingModular switch, one way 16 A, onemodule, 230 Volts complete all as specified and as directed by Engineer In Charge. |
| 24 | Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Voltscomplete all as specified and as directed by Engineer In Charge. |
| 25 | Supply and fixing Modular socket outlet multipurpose,6A/16A - 2/3 pin combined 2 module, 230 Voltscomplete all as specified and as directed by Engineer In Charge. |
| 26 | Supply and fixing Modular socket outlet multipurpose,6A/16A - 2/3 pin combined with 16 Amps MCB 4 module, 230 Voltscomplete all as specified andas directed. |
| 27 | Supply and fixingSwitch piano, flush type,polycarbonate, single pole, one way 6Amp complete all as specified and as directed. |
| 28 | Supply and fixing Bell push, flush type, polycarbonate, 6 amp complete all as specified andas directed. |
| 29 | Supply and fixingSwitch piano, polycarbonate, flush type single pole, one way 16Amp complete all as specified and as directed. |
| 30 | Supply and fixingSocket outletswitch socket outlet, 2-in-1, 6 pin, 6 and 16 Amps, flush type completeall as specified andas directed. |
| 31 | Supply and fixing Socket outlet 2 in 1, 5 pin, 6A complete all as specified andas directed. |
| 32 | M & L Switch socket combination 2 in 1, 6 pin, 6 A flush type complete allas specified andas directed. |
| 33 | M & L Switch socket combination 6A/16A, 6 in 1 flush typecomplete all as specified andas directed. |
| 34 | Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified andas directed. |
| 35 | Supply and fixing electric Buzzer, Ding Dongbell suitable for operation on AC. 230 volts, single pole complete all as specified andas directed. |
| 36 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with allfittings, accessories, PVC junction boxes etc.with and includingconcealed PVC switch, socket, regulator mounting, SAC-WHT-JBX1, 86 Size,( HSN 85365020)junction box Make Jaquar or equivalent and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following |
| 37 | (a) One light point/ exhaust fan pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed |
| 38 | (b) Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed |
| 39 | (c) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same boardcomplete all as specified and as directed |
| 40 | (d) One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independentboardcomplete all as specified and as directed |
| 41 | (e) One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed |
| 42 | (f) Onebell pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed |
| 43 | (g)One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 44 | Description all as per Item No 24 here-in before but using 2.5 Sqmm singlecore copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed |
| 45 | Description all as per Item No 24 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed |
| 46 | Note for Item 25 to 27 : (i) Cutting chases for conduits and sinking\"s for PVC switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.(ii) Partially partlywiring in casing capingwith allfittings accessories PVC junction boxeswhereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoated against item. |
| 47 | M & L Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body complete all as specified andas directed. |
| 48 | M & L Lamp holder, PVC/ Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified andas directed. |
| 49 | M & L Fancy Lamp holder, PVC/ Polycarbonate type with back plate of brass terminal suitable for batten fittings complete all as specified andas directed. |
| 50 | Supply and fixing 6 Amps Top Plug with Indicator complete all as specified andas directed. |
| 51 | Supply and fixing 16 Amps Top Plug with Indicator complete all as specified andas directed. |
| 52 | Supply and fixing 16A - Motor Starter - 2 Modulecomplete all as specified and as directed by Engineer In Charge.Make- Legrand Cat No- 6794 71 or Equivalent in Havells cat No- AHRSMXW201 |
| 53 | Supply and fixing 25 A - Motor Starter - 2 Modulecomplete all as specified and as directed by Engineer In Charge.Make- Legrand Cat No- 6794 71 or Equivalent in Havells Cat No- AHRSMXW251 |
| 54 | Supply and fixing 32 A - Motor Starter - 2 Modulecomplete all as specified and as directed by Engineer In Charge.Make- Legrand Cat No- 6794 71 or Equivalent in HavellsCat No- AHRSMXW321 |
| 55 | Supply and fixing in repairs Modular white cover plate with frame, to true size ofthe existing concealed metal box & make as per site requirement of |
| 56 | (a) 3 Module |
| 57 | (b) 4 Module |
| 58 | (c) 6 Module |
| 59 | (d) 8 Module |
| 60 | (e) 12/16Module |
| 61 | (f) 18 Module |
| 62 | Supply and fixing in repairs GI metal flush boxes 1.2 mm thick,(18 Guage)50mm deep, with earth dolly, suitable for mounting modular white cover plate of size |
| 63 | (a) 3 Module ( Make- Legrand or equivalent Cat No - 6890 08 ) |
| 64 | (b) 4 Module ( Make- Legrand or equivalent Cat No - 6890 09 ) |
| 65 | (c) 6 Module( Make- Legrand or equivalent Cat No - 6890 10) |
| 66 | (d) 8 Module( Make- Legrand or equivalent Cat No - 6890 42) |
| 67 | (e) 12/16Module ( Make- Legrand or equivalent Cat No - 6890 11) |
| 68 | (f) 18 Module( Make- Legrand or equivalent Cat No - 6890 12) |
| 69 | Supply and fixing in repairs Plastic Surface Box -, with earth dolly, suitable for mounting modular white cover plate of size |
| 70 | (a) 3 Module ( Make- Legrand or equivalent Cat No - 6733 03) |
| 71 | (b) 4 Module ( Make- Legrand or equivalent Cat No -6733 04) |
| 72 | (c) 6 Module( Make- Legrand or equivalent Cat No - 6733 06) |
| 73 | (d) 8 Module( Make- Legrand or equivalent Cat No -6733 08) |
| 74 | Supply and fixing 3mm thickwhite (Hylam)sheet for electrical application to incorporate switches, sockets etc including Cutting, drilling, shaping of material to site requirement and fixing with brass cadmium screws of adequate size and length complete all as specified and as directed. |
| 75 | Note for Item Ser No 36 & 39 : (i)Item will also be exercised in repairs means Labour component involvedin taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated.(ii) Making good disturbed wall in cement mortar 1:3 , & with wall putifor concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department |
| 76 | Supply and fixing Smart Glowintelligent office lighting recessed luminaire size 600mm x 600mm,36 Watt,220 V AC,with built in PIR occupancy sensor offering flexibility of auto switching off when the space is not occupied complete with standard warranty of manufacturer from date of purchase/ installationcomplete all as specified and as directed by Engineer In Charge.Make Philips ( Type-RC383B P LED 36S-6500 G6 PSU OD WH PIR P) or equivalent in Jaquar |
| 77 | Supply and fixing amp rating 240V, 10KA \"C\" curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 78 | (a) SP 5 To 32 AMP |
| 79 | (b) SPN 32 AMP |
| 80 | (c) SPN 40 to 63 AMP |
| 81 | Supply and fixing 415V 10KA \"C\" curve, IP 20 protected terminals,miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 82 | (a) TP 25 To 63 AMP |
| 83 | (b) TPN 16 To 32 AMP |
| 84 | (c) TPN 40 To 100 AMP |
| 85 | S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar, Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system includinginserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed. |
| 86 | (a) SPN 4 Way. (Make Legrand Cat No - 5076 10orequivalent.) |
| 87 | (b) SPN 8 Way. (Make Legrand Cat No - 5076 11 or equivalent). |
| 88 | (c) SPN 12 Way. (Make Legrand Cat No - 5076 12 or equivalent). |
| 89 | S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar for each phase, Fully insulated & shrouded Neutral bars, Earthbar and Cable ties for Cable management, &provision for FP MCB / Isolator / RCCB / RCBO as incomer and SP MCB\"s as outgoing ,415Volts, IP 43 - #IK 09 with metal double door & magnetic locking system includinginserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface &colour to wall complete all as specified and as directed. |
| 90 | (a) TPN 4 Way. (Make Legrand Cat No -5076 80 orequivalent.) |
| 91 | (b) TPN 6 Way. (Make Legrand Cat No -5076 81 orequivalent). |
| 92 | Supplied and fixed Flush Mounting and Surface Mounting single pole and neutral sheet metal enclosure suitable for 240 V with neutral link, two pin, earth plug and socket plug topcomplete all as specified and as directed with |
| 93 | (a) One Single pole MCB upto 20 Amps |
| 94 | S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCCB DB with 250 Amps rated bus bar for each phase, Fully insulated & shrouded 2 Neutral bars, 2Earthbar and Cable ties for Cable management, &With provision for DPX³ 250 MCCB as incomer and SP/TP MCB\"s as outgoing, 415Volts, IP 43 - #IK 09 with metal double door & magnetic locking system includinginserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface &colour to wall complete all as specified and as directed. |
| 95 | (a) VTPN 4 Way. (Make Legrand Cat No - 5077 58 orequivalent.) |
| 96 | (b) VTPN 8 Way. (Make Legrand Cat No - 5077 59 orequivalent). |
| 97 | (c) VTPN 12 Way. (Make Legrand Cat No - 5077 60 orequivalent). |
| 98 | Note for Item Ser No 41 & 46 : (i)Item will also be exercised in repairs means Labour component involvedin taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated.(ii) Making good disturbed wall in cement mortar 1:3 , & with wall putifor concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department |
| 99 | Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed. |
| 100 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 100 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T |
| 101 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 125 Amps, of Make Legrand Cat No 4200 56 or Equivalent in L&T |
| 102 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 160 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T |
| 103 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 104 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 105 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 106 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC casing caping with allfittings,PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 107 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC casing caping with allfittings,PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 108 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into PVC casing caping with allfittings,PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 109 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 110 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 111 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 112 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 113 | S & F Digital timer switch 220/230 V, 50 Hz, 30 A for electrical On OFF ,items ceiling fan/ exhast fan/ lighting, 16 on off programme per day, manual start ON-OFF delay & cyclic timer switch with all connectingwiring and connecting to earth dolly complete all as specified and as directed.Make - Leyden cat part no KG316TJ or equivalent. |
| 114 | S & F auxillary contractor as per site requirementsuiatable for use a circuit capable of deliverig not more than 5000 RMS symmtrical amperes, 600 volts maximum , fuse : 80 RKS time delay , general use : 10 A, 415 V. with all connectingwiring and connecting to earth dolly complete all as specified and as directed.Make - L & T MNX 70 or equivalent . |
| 115 | Supply, installation, testing and commissioning of intelligent street light control Alpharex3 digital time switches - Astro suitable for 5 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, with combination function for creating switching programs in which the devices are switched according to astronomical time and/or fixed preset times, Daily astronomical calculation of the sunrise/sunset times based on the entered location with suitable contactor of 63A rating, 63A TPN MCB all complete as specified and directed. make- havells/L & T or equivalent |
| 116 | S & F PVC rigid non-metallic conduit of dia 20 mm diainclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge |
| 117 | S & F PVC rigid non-metallic conduit of dia 25 mm diainclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge |
| 118 | Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof,in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, andsupporting accessories of GI (Galvanized Iron) Threaded Rods, Fasteners, withnuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of |
| 119 | (a) Cable Tray 150mm |
| 120 | (b) Cable Tray200mm |
| 121 | (c) Cable Tray250 mm |
| 122 | (d) Cable Tray300mm |
| 123 | Note :- Supporting hanging/ wall fixing accesssories,shall be fixed atminimum length01 Mtr spanand will be measured as one length along with cable tray. Rate quoated shall deemed to be included in the unit rate quoated |
| 124 | Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth runningcomplete all as specified and as directed. |
| 125 | Note : Transportation to & fro involved of unserviceable ceiling fan to deposit inEM Store yard Ghatkopar and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate. |
| 126 | Servicing / over hauling of ceiling fan 230 Volts of any make and sweep, along with following others repairs.a). Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts. |
| 127 | b)Heating & varnishingto stator coils with super quality varnish and dried out properely with external heat as ordered & directed.c) Reassembeling of ceiling fan complete with all existingserviceable parts obtained against Item 1 (a),andnew parts as required / ordered by Engineer in Charge. |
| 128 | Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoated against this Item.(ii).Any unforeseen minor repair and minor parts that are not covered under Item No-86 , (a) to (c) ( Total cost less than Rs 100 ) but required to complete the repair work / smooth functioning of fanshallbe deemed to be included with the unit rate. (iii) Transportation of fan to workshop for repair and back to site in EM store yard at Ghatkopar is deemed to be included with unit rate.(iii). Rewinding of stator coils of ceiling fan , where involved shall be measured and paid separetely against relevant item of this schedule. (iv) 3 core PVC insulated and sheathed 0.75 Sqmm cable from ceiling rose tofan connector of adequate length (maximum upto 1 Mtr) and (greasing the bearing with ball bearing grease where involved)shall deemed to be included in the unit rate. |
| 129 | M & L for taking out old paint of ceiling fan (any size) with paint remover liquid , Preparing smooth surfaces for painting, cleaning all dust etc,filling cavities with filler, and Painting of complete ceiling/exhast fans including blades with synthetic enamel whiterust proof paint by spraying complete all as specified and as directed. |
| 130 | S & F Ceiling fan down rods cut to required length as per site requirement of 15 mm dia GI pipe (medium grade)to the existing trusses of any height including necessary welding, drilling holescomplete all as specified and as directed. |
| 131 | Material and Labourfor Radium Retro Reflective Vinyl Sticker, (Thickness 0.4mm,)water proof, wear resistant back with sticker, Resistant to fading, cracking, and peeling, colour as directed by Engnr-in- Charge, (for MES Property Inenfification)Numbering Fan any type, cut tocustomizable size font -Height not less than 20 mm and width not less than 15 mm with letters as-GE(NW) / E&M /CF / 001 / MES- Ghatkoparcomplete all as specified and as directed. Note- SerNo i.e 001 will change on each ceiling fan as directed by Engnr-in- Charge. |
| 132 | Supply and fixing,fresh air (exhaust) fan plastic body of250mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , withlouvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/Mstore yard Ghatkopar complete all as specified and as directed by Engineer In Charge. |
| 133 | Supply and fixing,fresh air (exhaust) fan plastic body of200mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , withlouvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/Mstore yard Ghatkopar complete all as specified and as directed by Engineer In Charge. |
| 134 | Supply and fixing,fresh air (exhaust) fan plastic body of150mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , withlouvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/Mstore yard Ghatkopar complete all as specified and as directed by Engineer In Charge. |
| 135 | Taking down chowkat or frame ( Wooden) / Steel not exc. 1.5 sq. mand removing to store complete all as specified and as directed |
| 136 | Supply and fixextruded Powder coatedAnodised aluminium section as in window, door, and ventilator shutters, fixed type without sash bar, (powder coating of any colour (Thickness or powder coating not less than 50 micron). with movable, openable or fixed type shutter or any pattern as directed, provision forexhaust fan opening & adjustable louvers,aluminium section weighing 0.55 kg/m including necessary glass 3mm thick ordinary quality, frostedjoining cleats, glazing clips, rubber packing, anodisedaluminium snap beading, screws, roller, handle, locks etcetc. complete all as specified |
| 137 | Supply and fixing LED light fitting 2 x 20 watt Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitablesize complete all as specified andas directed |
| 138 | Supply and Fixing LED Tube Light 20 Watt -4\"suitable forflame proof Tube light fitting as in replacement with side holders complete all as specified and as directed |
| 139 | M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick,buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level),connected to and including GI strip 25×4 mm as earthing lead by means of bolts, nuts, checknuts and washers of galvanized iron or steeldrawn throughGI pipe40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit withprecast RCC cover in CC 1:2:4 type B1with handle , with G.I 20 mm dia medium grade pipefor watering and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed. |
| 140 | M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick,buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level),connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts, check nuts and washers etc;GI pipe15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed. |
| 141 | Note for Item No 117 to 118. Item cost includes cost of dismantling unserviceable earthing pit above ground level with earthing electrode and making good as per existing ground. |
| 142 | S&F LED indoor decorative aluminum housing LED batten integrated type tube light fitting, suitable and includingwattage 20W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed by Engineer In Charge. |
| 143 | S&F LED indoor decorative polycarbonate housing LED batten integrated type tube light fitting, suitable and includingwattage 10W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed by Engineer In Charge. |
| 144 | Supply and fixing in repair 2 x 2 ftLED ultra modern slimluminaire suitable for armstrong /grid ceiling, recess mounting luminaire completeultra brite LED with very high efficacy of cap 36 W, 230V,complete all as specified and as directed by Engineer In Charge. |
| 145 | S & F in repairs heating element of 1.5 kw / 2.0 kw including rubber washer ISI marked any type complete all as specified and as directed by Engineer In Charge. |
| 146 | Taking downof water storage Gyser and refixing after repair at its own position or other location including new hlodfastnercomplete all as specified anddirected. |
| 147 | S&F in repairs thermostat for water storage heater SP 230V complete all as specified & directed |
| 148 | S&F in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed |
| 149 | S&F in repairs indicator neon lamp 230 volts SP square or round complete all as specified and as directed by Engineer In Charge. |
| 150 | S&F in repairs connection pipe of 45 cm long stainless steel anti slip technology,anti explosion design complete all as specified & directed |
| 151 | M & L for repair any type of defective electronic single Phase meter including any kind and type material and testing requiredcomplete all as specified and as directed by Engineer In Charge. |
| 152 | M & L for repair any type of defective electronic Three Phase meter including any kind and type material and testing required complete all as specified and as directed by Engineer In Charge. |
| 153 | Supply and fixingin repairs highly efficient high power multi LED flood fitting 150 watts with pressure die castaluminium housing reflector and enclosed with toughened glass IP66 protection, PF>0.95, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking complete prewired and connecting with 0.5 sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Surya/Philips/Luckar/CG Note ;- To be fixed at min height of 12 m building / store house |
| 154 | Supply and fixin repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glassIP656,LEDs 100 wattspower factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting,including aluminium die cast housing and aluminium heat sink on back side of fitting complete all as specified and as directed by Engineer In Charge.Note ;- To be fixed at min height of 12 m building / store house |
| 155 | Taking down and opening / dismantling of exhaust/ ventilation fan, 200/250/300 mm sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and re-fixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year. Note ;- To be fixed at min height of 12 m building / store house |
| 156 | All as per aboveitem no.47 but size for 450 mm sweep Exhaust fan complete all as specified and as directed by Engineer In Charge. |
| 157 | Supply and fixbearing Suitablefor existing ceiling fan of 1200/1400mm sweepcomplete all as specified and as directed by Engineer In Charge. |
| 158 | Supply and fixbush Suitablefor existing exhaust fan of 200/250/300 mm sweepcomplete all as specified and as directed by Engineer In Charge. |
| 159 | Supply and fix bush Suitablefor existing ceiling fan 1200/1400mm sweep complete all as specified and as directed by Engineer In Charge. |
| 160 | Supply and fixshaft Suitablefor existing ceiling fan of 1200/1400mm sweepcomplete all as specified and as directed by Engineer In Charge. |
| 161 | Supply and fixbearing Suitablefor existing exhaust fan of 400 mmsweepcomplete all as specified and as directed by Engineer In Charge. |
| 162 | Supply and fixbush Suitablefor existing exhaust fan of 400 mm sweepcomplete all as specified and as directed by Engineer In Charge. |
| 163 | Supply and fix bearing Suitablefor existing exhaust fan 200/250/300 mm sweep complete all as specified and as directed by Engineer In Charge. |
| 164 | Supply and fixshaft Suitablefor existing exhaust fan 200/250/300/400 mm sweepcomplete all as specified and as directed by Engineer In Charge. |
| 165 | Supply and fix capacitor 2.5/4 mfd capacity230 volts complete all as specified and as directed by Engineer In Charge. |
| 166 | Supply and fixing in repair 250/300 mm sweep PVC exhaust fan blade complete all as specified and as directed by Engineer In Charge. |
| 167 | Supply and fixing in repair exhaust fan motor 170 to 250V, 50 Hz (200 mm Sweep to 300 mm Sweep) suitable capacity and size complete all as specified and as directed by Engineer In Charge. |
| 168 | Supply and fixing in repair 250/300 mm sweep PVC exhaust lovers suitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 169 | Supply and fix capacitor 1.5 mfd capacity230 volts complete all as specified and as directed by Engineer In Charge. |
| 170 | Supply and fixing in repair 250/300 mm sweep 3 or 4 blade metal body fan blade suitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 171 | Supply and fixing in repair 250/300 mm sweep GI sheet exhaust lovers suitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 172 | Supply and fixing in repair 400mm sweep GI sheet exhaust lovers suitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 173 | Supply and fixing in repair 400 mm sweep 4 blade metal body fan blade suitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 174 | Taking down and opening / dismantling ofceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and as directed by Engineer In Charge. by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year. |
| 175 | Taking down and opening / dismantling of BLDC ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and as directed by Engineer In Charge. by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year. |
| 176 | Supply and fixing in repair BLDC fan control electroniccard for 1200 mm sweep ceiling fan as permodel complete all as specified and as directed by Engineer In Charge. |
| 177 | Supply and fixing in repair BLDC fan electronic remotefor 1200 mm sweep ceiling fan as permodel complete all as specified and as directed by Engineer In Charge. |
| 178 | Supply and fixing in repair Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top complete all as specified and as directed by Engineer In Charge. |
| 179 | M&L for the earthing test of through complete all as specified and as directed by Engineer In Charge. |
| 180 | M&L for secure/hanging of electrical XLPE/PVC cable/wires of any size on walls/ceiling with clamps, hooks, nuts , bolts and other accessories for electrical hyigen complete all as specified and as directed by Engineer In Charge. |
| 181 | Supply and fixingin repairs highly efficient high power multi LED flood fitting/Highbay fitting driver of 50 watt to 250 wattsincluding fixing arrangement on wall etc complete including taking downand refixing of existing serviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Surya/Philips/Luckar/CG Note:- To be fixed at min height of 12 m building / store house |
| 182 | Supply and fixingin repairs highly efficient high power multi LED flood fitting/Highbay fitting Inner shell and Combined circuit board of 50 watt to 250 wattsincluding fixing arrangement on wall etc complete including taking downand refixing of existing serviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Surya/Philips/Luckar/CG Note :-To be fixed at min height of 12 m building / store house |
| 183 | Taking down and opening / dismantling of Air circulator , 16 to 24 inch sweep and taking out old unserviceable winding andM & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and re-fixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year. 3. Taken down and refixing at minimum height of building 12 meter. |
| 184 | Supply and fixbush Suitablefor existing Air circulator of 16 to 24 inch sweepcomplete all as specified and as directed by Engineer In Charge. |
| 185 | Supply and fixbearing Suitablefor existing Air circulator of 16 to 24 inchsweep complete all as specified and as directed by Engineer In Charge. |
| 186 | Supply and fixshaft Suitablefor existing Air circulator of 16 to 24 inch sweepcomplete all as specified and as directed by Engineer In Charge. |
| 187 | Supply and fixing in repair mettalic blade Air circulator of 16 to 24 inch sweep complete all as specified and as directed by Engineer In Charge. |
| 188 | Supply and fixing in repair Air circulator lovers of 16 to 24 inchsuitable for any size and model complete all as specified and as directed by Engineer In Charge. |
| 189 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 93,645.00 (Minus) as listed in Schedule of Credit.Note 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\".Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail