| 1 | Wiring point for light point/ fan point/ exhaust fan point/ call bell point / Street light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. [Ps. No. 1.10.3] |
| 2 | Wiring for twin Control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. [Ps. No. 1.11] |
| 3 | Supplying and fixing Suitable size GI Box with modular plate and cover in front on surface or in recess including providing and fxing 3 pin 5/6 A modular Socket outlet and 5/6 A Modular switch connections etc. as required (for plug point). [Ps. No. 1.31] |
| 4 | Supplying and fixing following size modular GI Box along with modular base and cover plate Modular switch in recess etc. as required 3 module (100 mm X 75 mm ( Power plug ). [Ps. No. 1.27.2] |
| 5 | Supplying and fixing following Modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc.as required 6 pin 15/16 A Socket outlet and 15/16 A switch ( Power plug ). [Ps. No. 1.24.3+1.24.5] |
| 6 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required..[Ps. No. 1.38] |
| 7 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)18-22 watt. [Ps. No. 8.11.1] |
| 8 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). [Ps. No. 8.14.14] |
| 9 | SITC of LT Panel vermin proof floor mounting,MS Channel base with bottom and fabricated out of 2.0/1.6 mm thick CRCA Sheet steel,painted with powder coated paint of shade as per directin of Engineer incharg after proper sheet treatment process of sheet steel.The busbar of pannel shall be electrical grade high conductivity alluminum alloy of appropriate cross section as per rating.The main busbar shall run through uot the pannel rating as main incommer rating.The busbar shall be supported by non hygroscopic SMC/DMC Bus bar support witch shall be mounted on proper interval to ensure the bear the jerks of short circuit os 50ka for pannel having acb as incommer& 36 kA for pannel having MCCB incommers.pannel shall be constructed in fully segregated compartmrnt design for each feeder as per 3 b construction format.The pannel shall be completed in all respect as per IS:8623 Part-2&3.There shall be seprate metering compartment for incomer metering and outgoing metering. All incommer feeder shall be provided with multifunction meterin along with phase imcluding light and other associated component such as C.T.,control MCB,Terminal block etc.and all outgoing feeder 100& above shall be provided with 3 phase ameter along with phase indicating and other associated component such as CT control MCB Terminal block etc .the the feeder above shall be provided as accomondated all measuring instrument shall be digital type & all indicating Light shall be LED type.wiring shall be done from 1100 v GradePVC insulated copper flexible wire .All ACB shall be electricaly operated draw out type with microprocesssor based with O/L,S/C&E/F realease breakingb/withstnd capacity(ICU/ICs/ICW )50 ka or more all MCCB shall be thermal magnetic/microprocessor with O/L.& S/C Protectionalong with required spreaders & Extended rotary handle with pad locking facility of breaking capacity (ICU/ICS)36KS or more All MCB Shall br thermal 10KA \"C\" Curve cubicle type switch board shall be CAT-A and B only INCOMING-200Amp.MCCB 1 No. OUTGOING-63 Amp. MCCB 3 No. [Ps. No. 20.1.2. B (ii)] |
| 10 | Supply and fixing of decorative 40 Watt, LED Post top indirect light luminaire Coral NXT PT or GENX PT Havells Make with 5 years warrantee.[Ps. No. A/R] |
| 11 | Supply and laying of Aluminium conductor PVC insulated armoured served sheathed 70 Sq.mm. 3.5 Core cables 1100 Volts grade on wall surface as directed by the Engineer-incharge,complete in all respect including excavation and refilling..The armouring of the cable shall be properly connected with the earth conductor by clamp etc.[Ps. No. 20a.1.13] |
| 12 | Supply and laying of Aluminium conductor PVC insulated armoured served sheathed 25 Sq.mm. 3.5 Core cables 1100 Volts grade on wall surface as directed by the Engineer-incharge,complete in all respect including excavation and refilling..The armouring of the cable shall be properly connected with the earth conductor by clamp etc.[Ps. No. 20 a. 1.10] |
| 13 | Supply and laying of Aluminium conductor PVC insulated armoured served sheathed 16 Sq.mm. 4 Core cables 1100 Volts grade on wall surface as directed by the Engineer-incharge,complete in all respect including excavation and refilling..The armouring of the cable shall be properly connected with the earth conductor by clamp etc.[Ps. No. 20 a. 1.9] |
| 14 | Supply and laying of Aluminium conductor PVC insulated armoured served sheathed 6 Sq.mm. 2 Core cables 1100 Volts grade on wall surface as directed by the Engineer-incharge,complete in all respect including excavation and refilling..The armouring of the cable shall be properly connected with the earth conductor by clamp etc.[Ps. No. 20 a. 1.1] |
| 15 | Supplying and making end termination with of brass compression .gland and Aluminium LUG for 70 Sqmm 3.5 Core PVC insulated & PVC served sheathed/XLPE Aluminium Conductor cable of 1.1 kv grade as required.[Ps. No. 11.1.23] |
| 16 | Supplying and making end termination with of brass compression .gland and Aluminium LUG for 25 Sqmm 3.5 Core PVC insulated & PVC served sheathed/XLPE Aluminium Conductor cable of 1.1 kv grade as required.[Ps. No. 11.1.20] |
| 17 | Supplying and making end termination with of brass compression .gland and Aluminium LUG for 16 Sqmm 4 Core PVC insulated & PVC served sheathed/XLPE Aluminium Conductor cable of 1.1 kv grade as required.[Ps. No. 11.1.33] |
| 18 | Supplying and making end termination with of brass compression .gland and Aluminium LUG for 6 Sqmm 2 Core PVC insulated & PVC served sheathed/XLPE Aluminium Conductor cable of 1.1 kv grade as required.[Ps. No. 11.1.1] |
| 19 | Wiring for Circuit/Submain along with Earth wire with the 2 x 2.5 sq mmand 1 x 2.5 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface/reccssed medium class PVC Conduit as required.[Ps. No. 1.14.2] |
| 20 | Wiring for Circuit/Submain along with Earth wire with the 2 x 4 sq mmand 1 x 4 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface/reccssed medium class PVC Conduit as required.[Ps. No. 1.14.3] |
| 21 | Wiring for Circuit/Submain along with Earth wire with the 2 x 10 sq mmand 1 x 6 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface/reccssed medium class PVC Conduit as required.[Ps. No. 1.14.5] |
| 22 | S&F of 4 ways(4+12) Horizontal type TPN Sheet steel MCBDB 415 Volts on surface/Recess complete with tinned copper bus bar neutral bus bar earth bar din bar inter connection powder pented including earthing etc. as required (but without MCB/RCCB/Isolator)[Ps. No. 2.4.1] |
| 23 | Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)[Ps. No. 2.3.3] |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral[Ps. No. 2.10.5] |
| 25 | Same as above but for Double pole [Ps. No. 2.10.3] |
| 26 | Same as above but for Single pole [Ps. No. 2.10.1] |
| 27 | SITC of 1200 mm sweep. BEE 5 Star rated ceiling fan with Brush Less dc(BLDC) motor,class of insulation B ,3 Nos bades 30 CM long down rod,2 Nos canopies,shackle kit,safety rope,copper winding power factor not less than0.9,service value(CMM/W) Min 6.85,Air delivery Minimum 215 CMM,350 RPM (tolerance as per IS:374-2019),THD less than 10%.remote or electronic regulator unit for speed control and all remaining accessories including safty pin nut bolts,washer,temperature rise=75 degree C (max) insulation resistance more than 2 mega ohm, suitable for 230 volts,50 Hz single Phase AC supply,earthing etc. complete as required.[Ps. No. 9.1.3] |
| 28 | Earthing with G.I. Earth Pipe 4.5 mtr. Long,40 mm dia including accessories and providing masonry endosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.[Ps. No. 5.2] |
| 29 | Providing and Fixing 25 mm x strip on surface in reccss connection as required.[Ps. No. 5.15] |
| 30 | Supply and fixing LED Bulb 12 watt lumen 1080 lm complete in all respect.Havells Make[Ps. No. A/R] |
| 31 | S/F of Fresh air Fan 300 mm sweep model Turbo Force SP 900 rpm make- Havell or as Equivalent.[Ps. No. A/R] |
| 32 | S/F of 380 mm Exhaust Fan Ventil in Sweep Model Havells Make[Ps. No. A/R] |
| 33 | S/F of 200 Amp.415 Volts offload Change over Switch Four Pole Side Handle HNS Code 8536 Model Havells Make.[Ps. No. A/R] |
| 34 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. CEASEFIRE or Equivalent[Ps. No. A/R] |
| 35 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. CEASEFIRE or Equivalent[Ps. No. A/R] Please Enable Macros to View BoQ information |