| 1 | Demolition of cement concrete reinforced in roof/floors other than ground level beam, stair case, landing, chajjas and similar items includingwater proofing treatment in any layersand removal of debris to distance exceeding 500m and not exceeding 1.50 km from the site complete all as specified and directed. |
| 2 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 3 | Formwork to soffits of suspended slabs rough finished surface such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick at any height incl all necessary arrangement (Horizontal or sloping) etc. complete all as specfed and directed. |
| 4 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 5 | M&L for reinforced cement concrete (design mix) M-25(using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specifed and directed. |
| 6 | S/F 10 mm dia and over TMT bars cut to length, bend to shape required including cranking, bending, spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 7 | S/F 6mm to 8 mm dia TMT bars cut to length, bend to shape required including cranking, bending, spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 8 | S/F5mm dia and over upto and including 10mm dia in stirrups, spacers and binders TMT bars cut to length, bend to shape required including cranking, bending, spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 9 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. from wall & ceiling surfaces complete all as specified and directed. |
| 10 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 11 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:4) using old size bricks complete all as specified and directed. |
| 12 | Rendering 10 mm thickin CM 1:6 finshing the surface the even and smooth without using extra cement complete all as specified and directed. |
| 13 | Rendering 15mm thick in two layers on fair faces of brick work or concrete surfaces 10mm in CM 1:6 and top layer 5mm thick in CM 1:4 finshing the surface the even and smooth with using water proofing compound complete all as specified and directed (WPC shall be measured and paid seperately). WPC @ 0.20 Liter per 50 Kg of cement. |
| 14 | M&L for rendering 5mm thick in CM 1:3 as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement complete all as specified and directed. |
| 15 | M&L for preparation of new plastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed. |
| 16 | M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 17 | M&L for reinforced cement concrete (design mix) M-25(using 20mm greaded stone aggregate as in columns, pillars, piers, posts and struts complete all as specifed and directed. |
| 18 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coat of cement base paint on undecorated surface complete all as specified and directed. |
| 19 | Dismantling spelled, unsound and damaged/distressed plaster by scrapping with utmost care to expose reinforcement, cleaning the rusted reinforcement by rubbing with wire brushes or emery paper and disposal of debris not excedding 500 mtr all as specified and directed. |
| 20 | M&L for applying epoxy based bonding materialNitobond EP of FOSROC or equivalent in list of makesover cleaned exposed reinforcement as well as new reinforcement provided for corrosion prevention and fresh plaster bonding to old concrete complete all as specified and directed. |
| 21 | M&L for applying pressure guniting 40mm thick to all affected area of RCC/masonary structure including necessary scaffolding for the height of 5 M from ground using sprayset HBL of Fosroc or equivalent in list of makes @ 5 liters per 100 kg of cement and coarse sand in the ratio of 1:3 as per manufcturer instruction complete all as specified and directed. Note : Spray Set HBL Chemical or equivalent shall be measured and paid under Item No 22 |
| 22 | Supply only Sprayset HBL of Fosroc or equivalent in list of makes complete all as specified and directed. |
| 23 | M&L for epoxy protective coating to steel structural members after proper surface preparation to remove loose dust, dirt, oil liatance etc application of one coat of Nitozinc Primer -epoxy zinc rich coating and application of two coats of Nitocoat EP 405 -Epoxy resin base Micaceous iron oxide coating for steel and concrete using suitable brush or roller at 90 microns DFT etc. complete including all tools ad tackles as per manufacturers specification complete all as specified and directed. |
| 24 | S&F welded steel wire fabric n exc 4 Kg/Sqm fixed with necessary nails/fasteners and mild steel wire not less than 0.9 mm dia etc at wall/floor/slab etc complete all as specified and directed. |
| 25 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 26 | M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection including cutting grooves at every 2mtr interval and fillling with bitumin sand mix complete all as specified and directed. |
| 27 | M&L for rendering 10 mm thickon fair faces of concrete surfacein cement mortar 1:3 for receive the roof finishes with water proofing liquid. (WPL Shall be measured and paid separately) complete all as specified and directed. |
| 28 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( wt not less than 150 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltr/Sqm by torched complete all as specified and directed. Four course roof treatment consists of as under :- (a) Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr per sqm.(b) Laying of APP based membrane as specified thickness and weight.(c)Applying one coat of bitumin grade 85/25 @ 1.2 Kg/Sqm.(d)Applying two coat of aluminium paint @ 200ml/sqm. |
| 29 | Supply only liquid water proofing compound complete all as specified and directed. |
| 30 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduitwith switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 31 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etcincluding modular press steel with cover plate and frame, complete, all as specified & directed. |
| 32 | All as per item No.31.00 (here-in-before)but one Fan/exhaust fan pointcontrolled by one Number one way switch complete all as specified and directed |
| 33 | All as per item No. 31.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. |
| 34 | S&Fmodular type switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed. |
| 35 | S&F modulartype socket outletmultipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 36 | S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple polewith MCB 20 Amp |
| 37 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminalswith back plate etc complete all as specified and directed. |
| 38 | Supply and fixing LED lights fitting 1x 40W, 220V,AC wall mounted aluminium LED batten (4FT)withhigher efficacy & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 39 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 40 | S&F in repair of M.C.B. SPN, 240 Volts, 40 Ampsbreaking capacity 10 KA complete all as specified and directed. |
| 41 | S&F in repair of M.C.B. TPN, 240 Volts,63-100 Ampsbreaking capacity 10 KA complete all as specified and directed. |
| 42 | S&F in repair of sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 43 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed. |
| 44 | M&L in repair of sub main wiring using two single core 6.0 sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing PVC conduit (as required & directed by Engr-in-Charge) accessories like bends, tee, etc. and connecting to earth dolly and including 6.0 sqmm earth wire, PVC insulated & unsheathed all as directed. |
| 45 | M&L in repair of sub main wiring using two single core 1.5 sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing PVC conduit (as required & directed by Engr-in-Charge) accessories like bends, tee, etc. and connecting to earth dolly and including 1.5 sqmm earth wire, PVC insulated & unsheathed all as directed. |