| 1 | Demolition ofbrick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc. complete all as specified & directed |
| 2 | M&L for brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified & directed. |
| 3 | Demolition of cement concrete of ground floor n exc 15 cm in depthin any position nototherwise specifically provided for complete all as specified & directed |
| 4 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg)25 mm thick for Sub base flooring complete all as specified & directed |
| 5 | M&L for Screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed |
| 6 | S&F premium range anti skid matt finish premium range ceramic tiles (as approved by GE) area of each tiles exceeding 0.16 Sqm but not exceeding 0.36 Sqm (thickness as specified by the manufacturer) in flooring set and jointed in premium epoxy grout (Kajaria KE-100 or equivalent) to match the colour of tiles and including laying over cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness bedding on brick/concrete surfaces complete all as specified and directed. (Note: Rates Inclusive of Premium epoxy grout, premium tile adhesive and shall not be paid separately). |
| 7 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed |
| 8 | M&L for rendering 10 mm thick in CM 1:4 for fixing of wall tiles/marble dados finishes complete all as specified and directed |
| 9 | M&L for Ceramic glazed wall tiles including designer/digital/HD/Polished tiles (thickness as specified by the manufacturer), area of each tiles exceeding 0.18 Sqm but not exceeding 0.64 Sqm in flooring set and jointed in premium epoxy grout (Kajaria KE-100 or equivalent) to match the colour of tiles and including laying over cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness bedding on brick/concrete surfaces complete all as specified and directed. (Note: Rates Inclusive of Premium epoxy grout, premium tile adhesive and shall not be paid separately). |
| 10 | M&L for Treatment of soil under existing floors/walls using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors/wall complete all as specified & directed |
| 11 | M&L for 20mm thick black granite stone slab machine cut in cooking platform, jambs, pillars, windows cills, making border/design for floors etc and the like laid over and including 10 mm thick screed bed or backing coat in cement mortar (1:4) and jointedwith grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed. |
| 12 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each complete all as specified & directed |
| 13 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqm each complete all as specified & directed |
| 14 | S & F Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rates inclusive of M.S. hold fast/ lugs or SS dash fasteners). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified & directed. |
| 15 | S & F for 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 16 | S & F 30mm thick 1st class teak hard wood Glazed andskeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars),divided into squares, with plain, chamfered or rounded,mitred and rebated sashbars, any numbers fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats complete all as specified & directed |
| 17 | S&F powder coated anodised aluminium windows sliding (3 shutter type) typewith sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) inclstainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, including S&F 5.50 mm thick black glass complete all as specified and directed. |
| 18 | S&F powder coated anodised aluminium windows/ventilators side hung openable typewith sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) inclstainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, including S&F 5.50 mm thick black glass complete all as specified and directed. |
| 19 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed |
| 20 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed |
| 21 | S&F Brass 300mm sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified & directed |
| 22 | S&F brass barrel tower bolt with bright bolt 200 mm long complete all as specified & directed |
| 23 | S&F 150mm Extruded brass handles, fabricated type polished complete all as specified & directed |
| 24 | S&F 100 mmbutt hinges, medium weight Brass complete all as specified & directed. |
| 25 | M&L fabrication and fixing BWP (Boiling water Proof) solid block Board 19 mm thick conforming to IS 1659- 2004 to be used ,inside depth not less than 0.50 metre. All the exposed surface which are or can be visible to be covered with 1.0 mm th. Sunmica of Approved colour, shade and finish. The surface which will come in contact with wall/ masonary/tiles etc shall be premiered with Appropriate Wood primer mixing Approved Antitermite chemical and pasting 250-micron water proof Plastic Sheet with appropriate adhesive. All the Pastings to be done with water resistant Adhesive. Any Butt joint should be strengthen with Screw and Fissures inserted with appropriate pasting compound. Shutters of storage unit to be formed out of 19 mm thick BWP ply and faced with 1.0 mm thick Sunmica. Provide shelf etc. made of 19 mm thick BWP B.B., polished to engineer-in-charge\"s approval. Complete Including with all necessary fittings like knobs, magnet catcher, running track for sliding, hinges any type, ball catchers, SS tower bolts 150mm , locks,SS handles 300mm long, adjustable shelves etc. as per directions of Engineer Incharge. Inside surfaces to be finished with 1.00 mm thick Sunmica and outer exposed surface with 1.00 mm th. Sunmica. Cupboard depth of 600- 750 mm complete all as specified & directed(Note: 1.Rates inclusive of solid block board, adhesives, fittings/fixtures, Sunmica and plastic sheet etc and shall not be paid separately. 2.Front facing area shall only be considered for payment ) including taking down old boarding any type. |
| 26 | M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified & directed |
| 27 | M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel (by spraying) over one coat of primer complete all as specified & directed |
| 28 | Taking down of cementplaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed |
| 29 | M&L15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. |
| 30 | M&L Rendering 5 mm thickon fair faces of concrete surfaces, finished even and smooth without using extra cement on ceiling in cement mortar (1:3), complete all as specified & directed |
| 31 | M&Lpreparation of newly plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed |
| 32 | M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of oil emulsion distemper white or tinted over a coat of alkali resistant primer complete all as specified and directed. |
| 33 | M&L for preparation of newly plastered surfaces of ceiling and applying two coat of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed |
| 34 | Taking up or down steel tubing and connection 20 mm bore pipe and removing from site complete all as specified & directed |
| 35 | Supplying and laying of CPVC 20mm outer dia pipes SDR 11 & Plain CPVC SDR 11, with all fittings and fixed on walls/ceiling or laying in floors complete all as specified & directed |
| 36 | S&F in repairs bib taps brass chromium plated 15 mm bore size long shank with flange screwed down screwedfor 20 mm dia pipe or for brass ferrule complete all as specified & directed |
| 37 | S&F brass floor door stopper body and tongue with hard drawn steel spring, fixed in floor complete all as specified & directed |
| 38 | S &F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed |
| 39 | S&F in repairs 75mm bore PVCPipes single socketed in any length with rubber ring joints, fixed to walls and floor etc.as in wastecomplete all as specified & directed. |
| 40 | S&F PVC bends 75mm bore, any radius complete all as specified & directed. |
| 41 | S&F in repairsbowl sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe size bowl size 515mm x 515mm x 230mmcomplete all as specified and directed. |
| 42 | S&F in repairs 15 mm dia brass chromium plated Central Hole Basin/Kitchen sink Mixer with Regular Spout with Popup Waste System with 450mm Long Braided Hoses fancy type with or without lettered \"Hot\" or \"Cold\" ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe complete all as specified & directed |
| 43 | S&F in repairs 15 mm dia Concealed stop cock chromium plated cast copper alloy screwed downhigh pressure with crutch or butterfly handle, flenchscrewed both ends for iron or for union complete all as specified & directed |
| 44 | M&L for 18/19mm thick plywood in repair with (including) 0.8mm thick decorative mica fixed on exposed surface and white mica in internal area as inmodular kitchen cabinets, inside depth not less than 0.50 M,water proof, termite & borer proof, corrosion free and auto soft closer couter sunk hinges, stainless steelhandles (buff finished)complete all asspecified and as directed. Note :- 1. Front facing area shall only be considered for payment 2.Thelabour charges for fixing of stainless steel baskets catered under Item No. 2 below shall be included in the quoted rate.3. Rates inclusive of Stain less steel hinges, 180 degree , 304 grade. |
| 45 | Supply only a set of stainless steel baskets(304 grade) with fittings as in modular kitchen cabinet as per following details :-(i)Plate basket21\"x19\"x8\"-01 No.(ii)Plane basket21\"x19 \"x 8\" -01 No.(iii) Plane basket17\"x19\"x8\"-01 No.(iv) Butlery basket17\"x19\"x4\"-01 No. (v) Cup &Saucer basket 17\"x 19\" x4\"-01 No. (vi)Single pull out 8\" -01 No. (vii) GT -PT & Drip tray 22\" -01 No.(viii)Stain less steel Telescopic channels of appropriate size-06 Nos.complete all as specified & directed |
| 46 | M&L for preparation of old or previously untreated wooden surface of any description over 10cm width or girth and applying two coat of synthetic enamel (by spraying) over one coat of primer and putty after complete removal of old treatment complete all as specified & directed |
| 47 | Taking down carefully any type of battens or conduit point wiringwith conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified & directed |
| 48 | M&L for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, sheathed, copper conductor cable in and including PVC concealed conduit of not less than 20mm dia complete with all accessories/fittings, brass screws, washer etc, including modular boxes, modular plates suitable for fixing modular switches/sockets and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, sheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- |
| 49 | All as describd ser no 48.00 here-in-before but one tube light/Bulb/ ceiling fan/ exhaust fan/ security light point controlled by one, one way switch 05 / 06 Amps. |
| 50 | All as describd ser no 48.00 here-in-before butone 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. |
| 51 | All as describd ser no 48.00 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. |
| 52 | All as describd ser no 50.00 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board. |
| 53 | S&F Modular Switch, 1 module, 6A, AC, 240V, one waycomplete all as specified and directed |
| 54 | S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, complete all as specified and directed |
| 55 | S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, complete all as specified and directed |
| 56 | S&F Modular Switch, 1 module, 16A, AC, 240V, one way complete all as specified and directed |
| 57 | S&F of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified and directed |
| 58 | S&F lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed |
| 59 | S&F LED lamp 2 pin 9/10 watt complete all as specified and directed |
| 60 | S&F LED light fitting 1x20/22 watt,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 61 | S&F LED bollard light , 900 MM, 10 watts shaped integral decorative with polycarbonate diffuser with IP65 protection including PVC combined box with socket, complete with all accessories and internally prewired and necessary fixing arrangement including PCC platform by providing GI nuts bolts copmlete all as specified and directed. |
| 62 | S&F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections of cross-sectional area 4 sqmm; 2 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, MS Clamps, Saddles, nuts, bolts and washers etc and testingand including removing old unserviceable item complete all as specified and directed. |
| 63 | S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed |
| 64 | S&F MCB, SP, AC, 240 volts \"C\" curve capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed. |
| 65 | S&FDouble pole Isolator 240V, 40A, and making connections complete all as specified & directed. |
| 66 | M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including taking down old u/s wiring & incl all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. |
| 67 | S&F exhaust fan, steel body, AC single Phase. 230V of size 300mm, sweep with, blades, and frame and louvers, complete all as specified and directed |
| 68 | Taking down existing exhaust fan of any size and keep them safe to deposited to E/M yard complete all as specified and directed |