| 1 | Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed by Engr-in-Charge. |
| 2 | Material and Labour for Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, upto double story complete all as specified and as directed by Engr-in-Charge. |
| 3 | Material and Labour for preparing newly Plastered surfaces of Walls byappying two coat ofExterior Emulsion Anti- Algal weather coat Exterior paint with approved TintaboveExterior wall primer, complete all as specified and as directed by Engr-in-Charge.Note: The painting shall be done through Thread roller as directed by Engr-in-Charge. |
| 4 | Material and Labour for Rendering (External) 15mm thick in Two layers, 1st layer 10 mm thick in CM 1:6 and 2nd layer 5 mm in CM 1:4with WPC on Brick Walls or on Concrete Surfaces, Plastered Surfaces finished Fair and Even, using Integral water proofing compound complete all as specified and as directed by Engr-in-Charge. Note: WPC shall be measured and paid separetely. |
| 5 | Supply and Fixing in repair for 15mm bore Steel water tubing \"medium grade\", galvanised with and including all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. |
| 6 | Supply and Fixingin repair for 20mm bore Steel water tubing \"medium grade\", galvanised with and including all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. |
| 7 | Supply and Fixing in repairRotational Moulded Polyethene Water Storage Tank, 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, conforming to IS, hoisted and fixed in Position complete all as specified and as directed by Engr-in-Charge. |
| 8 | Supply and Fixingin repair Rotational Moulded Polyethene Water Storage Tank, 1000 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, conforming to IS, hoisted and fixed in Position complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply and Fixing for of Gun Metal Gate Valve 20mm bore (dia) with Iron Wheel Headincluding Flange, screwed both Ends for Iron Pipe, complete all as specified and as directed by Engr-in-Charge. |
| 10 | Supply and Fixing for Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe, complete all as specified and as directed by Engr-in-Charge. |
| 11 | Disconnecting existing tanks of capacity exc 250 n exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed by Engr-in-Charge. (Cleaning repairing etc. measured separately). |
| 12 | Disconnecting existing tanks of capacity exc 500 n exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed by Engr-in-Charge. (Cleaning repairing etc. measured separately). |
| 13 | Dismantling of concrete in roof, floors(other than ground floor),beams, staircase, landings, chajja and similar suspended work complete all as specified and as directed by Engr-in-Charge. |
| 14 | Demolition of Brick tiles or terracing tiles,single layer on roofs complete all as specified and as directed by Engr-in-Charge. |
| 15 | Demolition of mud in roofs any thickness and stripping out/ taking down old existing tarfelt, water proofing membrane, any type from roof including plaster/screed bed, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debrisand disposing outside MOD area complete all as specified and as directed by Engr-in-Charge.(NOTE: Debris shall be disposed off outside AF land by contractor under his own arrangementand rate quoted by contractor is deemed to be inclusive of the disposal outside AF Land. |
| 16 | Material and Labour for for PCC 1:2:4 Type B-0 (using12.5 mm graded stone aggregate) as in padding over roof slab laid to slope finished even and smooth, roof kerbs, rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply only Integral Water Proofing Compound, ISI Marked, as approved, complete all as specified and as directed by Engr-in-Charge. |
| 18 | Taking down existing treatment of sunken floor including demolition ofcement concrete of any description and providing cement concrete 1:5:10 in sunken portion. Sunken reatment shall be carried out as described below:-\"Material and Labour for applying Flexible Water Proofing & Protective coating on Floor and Walls of Sunken portion, using Dr. Fixit Pidifin 2K (Two Pack Cementitious Waterproof Coating or equivelent as aproved by GE), comprising with and including the following :-(a)Rendering/Plastering 15mm thick on Brick, Concrete surfaces in Cement Mortar1:3, finishing plastered surfaces Even and Smooth without using Extra Cement.(b)Applying Two Coats of Dr. Fixit Pidifin 2Kor equvilent as approved by GE @ 1.50 KG/SQM Each Coat on dried Plastered surfaces by a Masomary Brush or an appropriate Powder Spray equipment. Second Coat shall be applied when the First Coat is completely dried.(c ) Taking down existing spout pipe of any description and proving 400mm long GI pipe of 25mm dia. |
| 19 | Supply and Fixingin repairs Vitreous China White Squatting Pan of size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incluiding provision Concrete Bedding and Making Good to distrubed surfaces , complete all as specified and as directed by Engr-in-Charge. |
| 20 | Supply and Fixingin repair Angular Stop Cock fancy type with wall flange 15mm bore (dia) complete all as specified and as directed by Engr-in-Charge |
| 21 | Material and Labour for in repairs PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, Flush Pipe of polyetylene of high density or PVC 32 mm dia for low level cistern of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted with and including cutting and pinning in Ends, Making Good Disturbed Surfaces in CM 1:3, complete all as specified and as directed Engr-in-Charge. |
| 22 | Supply and FixingPVC Connection Pipe 15mm size and 45 Cm in length with Adopter Nuts of PVC, complete all as specified and as directed by Engr-in-Charge. |
| 23 | Supply and Fixing in repair PVC (SWR) Floor Trap 75mm bore (dia) with Grating including jointing to Waste Pipe fixed in Cement Concrete 1:2:4 (20mm graded stone aggregate) and fixed-in-repairs, complete all as specified and as directed by Engr-in-Charge. |
| 24 | Supply and Fixing inrepair PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors and Fixed-in-repairs, complete all as specified and as directed by Engr-in-Charge. |
| 25 | Supply and Fixing inrepair Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Short Body with Capstan Head, screwed down, screwed for Iron Pipe or for Brass Ferrule , complete all as specified and as directed by Engr-in-Charge. |
| 26 | Material and Labour forcleaning of surfaces properly to remove any dirt, dust or loose particles and applying elastomeric waterproof coating on inaccesible roofs, terraces and parapets (having minimum 105 SRI value), in three coats with and (including one primer coat at specified intervals to achieve an overall thickness 0.40-0.50mm including curing, finishing and testing complete all as specified and directed. NOTES:(Item No 26 & 27)1) The work and mix proportion of items shall be carried out strictly as per manufacturer\"s recommendations.2) Contractor shall submit details alongwith technical literature of various items required for the job for prior approval of GE.3) Quoted rate shall deemed to include for all consumbles, scaffolding and safety gear required for satifactory completeion of the job.4) Cost of waterproof coating, GSM/HDPE sheet, screed bed, tiles and epoxy grout shall deemed to be included in the quoted rate. |
| 27 | Material and Labour for for cleaning of surfaces properly to remove any dirt, dust or loose particles and applying elastomeric waterproof coating on inaccesible roofs, terraces and parapets (having minimum 105 SRI value), in three coats with and including one primer coat at specified intervals to achieve an overall thickness 0.40-0.50mm including curing, finishing and testing complete all as specified but applying elastomeric waterproof coating on accesible roofs and terraces in the following chronological order complete all as specified and as directed by Engr-in-Charge :-(i) cleaning of surfaces properly to remove any dirt, dust or loose particles(ii) applying elastomeric waterproof coating in three coats with and(including one primer coat) at specified intervals to achieve an overall thickness 0.40-0.50mm.(iii) Supplying and laying a layer of 120 GSM non-woven geo textile or 250 micron HDPE sheet (as directed by Engineer-in-Charge) over the treated surface.(iv) Supplying and laying ceramic roof tiles, 10mm thick, of approved shade, over and including 10 mm thick screed bed with polymer modified cement mortar, tiles fixed with spacers to provide provide a uniform spacing of 3mm between the tiles and after setting of screed bed and tiles, removing the spacers and filling the joints with suitableepoxy grout and pointed with grout complete all as specified and directed by Engr-in-Charge.NOTE : Cost of waterproof coating, GSM/HDPE sheet, screed bed, tiles and epoxy grout shall deemed to be included in the quoted rate. |
| 28 | Material and Labour for Non-skid Coloured Ceramic joint free Tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqmin Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over with and includingScreed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed Cost of waterproof coating, GSM/HDPE sheet, screed bed, tiles and epoxy grout shall deemed to be included in the quoted rate.. |