| 1 | Dismantling unserviceable LT RCC pole /struts, any size of any description and including demolition of Cement Concrete (as/if required) and made good disturbed Ground complete all as specified and as directed. |
| 2 | Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc complete all as specified and as directed. |
| 3 | Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size complete all as specified and as directed. |
| 4 | Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer etc complete all as specified and as directed. |
| 5 | Dismantling Earth Wire, Cradle Guarding etc complete all as specified and as directed. |
| 6 | Dismantling unserviceable stary assembly of LT Pole complete all as specified and as directed.Note : Unsv Stay assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. |
| 7 | M&L for repairs/replacement of stay assembly with accessories as shown in electrical plate No.1 complete with diamter of stay Rod 20 mm inclusive of loop type insulators, stay clamps including dismatling of old unserviceable stay assembly, loop insulators, stay rod complete including demolition of existing concrete complete all as specified and as directed.Note :- Excavation, earth work will be measured and paid seperately |
| 8 | M&L for steel tubular poles of street light complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long including painting all external exposed steel surfaces with two coats of aliminium paints over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bitumenous paint complete all as specified and as directed. |
| 9 | M&L for PCC 1:4:8 type C2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and as directed. |
| 10 | M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc (around the poles in pit) complete all as specified and as directed. |
| 11 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping including necessary framework, finished fair using exta cementcomplete all as specified and as directed. |
| 12 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundations of poles etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/ loose soil complete all as specified and as directed. |
| 13 | Excavating in trenches,exceeding 1.5 m wide and exceeding 1.5 m in depth for foundations of poles etc and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and as directed. |
| 14 | Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 15 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 16 | M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and as directed. |
| 17 | Supply and laying sub class B bricks of size230x125x73mm(+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 18 | Laying only old burnt old sizebricks,straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and as directed. |
| 19 | M&L for Horizontal boring suitable for 80mm bore steel tubing, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through up to 80 mm bore, galvanised steel tubing complete all as specified and as directed. |
| 20 | S&F for Galvanised mild steel pipe/ tubing,light grade complete with all fittings of 80 mm bore dia, laid in trenches/ under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 21 | S&F for Galvanised mild steel pipe/ tubing,light grade complete with all fittings of 40 mm bore dia, laid in trenches/ under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 22 | S&F for Galvanised mild steel pipe/ tubing,light grade complete with all fittings of 25 mm bore dia, laid in trenches/ under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and directed. |
| 23 | Taking out oldcable of any 10 Sqmm x 2 core/10 sqmm x 4 Core from trenches, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed.Note :The Excavation and earth work shall be mesured and paid separately under relevant item of Sch. |
| 24 | Relaying only LT cable of any type retreived from item No- 23 , after rectifing defects complete as specified and as directed.Note : Earth work & Excavation, GI pipe, brick protection etc shall be measured and paid separately under relevant items of this schedule. |
| 25 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 240 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, nut, bolts, washer etc complete all as specified and as directed. |
| 26 | All as per ser item No 25 above but of cross sectional area 95 sqmm 3.5 core complete all as specified and as directed. |
| 27 | All as per ser item No 25 above but of cross sectional area 185 sqmm 3.5 core complete all as specified and as directed. |
| 28 | All as per ser item No 25 above but of cross sectional area 150 sqmm 3.5 core complete all as specified and as directed. |
| 29 | All as per ser item No 25 above but of cross sectional area 35 sqmm 3.5 core |
| 30 | All as per ser item No 25 above but of cross sectional area 25 sqmm 4 core complete all as specified and as directed. |
| 31 | All as per ser item No 25 above but of cross sectional area 16 sqmm 4 core complete all as specified and as directed. |
| 32 | All as per ser item No 25 above but of cross sectional area 10 sqmm 4 core complete all as specified and as directed. |
| 33 | All as per ser item No 25 above but of cross sectional area 10 sqmm 2 core complete all as specified and as directed. |
| 34 | S&F in repair of HOT moulded (FRP) SMC jucntion box for street light pole with locking arrangementt hinged door with IP -65 protection of size 205 x 255 X 112 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and as directed. |
| 35 | S&F for unplasticised PVC pipes with fittings of pressure rating 10kgf/cmSq of 20 mm bore and 3mm thick fixed with MS flat iron clamp of size 20X3 mm in every 1.5 meter length of pipecomplete all as specified and as directed. |
| 36 | S&F for 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and as directed. |
| 37 | M&L for tree trimming cut away dead or excess branches from trees or shrubs to maintain clearance along with over head power lines using climbing equipment and collecting the debris for disposal and removing broken limbs from electric wires by using hooked extension poles complete all as specified and as directed.Notes:-Span is taken as distance between two adjacent poles. |
| 38 | Supply, install, testing and commissioning of LT Indoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.50m x 0.9m x 0.5m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 45X45X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement ,louvers at sides & duly powder coated includingin-panel CO2/Clean agent fire suppressing system complete for accomodating & including following accessories:-DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts 200 amps 36 KA - 01 No.(ii) On load change over switch 160 Amps -01 No. OUTGOING: (i) MCCB 4 Pole ,415 Volts with breaking capacity36 kA of capacity 125 Amps with thermal magnetic release -02 Nos (01 Spare)(ii) MCCB 4 Pole ,415 Volts with breaking capacity25 kA of capacity 40 Amps with thermal magnetic release -02 Nos(01 Spare) |
| 39 | (iii) MCB SPN 40 Amps,240 Volts with breaking capacity 10 kA -02 Nos(iv) Street Light Timer switch 230 V single phase of 20 Amps with contactor - 01 Nos BUSBAR:(i) Cupperbus bar 300 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 Nos INDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii)Digital ampere meter of 0-400 A, 3 phase, class 1 , including CT having CTR 400/5 - 01 No(iii)Digital voltmeter 0-600 Volts, 3 phase, class 1, - 01 NoNote : (i) Cost of earth work and PCC are deemed to be inclusive in this item.(ii) The GA drg of LT pannels shall be approved by GE before procurement. |
| 40 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 900 mm x 45 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 300 x 700 x 400 mm . Danger notice plate shall be fixed on main door. The pannel shall be Complete painted with Powder Coated paint of approved shade. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundationcomplete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 41 | Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item(ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming)(b)Copper busbar 300 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 200 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 40 amps including all fixing accessories with both ends spreader links . ( Outgoing -04 Nos) (e) MCB SPN 40 Amps,240 Volts with breaking capacity 10 kA -03 Nos (f)Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (j) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB. |
| 42 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 900 mm x 45 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 300 x 700 x 400 mm . Danger notice plate shall be fixed on main door. The pannel shall be Complete painted with Powder Coated paint of approved shade. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundationcomplete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 43 | Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item(ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming)(b)Copper busbar 300 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 200 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos)(d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 40 amps including all fixing accessories with both ends spreader links . ( Outgoing -04 Nos) (e) MCB SPN 40 Amps,240 Volts with breaking capacity 10 kA -03 Nos(f)Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (j) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB. |
| 44 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1000 mm x 700 mm x 450 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 300 x 700 x 400 mm . Danger notice plate shall be fixed on main door. The pannel shall be Complete painted with Powder Coated paint of approved shade. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundationcomplete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 45 | Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a)Copper busbar 300 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming)(b)Copper busbar 200 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 40 amps including all fixing accessories with both ends spreader links . ( Outgoing -03 Nos) (e) MCB SPN 40 Amps,240 Volts with breaking capacity 10 kA -05 Nos(f)Neon indicator lamp with holder (RYB) = 03 Nos(g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (j) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 46 | Supply, fabrication, installation and testing of LT out door type factory made, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.(a)Copperbus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 47 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.30 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. |
| 48 | M&L for heat shrinkable straight through joints suitable for LT PVC / XLPE insulated armoured aluminium conductor cable of size 10 sqmm to 50 sqmm, 2/3.5/ 4 core with jointing accessories including cutting of faulty cable complete all as specified and directedNote: (i) Cutting of faulty cable/ joint is deemed to be included in the above quoted rates.(ii)If old burnt/ damaged LT cable/joint retrieved will be issued to contractor as schedule of credit.(iii)Excavation and returning/filling required for straight through joints will be included in the quoted rate. If the excavation required more than 15 RM for joint of cable than it will be measured in respective item. |
| 49 | All as per item No. 44.00 above but cable of size 70 to 150Sqmm complete all as specified and directed |
| 50 | S& F in replacement of MCCB, TPN250 Amps, 36kA breaking capacity with overload and thermal tripping features, 415 volts, AC, 50 Hz complete with suitable spreader complete all as specified and directed Note: Minor addition and alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate. |
| 51 | M&L for PCC root indicator suitable for mounting on root of HT/LT cable of width 45cm, depth 10 cm & height 100 cm overall embedded to the depth not less than 45cm below ground level with marking of type of cable & size complete all as specified and directed |
| 52 | Demolition of brickwork or stone/boulder masonary, built in cement mortar or cement lime including all quoins, arches,pillars, etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed. |
| 53 | M&L for brickwork with sub class \"B\" bricks,straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 54 | M&L for 25 mm thick cement concrete type B-1,1:2:4 (20mm graded stone aggregate) in floors,paving etc complete all as specified and directed. |
| 55 | M&L for rendering 15mm thk on fair faces of brick work or concrete surfaces in cement mortar1:4 and mixing of water proofing compound @ rate 3% of weight of cement complete all as specified and directed.Note:- Water proofing compound will measured and paid separately. |
| 56 | Supply integral water proofing compound complete all as specified and directed. |
| 57 | M&L for rendering 10mm thk on fair faces of brick work or concrete surfaces in cement mortar1:6 complete all as specified and directed. |
| 58 | Demolition of concrete in ground floorsand paving n.exc 15 cm thickness (below or above the ground level) complete all as specified and directed. |
| 59 | M&L for plain cement concrete 100 mm thk 1:4:8 type D2 (using 40 mm graded stone aggregate) crushed stone aggregate as in sub floors, sub bases, floors and paving etc complete all as specified and directed. |
| 60 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 61 | M&L for cement concrete Type C-1, 1:3:6 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 62 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |