| 1 | Excavation in trenches for laying of cable trench, pole and stay foundation in any type of soft/loose soil not exceeding 1.5 mtr wide and not exceeding1.50 mtr deep and getting out . |
| 2 | Material and labour for sand cushioning with dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 3 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type- 1flat, size 250mm x 150mm x 40mm, complete all as specified and directed. |
| 4 | Returning filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick. |
| 5 | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 6 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 4.0 sq mm, 4.0 core including testing after laid and jointed all as specified and as directed. Make: Havells/ Polycab/ KEI. |
| 7 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 2.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed in wall/ceiling orsurface of wall/ceiling as directed including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 2.50 sqmm pressed steel modular boxessunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular coverwith frame any size complete all as specified and making good disturbed surfaces for one6 A socket point controlled by one, one way switch. Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate.All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 8 | All as per item no 01 above but submain of size 2 x 1.5 sqmm with earth wire of size 1 x 1.5 sqmm |
| 9 | As per item No 1 abovebut One 3 pin 5 amp socket out point on the same board with other switches. |
| 10 | All as per item Sl No 1here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 16 amps power point. |
| 11 | Supply and fixing for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 12 | Supply and fix Modular switch one way 16A, 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 13 | Supply and fix Modular Socket 6A 3 pin combined 2 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 14 | Supply & Fix Modular Socket 6A/ 16A3 pin combined 2 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 15 | S & Fix 3modulepolycarbonate box withcover plate andframe for munting of switch and socket or dummy plate if required complete all as specified and directed. (switch and sockets will be paid seperately as S & F) |
| 16 | All as item no 8 above but Modular box with modular cover plate with frame 4 module complete all as specified and directed. |
| 17 | All as item no 8 above but Modular box with modular cover plate with frame 6 module complete all as specified and directed. |
| 18 | Supply and fixing ceiling rose, surface type, three terminals 5 amps, complete all as specified and directed. |
| 19 | Supplying and fixing 20 Watt LED Tube light fittings completewith polycarbonate body including tube rod, driver with not less than 2000 Lumen O/P andI/p rated voltage 240V, 50 Hz color temp 6500 K, THD<10%, PF not less than 0.9 and surge protection upto 2.5 KV connecting with3 core 1 sqmm copper conductor cable complete all as specified and directed. |
| 20 | Supply and fix building security lightLED25 W with Lumen O/P 2500 with driver withrated voltage 240 V, 50Hz,color temp 5700 K, PF not less than 0.9 , THD< 10% including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc. complete all as specified and directed. |
| 21 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as directed by the Engineer-in-Charge.Make-Legrand/ L&T/ Havells/ |
| 22 | Supply and fix MCB single pole & neutral 240 volt 32 amps 10 KA, complete all as specified and directed. |
| 23 | Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA, complete all as specified and directed. |
| 24 | Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b)PCC pit in cement concrete 1:2:4 TYPE B-1 (.c)Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d)Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e)15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f)Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |
| 25 | Supply and fixing in replacement 1100 volts grade heavy duty cablePVC insulated aluminiumconductor, 4 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspendedby insulating hangers notmore than 1 metre apart including 4mm suspension wire. |
| 26 | All as per item No. 25 but6 sqmm 2 core, all complete as specified and directed. |
| 27 | All as per item No. 25 but10 sqmm 2 core, all complete as specified and directed. |
| 28 | S & F in replacement 1100 Volts grade Copper conductor, PVC insulated, round sheathed (flexible), industrial cable, 1.5 sqmm 3 core. |
| 29 | Supply and fixing in replacment Automatic Load Transfer Switch Changeover 63 Amps, 4 Pole with CM 331 Controller,415 Volts, with 16 A DP MCB for protection with all all control wiring , incoming and outgoing connection with cablelugs, washers, nutbolts, Sheet Enclosure Box(2mm thick sheet ) which is suitable of outdoor and accessories complete with taking down old unserviceable changeover switch all as specified and as directed. |
| 30 | All as per item No. 29 butAutomatic Load Transfer Switch Changeover 100 Amps, all complete as specified and directed. |
| 31 | S&F in replacement ONLOAD Changeover switch 320 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 32 | All as per item No. 31 but ONLOAD Changeover switch 200 Amps all complete as specified and directed. |
| 33 | All as per item No. 31 but ONLOAD Changeover switch 100 Amps all complete as specified and directed. |
| 34 | All as per item No. 31 but ONLOAD Changeover switch 63 Amps all complete as specified and directed. |
| 35 | Supply, fixing and testing in replacement of Automatic Street light Timer Switch using combination ofNATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protection of capacity 12 KW 3 phase, current range 40 Amps, 4 wire (3 separate power contactor) including all accessories and fixing arrangement all as specified and directed. |
| 36 | Supply and fixing in replacement of Contactor oftype MU-2P series (rating 16 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed. |
| 37 | Supply and fixing in replacement of Contactor of Freedom series, 3 pole (rating 18 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed. |
| 38 | Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar fo size 30 cm x 30 x 45 cm in ground with and including necessary foam work and making on board MES LT Cable (1100 Volt) with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed. |
| 39 | M&L for loose filling with aggregate of gauge 20 mm crushed stone back colour suitable for spreading in electrical sub stn after preparation site by removing all type of debris, removing unwanted soil, and spreading lime powder beneath the aggregate all as directed. |
| 40 | M&L for preparing surfaces of electric poles of any type of following sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat ofprimer and two coat of aluminium paint completely, alternate layer of yellow and black paint of 150 mm strip at the bottom of pole 1.5 mtr above coping with synthetic enamel paint all as specified and as directed by Engineer-in-Charge.(a) Height ofrail /tubular poles exceeding 7.5 Mtrs upto 11 Mtrs above ground level. |
| 41 | All as per item No. 40 but height of steel tubular poles 7.5 Mtrs above ground level . |
| 42 | M&L for preparing surfaces of electric poles of RCC type of anysizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of weather proof paint completely andalternate layer of yellow and black synthetic enamelled paint of 150 mm strips at the bottom of pole 1.5 mtr above coping all as specified and asdirected. |
| 43 | M&L for preparing surfaces of electric Two pole Structuresof any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly, MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely as directed. |
| 44 | M&L for preparing surfaces of electric Four pole Structuresof any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly, MS clamps,brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely as directed. |
| 45 | M&L for writingpole No. with letters of size 25 mmheight on pole/ plate withBlack synthetic enamelled paint complete all as specified and directed. |
| 46 | Supply and fixing of 3M Scotchlite Reflective Tape of width 50 mm, water proof, for alternate layer of yellow and black / red tape 300 mm from bottom of pole upto 1.5 mtr above, compete all as specified and directed. |
| 47 | M&L for Spray painting to existing LT Panel of any capacity / size / type including mounting anglewith two coats of approvedcolour synthetic enamel paintcomplete includingdusting, cleaning of existing dust before applying synthetic enamel paint and writing feeder name with approved colour synthetic enamel paint complete all as specified anddirected. |
| 48 | Cleaning of sub station area by uprooting all types vegitation, shrubs, weeds, saplingsand creepers of unwanted trees complete with the help of spade, axes, crowbars, and thereafter chemical spraying will be done and other mechanical means after taking necessary electrical shutdown from concerned incharge of various sub stns of Military Stn Kamptee. |
| 49 | Trimming of tree branches touching of Over headElecctrical Lines upto 2.5 mtr distance from conductors after taking necessary shutdown from concerned incharge all as directed . (Note : Space between two poles will be measured as distance in RM irrespective of nos of conductors). |
| 50 | Materials and labour as in replacement for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, washers of galvanized ironand connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40 mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1(d) 40 mm thick Pre-cast RCC cover with suitable handle.(e) Funnel with watering pipe of GI 20 mm nominal bore ,mediumgrade & copper lug etc. (f) 40 mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead.(g) Requisite quantity of charcoal and common salt.(h) Connection to earthing test point and testing on completion. |
| 51 | Material and labour for transformer platform of size 2.5m x 2.5m x 1.6m height ( 0.6 m below ground level and 1.0 mtr above ground level) comprising of PCC M-7.5 grade (nominal mix) using 40mm graded crushed stone aggregate as in foundation brick work of one brick thick using old size brick in cement mortar 1:6, rendering 15mm thick in cement mortar 1:4 on all exposed brick surface finished smooth using extra cement, filling in approved earth, providing 150mm thick slab M-25 grade (nominal mix) on top reinforced with 12mm dia TMT bars and finishing top surface with 15mm thick plastering in cement mortar 1:4 finished even and smooth using extra cement, including GI pipe light grade 80mm dia of suitable height for cable protection on LT and HT side, white washing of transformer plinth and including suitable brick steps one side of the platform to reach on the platform, details of transformer to be provided on transformer plinth on GI plate, including earthwork,complete all as specified and directed.Note:- Excavation and earth work and PCC shall be included in quoted rate. |
| 52 | M&L for Diesel Generator Set platform of size 4.0 m x 2.25 m x 0.70 m height comprising of PCC 1:2:4 grade (nominal mix) using 40mm gradred crushed stone aggregate in foundation, providing 150mm thick hardcore of broken stone or boulders of gauge n exc. 63 mm and 150mm thick RCC slabM-25 grade (Nominal Mix) on top reinforced with 12mm dia TMT bars and finishing top surface with 15mm thick plastering in cement mortar 1:4 finished even and smooth using extra cement complete all as specified and directed.Note:- (excavation and earth work and PCC shall be Included in quoted rate). |
| 53 | Material & labour and T&P for disconnecting Cable connections, shifting of Transformer / DG Set, installing, testing and commissioning of Transformer / DG Set Outdoor/Indoor typeof any capacity from one location to other location within the defence land (Kamptee and Nagpur) complete all as specified and directed.Note : Cost of materials required for connecting, commissioning and testing of Transformer / DG Set shall be deemed to be included in quoted rate. |
| 54 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.)[(-) Rs. 31,292.00] |