| 1 | Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. (upto 12 storey High of building) |
| 2 | Demolition of Brickworkquoins,arches,pillars etc but excluding ashlar facings,dressed all store work and precast concrete articles built in cement mortar complete all as specified and directed.(upto 12 storey High of building) |
| 3 | M&L for brick work with sub class \"B\" bricks built in cement mortar (1:6) straight or curved on plan exceeding 6 mtr mean radius and complete all as specified and directed.(upto 12 storey High of building) |
| 4 | M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.(upto 12 storey High of building) |
| 5 | Demolition of RCC (reinforcement) of any description and in any position not otherwise specifically provided for complete all as specified and directed.(upto 12 storey High of building) |
| 6 | M&L for RCC forM 20 (Design Mix)using 12.5 mm graded crushed stone aggregateas in parapets, balcony andsimilar work complete all as specified and directed.(upto 12 storey High of building) |
| 7 | Use and waste offormwork to chullah hoods, chajjas, troughs, parapets and similar items including edges for rough finished surface complete all as specified and directed.(upto 12 storey of building) |
| 8 | Dismantling removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached all various locations in building (upto 12 storied) subsequently cleaning the surfaces by hair brush and air blower and removing rubbish off the premises and disposing at the dumping site as approved by local authorities including hoisting assembling and fixing of double layer steel scaffolding to external perimeter of building complete all as specified and directed Upto 12 storied Bldg |
| 9 | Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm(but not less than 15mmair gap)by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemicalon rusting steel reinforcement bar and removing all rust from steel reinforcement barby emery paper and cleaning the area thoroughly by water and allow it to dry andtotally rust free of reinforcement bar all as completeas per manufacturer\"s instruction as specified (upto 12 storied bldg). Make( Rust removing chemical ):- Reebaklens RR of FOSROC or equivalents solutions SIKA/STP. |
| 10 | Removing of concrete all around reinforcement bar above 12 mm dia and over from behind the reinforcing bars average 25mm(but not less than 15mmair gap)by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemicalon rusting steel reinforcement bar and removing all rust from steel reinforcement barby emery paper and cleaning the area thoroughly by water and allow it to dry andtotally rust free of reinforcement bar all as completeas per manufacturer\"s instruction as specified (upto 12 storied bldg). Make( Rust removing chemical ):- Reebaklens RR of FOSROC or equivalents solutions SIKA/STP. |
| 11 | Material , labour and preparation of existing reinforcement surface by brushand application of two component epoxy zincrich primeron existing reinforcement surface ofminimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2and maximum coverage area 5.00 Sqm per litre. complete all as specified and directed.(upto 12 storied bldg). Make- Nitozinc primer of FOSROC or equivalents make as approved by GE |
| 12 | M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified and directed. (upto 12 storied bldg) |
| 13 | Material and labourfor introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified and directed.(upto 12 storied bldg) |
| 14 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. (upto 12 storey High of building) |
| 15 | S&F TMT bars 8 mm dia and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.(upto 12 storey High of building) |
| 16 | M&Lforsupply,mixingandplacementofmicro-concretecementbasedprepackedsingle component chloride free, sulphate free, non-shrink, free flow. elf compacting, ready to use after mixing water in specified proportion of Sika Rep Microconcrete-4 or renderoc-RG of Fosroc in required thickness as per manufacture\"s instruction and all as directed. Compressive strength (ASTN C 109,cm cube) of 35 MPa at 28 days including application curing compound concrete WB manufactured by Fosroc of equivalent at various locations in Bldgs including necessary form work with complete all as per manufactures specification complete all as specified and directed.(upto 12 storied bldg) |
| 17 | M&L for providing and applying at two component structural grade polymer modified reinforcement mortar Fosroc Renderoc S2 or equivalent product of SIKA upto a thickness of 30 mm over a coat of epoxy resin bonding agent Nitobond EP. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in a day & 45 N/mm2 in 28 days with Flexural strength 8N/mm2 in 28 days Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. in addition to this percentage of water absorption should be 0.45 after 24 hours in immersion test at various locations in Bldgs complete all as per manufacture\"s specification.(upto 12 storied bldg) |
| 18 | M & L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete for drilling suitable holes in RCC Slab/ wall/ column/ beams toa depthas directed for anchoring steel reinforcement bars including washing with water inserting lokfix \"E\" of Fosroc or equivalent in the holes at various location in Bldgs complete all as per manufactures specification. |
| 19 | Supply and Application Cementitious Grouting Admixture with the Cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a Pressure grouting Pump through non return PVC nozzles Prefix with rapid setting cementitious Plugging Mortarto fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface complete all as specified and as directed3(upto 12 storey)( Make :- Fosroc/Elantas beck/Kunal conchem) upto 12 storied |
| 20 | M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and directed upto 12 storey High. |
| 21 | Providing of double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly alignede for the functional aspect and safe of the building upto and including45 M hieght complete all as specified and as directed. |
| 22 | Material and labour for rendering 15 mm thick on fair faces of brick work in cement morter (1:4) finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 23 | All as per item No 22 here in before other then fair faces of brick work or on one side of lathing complete all as specified and as directed. |
| 24 | M&L for Rendering 15mm thick in CM (1:6) onother than fair face of brick work or concrete surfacesand finished the surface even and smooth without using extra cement complete all as specified and directed.(upto 12 storey High of building) |
| 25 | M&L for Rendering 5mm thick with CM (1:3) on or concrete surfaces and finished the surfaceeven and smoothas in ceiling complete all as specified and directed.(upto 12 storey High of building) |
| 26 | M&L for preparation of new plastered surfaces and applying one coat white cement based wall care putty (2mm thick) and one coat alkali resistant primer, sanding the surfaces and finally applying two coats of Anticarbonation paint complete all as specified and as directed.(upto 12 storey of building).Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work. |
| 27 | M&L for complete removal of existing old surfaces of wall and preparation of old or previously untreated surfaces and applying one coats white cement based wall care putty ((2mm thick) and one coat alkali resistant primer,sanding the surfaces and finally applying two coats of Anticarbonation paintcomplete all as specified and as directed.upto 12 storied.Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work |
| 28 | Material and labour for new plastered surfacesof wall and preparation of surfaces andone coat alkali resistant primer and 2mm thick cement base wall care putty , sanding the surfaces andMaterial & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives1.43 litre/ 10 sqm over upto 12 storied building complete all as specified and as directed. |
| 29 | Material and labour for complete removal of existing old surfaces of wall and preparation of old or previously untreated surfaces andone coat alkali resistant primer, and 2mm thick cement base wall care puttysanding the surfaces andMaterial & Labour for applying Two or more coatsof 100% Premium acrylic emulsion painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives1.43 litre/ 10 sqm over upto 12 storied building complete all as specified and as directed. |
| 30 | M/L preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed.(upto 12 storey High of building) |
| 31 | M/L preparation of old surface and applying one coats of white wash on ceiling to match with the new one complete all as specified and as directed.(upto 12 storey High of building) |
| 32 | M/L preparation of new plastered surface and applying two coats ofdistemperoil emulsion over a coat of primer complete all as specified and as directed.(upto 12 storey High of building) |
| 33 | Material and labour fo complete removal of existing surface of old plastered surfaces and applying one coat of acrylic washable distemper on walls complete all as specified and as directed. (upto 12 storey High of building) |
| 34 | Taking down steel window/ventilator including guard bar of any description and in any position and removing from site complete all as specified and directed. upto 12 storied bldg. |
| 35 | Supply and fixing in repair powder coated aluminumventilator (single leaf single shutter) side hung type with stainless steel butt hinges, one shutter glazed with and including 4.00mm thick plain sheet glass and other shutter with stainless steel wire cloth of 0.36 mm dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples, rubber gasket, stopper,aluminium anodised handle 100mm long ,aluminium anodised tower bolts 100mm longand peg stay etc, size of aluminum frame shall be (100mmx50mmx1.50mm) and shutter frame shall be (40mmx20mmx1.50mm) complete all as specified and directed upto 12 storied bldgNote : 1 No Glazed shutter and 1 No Gauged shutter constitube one unit. |
| 36 | Hacking out old/broken glass (any description, size and quality) upto 12 storied bldg complete all as specified and as directed |
| 37 | supply and fixing for 3mm thick Sheet glass, ordinary quality and glazing with oil putty insquare n.exe 0.50 Sqm in each pane complete upto 12 storied bldg complete all as specified and directed. |
| 38 | supply and fixing for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty insquareexe 0.50 Sqm in each pane complete all as specified and directed upto 12 storied bldg. |
| 39 | supply and fixing for 4mm thick figured glass, ordinary quality and glazing with oil putty insquaren .exe 0.50 Sqm in each pane upto 12 storied bldg complete all as specified and directed. |
| 40 | Dismantling cast iron or re-inforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and directed.(upto 12 storey High of building) |
| 41 | Taking down eaves gutters and rainwater pipes (any size orpattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixingor removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.(upto 12 storey High of building) |
| 42 | S&F CI spun pipes with out ears in any length fixed to wall with brackets of 100mm bore including bitummouspaints both sidecomplete all as specified and directed.(upto 12 storey High of building) |
| 43 | S&F CIbend with door of 100mm bore complete all as specified and directed.(upto 12 storey High of building) |
| 44 | S&F CIbranch pieces single equal or unequal with door of 100mm bore complete all as specified and directed. (upto 12 storey High of building) |
| 45 | S&F CIcowl of 100mm bore complete all as specified and directed.(upto 12 storey High of building) |
| 46 | S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and directed.(upto 12 storey High of building) |
| 47 | S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified and directed.(upto 12 storey High of building) |
| 48 | Supply and fixing110 mm dia PVC (SWR) junction single, (singleT), equal or unequal fixed to wall upto any height of the building complete all as specified and directed.(upto 12 storey High of building) |
| 49 | S&F 75mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and directed.(upto 12 storey High of building) |
| 50 | S&F 75 mm bore PVC(SWR) pipe bend single socket complete all as specified and directed.(upto 12 storey High of bldg) |
| 51 | Supply and fixing75 mm dia PVC (SWR) junction single, (single T), equal or unequal fixed to wall upto any height of the building complete all as specified and directed.(upto 12 storey High of building) |
| 52 | Dismantling Galvalume Iron corrugated sheet of any guage, thickness complete all as specified and directed (upto 12 storey High of building) |
| 53 | Supply & Fixingfor Pre painted galvalume aluminium zinc coating GI based partially/ fully corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/chadding to wall, fixed with self tapping screws complete all as specified and directed.(upto 12 storey High of building) |
| 54 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.(upto 12 storey High of building) |
| 55 | Material & labour for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings;framework of water tanks and similar work con- forming to Fe.290.Gde-E-16 complete all as specified and directed.(upto 12 storey High of bldg |
| 56 | Demolition of stone slab or tiles of any description or thickness in floors or aprons etc(laid bedded and pointed in any mortar) complete all as specified and as directed.(upto 12 storey High of building) |
| 57 | M & L Marble green work 18 to 20mm thick (table rubbed and polished) insteps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shadecomplete all as specified and directed.(upto 12 storey High of building) |
| 58 | Demolition of cement concrete (unreinforced) ofany descriptions, below or above Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete allas specified and as directed. |
| 59 | Material and Labour for PCC (1:4:8) type D-2(using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed. |
| 60 | Material and Labour for pre-polished cement concrete designed coloured pavement tiles glossy finish of size not exec 0.16 Sqm of each tile of thickness20mm thick or equivalent size as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 61 | Material and Labour for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and pigment complete all as specified and directed.NOTE:Works against all items contained in the BOQ have to be carried out upto and including 12th floor of the Bldgs and quoted rates shall be deemed to be included to this factor |