| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | a) All kinds of soil. |
| 3 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 4 | a) All kinds of soil. |
| 5 | i) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 6 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 7 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 9 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | 1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 12 | a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 13 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 14 | a) 20 mm dia (heavy type) |
| 15 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 16 | 100x63x3.2 mm |
| 17 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 18 | 300x16 mm |
| 19 | 250x16 mm |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 21 | a) 300x10 mm |
| 22 | b) 150x10 mm |
| 23 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 24 | 125 mm |
| 25 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 26 | Twin rubber stopper |
| 27 | 12 mm cement plaster of mix : |
| 28 | 1:6 (1 cement: 6 fine sand) |
| 29 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 30 | 1:6 (1 cement: 6 fine sand) |
| 31 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 32 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 33 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 34 | One coat. |
| 35 | Two coats. |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 37 | a) One or more coats on old work. |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 39 | a) Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 40 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 41 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 42 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 43 | Orissa pattern W.C. pan of size 580x440 mm |
| 44 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 45 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 46 | 10 litre capacity - White |
| 47 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 48 | White solid plastic seat with lid |
| 49 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 50 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 51 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 52 | Rectangular shape 453x357 mm |
| 53 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 54 | Flat back wash basin of size 550x400 mm. |
| 55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 56 | Flexible pipe |
| 57 | 32 mm dia |
| 58 | 40 mm dia |
| 59 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 60 | Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 62 | a) 20 mm nominal outer dia. Pipes. |
| 63 | b) 25 mm nominal outer dia .Pipes. |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 65 | a) 25 mm nominal outer dia. Pipes. |
| 66 | b) 40 mm nominal outer dia. Pipes. |
| 67 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 68 | 45 cm length |
| 69 | 15 mm nominal bore |
| 70 | Providing and fixing cPVC Union/cPVC nipple in G.I/cPVC pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 71 | a) 20 mm nominal bore |
| 72 | b) 25 mm nominal bore |
| 73 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 74 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 75 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 76 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 77 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 78 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 79 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 80 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 81 | a) 25mm nominal bore. Weighing not less than 62 gms. |
| 82 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 83 | a) 100 mm diameter |
| 84 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: |
| 85 | a) 100 mm diameter S.W. pipe |
| 86 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 87 | 30 mm thick |
| 88 | Providing & fixing fly proof wire gauze mesh to windows, clerestory windows & doorsandto balcony grills with T.W. beading 15x1mm, nails & screws or with binding with GI wires as per site requirement and as directed by E-I-C etc. complete. |
| 89 | Stainless steel (grade 304) wire gauze of 0.3 mm dia wire and 1.8mm aperture on both sides. |
| 90 | Providing and fixing CPVC ball valve ( half turn )in CPVC pipe line including cutting and jointing with CPVC solvent cement etc. complete. |
| 91 | 25mm nominal bore |
| 92 | 40mm nominal bore |
| 93 | Repairs to the existing Aluminium/PVC/Wooden doors/windows by removing and refixing the same after attending necessary repairs etc. with necessary screws, nails ,hinges etc. including welding etc. wherever required complete to make it working condition (Each door/window irrespective of size will be measured for payment. cost of Hinges, handles and other accessories if any will be paid separately). |
| 94 | Removing glass panes from windows and replacing them with new glass panes with putty and nails wherever necessary : float glass panes of thickness 4mm |
| 95 | a) for windows in ground floor and /or for windows which can be accessed from inside of the room / balcony with ladder arrangement wherever necessary. |
| 96 | b) for windows in upper floors ( other than ground floor ) up to 8 floors with necessary Jhoola arrangement |
| 97 | Removal of vegetation at walls/roofs and floors/drainage systems/water supplying stream of the building/over head tanks or at any location and applying any special chemical to defective area to prevent vegetation growth and finishing the same with cement concrete/mortar to match the surface of walls/floors/roofs., etc. complete as per the directions of engineer-in-charge(cement concrete/mortar to be paid in separate item.)(Uprooting of vegetation in each location will be measured as one job) |
| 98 | Cutting /Pruning branches of trees for avoiding entering houses and obstructing colony lighting and electrical wire free passing and disposing the cutting pieces away from the compound to the dumping ground as directed by the engineer-in charge. (Pruning/cutting of each branches for each tree will be measured as one job) |
| 99 | Repairs to the existing Aluminium/PVC/Wooden doors/windows by removing and refixing the same after attending necessary repairs etc. with necessary screws, nails ,hinges etc. including welding etc. wherever required complete to make it working condition (Each door/window irrespective of size will be measured for payment. cost of Hinges, handles and other accessories if any will be paid separately). |
| 100 | Rebate for taking away unserviceable material after fixing new material etc., complete a) 15 mm brass bibcock / stop cock/pillar cocks |
| 101 | Cleaning of terrace / canopy/ chajjas by removing leaves grass dust, rubbish and other deposited / accumulated materials etc. including removal of blockages/chockages of khurras/spouts of terrace/chajjas etc. and disposal of rubbish to the dumping ground out side periphery of the building. (plan area of the terrace/chajja/canopy will be measured for payment) |
| 102 | Terrace area connected to blocked khurras and spouts & like. |
| 103 | Chajjas area connected to blocked spouts & like |
| 104 | Cleaning of Under ground water storage tank or sump or over head tank of any capacity by following method: (1) Empty the tank/sump and make it to near dry, (2) Apply bleaching powder uniformly ( tank capacity @ 0.50gms/litre) surface of inside the tank/sump perfectly by removing scales on walls and wait for one hour (3) after one hour clean/rinse at the tank/sump with fresh water ,repeat the above process , (2) and (3) for two to three times , (4) remove the mud/silt/sludge and garbage from the tank with specified sludge pump, (5) spraying anti bacteria agents on walls to kill harmful bacteria. Rate includes for all above operations including the equipment and material required for cleaning all complete as directed by the Engineer-in-charge. |
| 105 | a)Liquid capacity of water tanks of any capacityin litres is measured for payment |
| 106 | Cleaning of existing sewer lines, manholes etc. Cost includes all labour for removing the silt, slush, waste etc. and rodding the sewer lines and manholes by mobile sewer rodding equipment/manually from manhole to manhole to clear the blockage, chokages etc. for proper functioning of sewer lines( The payment shall be made for removal of blockages in between manhole to manhole as one job with all above operations.) |
| 107 | Providing and fixing M.S Brackets for wash basin/Sink or required size embedded in cement concrete including cutting and making good walls etc., all complete as per the directions of Engineer-in-Charge. Pair of brackets is measured for payment. |
| 108 | Repairs to pvc flush tank with replacing the lever or handle wherever required including changing the syphon set including cleaning the dirt, scales, adjustment in the flush mechanism etc., complete. Repairing as above for each tank is measured for payment. |
| 109 | Repairs to pvc flush tank with replacing the lever or handle wherever required but without changing the syphon set including cleaning the dirt, scales, adjustment in the flush mechanism etc., complete. Repairing as above for each tank is measured for payment. |
| 110 | Cleaning of existing Gully chamber for removal of blockages including removing the silt , slush,, waste etc.and rodding the sewer lines and nearest manholes by manuallyto clear the blockage, chokages etc. for proper functioning of sewer line ensuring smooth flow etc. (Cleaning as above for each gully trap chamber is measured as one job) |
| 111 | Replacingexisting damaged sanitary pipes by providing UPVC SWR soil waste and vent pipes by cutting, removing, replacingwith working pressure 4kgf/sq.cm conforming to IS : 13592 Type B of Ultra fit/Self fit including jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 and with solvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant. (i)Single socketed pipe(couplings, other accessories will be paid separately) |
| 112 | 110mm diameter |
| 113 | 90mm diameter |
| 114 | 75mm diameter |
| 115 | Replacing existing on wall face damaged unplasticised - PVC moulded fittings/ accessories with new fittings/accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A including cutting, replacing, jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 116 | Tee with door |
| 117 | 110X110X110 |
| 118 | 90X90X90 |
| 119 | 75X75X75 |
| 120 | Plain bend of required degree |
| 121 | 110mm bend |
| 122 | 90mm bend |
| 123 | 75mm bend |
| 124 | Door bend |
| 125 | 110mm |
| 126 | 90mm |
| 127 | 75mm |
| 128 | Y-Junction with door |
| 129 | 110mm |
| 130 | 90mm |
| 131 | 75mm |
| 132 | Rebate for taking away ofscrap of dismantled SC.I pipes with fittings etc. complete |
| 133 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of PVC plugs, screwed with M.S. screws of required length including cutting brick work and fixingand making good the wall etc. complete. |
| 134 | 90 mm |
| 135 | 110 mm |
| 136 | Pointing of tile joints with poly sulphide/white cement up to 2mm depth by removing existing damaged/loosened white cement from joints to arrest leakage as directed by engineer in charge(Area of tiled flooring/ dadoo where above operations are made is measured for payment) |
| 137 | Carting out of building rubbish / malba / similar unserviceable, dismantled, excavated or waste materials by mechanical means, through private carrier including lifting, loading, transporting, unloading to municipal dumping ground beyond 50 m initial lead,or in any other compound as decided by the Engineer-in-charge, for all leads including all lifts involved. |
| 138 | Providing and fixing PTMTHealth faucet with wall support lever of 15mm nominal bore withnozzle jet and handle of approved quality of approved quality and colour etc. all complete. a)15 mm nominal bore |
| 139 | Cleaning of existing staff quarter at all heights by removal of cob web, pigeon droppings, debris, unwanted, un serviceable abandoned material etc. from all the rooms, dusting of walls, windows, doors, cupboards etc., washing the flooring of all rooms with detergent, washing the flooring and dado of toilets and bath room with the acid etc., making them into useable/liveable conditions complete etc. for immediate occupation of quarter as directed by Engineer-in-charge. Each quarter cleaning is measured as one job. |
| 140 | Type-II/III Qtr. |
| 141 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. . |
| 142 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. . |
| 143 | Hot finished welded type tubes. |
| 144 | Extra for galvanising (of thickness not less than 120 microns) on M.S angles, flats, gussets plates, bolts, nuts and other fasteners. |
| 145 | Providing and fixing PTMT Two way bib cock or stop cock of approved make, quality and colour . a)15 mm nominal bore |