| 1 | SH-IA : Supply of GLF system & associated electrical worksSupply of FAA/ICAO/DGCA-CAR Compliant Inset type LED Uni directional Stop Bar (RED) light fitting suitable for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with LED lamp with integral driver and electronics suitable for 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, \"O\" ring seal, pressure relief test plug, hardware, red prism / lenses and all standard accessories and ready for site installationcomplete as required as per sepcifications. |
| 2 | Supply of FAA/ICAO/DGCA-CAR Compliant high intensity Elevated LED Runway guard light (yellow) with two flashing light fixtures with black independent visors, 6.6A Current driven input power supply, LED lamps/module, flashing rates 45-50 Per Minute, frangible support, high strength base plate for runway guard light to resist wind speed (300 mph), gaskets etc complete as required as per specifications. |
| 3 | Supply of FAA/ICAO/DGCA-CAR Compliant elevated type omni-directional (Blue), medium intensity LED type Taxiway Edge Light fitting for aviation visual aid complete with LED suitable for operation at 6.6 Amps, Lens clamping mechanism, breakable coupling, gasket, two pin secondary leads, base plate and other accessories including integrated encapsulated electronic module complete as required as per sepcifications. |
| 4 | Supply ofFAA/ICAO/DGCA-CAR Compliant inset type omni-directional (Blue), medium intensity LED type taxiway Edge Light fitting for aviation visual aid complete with LED and integral driver and electronics suitable for 6.6 Amps and provided with lenses / prism, filters, lens protection ring, shallow base,matching body, single plug, inner & outer cover, two pin secondary leadscomplete with other accessories as required as per specifications. |
| 5 | Supply of 2C x 2.5 sqmm 600 V grade, copper conductor, EPR insulated, PCP/CPE/TCP sheathed, unscreened, non-shielded, unarmoured anti-termite and anti-rodent treated underground secondary cableconforming to IS:9968-1 as amended up to date and as per technical specifications etc. complete as required. |
| 6 | Supply of1 X 6 sqmm, 5 KV grade copper conductor, XLPEinsulated, PVC sheathed, single core, unscreened, non-shielded, unarmoured anti-termite and anti-rodent treated underground Airfield Lighting cable conforming to IS:7098 part-II as amended up to date and as per technical specifications etc. complete as required. |
| 7 | Supply of 6 sqmm, 5 kV grade Plug and Receptacle,Type-I, Class \"B\" connector kit suitable for field attachment with 5 kV grade 1 x 6 sqmm primary cableas per FAA/ICAO/DGCA CARand conforming to technical specifications etc. complete as required. |
| 8 | Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for remote as well as local control operationson input voltage 230/415 volts, 50Hz AC supply with 6.6A output having 5 stepsbrightnesscontrol with variation of current output and able to communicate with PC or PLC controlled system, with suitable ratingMicroprocessor based release (Ics = Icu = 25kA) incomer 3 Pole 63 Amp. MCCB, digital output ammeter (0-10A), overcurrent, overvoltage, open circuit and earth fault protection and digital earth leakage meter, two stage earth leakage detector, positive back indication equipments, LED/LCD display, suitable for connection and communicationwith ALCMSfor operation of LED type AGL Circuits etc complete as required confirmingto technicalspecifications for the following rating.a) 2.5 Kw |
| 9 | Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for remote as well as local control operationson input voltage 230/415 volts, 50Hz AC supply with 6.6A output having 5 stepsbrightnesscontrol with variation of current output and able to communicate with PC or PLC controlled system, with suitable ratingMicroprocessor based release (Ics = Icu = 25kA) incomer 3 Pole 63 Amp. MCCB, digital output ammeter (0-10A), overcurrent, overvoltage, open circuit and earth fault protection and digital earth leakage meter, two stage earth leakage detector, positive back indication equipments, LED/LCD display, suitable for connection and communicationwith ALCMSfor operation of LED type AGL Circuits etc complete as required confirmingto technicalspecifications for the following rating.a) 7.5 Kw |
| 10 | Supply of 15 Watt, 6.6/6.6 Amp rating completely enclosed rubber covered isolating transformer for use of 6.6 amps series airport lighting circuits having nominal voltage rating of 5KV rated for operation on 50 Hz. The transformer shall be water tight and shall be designed for direct burial in the earth or installation in a Housing Boxin conformity with ICAO/DGCA-CAR, complete as required as per specifications. |
| 11 | Supply of 45 Watt, 6.6/6.6 Amp rating completely enclosed rubber covered isolating transformer for use of 6.6 amps series airport lighting circuits having nominal voltage rating of 5KV rated for operation on 50 Hz. The transformer shall be water tight and shall be designed for direct burial in the earth or installation in a Housing Boxin conformity with ICAO/DGCA-CAR, complete as required as per specifications. |
| 12 | Supply of 1 x 16 Sq.mmPVC insulated copper conductor single core un-armoured flexible cable of 1.1 KV grade confirming to IS 694 for earth connection etc complete as required. |
| 13 | Supply of LED Guidance signage board of various sizes made out of 2 mm thick anodized aluminium frame with suitable angle support, 1.5 mm thick aluminium back symbols of sign should be screen printed on inside of sign face made of self-adhesive 3M film applied on the inside face with required coloring as approved by E-I-C. Sign board shall be uniformly internally illuminated with required LED\"s i/c all other accessories to achieve uniform illumination level and with suitable driver and electronics to operate on 2.8 Amp to 6.6 Amp AC, made for water tightness and locking arrangements, mounting legs with frangible coupling & base frame etc. meeting the latest ICAO/DGCA-CAR standards complete as per specifications etc. as required. The LED signage board shall be provided with an electronic LED driver having dual input capability and capable of operating from two independent isolating transformers, connected to separate series circuits.Note- The rate shall be quoted considering Wastages. |
| 14 | Supply of 3C x 16 Sq. mm.size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor power cable conforming to IS 7098 (Part-I) as amended upto date. |
| 15 | Supply of 4C x 16 Sq. mm.size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor power cable conforming to IS 7098 (Part-I) as amended upto date. |
| 16 | Supply of 1 X 2.5 sq.mm FRLSH PVC insulated copper conductor single core wire for end to end termination for earthing, preferably green colour conforming to conforming to IS:694 as amended up to date and technical specifications etc. complete as required. |
| 17 | Supply of 1.1 KV grade, Aluminium Conductor, XLPE insulated, galvanised steel strip armoured & overall PVC sheathed armoured power cable as per IS: 7098 (Part-I) upto latest amendments complete as required.a) 3.5CX120 Sq.mm |
| 18 | Supply of 50 mm outer dia. lSI marked HDPE pipe as per 1S:4984:2016, of rating PE 80, PN 10 with 4 mm nylon rope etc. complete as required. |
| 19 | SH-IB:Installation, Testing & Commissioning of GLF system & associated electrical worksInstallation, testing and Commissioning of inset type fitting with deep core cutting for fixing shallow base, aligning and setting i/c providing sealing material and installation of Isolating Transformer, Crimping / Jointing of secondary lead connectors & other accessories required for commissioning i/c supply of all materials except isolating transformer etc. as per specification complete as required. a) Fitting size up to 8 \" / 12 \" |
| 20 | Installation, testing & commissioning of Elevated type taxiway light fixtures/ Runway Guard light on existing transformer housing boxes and Crimping / Jointing of secondary lead connectors, installation of isolating transformers, i/c supply of all materials except isolating transformer etc.as per specificaiton complete as required. |
| 21 | Installation, Testing, Commissioning of CCR including termination of incoming and outgoing power and control cables, inter connection, making foundation/ suitable size of MS channel for fixing of CCR base, earthing connection etc. complete as required |
| 22 | Installation, Testing and Commissioning of guidance signboards of various sizes (upto 2 m length) i/c installation of isolating transformer of suitable ratingand providing secondary leads etc.i/c pedestal of 1m all around the signage board with 1:2:4 (cement, concrete, coarse) of thickness 100mm with neat cement finish plaster, testing and commissioning etc. as required as per specification. |
| 23 | Laying of50 mm dia size HDPE pipewith accessories like couplers, bends, tee etc including excavation of the soil upto a depth of approx. 750 mm, back filling & making good the same as per site requirement as per the direction of engineer in charge. |
| 24 | Laying of 50mm outer dia. HDPE pipe with accessories like socket, couplers, bends etc. complete with fitting, cuttings, jointing wherever applicable to connect the consecutive transformer housing boxesandtransformer housing box to other fitting / location. The laying shall be in Apron/Taxiway shoulder at suitable depth along the civil construction works etc complete as required as directed by EIC. |
| 25 | Laying of one number PVC / XLPE / AFL/ EPR insulated & PVC / PE / PCP sheathed copper conductor power cable of grade exceeding 0.4 KV but not exceeding 11 KV of size not exceeding 25 sq. mm. in the existing cable duct / RCC/HUME/METAL/HDPE/DWC pipes etc. as required. |
| 26 | Laying of one number PVC / XLPE / AFL/ EPR insulated & PVC / PE / PCP sheathed copper conductor power cable of grade exceeding 0.4 KV but not exceeding 11 KV of size not exceeding 25 sq. mm in the existing masonary open duct/trench/open surface asrequired. |
| 27 | Laying of 1 x 2.5 Sq.mm PVC insulated FRLSH copper conductor single core flexible cable of 1.1 KV grade in duct / masonary trench / RCC / HUME / METAL / GI / HDPE / DWC pipe etc. as required. |
| 28 | Earthing with \"B\" class G. I. earth pipe 4.5 mtrs. long x 40 mm dia i/c accessories and providing masonry enclosures with cover plate having locking arrangement & watering pipe etc. i/c charcoal/ coke and salt complete as required as per specification. |
| 29 | Earthing with copper earth plate 600mm x 600mm x 3.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. Including charcoal and salt complete as required. |
| 30 | Earthing with GI earth plate 600mm x 600mm x 6.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. Including charcoal and salt complete as required. |
| 31 | Cutting kerf of suitable size in taxiway/runway/apron of PQC/bituminous surface i/c chipping, hammering, cleaning & drying etc. & refilling the kerf with sealant material including primer etc. as reqd. in bitumin/PQC area & laying following numbers of secondary leads:-a) 01 No. Secondary lead of size 2C x 2.5 sq.mm. |
| 32 | Cutting kerf of suitable size in taxiway/runway/apron of PQC/bituminous surface i/c chipping, hammering, cleaning & drying etc. & refilling the kerf with sealant material including primer etc. as reqd. in bitumin/PQC area & laying following numbers of secondary leads:-a) 2 No. Secondary lead of size 2C x 2.5 sq.mm. |
| 33 | Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 34 | Providing and fixing 25mm x 5 mm G.I. strip in 40mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 35 | Providing and fixing 25mm x 5mm copper strip on surface/in recess/existing pipe for connections etc. as required. |
| 36 | Providing and fixing 25mm x 5mm G.I. strip on surface/in recess/existing pipes etc.for connections etc. as required. |
| 37 | Providing and fixing 6 SWG G. I. wire on surface or in recess or with HDPE pipe for loop earthing as required. |
| 38 | Making connection of 5 KV grade, 1 x 6 Sq.mm Copper conductor primary cable with plug & receptacle (but excluding cost of plug & receptacles) including filling the gap with water sealed material applying HT tape of reputed make etc. complete as required at site. |
| 39 | Supply and Fixing of 600 V grade Plug & Receptacle, Type-II, Class \"B\" connector kit for field attachment with 2C x 2.5 Sq.mm secondary lead cable. |
| 40 | LT Panel (GLF PANEL)Supply, Installation, Testing and Commissioning ofindoor cubicle LT panel as per IEC 61439, IP42, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars with 100% size neutral bus as that of phase bus, supported with SMC bus bar supports, with short circuit withstand capacity as per design subject to minimum 25 kA for 1 sec, bottom base channel of MS section not less than 75 mm x 40 mm, fabrication shall be done in transportable sections, entire panel shall have a common Copper earth bus bar of size as perIS 3043 subject to minimum 32 mm x 5 mm at the rear with 2 Nos. earth stud, solid/ flexible copper connections from main earth bus bar to switchgears with required size of Cooper conductors/ bus bars and control wiring with 2.5 sqmm FRLSH PVC insulated copper conductor cable, cable alleys, cable gland plates in two halves, includingcontrol and interlocking of incomers, bus coupler and providing following switchgears/ accessories as per specifications. Incomer 2 Nos. 100A, 4P MCCB,Microprocessor based release (Ics = Icu = 25kA) with inbuilt O/L , S/C & E/F protection as per specification and each incommer shall be provided with following accessories.1 Set of phase indicating LED lamps with 2 amp back up MCB.1 No. 96 x 96 sqmm Digital MFM meter and 3 nos. Cast resin CTs of ratio 100/5A , Class 0.5 accuracy and 10 VA burden, suitable to measure voltage, Ampere, Frequency, Power Factor, KVA, KW, KVAH, KWH, MDI with RS-485 port.1 Set of ON/ OFF/TRIP Indicating LED Lamps With 2 Amp MCB.Buscoupler 4P aluminiumbus bars of 100A capacity with heat shrinkable coloured sleeves including SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25 KA for 1 sec. Outgoings.6 Nos.63A 4P MCCB with built in thermal magnetic release with adjustable setting (Ics= Icu = minimum 25 KA)For each busbar section-1 Set Surge protection device Type 2 ( Class C), 4 Module, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up < 1.5kV.SPD shall be with built in fuse and plugable type. For connecting SPD minimum 10sqmm copper wire must be used. The SPD shall becomplientand tested from KEMA KEUR / VDE / NABL tested as per relevant IEC. |
| 41 | Supply Installation ,Testing and Commissioning of IGBT, Three level PWMDesign based, modular type, true online double conversion type 2 X 20 KVA UPS System in parallel configuration withharmonic filter suitable to drive constant current regulators(CCR) with 100% unbalanced load at output at full load condition,working on 3 phase, 4 Wire, 415 Volt, 50 Hz and delivering output 3 phase, 4 Wire, 415 Volt, 50 Hz , High Efficiency , havingSMF Barreriesto support minimum 30 minutes back up with each UPS, THD less than 3% , Power Factor not less than 0.90, having transfer time of 0 m sec, up along with all accessories i.e.breakers,DC cables, cabinets,battery racks, interconnecting links and related items etc as per site requirement for making the UPS Operational and meeting the standard of IEC and as per specification complete as required. |
| 42 | Laying of one number PVC insulated & PVC sheathed XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct/surface/pipe/raceway as per specification asrequireda) Above 95 sqmm and upto 185 sqmm |
| 43 | Supplying and making end termination with brass compression gland and Aluminimum lugs for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required.a) 3.5X 120 Sq.mm |
| 44 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.a) 3C x 16 Sq. mm. |
| 45 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.a) 4C x 16 Sq. mm. |
| 46 | Supply and fixing of fire retardant electrically insulated synthetic mat of class A, 2.5 mm thick suitable for all voltages not exceeding 11 KV AC and 240V DC system meeting requirements of IS 15652:2006 tested for breakdown strength, tensile/elongation, aging properties, insulation resistance, effect to acid, alkaline, diesel, transformer oil & leakage current test, fire test etc. having minimum width of 1000 mm ±20 mm along with all allied materials such as Pu-resin, Chemi bound, special PVC adhesive, liquid primer etc. in what so ever quantity required to complete the job as per site conditions and as per instructions from Engineer-in-Charge. |
| 47 | Constructing 23cm thick brick wall masonry chamber in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C top slab 10 mm thick with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement complete as per standard design: Inside size 1000 mm X 1000 mm x 1200 mm (LXWXD) including RCC Cover is to be provided along with hook for lifting purpose etc complete as required as per the direction of Engineer-In-Charge. |