Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-01-2026 | BOQ CORRIGENDUM | BOQ | 22-01-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings, complete all as specified and as directed. |
| 2 | Supply & Installation Pre-painted,High Tensile 550 Mpa yield strength, Bare Galvalume Steel Sheet having maximum pitch of 250mm c/c & minimum 30mm crest depth in length as per site requirement.The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150.The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap.The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal, complete all as specified and as directed. |
| 3 | Supply & Installation Pre-painted,High Tensile 550 Mpa yield strength, Bare Galvalume plain Steel Sheet.The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150.The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap.The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description, complete all as specified and as directed. |
| 5 | S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 6 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 7 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet, complete all as specified and as directed. |
| 8 | S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensorsystem (Grid) madeout of GI sheet main Tee of size 23.5mmx 38.50mmX 0.36mm and cross Tee of size 23.5mmX 23.5mmX 0.36mm and angle size 19mmx 19mmX 0.36 mm. Grid of modular size 600mmX 600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer\"s instruction, complete all as specified and as directed.(Make : Everest or equvalent as approved by GE) |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the, complete all as specified and as directed. |
| 10 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6), complete all as specified and as directed. |
| 11 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and as directed. |
| 12 | M&L for coloured & polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry as in floors includig 20mm thick screed bedCM (1:6), complete all as specified and as directed. |
| 13 | M&L 350x 250x 7 mm or450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM (1:4) finished even and rough, complete all as specified and as directed. |
| 14 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness(below or above ground level), complete all as specified and as directed. |
| 15 | M&L for 50 mm thick cementconcrete (1:3:6) type C-2 (using40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishingcement concrete surface even and smooth without using extra cement with and including all necessaryform work to divide the area in panels, finishingexposededges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. |
| 16 | Taking down cementplaster on brickor stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with water etc, complete all as specified and as directed. |
| 17 | M&L 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 18 | Supplyonly integral water proofing compond, complete all as specified and as directed. |
| 19 | M&L for 10 mm thick rendering in cement mortar (1:6) on Brick/stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and fair (without using extra cement), complete all as specified and as directed. |
| 20 | M&L for preparation of newly plastered surfaces and applying three coat of cement base paint, complete all as specified and as directed. |
| 21 | M&L preparation existing treatment on walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 22 | M&L for preparation on old plastered of wall and applying one coats of cement base paint, complete all as specified and as directed. |
| 23 | M&Lpreparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent), complete all as specified and as directed. |
| 24 | M&L for three coats of white wash on new plastered surface including prepration of wall surface, complete all as specified and as directed. |
| 25 | M&L for applying two coat of white wash on old plastered surface including preparation of wall surface, complete all as specified and as directed. |
| 26 | M&L complete removal of existing treatment and applying two coats of oil bound distemper using mechnical spray gun/hand rollars over acoat of interior wall primer with and including 2mm thick wall care putty in two coats (Birla white or equivalent), complete all as specified and as directed. |
| 27 | Taking down chowkhatsor frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 28 | Taking down chowkhatsor frame exc 1.50 andnot exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 29 | S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 30 | S&F steel window or ventilator fixed type with glazing bar, complete all as specified and as directed. |
| 31 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edgesbeading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 32 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed. |
| 33 | S&F 100 mm sizebutt hinges, medium weight , coldrolled, mild steel, complete all as specified and as directed. |
| 34 | S&F of 100 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 35 | S&F 125 mm size Aluminium handles, cast type, anodisedand fixed, complete all as specified and as directed. |
| 36 | S&F of 300 mm long aluminium alloy, anodised slidingdoor bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and as directed. |
| 37 | M&L for second class hardwood of 25mm thickness boarding in floor and skirting of planed one side, with butt joints and fixed with nails supplied and fixed, complete all as specified and as directed. |
| 38 | S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed. |
| 39 | M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed. |
| 40 | M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 41 | M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 42 | S&F in repairs PVClow level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and as directed. |
| 43 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \"ORRISA\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete, complete all as specified and as directed. |
| 44 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge, complete all as specified and as directed. |
| 45 | S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 46 | S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 47 | S&F of 110 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 48 | S&F of 75 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 49 | S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 50 | S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 51 | S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and as directed. |
| 52 | S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union, complete all as specified and as directed. |
| 53 | S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and as directed. |
| 54 | S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 55 | S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 56 | S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 57 | S&F Vitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets, complete all as specified and as directed. |
| 58 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 59 | S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor, complete all as specified and as directed. |
| 60 | M&L for suface excavation n exc 30cm depth and averaging 15cm deep and getting out in soft soil, complete all as specified and as directed. |
| 61 | Excavating in trenches n exc 1.5m wide and nexc 1.5m depthfor foundation tec n exc 10 sqm on plan and getting out in soft/loose soil, complete all as specified and as directed. |
| 62 | Excavting in trenches, n exc 1.5m wide and exc 1.5m and exc 3.00 depth for foundation tec or for shafts wells cesspits , manholes, pier holes etc n exc 10 sqm on plan and n exc 1`.5m depth and getting out in hard or dense soil, complete all as specified and as directed. |
| 63 | M&L for loose filing with broken brick aggregatge of gauge 80 to 150mm in soakage pits, soakage well etc, complete all as specified and as directed. |
| 64 | M&L for sand filling unde floor or in foundation including watering and consolidation, complete all as specified and as directed. |
| 65 | Excavating over areas, nexc 1.5mtr in depth, for foundation etc and getting out in soft/loose soil, complete all as specified and as directed. |
| 66 | Excavating over areas, exc 1.5mtr but not exc 3.0 mtr in depth, for foundation etc and getting out, complete all as specified and as directed. |
| 67 | M&L for PCC (1:3:6) type C2 (using 40mm graded aggregates) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 68 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radiius built in CM (1:4), complete all as specified and as directed. |
| 69 | M&L for bricks work with best quality locally available first class bricks conforming to sub-class B bricks in one and half bricks thick honey comb walling built in CM (1:3), complete all as specified and as directed. |
| 70 | M&L for rendiring 10mm thick on fair face of brick or concrete surface in cmement mortar (1:4), complete all as specified and as directed. |
| 71 | Cutting chases, pinning in brick/pcc block wall and making good where required and poniting in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, lintel etc: and cutting chase for concealed water tubing or concealed conduit wiring,etc. and make good, cuttinng not exc 10cm girth, complete all as specified and as directed. |
| 72 | M&L for RCC M-25 (20mm graded aggregates) design mix as in cover slab cast in situ supported on walls etc, complete all as specified and as directed. |
| 73 | S&F of TMTbars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 74 | M&L for TMT 6 to 8mm cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with including mild steel (anealed) not less than 0.9mm dia or securing with clips for columns hooking ends and binding with incl mild stee wire (anealed) not less than 0.9mm dia or securing wiht clips, complete all as specified and as directed. |
| 75 | M&L for fromwork to edges of concrete flats, threads, breaks in floors window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizon tal or slopong and similar work exc 10cm but n exc 20cm wide, complete all as specified and as directed. |
| 76 | M&L fromwork to suspended slabs such as roof slabs, floor slab, landings and smilar work, not exc 200mm thick (horizontal or sloping) rough finished surface flat, complete all as specified and as directed. |
| 77 | M&L for plain cement concrete bed (1:3:6) type C2 (using 40mm graded aggregates) to drain pipe 100/110mm bore including packing under and hunching agaist the sides of pipes after they laid and tested, complete all as specified and as directed. |
| 78 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point in soils, complete all as specified and as directed. |
| 79 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, complete all as specified and as directed. |
| 80 | Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete, complete all as specified and as directed. |
| 81 | Demolition of brick work/stone masonry, built in cement mortar including all quoins, arches, pillars etc butincluding ashlars facings, dressed stone work and pre-cast concrete articles, complete all as specified and as directed. |
| 82 | M&L for reinforced cement concrete type B1 (1:2:4) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 83 | Use & Waste of formworkto sides and soffits of shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed. |
| 84 | S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorattive knobs etc, complete all as specified and as directed. |
| 85 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 86 | M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 87 | Material and labour for old size sub Class B bricks bricks, straight or curved on plan to any radius in halfbrick thick wall built in cement mortar (1:4) having compressive strenght notless than 75 kg/Sq cm, complete all as specified and as directed. |
| 88 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed. |
| 89 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc, complete all as specified and as directed. |
| 90 | S&F Anodised aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified and as directed. |
| 91 | Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed. |
| 92 | Dismantling and taking down unserviceable main switches, DBsany type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed. |
| 93 | Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and includingPVC casing and capping not less than 20mm size, medium grade with all necessary fittings, surface wiring , for light /Fan point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated steel terminal boxes/ on PVC rectangular box suitable size (concealed type in permanent bldg and surface in temporary bldg or as directed )for mounting fittings like switch, socket, fan regulator etc. laminatedbakelite sheet cover ,for housing switches, socket outlet, regulator etc, complete all as specified and as directed including testing on completion. |
| 94 | Description all as per item No 93.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board, complete all as specified and as directed. |
| 95 | Description all as per item No 93.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board, complete all as specified and as directed. |
| 96 | Description all as per item No 93.00 here in before but for one 3 pin 15/16 Amps switch socket outlet point controlled by one switch on independent board, complete all as specified and as directed. |
| 97 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 98 | Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 99 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 100 | Supply and fix Socket,16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 101 | Supply and fix switch piano flush button, single pole, 5/6amps, one way, complete all as specified and as directed. |
| 102 | Supply and fixing lamp/angle holder insulated body with back plate for batten fitting, complete all as specified and as directed. |
| 103 | Supply and fixing LED retro fit lamp B-22holder base invertor light with poly carbonate body and aluminium heat sink of10W, complete all as specified and as directed.Make: Surya or equivalent of Havells/Crompton. completeall as specified and directed. |
| 104 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. |
| 105 | Supply and fixing LED batten surface / wall mountedwith specially designed comprises of extruded channel in thermally conductive material.High transulucent serrated milky white diffuser used to grt glare free and smooth light distribution. power consumption 20W, system efficiency of≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) asper IEC standard all as per specified and directed, complete all as specified and as directed. |
| 106 | Supply and fixing LED batten surface /Roof/ wall mountedpride plus inverter battenwith Lithium Ion battery, 3 step dimming, upto 10 Hrs battery backup, charging time- 8 to 10 Hrs, 20w, 6500K V1, complete all as specified and as directed.Make Havells cat part No: LHEXASP71W020or equivalent of philips or crompton |
| 107 | Supply and fixingwall mounting light fitting, brushed nickel finish fixture with acrylic diffuser including9W/10W LED lamp invertor light B22 base, complete all as specified and as directed.Make:Havells or equivalent model of Philips/Crompton. |
| 108 | Supply and fixing in repairs LED 2X2 PANEL 36 W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, complete all as specified and as directed.Make Havells or Equivalent of Crompton/Philips. |
| 109 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed. |
| 110 | S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizeincluding taking down old unserviceable fitting, complete all as specified and as directed. |
| 111 | S&F metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series, complete all as specified and as directed. |
| 112 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall, complete all as specified and as directed. |
| 113 | Supply and fixing in repairs 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN32 amps capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 114 | Supply and fixing in repairs 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 115 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 116 | M&Lfor sub main wiring along with earth wire of size two run of4 sq mm + one run of 4 Sq mm earth wire single core PVC insulatedcable with stranded copper conductor FRLS includingdrawinginto 25 mm PVC casing caping on surface of wall/roof including taking down of old servicible sub main wiring, complete all as specified and as directed.(Note : Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length). |
| 117 | Supply and fixing electric water heaterstorage type wall hanging mounting type with powder coated metallic body BEE 5 Star rated with diamond glass lined inner tank with maximum operating pressure of 8 bars incuding factory fitted thermostat maximum 75 Celsius with automaticthermal cutout and multifunctional saftey valve inculding suitable nuts & bolts for fixing arrangement operates on230V ,maximum power consumtion -2kW of capacity 25 Ltrs , withall accessories and connection pipe 15mm bore 2 Nosfor hot and cold water supply,geyser saftey cord with 16Amps ELCB completeincluding taking down old u/s Geaser & deposit to MES Store, complete all as specified and as directed.Havells Cat Part No : Monza Nu GHWAMUSWH025or equivalent Racold, Bajaj |
| 118 | M & L in repair earthing completewith galvanized steelearthplate electrode600 x 600 x 6 mmburieddirectlyinground (earthpitnotlessthan2.25 mdeepbellowgroundlevel)withtopedgeoftheplatenotlessthan1.5 m bellownormalgroundlevel, connectedtogalvanizedearth lead wire 4 mmdia.bymeansof galvanized iron or steel bolts, nuts, check nuts andwashers, and connected to equipmentsasdirected,includingfunnelwithGI med grade wateringpipe20 mmbore, wiremesh, charcoal orcokeandcommonsaltinalternatelayersof15 cmcompactedthicknessallaroundtheearthelectrode ,withconcretepitinPCC(1:3:6)type C-1 , 50 mmthickprecastRCC (1:2:4)typeB-1 coverslabreinforcedwith8 mmdiadeformedbar15 cm C/Candsuitablehandleof 10 mmdia roundbar,GI medium grade pipe for earth lead protectionincludingnecessaryexcavationearthworkinsoft/loosesoilanddisposalofspoiltoadistancen.exc.50 mandnecessarytestingcompleteallasshownonelectricalplateNo. 3ofMESSSRPart-I and, complete all as specified and as directed. |
| 119 | M&L for taking out old unserviceable UG cable of any size/ type from trenches/ wall/ roof etc. for necessary repair/ replacement/ re-laying works complete all as specified and directed by Engr-in-Charge. Note :- 1. Excavation and earth work should be measured and paid separately. |
| 120 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing, complete all as specified and as directed. |
| 121 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n\"exc. 1.50m deep for LT under ground cable/pole foundationand getting out including forming bottom surface to required level or slope, complete all as specified and as directed. |
| 122 | Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer, complete all as specified and as directed. |
| 123 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed. |
| 124 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed. |
| 125 | M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick, complete all as specified and as directed. |
| 126 | S & F Steel pipe glavanized lightgrade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. |
| 127 | Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail