| 1 | Providing and laying anti-skid vitrified floor tiles of size 600x600mm (thickness to be specified by the manufacturer) approved make in all colors, shades as approved by engineer- in-charge laid on 20mm thick bed of cement mortar 1:4 (1cement: 4 coarse sand) including pointing the joints with matching pigment or any other relevant pigment as directed including cost of spacers and grouting the same and cleaning the floor after finishing of work. Cost is inclusive of concreting in 1:2:4 mix for correction layer wherever required as per Eic directions. |
| 2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, including cost of spacers and grouting of joints . Size of tile 600x600 mm / 300x600mm as directed by EIC |
| 3 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, double moulding and polishing to edges to give high gloss finish etc. complete at all levels .Granite of any colour or shade as approved by EIC directions |
| 4 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to ceiling/walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions ofEngineer-in-charge With resin bonded fiber glass wool with density 24 kg/cum |
| 5 | METAL FALSE CEILING 600X600mmProviding and fixing suspended metal Grid false ceiling including GI perimeter & intermediate channels, ceiling angles, 600mmx600mm panels.* Panel Details : Panels shall be fabricated from 0.50 mm thick (TCT) Galvanised sheet and Powder Coated on external surface shall have flanges on all four side to rest on the exposed grid system to give 1200 x 300 mm centre to centre of \"\"T\"\". Panels should be 10 mm Tegular below. \"\" T \"\" to give visible groove look and Panel surface shall be 1175mm x 275mm for 24mm T.* Perforation Details: Tile shall have 3 mm dia holes at 7 mm centre to centre diagonally.* TEE details :Tee shall be hot dipped G.S. Tee section 3600mm long main Tee 24mm wide, Cross Tee 1200mm & Cross Tee 600 mm to form grid of 600mm x 600mm.* Installation Details: Main runners spaced at 1200mm centres to be securely fixed to the slab / Truss by means of Roll Plug and 4 mm dia GI rod at 1200 mm maximum centres and not more than 150 mm from spliced joints. The last hangers at the end of each main runner should not be greater than 600 mm from the adjacent wall.* 1200mm Cross Tee & 600mm Cross Tees to be interlocked between two main Tees to from grid of 600 x 600mm. Panels are then placed individually on the 600 x 600 mm exposed Grid framework created by Tees.GS Edge profile shall be fixed on the perimetry of walls and colums |
| 6 | GYPSUM FALSE CeilingProviding & fixing suspended false ceiling using 12.5mm thick Indian gypsum boards confirming to IS 2095-1982 and GI framework of Gyp steel or approved equivalent comprising of following. 1. GI perimeter channel of 0.55mm thick having one flange of 20mm, another of 30mm and web of 27mm fixed to brick wall partition along periphery of ceiling with the help of nylon sleeves and screws at 610mm c/c 2. GI intermediate channel ( size, 45mm web, two flanges each of 15mm & thickness 0.9mm ) suspended from the soffit / ceiling at 1200mm c/ c spacing. 3. GI ceiling sections of 0.55mm thick having knurled web of 51.5mm and two flanges each of 26mm with leaves of 10.5mm fixed to intermediate channel with the help of connecting clip at direction perpendicular to the intermediate channel at spacing of 600 mm c/c,. to Be finished with Jointing tape and Jointing compound including application of One coat primer as Per Gypsum board Manufactuerer specification. The rate quoted shall include making cut outs for fixing light fittings, grills, diffusers, speakers, smoke detectors, sprinklers etc. Cut outs have to be made with provision of the frame along perimeter of the cut outs/ opening with channels/ ply to support the ceiling adequately. No extra payment shall be made for making cut outs. |
| 7 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge 12mm thick ply (otherwise used for shuttering conforming to IS : 1328 BWP type |
| 8 | Providing and fixing machine molded ACP covering of approved pattern & design in panels and including grouting (groves) in required patter ,color nand design, made out of machine cut aluminum sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces /ceiling/walls floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia. and 75 mm long bolt including providing aluminum washers 2 mm thick & 15 mm dia. at a staggered pitch of 200mm Centre to Centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. Including frame work of rquired section complete as per direction of Engineer-in-charge.ACP 3.5mm thick of required color |
| 9 | Providing and fixing of M. S. Grill /Railing/Gate of angles / tees / flats / round and square bars/Hollow sections duly welded in frames of windows or with approved design, welded complete including applying a priming coat of red oxide complete |
| 10 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards |
| 11 | Earth work in excavation by manual/Mechanical means in foundation trenches or drains (not exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead as directed from edge of cutting .All kinds of soil |
| 12 | Supplying and laying of stone soling hand packed tightly including ramming, watering and carriages complete |
| 13 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering. All work up to all levels. 1:4:8 (1Cement: 4 fine sand: 8 graded stone aggregate 20mm nominal Size) Crushed |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to all levels.1:2:4 (1Cement: 2 coarse sand:4 graded stone aggregate 20mm nominal Size) Crushed |
| 15 | Form work. Centering and shuttering including strutting propping etc. removal of form work in Foundations: footings, bases of columns etc. for mass concrete. |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new steel work including sand papering and knotting complete Please Enable Macros to View BoQ information |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new steel work including sand papering and knotting complete Please Enable Macros to View BoQ information |